Content

2024-02-14 test for reduced resource consumption

After Wilko's test and mtg with AMD reps, it is assumed that the size of consumed memory is close to the threshold, which degrades performance. Let's try the same timing tests with replacement of float64 to 32 and 8-panel jungfrau to single-panel.

Description

Use the same resource consumption code as in Algorithm code with minor variation of code,  float64 replaced with 32, 8-panel jungfrau replaced with a single-panel.

Results

Per-CPU time consumption test for float64, sh2d=(8*512,1024)
float64
===================================================
python Detector/examples/test-scaling-subproc.py -1
python Detector/examples/test-scaling-subproc.py -1 10
python Detector/examples/test-scaling-subproc.py -1 64
python Detector/examples/test-scaling-subproc.py -1 127

python Detector/examples/test-scaling-subproc.py -2  > v8_1
python Detector/examples/test-scaling-subproc.py -8  > v16_1
python Detector/examples/test-scaling-subproc.py -13  > v32_1
python Detector/examples/test-scaling-subproc.py -17  > v64
python Detector/examples/test-scaling-subproc.py -18  > v120


ana-4.0.59-py3 [dubrovin@sdfmilan216:~/LCLS/con-py3]$ python Detector/examples/test-scaling-subproc.py -99
sys.argv: ['Detector/examples/test-scaling-subproc.py', '-99']
selector for mode: -99



sort_records_in_file: figs/fig-subpr-v1-sdfmilan216-summary.txt
records:
means: shape:(4,) size:4 dtype:float64
[0.17  0.171 0.174 0.174]
mean time (sec): 0.1723

hostname:sdfmilan216 cpu:005 cmt:v1 proc time (sec) mean: 0.170 +/- 0.038 rms: 0.051 +/- 0.027
hostname:sdfmilan216 cpu:010 cmt:v1 proc time (sec) mean: 0.171 +/- 0.040 rms: 0.051 +/- 0.028
hostname:sdfmilan216 cpu:064 cmt:v1 proc time (sec) mean: 0.174 +/- 0.047 rms: 0.052 +/- 0.033
hostname:sdfmilan216 cpu:127 cmt:v1 proc time (sec) mean: 0.174 +/- 0.046 rms: 0.052 +/- 0.033
mean time (sec): 0.1723
sort_records_in_file: figs/fig-subpr-v08-1-sdfmilan216-summary.txt
records:
means: shape:(8,) size:8 dtype:float64
[0.2   0.2   0.2   0.2   0.198 0.201 0.2   0.196]
mean time (sec): 0.1994

hostname:sdfmilan216 cpu:000 cmt:v08-1 proc time (sec) mean: 0.200 +/- 0.038 rms: 0.061 +/- 0.027
hostname:sdfmilan216 cpu:001 cmt:v08-1 proc time (sec) mean: 0.200 +/- 0.040 rms: 0.061 +/- 0.028
hostname:sdfmilan216 cpu:002 cmt:v08-1 proc time (sec) mean: 0.200 +/- 0.041 rms: 0.061 +/- 0.029
hostname:sdfmilan216 cpu:003 cmt:v08-1 proc time (sec) mean: 0.200 +/- 0.040 rms: 0.061 +/- 0.028
hostname:sdfmilan216 cpu:004 cmt:v08-1 proc time (sec) mean: 0.198 +/- 0.042 rms: 0.060 +/- 0.029
hostname:sdfmilan216 cpu:005 cmt:v08-1 proc time (sec) mean: 0.201 +/- 0.038 rms: 0.061 +/- 0.027
hostname:sdfmilan216 cpu:006 cmt:v08-1 proc time (sec) mean: 0.200 +/- 0.040 rms: 0.061 +/- 0.028
hostname:sdfmilan216 cpu:007 cmt:v08-1 proc time (sec) mean: 0.196 +/- 0.045 rms: 0.060 +/- 0.032
mean time (sec): 0.1994



sort_records_in_file: figs/fig-subpr-v16-1-sdfmilan216-summary.txt
records:
means: shape:(16,) size:16 dtype:float64
[0.258 0.25  0.253 0.255 0.254 0.254 0.258 0.256 0.261 0.259 0.256 0.254
 0.257 0.262 0.258 0.263]
mean time (sec): 0.2568

hostname:sdfmilan216 cpu:000 cmt:v16-1 proc time (sec) mean: 0.258 +/- 0.033 rms: 0.086 +/- 0.024
hostname:sdfmilan216 cpu:001 cmt:v16-1 proc time (sec) mean: 0.250 +/- 0.033 rms: 0.083 +/- 0.023
hostname:sdfmilan216 cpu:002 cmt:v16-1 proc time (sec) mean: 0.253 +/- 0.034 rms: 0.085 +/- 0.024
hostname:sdfmilan216 cpu:003 cmt:v16-1 proc time (sec) mean: 0.255 +/- 0.035 rms: 0.085 +/- 0.025
hostname:sdfmilan216 cpu:004 cmt:v16-1 proc time (sec) mean: 0.254 +/- 0.034 rms: 0.085 +/- 0.024
hostname:sdfmilan216 cpu:005 cmt:v16-1 proc time (sec) mean: 0.254 +/- 0.035 rms: 0.084 +/- 0.025
hostname:sdfmilan216 cpu:006 cmt:v16-1 proc time (sec) mean: 0.258 +/- 0.034 rms: 0.086 +/- 0.024
hostname:sdfmilan216 cpu:007 cmt:v16-1 proc time (sec) mean: 0.256 +/- 0.036 rms: 0.085 +/- 0.025
hostname:sdfmilan216 cpu:008 cmt:v16-1 proc time (sec) mean: 0.261 +/- 0.034 rms: 0.087 +/- 0.024
hostname:sdfmilan216 cpu:009 cmt:v16-1 proc time (sec) mean: 0.259 +/- 0.035 rms: 0.087 +/- 0.025
hostname:sdfmilan216 cpu:010 cmt:v16-1 proc time (sec) mean: 0.256 +/- 0.033 rms: 0.085 +/- 0.023
hostname:sdfmilan216 cpu:011 cmt:v16-1 proc time (sec) mean: 0.254 +/- 0.033 rms: 0.085 +/- 0.023
hostname:sdfmilan216 cpu:012 cmt:v16-1 proc time (sec) mean: 0.257 +/- 0.034 rms: 0.087 +/- 0.024
hostname:sdfmilan216 cpu:013 cmt:v16-1 proc time (sec) mean: 0.262 +/- 0.035 rms: 0.086 +/- 0.025
hostname:sdfmilan216 cpu:014 cmt:v16-1 proc time (sec) mean: 0.258 +/- 0.034 rms: 0.086 +/- 0.024
hostname:sdfmilan216 cpu:015 cmt:v16-1 proc time (sec) mean: 0.263 +/- 0.033 rms: 0.088 +/- 0.024
mean time (sec): 0.2568



sort_records_in_file: figs/fig-subpr-v32-1-sdfmilan216-summary.txt
records:
means: shape:(32,) size:32 dtype:float64
[0.257 0.262 0.262 0.263 0.258 0.26  0.258 0.27  0.262 0.26  0.263 0.266
 0.265 0.268 0.262 0.265 0.253 0.254 0.263 0.259 0.257 0.26  0.253 0.255
 0.258 0.256 0.253 0.256 0.257 0.259 0.258 0.254]
mean time (sec): 0.2596

hostname:sdfmilan216 cpu:032 cmt:v32-1 proc time (sec) mean: 0.257 +/- 0.037 rms: 0.087 +/- 0.026
hostname:sdfmilan216 cpu:033 cmt:v32-1 proc time (sec) mean: 0.262 +/- 0.036 rms: 0.090 +/- 0.026
hostname:sdfmilan216 cpu:034 cmt:v32-1 proc time (sec) mean: 0.262 +/- 0.038 rms: 0.090 +/- 0.027
hostname:sdfmilan216 cpu:035 cmt:v32-1 proc time (sec) mean: 0.263 +/- 0.036 rms: 0.089 +/- 0.025
hostname:sdfmilan216 cpu:036 cmt:v32-1 proc time (sec) mean: 0.258 +/- 0.037 rms: 0.087 +/- 0.026
hostname:sdfmilan216 cpu:037 cmt:v32-1 proc time (sec) mean: 0.260 +/- 0.036 rms: 0.088 +/- 0.026
hostname:sdfmilan216 cpu:038 cmt:v32-1 proc time (sec) mean: 0.258 +/- 0.038 rms: 0.087 +/- 0.027
hostname:sdfmilan216 cpu:039 cmt:v32-1 proc time (sec) mean: 0.270 +/- 0.035 rms: 0.090 +/- 0.025
hostname:sdfmilan216 cpu:040 cmt:v32-1 proc time (sec) mean: 0.262 +/- 0.037 rms: 0.088 +/- 0.026
hostname:sdfmilan216 cpu:041 cmt:v32-1 proc time (sec) mean: 0.260 +/- 0.037 rms: 0.088 +/- 0.026
hostname:sdfmilan216 cpu:042 cmt:v32-1 proc time (sec) mean: 0.263 +/- 0.036 rms: 0.090 +/- 0.025
hostname:sdfmilan216 cpu:043 cmt:v32-1 proc time (sec) mean: 0.266 +/- 0.037 rms: 0.092 +/- 0.026
hostname:sdfmilan216 cpu:044 cmt:v32-1 proc time (sec) mean: 0.265 +/- 0.035 rms: 0.089 +/- 0.025
hostname:sdfmilan216 cpu:045 cmt:v32-1 proc time (sec) mean: 0.268 +/- 0.037 rms: 0.091 +/- 0.026
hostname:sdfmilan216 cpu:046 cmt:v32-1 proc time (sec) mean: 0.262 +/- 0.035 rms: 0.089 +/- 0.025
hostname:sdfmilan216 cpu:047 cmt:v32-1 proc time (sec) mean: 0.265 +/- 0.035 rms: 0.090 +/- 0.025
hostname:sdfmilan216 cpu:048 cmt:v32-1 proc time (sec) mean: 0.253 +/- 0.037 rms: 0.082 +/- 0.026
hostname:sdfmilan216 cpu:049 cmt:v32-1 proc time (sec) mean: 0.254 +/- 0.036 rms: 0.082 +/- 0.025
hostname:sdfmilan216 cpu:050 cmt:v32-1 proc time (sec) mean: 0.263 +/- 0.036 rms: 0.086 +/- 0.025
hostname:sdfmilan216 cpu:051 cmt:v32-1 proc time (sec) mean: 0.259 +/- 0.038 rms: 0.084 +/- 0.027
hostname:sdfmilan216 cpu:052 cmt:v32-1 proc time (sec) mean: 0.257 +/- 0.037 rms: 0.083 +/- 0.026
hostname:sdfmilan216 cpu:053 cmt:v32-1 proc time (sec) mean: 0.260 +/- 0.035 rms: 0.085 +/- 0.025
hostname:sdfmilan216 cpu:054 cmt:v32-1 proc time (sec) mean: 0.253 +/- 0.040 rms: 0.082 +/- 0.028
hostname:sdfmilan216 cpu:055 cmt:v32-1 proc time (sec) mean: 0.255 +/- 0.039 rms: 0.083 +/- 0.027
hostname:sdfmilan216 cpu:056 cmt:v32-1 proc time (sec) mean: 0.258 +/- 0.040 rms: 0.082 +/- 0.028
hostname:sdfmilan216 cpu:057 cmt:v32-1 proc time (sec) mean: 0.256 +/- 0.040 rms: 0.083 +/- 0.028
hostname:sdfmilan216 cpu:058 cmt:v32-1 proc time (sec) mean: 0.253 +/- 0.037 rms: 0.082 +/- 0.026
hostname:sdfmilan216 cpu:059 cmt:v32-1 proc time (sec) mean: 0.256 +/- 0.035 rms: 0.083 +/- 0.025
hostname:sdfmilan216 cpu:060 cmt:v32-1 proc time (sec) mean: 0.257 +/- 0.037 rms: 0.083 +/- 0.026
hostname:sdfmilan216 cpu:061 cmt:v32-1 proc time (sec) mean: 0.259 +/- 0.039 rms: 0.084 +/- 0.027
hostname:sdfmilan216 cpu:062 cmt:v32-1 proc time (sec) mean: 0.258 +/- 0.039 rms: 0.084 +/- 0.028
hostname:sdfmilan216 cpu:063 cmt:v32-1 proc time (sec) mean: 0.254 +/- 0.037 rms: 0.082 +/- 0.026
mean time (sec): 0.2596



sort_records_in_file: figs/fig-subpr-v64-sdfmilan216-summary.txt
records:
means: shape:(64,) size:64 dtype:float64
[0.736 0.748 0.752 0.74  0.749 0.749 0.742 0.741 0.741 0.738 0.734 0.747
 0.75  0.743 0.74  0.748 0.61  0.605 0.612 0.606 0.614 0.611 0.622 0.617
 0.652 0.631 0.644 0.651 0.676 0.654 0.655 0.655 0.295 0.29  0.298 0.287
 0.302 0.297 0.294 0.301 0.296 0.291 0.296 0.293 0.294 0.294 0.301 0.295
 0.302 0.307 0.295 0.3   0.317 0.289 0.295 0.309 0.312 0.292 0.309 0.301
 0.32  0.291 0.305 0.31 ]
mean time (sec): 0.4936

