Psana
- New Type: EvrData DataV4 - provides the convenience function present(evrcode) which returns 1 if an evr code is present. Users need not search through the FIFOEvents list. A 'present' table will be translated to hdf5 as well. Matlab Hdf5 users need to be careful about 1-up vs 0-up indexing and lookup evrcode+1 in the present table. EvrData DataV4 may replace DataV3 in new data as soon as Feb 25/2015.
- TimeTool: added options "beam_on_off_key" and "laser_on_off_key" to allow a Psana module to override TimeTool logic that categorizes events. See documentation at psana Module Catalog - TimeTool.Analyze. (PSAS-102)
- Translator:
- fastindex feature added to MPI Split-scan Translator for purposes of online analysis (PSAS-98)
- look for and translate data that user Psana Modules produce during BeginJob/BeginRun/BeginCalibCycle as well as EndJob/EndRun/EndCalibCycle. If found during the End* methods, create subgroup EndData to standard groups for this data. (PSAS-101)
- add "
split_cc_in_subdir" option to write cc files in a separate subdirectory.
(PSAS-104, PSWA-32) - Bump overall hdf5 schema version from 4 to 5.
- Previously, setting the option type_filter=exclude psana did not exclude epics. Now it will exclude epics.
- DDL: Rewrite DDL compiler wrappers to: (follow up to PSAS-103):
- exclude smalldata from Translator and hdf2psana backends
- optionally support DEVEL switch
- PSCalib:
- GeometryObject - add method get_geo_pars (PSAS-11).
- In GeometryAccess, GeometryObject, SegGeometryMatrixV1 - improve memory management (PSAS-34).
- In GeometryObject add parameter do_eval in get_pixel_coords(...) and evaluate_pixel_coords(...).
- CalibFileFinder.py - in method findCalibFileadd add protection for run numbers > 9999 (PSAS-111).
- PSQt:
- Add many classes for GUI and logger (PSAS-34).
- Implement signal and slot methods for communication between project objects, connect all parts of app in GUIMain.
- Improve memory management in GeometryAccess, GeometryObject, SegGeometryMatrixV1 -delete old objects before updates.
- xtcav:
- Improve island separation and delay calculation for 2-bunch mode. Fix bug where inter bunch delay function would fail for vectors with an odd number of elements.
- pypsalg:
- Add "values" method to histogram axis class (useful for plotting).
- live mode: add parameter to have psana wait for new runs in live mode (PSAS-108)
Deprecated Features
- o2o-translate has been removed from the release. Users needing to re-translate old data should use an old release. o2o-translate has hot been able to translate new DAQ types for a while.
- psana-translate non MPI split scan has been removed. It is no longer useful now that the MPI spilt scan translator has matured.
- psana-translate filtered groups have been removed. These groups kept track of events filtered from translation using the "do_not_translate" keyword that the Translator picks up. The feature was not required.
External Packages
- update to pdsdata 8.2.4 for EvrData DataV4.
- upgraded ROOT version from 5.30.6 to to 5.34.25 to resolve the previously discovered problem with IPython 2.4.1 if used together (PSAS-96)
Bugs fixed
- PSXtcInput: Do not look for configure transition in second chunk of an ioc recorder stream when in Index mode.
Known Issues