The XPP large detector is 4Mpx and 25kHz.  From Vincent: Two multimode MPO 24 fiber bundles per megapixel (8 bundles total) to the MM to SM conversion box. This means 8x24=192 fibers (96 pairs) which is 2 full SM-MM conversion box. (Aside: The SparkPix scales similarly with the number of pixels, so it only needs 24 fibers (1x MPO 24)).

Schedule (Nov. 2023): The deployment date for the detector in XPP is aimed to match the delivery of the SC beam, i.e. in 2027. Conny mentioned that they are also going to do some epixUHR tests at 35kHz at MFX next year with you, and that he's pushing to get a 1M version of the EpixUHR as soon as possible.

For TXI (2Mpx 5kHz) based on the epixhremu study from ric/stefano/valerio/mikhail/mona it feels like there is a good chance we can do it on 20 nodes with CPU (each with ~50 cores).  The XPP detector has 10x that data volume, and scaling to 200 nodes feels too difficult (although technology improvements may reduce that number somewhat, perhaps by 2x?).

Proposed approach: we should try to target GPUs for this to reduce the node count, ideally to 24 nodes: each node would take 1 LR4 multi-color fiber (the equivalent of 4 fiber pairs).  This is ~8GB/s into each node which is difficult with KCU1500 in our existing nodes, but will hopefully be doable in time for XPP.

If using 1 LR4 fiber per node isn't doable (i.e. we need more nodes) we should still use LR4 to reduce fiber-count in the BOS and use a SM-MM box in SRCF to split out the LR4 into more PLR4 fibers.

To-do items:

  • test common-mode speed on gpu (seshu has demonstrated Mikhail’s calibration formula without common-mode will be fast on a GPU)
  • we should meet with XPP scientists to understand what data-reduction algorithms are needed for their hutch
  • if libsz is one of the algorithms, we should understand its performance on gpu
  • benchmark other data-reduction algorithms on gpu
  • consider multiple options for algorithm implementation: cupy, cunumeric, cuda kernels
  • talk to TID engineers about dma'ing the kcu1500 (or c1100) data directly to gpu

Fred wrote: Regarding the bullet point “we should meet with XPP scientists to understand what data-reduction algorithms are needed for their hutch”, I just wanted to share an initial list since Valerio and I met with Vincent recently and what stood out was:

  • ROI (available in smalldata_tools)
  • Photonization (available in smalldata_tools; droplet algorithm could be faster on GPU)
  • Vetoing based on IPMs (available in smalldata_tools)
  • Azimuthal integration by bins (for SAXS/WAXS)
  • No labels