hostname:sdfmilan216 cpu:064 cmt:v64 proc time (sec) mean: 0.736 +/- 0.062 rms: 0.294 +/- 0.044
hostname:sdfmilan216 cpu:065 cmt:v64 proc time (sec) mean: 0.748 +/- 0.069 rms: 0.296 +/- 0.049
hostname:sdfmilan216 cpu:066 cmt:v64 proc time (sec) mean: 0.752 +/- 0.066 rms: 0.290 +/- 0.047
hostname:sdfmilan216 cpu:067 cmt:v64 proc time (sec) mean: 0.740 +/- 0.070 rms: 0.289 +/- 0.050
hostname:sdfmilan216 cpu:068 cmt:v64 proc time (sec) mean: 0.749 +/- 0.070 rms: 0.295 +/- 0.049
hostname:sdfmilan216 cpu:069 cmt:v64 proc time (sec) mean: 0.749 +/- 0.065 rms: 0.287 +/- 0.046
hostname:sdfmilan216 cpu:070 cmt:v64 proc time (sec) mean: 0.742 +/- 0.068 rms: 0.293 +/- 0.048
hostname:sdfmilan216 cpu:071 cmt:v64 proc time (sec) mean: 0.741 +/- 0.064 rms: 0.282 +/- 0.045
hostname:sdfmilan216 cpu:072 cmt:v64 proc time (sec) mean: 0.741 +/- 0.060 rms: 0.286 +/- 0.042
hostname:sdfmilan216 cpu:073 cmt:v64 proc time (sec) mean: 0.738 +/- 0.062 rms: 0.291 +/- 0.044
hostname:sdfmilan216 cpu:074 cmt:v64 proc time (sec) mean: 0.734 +/- 0.062 rms: 0.279 +/- 0.044
hostname:sdfmilan216 cpu:075 cmt:v64 proc time (sec) mean: 0.747 +/- 0.067 rms: 0.294 +/- 0.047
hostname:sdfmilan216 cpu:076 cmt:v64 proc time (sec) mean: 0.750 +/- 0.066 rms: 0.287 +/- 0.047
hostname:sdfmilan216 cpu:077 cmt:v64 proc time (sec) mean: 0.743 +/- 0.062 rms: 0.295 +/- 0.044
hostname:sdfmilan216 cpu:078 cmt:v64 proc time (sec) mean: 0.740 +/- 0.063 rms: 0.287 +/- 0.044
hostname:sdfmilan216 cpu:079 cmt:v64 proc time (sec) mean: 0.748 +/- 0.069 rms: 0.286 +/- 0.048
hostname:sdfmilan216 cpu:080 cmt:v64 proc time (sec) mean: 0.610 +/- 0.053 rms: 0.214 +/- 0.037
hostname:sdfmilan216 cpu:081 cmt:v64 proc time (sec) mean: 0.605 +/- 0.053 rms: 0.217 +/- 0.037
hostname:sdfmilan216 cpu:082 cmt:v64 proc time (sec) mean: 0.612 +/- 0.053 rms: 0.217 +/- 0.038
hostname:sdfmilan216 cpu:083 cmt:v64 proc time (sec) mean: 0.606 +/- 0.054 rms: 0.217 +/- 0.038
hostname:sdfmilan216 cpu:084 cmt:v64 proc time (sec) mean: 0.614 +/- 0.053 rms: 0.213 +/- 0.037
hostname:sdfmilan216 cpu:085 cmt:v64 proc time (sec) mean: 0.611 +/- 0.051 rms: 0.221 +/- 0.036
hostname:sdfmilan216 cpu:086 cmt:v64 proc time (sec) mean: 0.622 +/- 0.054 rms: 0.220 +/- 0.038
hostname:sdfmilan216 cpu:087 cmt:v64 proc time (sec) mean: 0.617 +/- 0.054 rms: 0.215 +/- 0.038
hostname:sdfmilan216 cpu:088 cmt:v64 proc time (sec) mean: 0.652 +/- 0.060 rms: 0.240 +/- 0.043
hostname:sdfmilan216 cpu:089 cmt:v64 proc time (sec) mean: 0.631 +/- 0.056 rms: 0.241 +/- 0.040
hostname:sdfmilan216 cpu:090 cmt:v64 proc time (sec) mean: 0.644 +/- 0.059 rms: 0.241 +/- 0.042
hostname:sdfmilan216 cpu:091 cmt:v64 proc time (sec) mean: 0.651 +/- 0.059 rms: 0.247 +/- 0.042
hostname:sdfmilan216 cpu:092 cmt:v64 proc time (sec) mean: 0.676 +/- 0.064 rms: 0.233 +/- 0.045
hostname:sdfmilan216 cpu:093 cmt:v64 proc time (sec) mean: 0.654 +/- 0.058 rms: 0.240 +/- 0.041
hostname:sdfmilan216 cpu:094 cmt:v64 proc time (sec) mean: 0.655 +/- 0.060 rms: 0.243 +/- 0.043
hostname:sdfmilan216 cpu:095 cmt:v64 proc time (sec) mean: 0.655 +/- 0.060 rms: 0.235 +/- 0.043
hostname:sdfmilan216 cpu:096 cmt:v64 proc time (sec) mean: 0.295 +/- 0.036 rms: 0.110 +/- 0.026
hostname:sdfmilan216 cpu:097 cmt:v64 proc time (sec) mean: 0.290 +/- 0.037 rms: 0.108 +/- 0.026
hostname:sdfmilan216 cpu:098 cmt:v64 proc time (sec) mean: 0.298 +/- 0.036 rms: 0.111 +/- 0.026
hostname:sdfmilan216 cpu:099 cmt:v64 proc time (sec) mean: 0.287 +/- 0.036 rms: 0.105 +/- 0.025
hostname:sdfmilan216 cpu:100 cmt:v64 proc time (sec) mean: 0.302 +/- 0.035 rms: 0.111 +/- 0.025
hostname:sdfmilan216 cpu:101 cmt:v64 proc time (sec) mean: 0.297 +/- 0.036 rms: 0.110 +/- 0.026
hostname:sdfmilan216 cpu:102 cmt:v64 proc time (sec) mean: 0.294 +/- 0.035 rms: 0.103 +/- 0.025
hostname:sdfmilan216 cpu:103 cmt:v64 proc time (sec) mean: 0.301 +/- 0.035 rms: 0.109 +/- 0.025
hostname:sdfmilan216 cpu:104 cmt:v64 proc time (sec) mean: 0.296 +/- 0.033 rms: 0.104 +/- 0.023
hostname:sdfmilan216 cpu:105 cmt:v64 proc time (sec) mean: 0.291 +/- 0.035 rms: 0.106 +/- 0.025
hostname:sdfmilan216 cpu:106 cmt:v64 proc time (sec) mean: 0.296 +/- 0.034 rms: 0.105 +/- 0.024
hostname:sdfmilan216 cpu:107 cmt:v64 proc time (sec) mean: 0.293 +/- 0.034 rms: 0.102 +/- 0.024
hostname:sdfmilan216 cpu:108 cmt:v64 proc time (sec) mean: 0.294 +/- 0.036 rms: 0.107 +/- 0.026
hostname:sdfmilan216 cpu:109 cmt:v64 proc time (sec) mean: 0.294 +/- 0.034 rms: 0.102 +/- 0.024
hostname:sdfmilan216 cpu:110 cmt:v64 proc time (sec) mean: 0.301 +/- 0.035 rms: 0.110 +/- 0.025
hostname:sdfmilan216 cpu:111 cmt:v64 proc time (sec) mean: 0.295 +/- 0.035 rms: 0.109 +/- 0.025
hostname:sdfmilan216 cpu:112 cmt:v64 proc time (sec) mean: 0.302 +/- 0.035 rms: 0.110 +/- 0.025
hostname:sdfmilan216 cpu:113 cmt:v64 proc time (sec) mean: 0.307 +/- 0.034 rms: 0.115 +/- 0.024
hostname:sdfmilan216 cpu:114 cmt:v64 proc time (sec) mean: 0.295 +/- 0.037 rms: 0.109 +/- 0.026
hostname:sdfmilan216 cpu:115 cmt:v64 proc time (sec) mean: 0.300 +/- 0.036 rms: 0.112 +/- 0.025
hostname:sdfmilan216 cpu:116 cmt:v64 proc time (sec) mean: 0.317 +/- 0.034 rms: 0.115 +/- 0.024
hostname:sdfmilan216 cpu:117 cmt:v64 proc time (sec) mean: 0.289 +/- 0.039 rms: 0.104 +/- 0.027
hostname:sdfmilan216 cpu:118 cmt:v64 proc time (sec) mean: 0.295 +/- 0.038 rms: 0.106 +/- 0.027
hostname:sdfmilan216 cpu:119 cmt:v64 proc time (sec) mean: 0.309 +/- 0.037 rms: 0.116 +/- 0.026
hostname:sdfmilan216 cpu:120 cmt:v64 proc time (sec) mean: 0.312 +/- 0.034 rms: 0.113 +/- 0.024
hostname:sdfmilan216 cpu:121 cmt:v64 proc time (sec) mean: 0.292 +/- 0.037 rms: 0.109 +/- 0.026
hostname:sdfmilan216 cpu:122 cmt:v64 proc time (sec) mean: 0.309 +/- 0.034 rms: 0.111 +/- 0.024
hostname:sdfmilan216 cpu:123 cmt:v64 proc time (sec) mean: 0.301 +/- 0.035 rms: 0.108 +/- 0.024
hostname:sdfmilan216 cpu:124 cmt:v64 proc time (sec) mean: 0.320 +/- 0.036 rms: 0.118 +/- 0.025
hostname:sdfmilan216 cpu:125 cmt:v64 proc time (sec) mean: 0.291 +/- 0.039 rms: 0.106 +/- 0.027
hostname:sdfmilan216 cpu:126 cmt:v64 proc time (sec) mean: 0.305 +/- 0.038 rms: 0.108 +/- 0.027
hostname:sdfmilan216 cpu:127 cmt:v64 proc time (sec) mean: 0.310 +/- 0.037 rms: 0.120 +/- 0.026
mean time (sec): 0.4936



sort_records_in_file: figs/fig-subpr-v120-sdfmilan216-summary.txt
records:
means: shape:(120,) size:120 dtype:float64
[0.278 0.275 0.269 0.276 0.272 0.27  0.282 0.277 0.264 0.277 0.266 0.273
 0.273 0.272 0.268 0.278 0.253 0.252 0.255 0.249 0.251 0.254 0.249 0.247
 0.276 0.272 0.27  0.274 0.272 0.272 0.268 0.275 0.279 0.274 0.276 0.274
 0.271 0.277 0.276 0.272 0.274 0.272 0.27  0.276 0.275 0.276 0.276 0.271
 0.277 0.269 0.273 0.266 0.27  0.272 0.273 0.275 0.722 0.731 0.736 0.712
 0.707 0.719 0.722 0.725 0.746 0.737 0.743 0.75  0.742 0.746 0.74  0.723
 0.552 0.567 0.57  0.568 0.566 0.566 0.565 0.575 0.636 0.626 0.64  0.649
 0.667 0.683 0.664 0.67  0.272 0.27  0.273 0.267 0.26  0.273 0.276 0.265
 0.282 0.285 0.271 0.277...]
mean time (sec): 0.3787

