Setup & Diagnosing
The camrecorder process for recording EPICS camera data on a local disk runs on psrec01.
The PV is OTRS:DMP1:695:Image:ArrayData
Some instructions
ssh -X psrec01
To view recorded XTCAV data:
/reg/g/pcds/dist/pds/amo/ami-current/build/ami/bin/x86_64-linux-opt/offline_ami -p /u2/REC/daq
To check incoming XTCAV data:
bash
export EPICS_CA_AUTO_ADDR_LIST=NO
export EPICS_CA_ADDR_LIST=192.168.0.3
export EPICS_CA_SERVER_PORT=5068
export EPICS_CA_MAX_ARRAY_BYTES=10000000
camonitor -# 10 OTRS:DMP1:695:Image:ArrayData
caget OTRS:DMP1:695:Image:ArraySize0_RBV /* width */
caget OTRS:DMP1:695:Image:ArraySize1_RBV /* height */
We need to record additional information to properly analyze the XTCAV image:
Possibly BLD
BPMS:LTU1:250:X - Beam position (in X) at LTU1:250 (in mm)
BPMS:LTU1:450:X - Beam position (in X) at LTU1:450 (in mm)
BPMS:DMP1:502:TMIT - Bunch charge arriving in the electron dump (in
Nel)
TCAV:DMP1:360:ABR - XTCAV Amplitude (MV)
TCAV:DMP1:360:PBR - XTCAV Phase (deg)
Slow configuration data (1Hz in epicsArch)
SIOC:SYS0:ML01:AO216
OTRS:DMP1:695:TCAL_X
SIOC:SYS0:ML01:AO214
SIOC:SYS0:ML01:AO215
SIOC:SYS0:ML01:AO212
OTRS:DMP1:695:BLEN
SIOC:SYS0:ML01:AO213
Known Issues
The fiducial number (pulseID) recorded for this camera is late compared to the DAQ/BLD if the height of the readout image is too large (>330?).
2 Comments
Michael Browne