Requirements
configDB web service routines with no authentication required
def svc_get_version(configroot):
def svc_get_hutches(configroot):
def svc_get_device_configs(configroot):
def svc_get_aliases(configroot, hutch):
def svc_get_devices(configroot, hutch, alias):
def svc_get_configuration(configroot, hutch, alias, device):
def svc_print_device_configs(configroot, name):
def svc_print_configs(configroot, hutch):
def svc_get_history(configroot, hutch, alias, device):
configDB web service routines with authentication required
def svc_get_key(configroot, hutch):
def svc_add_alias(configroot, hutch, alias):
def svc_add_device_config(configroot, cfg):
def svc_modify_device(configroot, hutch, alias):
def svc_create_collections(configroot, hutch):
Three levels of authentication supported
URL Prefix | Authentication Level | Permissions | Notes |
---|---|---|---|
https://pswww.slac.stanford.edu/ws-kerb/devconfigdb/ws/ | Kerberos authentication | R/W | Kerberos ticket required |
https://pswww.slac.stanford.edu/ws-auth/devconfigdb/ws/ | Basic authentication | R/W | Hutch operator (xppopr etc.) |
https://pswww.slac.stanford.edu/ws/devconfigdb/ws/ | No authentication | Read |
Unit Tests
Kerberos Authentication
With and Without Kerberos Ticket
$ kdestroy -A $ klist klist: No credentials cache found (filename: /tmp/krb5cc_10218_avASDVDKU7) $ configdb --url https://pswww.slac.stanford.edu/ws-kerb/devconfigdb/ws/ cp SXR/BEAM/trigger_2 SXR/BEAM/trigger_6 ERROR:root:(('Unspecified GSS failure. Minor code may provide more information', 851968), ('No Kerberos credentials available (default cache: FILE:/tmp/krb5cc_10218_avASDVDKU7)', -1765328243)) failed to transfer configuration $ $ kinit Password for caf@SLAC.STANFORD.EDU: $ $ configdb --url https://pswww.slac.stanford.edu/ws-kerb/devconfigdb/ws/ cp SXR/BEAM/trigger_2 SXR/BEAM/trigger_6 $ $ configdb cat SXR/BEAM/trigger_6 > /tmp/trigger_6.txt $ configdb cat SXR/BEAM/trigger_2 > /tmp/trigger_2.txt $ $ diff -C 2 /tmp/trigger_2.txt /tmp/trigger_6.txt *** /tmp/trigger_2.txt 2020-04-16 17:57:29.218408467 -0700 --- /tmp/trigger_6.txt 2020-04-16 17:57:09.806479631 -0700 *************** *** 19,23 **** 'cam': 0, 'detId:RO': 'No serial number', ! 'detName:RO': 'trigger_2', 'detType:RO': 'trigger', 'doc:RO': 'No comment', --- 19,23 ---- 'cam': 0, 'detId:RO': 'No serial number', ! 'detName:RO': 'trigger_6', 'detType:RO': 'trigger', 'doc:RO': 'No comment', $
Basic Authentication
With and Without Valid User Name
$ python Python 3.7.7 (default, Mar 23 2020, 22:36:06) [GCC 7.3.0] :: Anaconda, Inc. on linux Type "help", "copyright", "credits" or "license" for more information. >>> import psalg.configdb.configdb as cdb >>> mycdb = cdb.configdb('https://pswww.slac.stanford.edu/ws-auth/devconfigdb/ws/', 'tst', root='configDB', user='xppopr') >>> mycdb.get_key() 126 >>> yourcdb = cdb.configdb('https://pswww.slac.stanford.edu/ws-auth/devconfigdb/ws/', 'tst', root='configDB', user='smoothopr') >>> yourcdb.get_key() ERROR:root:Web server error: 401 Client Error: Unauthorized for url: https://pswww.slac.stanford.edu/ws-auth/devconfigdb/ws/configDB/get_key/tst/ [] >>>
How To Bypass the HTTP Interface
mongoconfig.py Usage Example
>>> import psalg.configdb.mongoconfigdb as cdb >>> mikecdb = cdb.configdb("mcbrowne:psana@psdb-dev:9306", 'SXR', root='configDB') >>> mikecdb.get_aliases("tst") ['NOBEAM', 'BEAM'] >>>
Overview