hostname:sdfmilan216 cpu:000 cmt:v120 proc time (sec) mean: 0.278 +/- 0.050 rms: 0.091 +/- 0.035
hostname:sdfmilan216 cpu:001 cmt:v120 proc time (sec) mean: 0.275 +/- 0.046 rms: 0.085 +/- 0.033
hostname:sdfmilan216 cpu:002 cmt:v120 proc time (sec) mean: 0.269 +/- 0.048 rms: 0.083 +/- 0.034
hostname:sdfmilan216 cpu:003 cmt:v120 proc time (sec) mean: 0.276 +/- 0.048 rms: 0.085 +/- 0.034
hostname:sdfmilan216 cpu:004 cmt:v120 proc time (sec) mean: 0.272 +/- 0.048 rms: 0.084 +/- 0.034
hostname:sdfmilan216 cpu:005 cmt:v120 proc time (sec) mean: 0.270 +/- 0.052 rms: 0.083 +/- 0.037
hostname:sdfmilan216 cpu:006 cmt:v120 proc time (sec) mean: 0.282 +/- 0.048 rms: 0.088 +/- 0.034
hostname:sdfmilan216 cpu:007 cmt:v120 proc time (sec) mean: 0.277 +/- 0.050 rms: 0.087 +/- 0.035
hostname:sdfmilan216 cpu:008 cmt:v120 proc time (sec) mean: 0.264 +/- 0.046 rms: 0.081 +/- 0.032
hostname:sdfmilan216 cpu:009 cmt:v120 proc time (sec) mean: 0.277 +/- 0.047 rms: 0.085 +/- 0.033
hostname:sdfmilan216 cpu:010 cmt:v120 proc time (sec) mean: 0.266 +/- 0.049 rms: 0.082 +/- 0.035
hostname:sdfmilan216 cpu:011 cmt:v120 proc time (sec) mean: 0.273 +/- 0.050 rms: 0.084 +/- 0.036
hostname:sdfmilan216 cpu:012 cmt:v120 proc time (sec) mean: 0.273 +/- 0.053 rms: 0.084 +/- 0.037
hostname:sdfmilan216 cpu:013 cmt:v120 proc time (sec) mean: 0.272 +/- 0.049 rms: 0.084 +/- 0.035
hostname:sdfmilan216 cpu:014 cmt:v120 proc time (sec) mean: 0.268 +/- 0.053 rms: 0.082 +/- 0.038
hostname:sdfmilan216 cpu:015 cmt:v120 proc time (sec) mean: 0.278 +/- 0.045 rms: 0.086 +/- 0.032
hostname:sdfmilan216 cpu:024 cmt:v120 proc time (sec) mean: 0.253 +/- 0.052 rms: 0.077 +/- 0.037
hostname:sdfmilan216 cpu:025 cmt:v120 proc time (sec) mean: 0.252 +/- 0.054 rms: 0.077 +/- 0.038
hostname:sdfmilan216 cpu:026 cmt:v120 proc time (sec) mean: 0.255 +/- 0.049 rms: 0.078 +/- 0.035
hostname:sdfmilan216 cpu:027 cmt:v120 proc time (sec) mean: 0.249 +/- 0.062 rms: 0.075 +/- 0.044
hostname:sdfmilan216 cpu:028 cmt:v120 proc time (sec) mean: 0.251 +/- 0.057 rms: 0.076 +/- 0.040
hostname:sdfmilan216 cpu:029 cmt:v120 proc time (sec) mean: 0.254 +/- 0.051 rms: 0.077 +/- 0.036
hostname:sdfmilan216 cpu:030 cmt:v120 proc time (sec) mean: 0.249 +/- 0.060 rms: 0.075 +/- 0.043
hostname:sdfmilan216 cpu:031 cmt:v120 proc time (sec) mean: 0.247 +/- 0.062 rms: 0.075 +/- 0.044
hostname:sdfmilan216 cpu:032 cmt:v120 proc time (sec) mean: 0.276 +/- 0.048 rms: 0.086 +/- 0.034
hostname:sdfmilan216 cpu:033 cmt:v120 proc time (sec) mean: 0.272 +/- 0.050 rms: 0.085 +/- 0.035
hostname:sdfmilan216 cpu:034 cmt:v120 proc time (sec) mean: 0.270 +/- 0.046 rms: 0.084 +/- 0.033
hostname:sdfmilan216 cpu:035 cmt:v120 proc time (sec) mean: 0.274 +/- 0.048 rms: 0.084 +/- 0.034
hostname:sdfmilan216 cpu:036 cmt:v120 proc time (sec) mean: 0.272 +/- 0.050 rms: 0.083 +/- 0.035
hostname:sdfmilan216 cpu:037 cmt:v120 proc time (sec) mean: 0.272 +/- 0.045 rms: 0.085 +/- 0.032
hostname:sdfmilan216 cpu:038 cmt:v120 proc time (sec) mean: 0.268 +/- 0.048 rms: 0.082 +/- 0.034
hostname:sdfmilan216 cpu:039 cmt:v120 proc time (sec) mean: 0.275 +/- 0.048 rms: 0.085 +/- 0.034
hostname:sdfmilan216 cpu:040 cmt:v120 proc time (sec) mean: 0.279 +/- 0.046 rms: 0.088 +/- 0.032
hostname:sdfmilan216 cpu:041 cmt:v120 proc time (sec) mean: 0.274 +/- 0.049 rms: 0.085 +/- 0.034
hostname:sdfmilan216 cpu:042 cmt:v120 proc time (sec) mean: 0.276 +/- 0.045 rms: 0.086 +/- 0.032
hostname:sdfmilan216 cpu:043 cmt:v120 proc time (sec) mean: 0.274 +/- 0.049 rms: 0.084 +/- 0.035
hostname:sdfmilan216 cpu:044 cmt:v120 proc time (sec) mean: 0.271 +/- 0.049 rms: 0.083 +/- 0.035
hostname:sdfmilan216 cpu:045 cmt:v120 proc time (sec) mean: 0.277 +/- 0.049 rms: 0.090 +/- 0.035
hostname:sdfmilan216 cpu:046 cmt:v120 proc time (sec) mean: 0.276 +/- 0.049 rms: 0.086 +/- 0.034
hostname:sdfmilan216 cpu:047 cmt:v120 proc time (sec) mean: 0.272 +/- 0.049 rms: 0.084 +/- 0.034
hostname:sdfmilan216 cpu:048 cmt:v120 proc time (sec) mean: 0.274 +/- 0.051 rms: 0.084 +/- 0.036
hostname:sdfmilan216 cpu:049 cmt:v120 proc time (sec) mean: 0.272 +/- 0.048 rms: 0.084 +/- 0.034
hostname:sdfmilan216 cpu:050 cmt:v120 proc time (sec) mean: 0.270 +/- 0.046 rms: 0.083 +/- 0.032
hostname:sdfmilan216 cpu:051 cmt:v120 proc time (sec) mean: 0.276 +/- 0.045 rms: 0.085 +/- 0.032
hostname:sdfmilan216 cpu:052 cmt:v120 proc time (sec) mean: 0.275 +/- 0.048 rms: 0.085 +/- 0.034
hostname:sdfmilan216 cpu:053 cmt:v120 proc time (sec) mean: 0.276 +/- 0.053 rms: 0.084 +/- 0.037
hostname:sdfmilan216 cpu:054 cmt:v120 proc time (sec) mean: 0.276 +/- 0.049 rms: 0.085 +/- 0.034
hostname:sdfmilan216 cpu:055 cmt:v120 proc time (sec) mean: 0.271 +/- 0.050 rms: 0.083 +/- 0.035
hostname:sdfmilan216 cpu:056 cmt:v120 proc time (sec) mean: 0.277 +/- 0.048 rms: 0.086 +/- 0.034
hostname:sdfmilan216 cpu:057 cmt:v120 proc time (sec) mean: 0.269 +/- 0.050 rms: 0.082 +/- 0.035
hostname:sdfmilan216 cpu:058 cmt:v120 proc time (sec) mean: 0.273 +/- 0.052 rms: 0.084 +/- 0.037
hostname:sdfmilan216 cpu:059 cmt:v120 proc time (sec) mean: 0.266 +/- 0.051 rms: 0.081 +/- 0.036
hostname:sdfmilan216 cpu:060 cmt:v120 proc time (sec) mean: 0.270 +/- 0.048 rms: 0.083 +/- 0.034
hostname:sdfmilan216 cpu:061 cmt:v120 proc time (sec) mean: 0.272 +/- 0.049 rms: 0.084 +/- 0.035
hostname:sdfmilan216 cpu:062 cmt:v120 proc time (sec) mean: 0.273 +/- 0.049 rms: 0.084 +/- 0.035
hostname:sdfmilan216 cpu:063 cmt:v120 proc time (sec) mean: 0.275 +/- 0.049 rms: 0.085 +/- 0.035
hostname:sdfmilan216 cpu:064 cmt:v120 proc time (sec) mean: 0.722 +/- 0.065 rms: 0.277 +/- 0.046
hostname:sdfmilan216 cpu:065 cmt:v120 proc time (sec) mean: 0.731 +/- 0.065 rms: 0.288 +/- 0.046
hostname:sdfmilan216 cpu:066 cmt:v120 proc time (sec) mean: 0.736 +/- 0.072 rms: 0.288 +/- 0.051
hostname:sdfmilan216 cpu:067 cmt:v120 proc time (sec) mean: 0.712 +/- 0.065 rms: 0.280 +/- 0.046
hostname:sdfmilan216 cpu:068 cmt:v120 proc time (sec) mean: 0.707 +/- 0.059 rms: 0.272 +/- 0.042
hostname:sdfmilan216 cpu:069 cmt:v120 proc time (sec) mean: 0.719 +/- 0.065 rms: 0.275 +/- 0.046
hostname:sdfmilan216 cpu:070 cmt:v120 proc time (sec) mean: 0.722 +/- 0.065 rms: 0.278 +/- 0.046
hostname:sdfmilan216 cpu:071 cmt:v120 proc time (sec) mean: 0.725 +/- 0.070 rms: 0.277 +/- 0.049
hostname:sdfmilan216 cpu:072 cmt:v120 proc time (sec) mean: 0.746 +/- 0.070 rms: 0.289 +/- 0.050
hostname:sdfmilan216 cpu:073 cmt:v120 proc time (sec) mean: 0.737 +/- 0.062 rms: 0.289 +/- 0.044
hostname:sdfmilan216 cpu:074 cmt:v120 proc time (sec) mean: 0.743 +/- 0.062 rms: 0.284 +/- 0.044
hostname:sdfmilan216 cpu:075 cmt:v120 proc time (sec) mean: 0.750 +/- 0.064 rms: 0.300 +/- 0.045
hostname:sdfmilan216 cpu:076 cmt:v120 proc time (sec) mean: 0.742 +/- 0.064 rms: 0.291 +/- 0.045
hostname:sdfmilan216 cpu:077 cmt:v120 proc time (sec) mean: 0.746 +/- 0.067 rms: 0.295 +/- 0.048
hostname:sdfmilan216 cpu:078 cmt:v120 proc time (sec) mean: 0.740 +/- 0.061 rms: 0.289 +/- 0.043
hostname:sdfmilan216 cpu:079 cmt:v120 proc time (sec) mean: 0.723 +/- 0.063 rms: 0.277 +/- 0.044
hostname:sdfmilan216 cpu:080 cmt:v120 proc time (sec) mean: 0.552 +/- 0.056 rms: 0.191 +/- 0.040
hostname:sdfmilan216 cpu:081 cmt:v120 proc time (sec) mean: 0.567 +/- 0.051 rms: 0.193 +/- 0.036
hostname:sdfmilan216 cpu:082 cmt:v120 proc time (sec) mean: 0.570 +/- 0.051 rms: 0.196 +/- 0.036
hostname:sdfmilan216 cpu:083 cmt:v120 proc time (sec) mean: 0.568 +/- 0.051 rms: 0.196 +/- 0.036
hostname:sdfmilan216 cpu:084 cmt:v120 proc time (sec) mean: 0.566 +/- 0.052 rms: 0.196 +/- 0.037
hostname:sdfmilan216 cpu:085 cmt:v120 proc time (sec) mean: 0.566 +/- 0.053 rms: 0.192 +/- 0.038
hostname:sdfmilan216 cpu:086 cmt:v120 proc time (sec) mean: 0.565 +/- 0.053 rms: 0.195 +/- 0.037
hostname:sdfmilan216 cpu:087 cmt:v120 proc time (sec) mean: 0.575 +/- 0.053 rms: 0.197 +/- 0.037
hostname:sdfmilan216 cpu:088 cmt:v120 proc time (sec) mean: 0.636 +/- 0.060 rms: 0.234 +/- 0.043
hostname:sdfmilan216 cpu:089 cmt:v120 proc time (sec) mean: 0.626 +/- 0.058 rms: 0.232 +/- 0.041
hostname:sdfmilan216 cpu:090 cmt:v120 proc time (sec) mean: 0.640 +/- 0.061 rms: 0.231 +/- 0.043
hostname:sdfmilan216 cpu:091 cmt:v120 proc time (sec) mean: 0.649 +/- 0.063 rms: 0.235 +/- 0.044
hostname:sdfmilan216 cpu:092 cmt:v120 proc time (sec) mean: 0.667 +/- 0.069 rms: 0.231 +/- 0.049
hostname:sdfmilan216 cpu:093 cmt:v120 proc time (sec) mean: 0.683 +/- 0.069 rms: 0.229 +/- 0.049
hostname:sdfmilan216 cpu:094 cmt:v120 proc time (sec) mean: 0.664 +/- 0.063 rms: 0.231 +/- 0.045
hostname:sdfmilan216 cpu:095 cmt:v120 proc time (sec) mean: 0.670 +/- 0.066 rms: 0.228 +/- 0.046
hostname:sdfmilan216 cpu:096 cmt:v120 proc time (sec) mean: 0.272 +/- 0.037 rms: 0.090 +/- 0.026
hostname:sdfmilan216 cpu:097 cmt:v120 proc time (sec) mean: 0.270 +/- 0.039 rms: 0.087 +/- 0.027
hostname:sdfmilan216 cpu:098 cmt:v120 proc time (sec) mean: 0.273 +/- 0.038 rms: 0.091 +/- 0.027
hostname:sdfmilan216 cpu:099 cmt:v120 proc time (sec) mean: 0.267 +/- 0.038 rms: 0.088 +/- 0.027
hostname:sdfmilan216 cpu:100 cmt:v120 proc time (sec) mean: 0.260 +/- 0.041 rms: 0.082 +/- 0.029
hostname:sdfmilan216 cpu:101 cmt:v120 proc time (sec) mean: 0.273 +/- 0.036 rms: 0.090 +/- 0.026
hostname:sdfmilan216 cpu:102 cmt:v120 proc time (sec) mean: 0.276 +/- 0.041 rms: 0.091 +/- 0.029
hostname:sdfmilan216 cpu:103 cmt:v120 proc time (sec) mean: 0.265 +/- 0.037 rms: 0.084 +/- 0.026
hostname:sdfmilan216 cpu:104 cmt:v120 proc time (sec) mean: 0.282 +/- 0.037 rms: 0.094 +/- 0.026
hostname:sdfmilan216 cpu:105 cmt:v120 proc time (sec) mean: 0.285 +/- 0.039 rms: 0.092 +/- 0.028
hostname:sdfmilan216 cpu:106 cmt:v120 proc time (sec) mean: 0.271 +/- 0.038 rms: 0.089 +/- 0.027
hostname:sdfmilan216 cpu:107 cmt:v120 proc time (sec) mean: 0.277 +/- 0.040 rms: 0.093 +/- 0.028
hostname:sdfmilan216 cpu:108 cmt:v120 proc time (sec) mean: 0.271 +/- 0.042 rms: 0.089 +/- 0.029
hostname:sdfmilan216 cpu:109 cmt:v120 proc time (sec) mean: 0.270 +/- 0.039 rms: 0.087 +/- 0.027
hostname:sdfmilan216 cpu:110 cmt:v120 proc time (sec) mean: 0.277 +/- 0.040 rms: 0.093 +/- 0.028
hostname:sdfmilan216 cpu:111 cmt:v120 proc time (sec) mean: 0.277 +/- 0.038 rms: 0.092 +/- 0.027
hostname:sdfmilan216 cpu:112 cmt:v120 proc time (sec) mean: 0.273 +/- 0.039 rms: 0.091 +/- 0.027
hostname:sdfmilan216 cpu:113 cmt:v120 proc time (sec) mean: 0.278 +/- 0.039 rms: 0.101 +/- 0.028
hostname:sdfmilan216 cpu:114 cmt:v120 proc time (sec) mean: 0.277 +/- 0.037 rms: 0.095 +/- 0.026
hostname:sdfmilan216 cpu:115 cmt:v120 proc time (sec) mean: 0.272 +/- 0.036 rms: 0.090 +/- 0.026
hostname:sdfmilan216 cpu:116 cmt:v120 proc time (sec) mean: 0.287 +/- 0.036 rms: 0.097 +/- 0.025
hostname:sdfmilan216 cpu:117 cmt:v120 proc time (sec) mean: 0.283 +/- 0.038 rms: 0.098 +/- 0.027
hostname:sdfmilan216 cpu:118 cmt:v120 proc time (sec) mean: 0.280 +/- 0.036 rms: 0.094 +/- 0.025
hostname:sdfmilan216 cpu:119 cmt:v120 proc time (sec) mean: 0.279 +/- 0.037 rms: 0.091 +/- 0.026
hostname:sdfmilan216 cpu:120 cmt:v120 proc time (sec) mean: 0.283 +/- 0.034 rms: 0.093 +/- 0.024
hostname:sdfmilan216 cpu:121 cmt:v120 proc time (sec) mean: 0.272 +/- 0.039 rms: 0.086 +/- 0.028
hostname:sdfmilan216 cpu:122 cmt:v120 proc time (sec) mean: 0.280 +/- 0.035 rms: 0.091 +/- 0.025
hostname:sdfmilan216 cpu:123 cmt:v120 proc time (sec) mean: 0.288 +/- 0.034 rms: 0.097 +/- 0.024
hostname:sdfmilan216 cpu:124 cmt:v120 proc time (sec) mean: 0.289 +/- 0.036 rms: 0.100 +/- 0.025
hostname:sdfmilan216 cpu:125 cmt:v120 proc time (sec) mean: 0.284 +/- 0.037 rms: 0.100 +/- 0.026
hostname:sdfmilan216 cpu:126 cmt:v120 proc time (sec) mean: 0.275 +/- 0.037 rms: 0.093 +/- 0.026
hostname:sdfmilan216 cpu:127 cmt:v120 proc time (sec) mean: 0.288 +/- 0.038 rms: 0.094 +/- 0.027
mean time (sec): 0.3787
ana-4.0.59-py3 [dubrovin@sdfmilan216:~/LCLS/con-py3]$ 
Per-CPU time consumption test for float32, sh2d=(8*512,1024)
float64 > 32
===================================================
python Detector/examples/test-scaling-subproc.py -1
python Detector/examples/test-scaling-subproc.py -1 10
python Detector/examples/test-scaling-subproc.py -1 64
python Detector/examples/test-scaling-subproc.py -1 127

python Detector/examples/test-scaling-subproc.py -2  > v8_1
python Detector/examples/test-scaling-subproc.py -8  > v16_1
python Detector/examples/test-scaling-subproc.py -13  > v32_1
python Detector/examples/test-scaling-subproc.py -17  > v64
python Detector/examples/test-scaling-subproc.py -18  > v120


ana-4.0.59-py3 [dubrovin@sdfmilan216:~/LCLS/con-py3]$ python Detector/examples/test-scaling-subproc.py -99
sys.argv: ['Detector/examples/test-scaling-subproc.py', '-99']
selector for mode: -99



sort_records_in_file: figs/fig-subpr32-v1-sdfmilan216-summary.txt
records:
means: shape:(4,) size:4 dtype:float64
[0.171 0.17  0.174 0.174]
mean time (sec): 0.1723

hostname:sdfmilan216 cpu:005 cmt:v1 proc time (sec) mean: 0.171 +/- 0.040 rms: 0.051 +/- 0.028
hostname:sdfmilan216 cpu:010 cmt:v1 proc time (sec) mean: 0.170 +/- 0.039 rms: 0.051 +/- 0.028
hostname:sdfmilan216 cpu:064 cmt:v1 proc time (sec) mean: 0.174 +/- 0.047 rms: 0.052 +/- 0.033
hostname:sdfmilan216 cpu:127 cmt:v1 proc time (sec) mean: 0.174 +/- 0.047 rms: 0.052 +/- 0.033
mean time (sec): 0.1723



sort_records_in_file: figs/fig-subpr32-v08-1-sdfmilan216-summary.txt
records:
means: shape:(8,) size:8 dtype:float64
[0.187 0.186 0.188 0.187 0.189 0.191 0.19  0.191]
mean time (sec): 0.1886

hostname:sdfmilan216 cpu:000 cmt:v08-1 proc time (sec) mean: 0.187 +/- 0.039 rms: 0.057 +/- 0.028
hostname:sdfmilan216 cpu:001 cmt:v08-1 proc time (sec) mean: 0.186 +/- 0.037 rms: 0.056 +/- 0.026
hostname:sdfmilan216 cpu:002 cmt:v08-1 proc time (sec) mean: 0.188 +/- 0.039 rms: 0.057 +/- 0.028
hostname:sdfmilan216 cpu:003 cmt:v08-1 proc time (sec) mean: 0.187 +/- 0.039 rms: 0.056 +/- 0.027
hostname:sdfmilan216 cpu:004 cmt:v08-1 proc time (sec) mean: 0.189 +/- 0.039 rms: 0.057 +/- 0.027
hostname:sdfmilan216 cpu:005 cmt:v08-1 proc time (sec) mean: 0.191 +/- 0.044 rms: 0.058 +/- 0.031
hostname:sdfmilan216 cpu:006 cmt:v08-1 proc time (sec) mean: 0.190 +/- 0.040 rms: 0.057 +/- 0.028
hostname:sdfmilan216 cpu:007 cmt:v08-1 proc time (sec) mean: 0.191 +/- 0.043 rms: 0.057 +/- 0.030
mean time (sec): 0.1886



sort_records_in_file: figs/fig-subpr32-v16-1-sdfmilan216-summary.txt
records:
means: shape:(16,) size:16 dtype:float64
[0.226 0.222 0.224 0.223 0.225 0.223 0.224 0.229 0.222 0.218 0.219 0.225
 0.225 0.22  0.222 0.225]
mean time (sec): 0.2233

hostname:sdfmilan216 cpu:000 cmt:v16-1 proc time (sec) mean: 0.226 +/- 0.034 rms: 0.072 +/- 0.024
hostname:sdfmilan216 cpu:001 cmt:v16-1 proc time (sec) mean: 0.222 +/- 0.032 rms: 0.072 +/- 0.023
hostname:sdfmilan216 cpu:002 cmt:v16-1 proc time (sec) mean: 0.224 +/- 0.032 rms: 0.072 +/- 0.022
hostname:sdfmilan216 cpu:003 cmt:v16-1 proc time (sec) mean: 0.223 +/- 0.032 rms: 0.071 +/- 0.023
hostname:sdfmilan216 cpu:004 cmt:v16-1 proc time (sec) mean: 0.225 +/- 0.032 rms: 0.072 +/- 0.023
hostname:sdfmilan216 cpu:005 cmt:v16-1 proc time (sec) mean: 0.223 +/- 0.033 rms: 0.070 +/- 0.024
hostname:sdfmilan216 cpu:006 cmt:v16-1 proc time (sec) mean: 0.224 +/- 0.034 rms: 0.071 +/- 0.024
hostname:sdfmilan216 cpu:007 cmt:v16-1 proc time (sec) mean: 0.229 +/- 0.033 rms: 0.073 +/- 0.023
hostname:sdfmilan216 cpu:008 cmt:v16-1 proc time (sec) mean: 0.222 +/- 0.033 rms: 0.071 +/- 0.023
hostname:sdfmilan216 cpu:009 cmt:v16-1 proc time (sec) mean: 0.218 +/- 0.032 rms: 0.070 +/- 0.023
hostname:sdfmilan216 cpu:010 cmt:v16-1 proc time (sec) mean: 0.219 +/- 0.035 rms: 0.069 +/- 0.024
hostname:sdfmilan216 cpu:011 cmt:v16-1 proc time (sec) mean: 0.225 +/- 0.032 rms: 0.072 +/- 0.023
hostname:sdfmilan216 cpu:012 cmt:v16-1 proc time (sec) mean: 0.225 +/- 0.033 rms: 0.071 +/- 0.023
hostname:sdfmilan216 cpu:013 cmt:v16-1 proc time (sec) mean: 0.220 +/- 0.035 rms: 0.069 +/- 0.025
hostname:sdfmilan216 cpu:014 cmt:v16-1 proc time (sec) mean: 0.222 +/- 0.033 rms: 0.070 +/- 0.023
hostname:sdfmilan216 cpu:015 cmt:v16-1 proc time (sec) mean: 0.225 +/- 0.032 rms: 0.071 +/- 0.023
mean time (sec): 0.2233



sort_records_in_file: figs/fig-subpr32-v32-1-sdfmilan216-summary.txt
records:
means: shape:(32,) size:32 dtype:float64
[0.226 0.228 0.225 0.226 0.227 0.229 0.227 0.231 0.226 0.231 0.23  0.23
 0.233 0.234 0.231 0.229 0.226 0.232 0.227 0.23  0.229 0.228 0.231 0.229
 0.229 0.23  0.229 0.232 0.233 0.231 0.231 0.232]
mean time (sec): 0.2294

hostname:sdfmilan216 cpu:032 cmt:v32-1 proc time (sec) mean: 0.226 +/- 0.034 rms: 0.072 +/- 0.024
hostname:sdfmilan216 cpu:033 cmt:v32-1 proc time (sec) mean: 0.228 +/- 0.032 rms: 0.072 +/- 0.023
hostname:sdfmilan216 cpu:034 cmt:v32-1 proc time (sec) mean: 0.225 +/- 0.033 rms: 0.072 +/- 0.024
hostname:sdfmilan216 cpu:035 cmt:v32-1 proc time (sec) mean: 0.226 +/- 0.034 rms: 0.071 +/- 0.024
hostname:sdfmilan216 cpu:036 cmt:v32-1 proc time (sec) mean: 0.227 +/- 0.033 rms: 0.073 +/- 0.023
hostname:sdfmilan216 cpu:037 cmt:v32-1 proc time (sec) mean: 0.229 +/- 0.034 rms: 0.072 +/- 0.024
hostname:sdfmilan216 cpu:038 cmt:v32-1 proc time (sec) mean: 0.227 +/- 0.033 rms: 0.072 +/- 0.023
hostname:sdfmilan216 cpu:039 cmt:v32-1 proc time (sec) mean: 0.231 +/- 0.034 rms: 0.073 +/- 0.024
hostname:sdfmilan216 cpu:040 cmt:v32-1 proc time (sec) mean: 0.226 +/- 0.033 rms: 0.071 +/- 0.023
hostname:sdfmilan216 cpu:041 cmt:v32-1 proc time (sec) mean: 0.231 +/- 0.034 rms: 0.072 +/- 0.024
hostname:sdfmilan216 cpu:042 cmt:v32-1 proc time (sec) mean: 0.230 +/- 0.035 rms: 0.072 +/- 0.025
hostname:sdfmilan216 cpu:043 cmt:v32-1 proc time (sec) mean: 0.230 +/- 0.034 rms: 0.074 +/- 0.024
hostname:sdfmilan216 cpu:044 cmt:v32-1 proc time (sec) mean: 0.233 +/- 0.033 rms: 0.074 +/- 0.023
hostname:sdfmilan216 cpu:045 cmt:v32-1 proc time (sec) mean: 0.234 +/- 0.033 rms: 0.075 +/- 0.023
hostname:sdfmilan216 cpu:046 cmt:v32-1 proc time (sec) mean: 0.231 +/- 0.033 rms: 0.073 +/- 0.024
hostname:sdfmilan216 cpu:047 cmt:v32-1 proc time (sec) mean: 0.229 +/- 0.032 rms: 0.073 +/- 0.023
hostname:sdfmilan216 cpu:048 cmt:v32-1 proc time (sec) mean: 0.226 +/- 0.033 rms: 0.071 +/- 0.023
hostname:sdfmilan216 cpu:049 cmt:v32-1 proc time (sec) mean: 0.232 +/- 0.033 rms: 0.074 +/- 0.023
hostname:sdfmilan216 cpu:050 cmt:v32-1 proc time (sec) mean: 0.227 +/- 0.035 rms: 0.072 +/- 0.025
hostname:sdfmilan216 cpu:051 cmt:v32-1 proc time (sec) mean: 0.230 +/- 0.033 rms: 0.073 +/- 0.023
hostname:sdfmilan216 cpu:052 cmt:v32-1 proc time (sec) mean: 0.229 +/- 0.035 rms: 0.074 +/- 0.024
hostname:sdfmilan216 cpu:053 cmt:v32-1 proc time (sec) mean: 0.228 +/- 0.033 rms: 0.073 +/- 0.023
hostname:sdfmilan216 cpu:054 cmt:v32-1 proc time (sec) mean: 0.231 +/- 0.034 rms: 0.072 +/- 0.024
hostname:sdfmilan216 cpu:055 cmt:v32-1 proc time (sec) mean: 0.229 +/- 0.031 rms: 0.073 +/- 0.022
hostname:sdfmilan216 cpu:056 cmt:v32-1 proc time (sec) mean: 0.229 +/- 0.036 rms: 0.073 +/- 0.025
hostname:sdfmilan216 cpu:057 cmt:v32-1 proc time (sec) mean: 0.230 +/- 0.033 rms: 0.073 +/- 0.023
hostname:sdfmilan216 cpu:058 cmt:v32-1 proc time (sec) mean: 0.229 +/- 0.035 rms: 0.073 +/- 0.025
hostname:sdfmilan216 cpu:059 cmt:v32-1 proc time (sec) mean: 0.232 +/- 0.033 rms: 0.074 +/- 0.024
hostname:sdfmilan216 cpu:060 cmt:v32-1 proc time (sec) mean: 0.233 +/- 0.034 rms: 0.074 +/- 0.024
hostname:sdfmilan216 cpu:061 cmt:v32-1 proc time (sec) mean: 0.231 +/- 0.032 rms: 0.074 +/- 0.023
hostname:sdfmilan216 cpu:062 cmt:v32-1 proc time (sec) mean: 0.231 +/- 0.034 rms: 0.073 +/- 0.024
hostname:sdfmilan216 cpu:063 cmt:v32-1 proc time (sec) mean: 0.232 +/- 0.033 rms: 0.075 +/- 0.023
mean time (sec): 0.2294



sort_records_in_file: figs/fig-subpr32-v64-sdfmilan216-summary.txt
records:
means: shape:(64,) size:64 dtype:float64
[0.478 0.468 0.46  0.496 0.477 0.488 0.472 0.492 0.5   0.486 0.487 0.499
 0.512 0.479 0.5   0.49  0.416 0.396 0.403 0.404 0.412 0.412 0.421 0.432
 0.434 0.399 0.411 0.404 0.425 0.419 0.422 0.436 0.236 0.247 0.236 0.241
 0.241 0.24  0.235 0.238 0.242 0.241 0.238 0.242 0.239 0.238 0.239 0.245
 0.237 0.232 0.234 0.232 0.237 0.233 0.234 0.236 0.237 0.245 0.242 0.245
 0.243 0.243 0.244 0.24 ]
mean time (sec): 0.3450

hostname:sdfmilan216 cpu:064 cmt:v64 proc time (sec) mean: 0.478 +/- 0.045 rms: 0.180 +/- 0.032
hostname:sdfmilan216 cpu:065 cmt:v64 proc time (sec) mean: 0.468 +/- 0.043 rms: 0.179 +/- 0.031
hostname:sdfmilan216 cpu:066 cmt:v64 proc time (sec) mean: 0.460 +/- 0.045 rms: 0.175 +/- 0.032
hostname:sdfmilan216 cpu:067 cmt:v64 proc time (sec) mean: 0.496 +/- 0.046 rms: 0.194 +/- 0.033
hostname:sdfmilan216 cpu:068 cmt:v64 proc time (sec) mean: 0.477 +/- 0.043 rms: 0.182 +/- 0.030
hostname:sdfmilan216 cpu:069 cmt:v64 proc time (sec) mean: 0.488 +/- 0.044 rms: 0.196 +/- 0.031
hostname:sdfmilan216 cpu:070 cmt:v64 proc time (sec) mean: 0.472 +/- 0.044 rms: 0.181 +/- 0.031
hostname:sdfmilan216 cpu:071 cmt:v64 proc time (sec) mean: 0.492 +/- 0.046 rms: 0.190 +/- 0.032
hostname:sdfmilan216 cpu:072 cmt:v64 proc time (sec) mean: 0.500 +/- 0.047 rms: 0.195 +/- 0.033
hostname:sdfmilan216 cpu:073 cmt:v64 proc time (sec) mean: 0.486 +/- 0.047 rms: 0.193 +/- 0.033
hostname:sdfmilan216 cpu:074 cmt:v64 proc time (sec) mean: 0.487 +/- 0.043 rms: 0.193 +/- 0.031
hostname:sdfmilan216 cpu:075 cmt:v64 proc time (sec) mean: 0.499 +/- 0.046 rms: 0.196 +/- 0.033
hostname:sdfmilan216 cpu:076 cmt:v64 proc time (sec) mean: 0.512 +/- 0.048 rms: 0.204 +/- 0.034
hostname:sdfmilan216 cpu:077 cmt:v64 proc time (sec) mean: 0.479 +/- 0.045 rms: 0.185 +/- 0.032
hostname:sdfmilan216 cpu:078 cmt:v64 proc time (sec) mean: 0.500 +/- 0.045 rms: 0.201 +/- 0.032
hostname:sdfmilan216 cpu:079 cmt:v64 proc time (sec) mean: 0.490 +/- 0.046 rms: 0.196 +/- 0.032
hostname:sdfmilan216 cpu:080 cmt:v64 proc time (sec) mean: 0.416 +/- 0.044 rms: 0.144 +/- 0.031
hostname:sdfmilan216 cpu:081 cmt:v64 proc time (sec) mean: 0.396 +/- 0.040 rms: 0.140 +/- 0.028
hostname:sdfmilan216 cpu:082 cmt:v64 proc time (sec) mean: 0.403 +/- 0.040 rms: 0.139 +/- 0.029
hostname:sdfmilan216 cpu:083 cmt:v64 proc time (sec) mean: 0.404 +/- 0.045 rms: 0.139 +/- 0.032
hostname:sdfmilan216 cpu:084 cmt:v64 proc time (sec) mean: 0.412 +/- 0.043 rms: 0.142 +/- 0.030
hostname:sdfmilan216 cpu:085 cmt:v64 proc time (sec) mean: 0.412 +/- 0.043 rms: 0.143 +/- 0.030
hostname:sdfmilan216 cpu:086 cmt:v64 proc time (sec) mean: 0.421 +/- 0.048 rms: 0.145 +/- 0.034
hostname:sdfmilan216 cpu:087 cmt:v64 proc time (sec) mean: 0.432 +/- 0.048 rms: 0.142 +/- 0.034
hostname:sdfmilan216 cpu:088 cmt:v64 proc time (sec) mean: 0.434 +/- 0.047 rms: 0.146 +/- 0.033
hostname:sdfmilan216 cpu:089 cmt:v64 proc time (sec) mean: 0.399 +/- 0.041 rms: 0.141 +/- 0.029
hostname:sdfmilan216 cpu:090 cmt:v64 proc time (sec) mean: 0.411 +/- 0.041 rms: 0.144 +/- 0.029
hostname:sdfmilan216 cpu:091 cmt:v64 proc time (sec) mean: 0.404 +/- 0.042 rms: 0.141 +/- 0.030
hostname:sdfmilan216 cpu:092 cmt:v64 proc time (sec) mean: 0.425 +/- 0.045 rms: 0.144 +/- 0.032
hostname:sdfmilan216 cpu:093 cmt:v64 proc time (sec) mean: 0.419 +/- 0.044 rms: 0.144 +/- 0.031
hostname:sdfmilan216 cpu:094 cmt:v64 proc time (sec) mean: 0.422 +/- 0.045 rms: 0.145 +/- 0.032
hostname:sdfmilan216 cpu:095 cmt:v64 proc time (sec) mean: 0.436 +/- 0.047 rms: 0.147 +/- 0.034
hostname:sdfmilan216 cpu:096 cmt:v64 proc time (sec) mean: 0.236 +/- 0.041 rms: 0.073 +/- 0.029
hostname:sdfmilan216 cpu:097 cmt:v64 proc time (sec) mean: 0.247 +/- 0.036 rms: 0.078 +/- 0.026
hostname:sdfmilan216 cpu:098 cmt:v64 proc time (sec) mean: 0.236 +/- 0.040 rms: 0.073 +/- 0.028
hostname:sdfmilan216 cpu:099 cmt:v64 proc time (sec) mean: 0.241 +/- 0.037 rms: 0.076 +/- 0.026
hostname:sdfmilan216 cpu:100 cmt:v64 proc time (sec) mean: 0.241 +/- 0.039 rms: 0.074 +/- 0.028
hostname:sdfmilan216 cpu:101 cmt:v64 proc time (sec) mean: 0.240 +/- 0.038 rms: 0.075 +/- 0.027
hostname:sdfmilan216 cpu:102 cmt:v64 proc time (sec) mean: 0.235 +/- 0.041 rms: 0.073 +/- 0.029
hostname:sdfmilan216 cpu:103 cmt:v64 proc time (sec) mean: 0.238 +/- 0.037 rms: 0.074 +/- 0.026
hostname:sdfmilan216 cpu:104 cmt:v64 proc time (sec) mean: 0.242 +/- 0.038 rms: 0.076 +/- 0.027
hostname:sdfmilan216 cpu:105 cmt:v64 proc time (sec) mean: 0.241 +/- 0.038 rms: 0.075 +/- 0.027
hostname:sdfmilan216 cpu:106 cmt:v64 proc time (sec) mean: 0.238 +/- 0.039 rms: 0.074 +/- 0.027
hostname:sdfmilan216 cpu:107 cmt:v64 proc time (sec) mean: 0.242 +/- 0.037 rms: 0.076 +/- 0.027
hostname:sdfmilan216 cpu:108 cmt:v64 proc time (sec) mean: 0.239 +/- 0.040 rms: 0.074 +/- 0.029
hostname:sdfmilan216 cpu:109 cmt:v64 proc time (sec) mean: 0.238 +/- 0.038 rms: 0.075 +/- 0.027
hostname:sdfmilan216 cpu:110 cmt:v64 proc time (sec) mean: 0.239 +/- 0.039 rms: 0.074 +/- 0.028
hostname:sdfmilan216 cpu:111 cmt:v64 proc time (sec) mean: 0.245 +/- 0.039 rms: 0.076 +/- 0.028
hostname:sdfmilan216 cpu:112 cmt:v64 proc time (sec) mean: 0.237 +/- 0.038 rms: 0.073 +/- 0.027
hostname:sdfmilan216 cpu:113 cmt:v64 proc time (sec) mean: 0.232 +/- 0.037 rms: 0.073 +/- 0.026
hostname:sdfmilan216 cpu:114 cmt:v64 proc time (sec) mean: 0.234 +/- 0.039 rms: 0.072 +/- 0.028
hostname:sdfmilan216 cpu:115 cmt:v64 proc time (sec) mean: 0.232 +/- 0.039 rms: 0.071 +/- 0.028
hostname:sdfmilan216 cpu:116 cmt:v64 proc time (sec) mean: 0.237 +/- 0.038 rms: 0.074 +/- 0.027
hostname:sdfmilan216 cpu:117 cmt:v64 proc time (sec) mean: 0.233 +/- 0.037 rms: 0.072 +/- 0.026
hostname:sdfmilan216 cpu:118 cmt:v64 proc time (sec) mean: 0.234 +/- 0.040 rms: 0.072 +/- 0.028
hostname:sdfmilan216 cpu:119 cmt:v64 proc time (sec) mean: 0.236 +/- 0.041 rms: 0.073 +/- 0.029
hostname:sdfmilan216 cpu:120 cmt:v64 proc time (sec) mean: 0.237 +/- 0.038 rms: 0.073 +/- 0.027
hostname:sdfmilan216 cpu:121 cmt:v64 proc time (sec) mean: 0.245 +/- 0.038 rms: 0.076 +/- 0.027
hostname:sdfmilan216 cpu:122 cmt:v64 proc time (sec) mean: 0.242 +/- 0.039 rms: 0.075 +/- 0.028
hostname:sdfmilan216 cpu:123 cmt:v64 proc time (sec) mean: 0.245 +/- 0.037 rms: 0.077 +/- 0.026
hostname:sdfmilan216 cpu:124 cmt:v64 proc time (sec) mean: 0.243 +/- 0.037 rms: 0.076 +/- 0.027
hostname:sdfmilan216 cpu:125 cmt:v64 proc time (sec) mean: 0.243 +/- 0.038 rms: 0.076 +/- 0.027
hostname:sdfmilan216 cpu:126 cmt:v64 proc time (sec) mean: 0.244 +/- 0.036 rms: 0.076 +/- 0.026
hostname:sdfmilan216 cpu:127 cmt:v64 proc time (sec) mean: 0.240 +/- 0.037 rms: 0.075 +/- 0.026
mean time (sec): 0.3450



sort_records_in_file: figs/fig-subpr32-v120-sdfmilan216-summary.txt
records:
means: shape:(120,) size:120 dtype:float64
[0.26  0.259 0.255 0.254 0.256 0.259 0.261 0.256 0.264 0.257 0.262 0.259
 0.261 0.259 0.26  0.263 0.242 0.238 0.24  0.243 0.236 0.244 0.241 0.241
 0.253 0.254 0.259 0.256 0.258 0.26  0.257 0.258 0.261 0.257 0.259 0.258
 0.261 0.259 0.256 0.259 0.258 0.258 0.26  0.264 0.255 0.254 0.258 0.261
 0.255 0.263 0.263 0.257 0.26  0.258 0.264 0.262 0.511 0.511 0.512 0.482
 0.519 0.5   0.498 0.505 0.465 0.429 0.434 0.48  0.469 0.463 0.458 0.476
 0.406 0.409 0.429 0.425 0.416 0.413 0.419 0.42  0.411 0.391 0.402 0.401
 0.42  0.397 0.395 0.406 0.245 0.245 0.241 0.239 0.239 0.246 0.242 0.237
 0.24  0.245 0.243 0.243...]
mean time (sec): 0.3029

hostname:sdfmilan216 cpu:000 cmt:v120 proc time (sec) mean: 0.260 +/- 0.048 rms: 0.083 +/- 0.034
hostname:sdfmilan216 cpu:001 cmt:v120 proc time (sec) mean: 0.259 +/- 0.043 rms: 0.080 +/- 0.031
hostname:sdfmilan216 cpu:002 cmt:v120 proc time (sec) mean: 0.255 +/- 0.050 rms: 0.078 +/- 0.035
hostname:sdfmilan216 cpu:003 cmt:v120 proc time (sec) mean: 0.254 +/- 0.051 rms: 0.078 +/- 0.036
hostname:sdfmilan216 cpu:004 cmt:v120 proc time (sec) mean: 0.256 +/- 0.046 rms: 0.079 +/- 0.033
hostname:sdfmilan216 cpu:005 cmt:v120 proc time (sec) mean: 0.259 +/- 0.047 rms: 0.081 +/- 0.033
hostname:sdfmilan216 cpu:006 cmt:v120 proc time (sec) mean: 0.261 +/- 0.045 rms: 0.081 +/- 0.032
hostname:sdfmilan216 cpu:007 cmt:v120 proc time (sec) mean: 0.256 +/- 0.046 rms: 0.079 +/- 0.032
hostname:sdfmilan216 cpu:008 cmt:v120 proc time (sec) mean: 0.264 +/- 0.042 rms: 0.082 +/- 0.030
hostname:sdfmilan216 cpu:009 cmt:v120 proc time (sec) mean: 0.257 +/- 0.047 rms: 0.079 +/- 0.034
hostname:sdfmilan216 cpu:010 cmt:v120 proc time (sec) mean: 0.262 +/- 0.044 rms: 0.081 +/- 0.031
hostname:sdfmilan216 cpu:011 cmt:v120 proc time (sec) mean: 0.259 +/- 0.044 rms: 0.080 +/- 0.031
hostname:sdfmilan216 cpu:012 cmt:v120 proc time (sec) mean: 0.261 +/- 0.045 rms: 0.081 +/- 0.032
hostname:sdfmilan216 cpu:013 cmt:v120 proc time (sec) mean: 0.259 +/- 0.046 rms: 0.080 +/- 0.033
hostname:sdfmilan216 cpu:014 cmt:v120 proc time (sec) mean: 0.260 +/- 0.044 rms: 0.080 +/- 0.031
hostname:sdfmilan216 cpu:015 cmt:v120 proc time (sec) mean: 0.263 +/- 0.044 rms: 0.082 +/- 0.031
hostname:sdfmilan216 cpu:024 cmt:v120 proc time (sec) mean: 0.242 +/- 0.055 rms: 0.074 +/- 0.039
hostname:sdfmilan216 cpu:025 cmt:v120 proc time (sec) mean: 0.238 +/- 0.046 rms: 0.072 +/- 0.032
hostname:sdfmilan216 cpu:026 cmt:v120 proc time (sec) mean: 0.240 +/- 0.048 rms: 0.073 +/- 0.034
hostname:sdfmilan216 cpu:027 cmt:v120 proc time (sec) mean: 0.243 +/- 0.051 rms: 0.074 +/- 0.036
hostname:sdfmilan216 cpu:028 cmt:v120 proc time (sec) mean: 0.236 +/- 0.046 rms: 0.072 +/- 0.033
hostname:sdfmilan216 cpu:029 cmt:v120 proc time (sec) mean: 0.244 +/- 0.058 rms: 0.074 +/- 0.041
hostname:sdfmilan216 cpu:030 cmt:v120 proc time (sec) mean: 0.241 +/- 0.050 rms: 0.073 +/- 0.035
hostname:sdfmilan216 cpu:031 cmt:v120 proc time (sec) mean: 0.241 +/- 0.049 rms: 0.078 +/- 0.035
hostname:sdfmilan216 cpu:032 cmt:v120 proc time (sec) mean: 0.253 +/- 0.052 rms: 0.077 +/- 0.036
hostname:sdfmilan216 cpu:033 cmt:v120 proc time (sec) mean: 0.254 +/- 0.050 rms: 0.078 +/- 0.035
hostname:sdfmilan216 cpu:034 cmt:v120 proc time (sec) mean: 0.259 +/- 0.046 rms: 0.079 +/- 0.032
hostname:sdfmilan216 cpu:035 cmt:v120 proc time (sec) mean: 0.256 +/- 0.048 rms: 0.079 +/- 0.034
hostname:sdfmilan216 cpu:036 cmt:v120 proc time (sec) mean: 0.258 +/- 0.047 rms: 0.079 +/- 0.033
hostname:sdfmilan216 cpu:037 cmt:v120 proc time (sec) mean: 0.260 +/- 0.047 rms: 0.081 +/- 0.033
hostname:sdfmilan216 cpu:038 cmt:v120 proc time (sec) mean: 0.257 +/- 0.046 rms: 0.080 +/- 0.032
hostname:sdfmilan216 cpu:039 cmt:v120 proc time (sec) mean: 0.258 +/- 0.046 rms: 0.079 +/- 0.033
hostname:sdfmilan216 cpu:040 cmt:v120 proc time (sec) mean: 0.261 +/- 0.044 rms: 0.081 +/- 0.031
hostname:sdfmilan216 cpu:041 cmt:v120 proc time (sec) mean: 0.257 +/- 0.046 rms: 0.079 +/- 0.033
hostname:sdfmilan216 cpu:042 cmt:v120 proc time (sec) mean: 0.259 +/- 0.046 rms: 0.080 +/- 0.032
hostname:sdfmilan216 cpu:043 cmt:v120 proc time (sec) mean: 0.258 +/- 0.044 rms: 0.080 +/- 0.031
hostname:sdfmilan216 cpu:044 cmt:v120 proc time (sec) mean: 0.261 +/- 0.045 rms: 0.080 +/- 0.032
hostname:sdfmilan216 cpu:045 cmt:v120 proc time (sec) mean: 0.259 +/- 0.047 rms: 0.079 +/- 0.033
hostname:sdfmilan216 cpu:046 cmt:v120 proc time (sec) mean: 0.256 +/- 0.046 rms: 0.079 +/- 0.032
hostname:sdfmilan216 cpu:047 cmt:v120 proc time (sec) mean: 0.259 +/- 0.046 rms: 0.080 +/- 0.032
hostname:sdfmilan216 cpu:048 cmt:v120 proc time (sec) mean: 0.258 +/- 0.048 rms: 0.080 +/- 0.034
hostname:sdfmilan216 cpu:049 cmt:v120 proc time (sec) mean: 0.258 +/- 0.043 rms: 0.080 +/- 0.031
hostname:sdfmilan216 cpu:050 cmt:v120 proc time (sec) mean: 0.260 +/- 0.045 rms: 0.081 +/- 0.032
hostname:sdfmilan216 cpu:051 cmt:v120 proc time (sec) mean: 0.264 +/- 0.045 rms: 0.088 +/- 0.032
hostname:sdfmilan216 cpu:052 cmt:v120 proc time (sec) mean: 0.255 +/- 0.050 rms: 0.078 +/- 0.035
hostname:sdfmilan216 cpu:053 cmt:v120 proc time (sec) mean: 0.254 +/- 0.050 rms: 0.078 +/- 0.035
hostname:sdfmilan216 cpu:054 cmt:v120 proc time (sec) mean: 0.258 +/- 0.045 rms: 0.080 +/- 0.032
hostname:sdfmilan216 cpu:055 cmt:v120 proc time (sec) mean: 0.261 +/- 0.048 rms: 0.080 +/- 0.034
hostname:sdfmilan216 cpu:056 cmt:v120 proc time (sec) mean: 0.255 +/- 0.051 rms: 0.079 +/- 0.036
hostname:sdfmilan216 cpu:057 cmt:v120 proc time (sec) mean: 0.263 +/- 0.045 rms: 0.081 +/- 0.032
hostname:sdfmilan216 cpu:058 cmt:v120 proc time (sec) mean: 0.263 +/- 0.046 rms: 0.088 +/- 0.032
hostname:sdfmilan216 cpu:059 cmt:v120 proc time (sec) mean: 0.257 +/- 0.049 rms: 0.080 +/- 0.035
hostname:sdfmilan216 cpu:060 cmt:v120 proc time (sec) mean: 0.260 +/- 0.049 rms: 0.080 +/- 0.034
hostname:sdfmilan216 cpu:061 cmt:v120 proc time (sec) mean: 0.258 +/- 0.047 rms: 0.079 +/- 0.033
hostname:sdfmilan216 cpu:062 cmt:v120 proc time (sec) mean: 0.264 +/- 0.047 rms: 0.082 +/- 0.034
hostname:sdfmilan216 cpu:063 cmt:v120 proc time (sec) mean: 0.262 +/- 0.041 rms: 0.081 +/- 0.029
hostname:sdfmilan216 cpu:064 cmt:v120 proc time (sec) mean: 0.511 +/- 0.049 rms: 0.193 +/- 0.035
hostname:sdfmilan216 cpu:065 cmt:v120 proc time (sec) mean: 0.511 +/- 0.049 rms: 0.194 +/- 0.035
hostname:sdfmilan216 cpu:066 cmt:v120 proc time (sec) mean: 0.512 +/- 0.050 rms: 0.198 +/- 0.035
hostname:sdfmilan216 cpu:067 cmt:v120 proc time (sec) mean: 0.482 +/- 0.044 rms: 0.181 +/- 0.031
hostname:sdfmilan216 cpu:068 cmt:v120 proc time (sec) mean: 0.519 +/- 0.052 rms: 0.192 +/- 0.036
hostname:sdfmilan216 cpu:069 cmt:v120 proc time (sec) mean: 0.500 +/- 0.046 rms: 0.187 +/- 0.033
hostname:sdfmilan216 cpu:070 cmt:v120 proc time (sec) mean: 0.498 +/- 0.050 rms: 0.186 +/- 0.035
hostname:sdfmilan216 cpu:071 cmt:v120 proc time (sec) mean: 0.505 +/- 0.051 rms: 0.190 +/- 0.036
hostname:sdfmilan216 cpu:072 cmt:v120 proc time (sec) mean: 0.465 +/- 0.045 rms: 0.160 +/- 0.032
hostname:sdfmilan216 cpu:073 cmt:v120 proc time (sec) mean: 0.429 +/- 0.043 rms: 0.168 +/- 0.030
hostname:sdfmilan216 cpu:074 cmt:v120 proc time (sec) mean: 0.434 +/- 0.043 rms: 0.166 +/- 0.031
hostname:sdfmilan216 cpu:075 cmt:v120 proc time (sec) mean: 0.480 +/- 0.045 rms: 0.169 +/- 0.032
hostname:sdfmilan216 cpu:076 cmt:v120 proc time (sec) mean: 0.469 +/- 0.046 rms: 0.163 +/- 0.032
hostname:sdfmilan216 cpu:077 cmt:v120 proc time (sec) mean: 0.463 +/- 0.044 rms: 0.160 +/- 0.031
hostname:sdfmilan216 cpu:078 cmt:v120 proc time (sec) mean: 0.458 +/- 0.044 rms: 0.158 +/- 0.031
hostname:sdfmilan216 cpu:079 cmt:v120 proc time (sec) mean: 0.476 +/- 0.047 rms: 0.165 +/- 0.033
hostname:sdfmilan216 cpu:080 cmt:v120 proc time (sec) mean: 0.406 +/- 0.041 rms: 0.140 +/- 0.029
hostname:sdfmilan216 cpu:081 cmt:v120 proc time (sec) mean: 0.409 +/- 0.043 rms: 0.137 +/- 0.030
hostname:sdfmilan216 cpu:082 cmt:v120 proc time (sec) mean: 0.429 +/- 0.045 rms: 0.143 +/- 0.032
hostname:sdfmilan216 cpu:083 cmt:v120 proc time (sec) mean: 0.425 +/- 0.045 rms: 0.143 +/- 0.032
hostname:sdfmilan216 cpu:084 cmt:v120 proc time (sec) mean: 0.416 +/- 0.042 rms: 0.144 +/- 0.030
hostname:sdfmilan216 cpu:085 cmt:v120 proc time (sec) mean: 0.413 +/- 0.043 rms: 0.142 +/- 0.030
hostname:sdfmilan216 cpu:086 cmt:v120 proc time (sec) mean: 0.419 +/- 0.041 rms: 0.143 +/- 0.029
hostname:sdfmilan216 cpu:087 cmt:v120 proc time (sec) mean: 0.420 +/- 0.041 rms: 0.147 +/- 0.029
hostname:sdfmilan216 cpu:088 cmt:v120 proc time (sec) mean: 0.411 +/- 0.045 rms: 0.137 +/- 0.031
hostname:sdfmilan216 cpu:089 cmt:v120 proc time (sec) mean: 0.391 +/- 0.039 rms: 0.137 +/- 0.028
hostname:sdfmilan216 cpu:090 cmt:v120 proc time (sec) mean: 0.402 +/- 0.041 rms: 0.138 +/- 0.029
hostname:sdfmilan216 cpu:091 cmt:v120 proc time (sec) mean: 0.401 +/- 0.041 rms: 0.142 +/- 0.029
hostname:sdfmilan216 cpu:092 cmt:v120 proc time (sec) mean: 0.420 +/- 0.045 rms: 0.142 +/- 0.032
hostname:sdfmilan216 cpu:093 cmt:v120 proc time (sec) mean: 0.397 +/- 0.040 rms: 0.135 +/- 0.028
hostname:sdfmilan216 cpu:094 cmt:v120 proc time (sec) mean: 0.395 +/- 0.038 rms: 0.137 +/- 0.027
hostname:sdfmilan216 cpu:095 cmt:v120 proc time (sec) mean: 0.406 +/- 0.040 rms: 0.141 +/- 0.028
hostname:sdfmilan216 cpu:096 cmt:v120 proc time (sec) mean: 0.245 +/- 0.040 rms: 0.076 +/- 0.029
hostname:sdfmilan216 cpu:097 cmt:v120 proc time (sec) mean: 0.245 +/- 0.041 rms: 0.076 +/- 0.029
hostname:sdfmilan216 cpu:098 cmt:v120 proc time (sec) mean: 0.241 +/- 0.041 rms: 0.074 +/- 0.029
hostname:sdfmilan216 cpu:099 cmt:v120 proc time (sec) mean: 0.239 +/- 0.042 rms: 0.073 +/- 0.030
hostname:sdfmilan216 cpu:100 cmt:v120 proc time (sec) mean: 0.239 +/- 0.044 rms: 0.074 +/- 0.031
hostname:sdfmilan216 cpu:101 cmt:v120 proc time (sec) mean: 0.246 +/- 0.042 rms: 0.077 +/- 0.030
hostname:sdfmilan216 cpu:102 cmt:v120 proc time (sec) mean: 0.242 +/- 0.040 rms: 0.075 +/- 0.028
hostname:sdfmilan216 cpu:103 cmt:v120 proc time (sec) mean: 0.237 +/- 0.042 rms: 0.073 +/- 0.030
hostname:sdfmilan216 cpu:104 cmt:v120 proc time (sec) mean: 0.240 +/- 0.044 rms: 0.074 +/- 0.031
hostname:sdfmilan216 cpu:105 cmt:v120 proc time (sec) mean: 0.245 +/- 0.040 rms: 0.076 +/- 0.028
hostname:sdfmilan216 cpu:106 cmt:v120 proc time (sec) mean: 0.243 +/- 0.041 rms: 0.075 +/- 0.029
hostname:sdfmilan216 cpu:107 cmt:v120 proc time (sec) mean: 0.243 +/- 0.040 rms: 0.076 +/- 0.029
hostname:sdfmilan216 cpu:108 cmt:v120 proc time (sec) mean: 0.240 +/- 0.043 rms: 0.074 +/- 0.031
hostname:sdfmilan216 cpu:109 cmt:v120 proc time (sec) mean: 0.238 +/- 0.043 rms: 0.073 +/- 0.030
hostname:sdfmilan216 cpu:110 cmt:v120 proc time (sec) mean: 0.243 +/- 0.041 rms: 0.075 +/- 0.029
hostname:sdfmilan216 cpu:111 cmt:v120 proc time (sec) mean: 0.244 +/- 0.039 rms: 0.076 +/- 0.027
hostname:sdfmilan216 cpu:112 cmt:v120 proc time (sec) mean: 0.237 +/- 0.046 rms: 0.073 +/- 0.033
hostname:sdfmilan216 cpu:113 cmt:v120 proc time (sec) mean: 0.242 +/- 0.042 rms: 0.074 +/- 0.029
hostname:sdfmilan216 cpu:114 cmt:v120 proc time (sec) mean: 0.241 +/- 0.041 rms: 0.074 +/- 0.029
hostname:sdfmilan216 cpu:115 cmt:v120 proc time (sec) mean: 0.244 +/- 0.042 rms: 0.075 +/- 0.030
hostname:sdfmilan216 cpu:116 cmt:v120 proc time (sec) mean: 0.240 +/- 0.043 rms: 0.074 +/- 0.030
hostname:sdfmilan216 cpu:117 cmt:v120 proc time (sec) mean: 0.244 +/- 0.044 rms: 0.076 +/- 0.031
hostname:sdfmilan216 cpu:118 cmt:v120 proc time (sec) mean: 0.240 +/- 0.042 rms: 0.074 +/- 0.030
hostname:sdfmilan216 cpu:119 cmt:v120 proc time (sec) mean: 0.241 +/- 0.042 rms: 0.074 +/- 0.030
hostname:sdfmilan216 cpu:120 cmt:v120 proc time (sec) mean: 0.238 +/- 0.043 rms: 0.073 +/- 0.030
hostname:sdfmilan216 cpu:121 cmt:v120 proc time (sec) mean: 0.239 +/- 0.045 rms: 0.073 +/- 0.032
hostname:sdfmilan216 cpu:122 cmt:v120 proc time (sec) mean: 0.238 +/- 0.045 rms: 0.073 +/- 0.032
hostname:sdfmilan216 cpu:123 cmt:v120 proc time (sec) mean: 0.243 +/- 0.041 rms: 0.075 +/- 0.029
hostname:sdfmilan216 cpu:124 cmt:v120 proc time (sec) mean: 0.243 +/- 0.046 rms: 0.075 +/- 0.033
hostname:sdfmilan216 cpu:125 cmt:v120 proc time (sec) mean: 0.244 +/- 0.041 rms: 0.075 +/- 0.029
hostname:sdfmilan216 cpu:126 cmt:v120 proc time (sec) mean: 0.241 +/- 0.043 rms: 0.074 +/- 0.030
hostname:sdfmilan216 cpu:127 cmt:v120 proc time (sec) mean: 0.243 +/- 0.044 rms: 0.074 +/- 0.031
mean time (sec): 0.3029
ana-4.0.59-py3 [dubrovin@sdfmilan216:~/LCLS/con-py3]$
Per-CPU time consumption test for float32, sh2d=(512,1024)
float32, single panel sh2d=(8*512,1024) > (512,1024), but nloops 100 > 800
==========================================================================
python Detector/examples/test-scaling-subproc.py -1
python Detector/examples/test-scaling-subproc.py -1 10
python Detector/examples/test-scaling-subproc.py -1 64
python Detector/examples/test-scaling-subproc.py -1 127

python Detector/examples/test-scaling-subproc.py -2  > v8_1
python Detector/examples/test-scaling-subproc.py -8  > v16_1
python Detector/examples/test-scaling-subproc.py -13  > v32_1
python Detector/examples/test-scaling-subproc.py -17  > v64
python Detector/examples/test-scaling-subproc.py -18  > v120


ana-4.0.59-py3 [dubrovin@sdfiana001:~/LCLS/con-py3]$ python Detector/examples/test-scaling-subproc.py  -99
sys.argv: ['Detector/examples/test-scaling-subproc.py', '-99']
selector for mode: -99



sort_records_in_file: figs/fig-subpr32-512k-v1-sdfmilan216-summary.txt
records:
means: shape:(4,) size:4 dtype:float64
[0.02   0.021  0.0212 0.021 ]
mean time (sec): 0.0208

hostname:sdfmilan216 cpu:005 cmt:v1 proc time (sec) mean: 0.0200 +/- 0.0040 rms: 0.0060 +/- 0.0028
hostname:sdfmilan216 cpu:010 cmt:v1 proc time (sec) mean: 0.0210 +/- 0.0057 rms: 0.0063 +/- 0.0040
hostname:sdfmilan216 cpu:064 cmt:v1 proc time (sec) mean: 0.0212 +/- 0.0057 rms: 0.0064 +/- 0.0040
hostname:sdfmilan216 cpu:127 cmt:v1 proc time (sec) mean: 0.0210 +/- 0.0057 rms: 0.0063 +/- 0.0040
mean time (sec): 0.0208


sort_records_in_file: figs/fig-subpr32-512k-v08-1-sdfmilan216-summary.txt
records:
means: shape:(8,) size:8 dtype:float64
[0.0217 0.0214 0.0213 0.0212 0.0214 0.0217 0.0212 0.0215]
mean time (sec): 0.0214

hostname:sdfmilan216 cpu:000 cmt:v08-1 proc time (sec) mean: 0.0217 +/- 0.0044 rms: 0.0066 +/- 0.0031
hostname:sdfmilan216 cpu:001 cmt:v08-1 proc time (sec) mean: 0.0214 +/- 0.0048 rms: 0.0065 +/- 0.0034
hostname:sdfmilan216 cpu:002 cmt:v08-1 proc time (sec) mean: 0.0213 +/- 0.0050 rms: 0.0064 +/- 0.0035
hostname:sdfmilan216 cpu:003 cmt:v08-1 proc time (sec) mean: 0.0212 +/- 0.0054 rms: 0.0064 +/- 0.0038
hostname:sdfmilan216 cpu:004 cmt:v08-1 proc time (sec) mean: 0.0214 +/- 0.0049 rms: 0.0064 +/- 0.0035
hostname:sdfmilan216 cpu:005 cmt:v08-1 proc time (sec) mean: 0.0217 +/- 0.0044 rms: 0.0066 +/- 0.0031
hostname:sdfmilan216 cpu:006 cmt:v08-1 proc time (sec) mean: 0.0212 +/- 0.0053 rms: 0.0064 +/- 0.0038
hostname:sdfmilan216 cpu:007 cmt:v08-1 proc time (sec) mean: 0.0215 +/- 0.0046 rms: 0.0065 +/- 0.0033
mean time (sec): 0.0214



sort_records_in_file: figs/fig-subpr32-512k-v16-1-sdfmilan216-summary.txt
records:
means: shape:(16,) size:16 dtype:float64
[0.0218 0.0219 0.0219 0.0222 0.0219 0.0218 0.022  0.0218 0.0216 0.0216
 0.0217 0.0219 0.0218 0.0215 0.0219 0.022 ]
mean time (sec): 0.0218

hostname:sdfmilan216 cpu:000 cmt:v16-1 proc time (sec) mean: 0.0218 +/- 0.0043 rms: 0.0066 +/- 0.0030
hostname:sdfmilan216 cpu:001 cmt:v16-1 proc time (sec) mean: 0.0219 +/- 0.0042 rms: 0.0067 +/- 0.0030
hostname:sdfmilan216 cpu:002 cmt:v16-1 proc time (sec) mean: 0.0219 +/- 0.0043 rms: 0.0067 +/- 0.0030
hostname:sdfmilan216 cpu:003 cmt:v16-1 proc time (sec) mean: 0.0222 +/- 0.0042 rms: 0.0068 +/- 0.0030
hostname:sdfmilan216 cpu:004 cmt:v16-1 proc time (sec) mean: 0.0219 +/- 0.0042 rms: 0.0067 +/- 0.0030
hostname:sdfmilan216 cpu:005 cmt:v16-1 proc time (sec) mean: 0.0218 +/- 0.0043 rms: 0.0066 +/- 0.0030
hostname:sdfmilan216 cpu:006 cmt:v16-1 proc time (sec) mean: 0.0220 +/- 0.0042 rms: 0.0067 +/- 0.0030
hostname:sdfmilan216 cpu:007 cmt:v16-1 proc time (sec) mean: 0.0218 +/- 0.0043 rms: 0.0066 +/- 0.0030
hostname:sdfmilan216 cpu:008 cmt:v16-1 proc time (sec) mean: 0.0216 +/- 0.0047 rms: 0.0066 +/- 0.0033
hostname:sdfmilan216 cpu:009 cmt:v16-1 proc time (sec) mean: 0.0216 +/- 0.0045 rms: 0.0066 +/- 0.0032
hostname:sdfmilan216 cpu:010 cmt:v16-1 proc time (sec) mean: 0.0217 +/- 0.0045 rms: 0.0066 +/- 0.0032
hostname:sdfmilan216 cpu:011 cmt:v16-1 proc time (sec) mean: 0.0219 +/- 0.0043 rms: 0.0067 +/- 0.0030
hostname:sdfmilan216 cpu:012 cmt:v16-1 proc time (sec) mean: 0.0218 +/- 0.0045 rms: 0.0067 +/- 0.0032
hostname:sdfmilan216 cpu:013 cmt:v16-1 proc time (sec) mean: 0.0215 +/- 0.0048 rms: 0.0065 +/- 0.0034
hostname:sdfmilan216 cpu:014 cmt:v16-1 proc time (sec) mean: 0.0219 +/- 0.0043 rms: 0.0066 +/- 0.0030
hostname:sdfmilan216 cpu:015 cmt:v16-1 proc time (sec) mean: 0.0220 +/- 0.0042 rms: 0.0067 +/- 0.0030
mean time (sec): 0.0218



sort_records_in_file: figs/fig-subpr32-512k-v32-1-sdfmilan216-summary.txt
records:
means: shape:(32,) size:32 dtype:float64
[0.0229 0.0228 0.0227 0.0227 0.023  0.023  0.0225 0.0229 0.0227 0.0228
 0.0227 0.0226 0.0228 0.0228 0.0229 0.023  0.023  0.0227 0.023  0.0228
 0.0228 0.0231 0.0231 0.0229 0.0227 0.0227 0.0228 0.0228 0.0229 0.0226
 0.023  0.0229]
mean time (sec): 0.0228

hostname:sdfmilan216 cpu:032 cmt:v32-1 proc time (sec) mean: 0.0229 +/- 0.0051 rms: 0.0070 +/- 0.0036
hostname:sdfmilan216 cpu:033 cmt:v32-1 proc time (sec) mean: 0.0228 +/- 0.0056 rms: 0.0069 +/- 0.0039
hostname:sdfmilan216 cpu:034 cmt:v32-1 proc time (sec) mean: 0.0227 +/- 0.0049 rms: 0.0069 +/- 0.0034
hostname:sdfmilan216 cpu:035 cmt:v32-1 proc time (sec) mean: 0.0227 +/- 0.0047 rms: 0.0069 +/- 0.0033
hostname:sdfmilan216 cpu:036 cmt:v32-1 proc time (sec) mean: 0.0230 +/- 0.0054 rms: 0.0070 +/- 0.0038
hostname:sdfmilan216 cpu:037 cmt:v32-1 proc time (sec) mean: 0.0230 +/- 0.0058 rms: 0.0070 +/- 0.0041
hostname:sdfmilan216 cpu:038 cmt:v32-1 proc time (sec) mean: 0.0225 +/- 0.0048 rms: 0.0068 +/- 0.0034
hostname:sdfmilan216 cpu:039 cmt:v32-1 proc time (sec) mean: 0.0229 +/- 0.0058 rms: 0.0069 +/- 0.0041
hostname:sdfmilan216 cpu:040 cmt:v32-1 proc time (sec) mean: 0.0227 +/- 0.0053 rms: 0.0069 +/- 0.0037
hostname:sdfmilan216 cpu:041 cmt:v32-1 proc time (sec) mean: 0.0228 +/- 0.0055 rms: 0.0069 +/- 0.0039
hostname:sdfmilan216 cpu:042 cmt:v32-1 proc time (sec) mean: 0.0227 +/- 0.0053 rms: 0.0069 +/- 0.0038
hostname:sdfmilan216 cpu:043 cmt:v32-1 proc time (sec) mean: 0.0226 +/- 0.0052 rms: 0.0069 +/- 0.0037
hostname:sdfmilan216 cpu:044 cmt:v32-1 proc time (sec) mean: 0.0228 +/- 0.0053 rms: 0.0069 +/- 0.0038
hostname:sdfmilan216 cpu:045 cmt:v32-1 proc time (sec) mean: 0.0228 +/- 0.0050 rms: 0.0069 +/- 0.0035
hostname:sdfmilan216 cpu:046 cmt:v32-1 proc time (sec) mean: 0.0229 +/- 0.0054 rms: 0.0069 +/- 0.0038
hostname:sdfmilan216 cpu:047 cmt:v32-1 proc time (sec) mean: 0.0230 +/- 0.0056 rms: 0.0070 +/- 0.0040
hostname:sdfmilan216 cpu:048 cmt:v32-1 proc time (sec) mean: 0.0230 +/- 0.0052 rms: 0.0070 +/- 0.0037
hostname:sdfmilan216 cpu:049 cmt:v32-1 proc time (sec) mean: 0.0227 +/- 0.0054 rms: 0.0069 +/- 0.0038
hostname:sdfmilan216 cpu:050 cmt:v32-1 proc time (sec) mean: 0.0230 +/- 0.0047 rms: 0.0070 +/- 0.0033
hostname:sdfmilan216 cpu:051 cmt:v32-1 proc time (sec) mean: 0.0228 +/- 0.0055 rms: 0.0069 +/- 0.0039
hostname:sdfmilan216 cpu:052 cmt:v32-1 proc time (sec) mean: 0.0228 +/- 0.0047 rms: 0.0069 +/- 0.0033
hostname:sdfmilan216 cpu:053 cmt:v32-1 proc time (sec) mean: 0.0231 +/- 0.0053 rms: 0.0070 +/- 0.0038
hostname:sdfmilan216 cpu:054 cmt:v32-1 proc time (sec) mean: 0.0231 +/- 0.0052 rms: 0.0070 +/- 0.0037
hostname:sdfmilan216 cpu:055 cmt:v32-1 proc time (sec) mean: 0.0229 +/- 0.0051 rms: 0.0069 +/- 0.0036
hostname:sdfmilan216 cpu:056 cmt:v32-1 proc time (sec) mean: 0.0227 +/- 0.0052 rms: 0.0069 +/- 0.0036
hostname:sdfmilan216 cpu:057 cmt:v32-1 proc time (sec) mean: 0.0227 +/- 0.0050 rms: 0.0069 +/- 0.0036
hostname:sdfmilan216 cpu:058 cmt:v32-1 proc time (sec) mean: 0.0228 +/- 0.0056 rms: 0.0069 +/- 0.0039
hostname:sdfmilan216 cpu:059 cmt:v32-1 proc time (sec) mean: 0.0228 +/- 0.0053 rms: 0.0069 +/- 0.0037
hostname:sdfmilan216 cpu:060 cmt:v32-1 proc time (sec) mean: 0.0229 +/- 0.0050 rms: 0.0069 +/- 0.0035
hostname:sdfmilan216 cpu:061 cmt:v32-1 proc time (sec) mean: 0.0226 +/- 0.0053 rms: 0.0068 +/- 0.0037
hostname:sdfmilan216 cpu:062 cmt:v32-1 proc time (sec) mean: 0.0230 +/- 0.0054 rms: 0.0070 +/- 0.0038
hostname:sdfmilan216 cpu:063 cmt:v32-1 proc time (sec) mean: 0.0229 +/- 0.0053 rms: 0.0069 +/- 0.0037
mean time (sec): 0.0228



sort_records_in_file: figs/fig-subpr32-512k-v64-sdfmilan216-summary.txt
records:
means: shape:(64,) size:64 dtype:float64
[0.0287 0.0289 0.0288 0.0288 0.0303 0.0302 0.0308 0.0304 0.031  0.0299
 0.0301 0.0286 0.0305 0.0303 0.0284 0.0307 0.0291 0.0292 0.0287 0.0289
 0.0292 0.0291 0.0292 0.0294 0.0298 0.0289 0.0299 0.0288 0.0301 0.0292
 0.0289 0.0297 0.0263 0.0259 0.0262 0.0263 0.0262 0.0259 0.0263 0.026
 0.0262 0.0262 0.0263 0.0262 0.0262 0.0263 0.0258 0.0263 0.0262 0.0261
 0.0261 0.0263 0.0263 0.0263 0.0264 0.0262 0.0257 0.0261 0.0262 0.0263
 0.0263 0.0262 0.0261 0.0259]
mean time (sec): 0.0278

hostname:sdfmilan216 cpu:064 cmt:v64 proc time (sec) mean: 0.0287 +/- 0.0040 rms: 0.0092 +/- 0.0028
hostname:sdfmilan216 cpu:065 cmt:v64 proc time (sec) mean: 0.0289 +/- 0.0040 rms: 0.0094 +/- 0.0028
hostname:sdfmilan216 cpu:066 cmt:v64 proc time (sec) mean: 0.0288 +/- 0.0041 rms: 0.0096 +/- 0.0029
hostname:sdfmilan216 cpu:067 cmt:v64 proc time (sec) mean: 0.0288 +/- 0.0040 rms: 0.0094 +/- 0.0028
hostname:sdfmilan216 cpu:068 cmt:v64 proc time (sec) mean: 0.0303 +/- 0.0038 rms: 0.0099 +/- 0.0027
hostname:sdfmilan216 cpu:069 cmt:v64 proc time (sec) mean: 0.0302 +/- 0.0036 rms: 0.0100 +/- 0.0026
hostname:sdfmilan216 cpu:070 cmt:v64 proc time (sec) mean: 0.0308 +/- 0.0042 rms: 0.0103 +/- 0.0030
hostname:sdfmilan216 cpu:071 cmt:v64 proc time (sec) mean: 0.0304 +/- 0.0044 rms: 0.0101 +/- 0.0031
hostname:sdfmilan216 cpu:072 cmt:v64 proc time (sec) mean: 0.0310 +/- 0.0038 rms: 0.0101 +/- 0.0027
hostname:sdfmilan216 cpu:073 cmt:v64 proc time (sec) mean: 0.0299 +/- 0.0037 rms: 0.0100 +/- 0.0026
hostname:sdfmilan216 cpu:074 cmt:v64 proc time (sec) mean: 0.0301 +/- 0.0037 rms: 0.0101 +/- 0.0026
hostname:sdfmilan216 cpu:075 cmt:v64 proc time (sec) mean: 0.0286 +/- 0.0042 rms: 0.0091 +/- 0.0029
hostname:sdfmilan216 cpu:076 cmt:v64 proc time (sec) mean: 0.0305 +/- 0.0037 rms: 0.0099 +/- 0.0026
hostname:sdfmilan216 cpu:077 cmt:v64 proc time (sec) mean: 0.0303 +/- 0.0039 rms: 0.0100 +/- 0.0028
hostname:sdfmilan216 cpu:078 cmt:v64 proc time (sec) mean: 0.0284 +/- 0.0044 rms: 0.0089 +/- 0.0031
hostname:sdfmilan216 cpu:079 cmt:v64 proc time (sec) mean: 0.0307 +/- 0.0037 rms: 0.0103 +/- 0.0026
hostname:sdfmilan216 cpu:080 cmt:v64 proc time (sec) mean: 0.0291 +/- 0.0047 rms: 0.0091 +/- 0.0033
hostname:sdfmilan216 cpu:081 cmt:v64 proc time (sec) mean: 0.0292 +/- 0.0043 rms: 0.0091 +/- 0.0031
hostname:sdfmilan216 cpu:082 cmt:v64 proc time (sec) mean: 0.0287 +/- 0.0045 rms: 0.0089 +/- 0.0032
hostname:sdfmilan216 cpu:083 cmt:v64 proc time (sec) mean: 0.0289 +/- 0.0042 rms: 0.0091 +/- 0.0030
hostname:sdfmilan216 cpu:084 cmt:v64 proc time (sec) mean: 0.0292 +/- 0.0044 rms: 0.0092 +/- 0.0031
hostname:sdfmilan216 cpu:085 cmt:v64 proc time (sec) mean: 0.0291 +/- 0.0041 rms: 0.0091 +/- 0.0029
hostname:sdfmilan216 cpu:086 cmt:v64 proc time (sec) mean: 0.0292 +/- 0.0045 rms: 0.0092 +/- 0.0032
hostname:sdfmilan216 cpu:087 cmt:v64 proc time (sec) mean: 0.0294 +/- 0.0040 rms: 0.0095 +/- 0.0028
hostname:sdfmilan216 cpu:088 cmt:v64 proc time (sec) mean: 0.0298 +/- 0.0041 rms: 0.0094 +/- 0.0029
hostname:sdfmilan216 cpu:089 cmt:v64 proc time (sec) mean: 0.0289 +/- 0.0044 rms: 0.0091 +/- 0.0031
hostname:sdfmilan216 cpu:090 cmt:v64 proc time (sec) mean: 0.0299 +/- 0.0043 rms: 0.0094 +/- 0.0030
hostname:sdfmilan216 cpu:091 cmt:v64 proc time (sec) mean: 0.0288 +/- 0.0044 rms: 0.0090 +/- 0.0031
hostname:sdfmilan216 cpu:092 cmt:v64 proc time (sec) mean: 0.0301 +/- 0.0039 rms: 0.0097 +/- 0.0028
hostname:sdfmilan216 cpu:093 cmt:v64 proc time (sec) mean: 0.0292 +/- 0.0039 rms: 0.0093 +/- 0.0028
hostname:sdfmilan216 cpu:094 cmt:v64 proc time (sec) mean: 0.0289 +/- 0.0044 rms: 0.0091 +/- 0.0031
hostname:sdfmilan216 cpu:095 cmt:v64 proc time (sec) mean: 0.0297 +/- 0.0042 rms: 0.0094 +/- 0.0029
hostname:sdfmilan216 cpu:096 cmt:v64 proc time (sec) mean: 0.0263 +/- 0.0058 rms: 0.0080 +/- 0.0041
hostname:sdfmilan216 cpu:097 cmt:v64 proc time (sec) mean: 0.0259 +/- 0.0055 rms: 0.0079 +/- 0.0039
hostname:sdfmilan216 cpu:098 cmt:v64 proc time (sec) mean: 0.0262 +/- 0.0057 rms: 0.0080 +/- 0.0040
hostname:sdfmilan216 cpu:099 cmt:v64 proc time (sec) mean: 0.0263 +/- 0.0061 rms: 0.0080 +/- 0.0043
hostname:sdfmilan216 cpu:100 cmt:v64 proc time (sec) mean: 0.0262 +/- 0.0061 rms: 0.0080 +/- 0.0043
hostname:sdfmilan216 cpu:101 cmt:v64 proc time (sec) mean: 0.0259 +/- 0.0053 rms: 0.0079 +/- 0.0037
hostname:sdfmilan216 cpu:102 cmt:v64 proc time (sec) mean: 0.0263 +/- 0.0065 rms: 0.0080 +/- 0.0046
hostname:sdfmilan216 cpu:103 cmt:v64 proc time (sec) mean: 0.0260 +/- 0.0053 rms: 0.0079 +/- 0.0038
hostname:sdfmilan216 cpu:104 cmt:v64 proc time (sec) mean: 0.0262 +/- 0.0054 rms: 0.0080 +/- 0.0038
hostname:sdfmilan216 cpu:105 cmt:v64 proc time (sec) mean: 0.0262 +/- 0.0058 rms: 0.0080 +/- 0.0041
hostname:sdfmilan216 cpu:106 cmt:v64 proc time (sec) mean: 0.0263 +/- 0.0059 rms: 0.0080 +/- 0.0041
hostname:sdfmilan216 cpu:107 cmt:v64 proc time (sec) mean: 0.0262 +/- 0.0058 rms: 0.0080 +/- 0.0041
hostname:sdfmilan216 cpu:108 cmt:v64 proc time (sec) mean: 0.0262 +/- 0.0057 rms: 0.0080 +/- 0.0040
hostname:sdfmilan216 cpu:109 cmt:v64 proc time (sec) mean: 0.0263 +/- 0.0055 rms: 0.0080 +/- 0.0039
hostname:sdfmilan216 cpu:110 cmt:v64 proc time (sec) mean: 0.0258 +/- 0.0051 rms: 0.0079 +/- 0.0036
hostname:sdfmilan216 cpu:111 cmt:v64 proc time (sec) mean: 0.0263 +/- 0.0055 rms: 0.0080 +/- 0.0039
hostname:sdfmilan216 cpu:112 cmt:v64 proc time (sec) mean: 0.0262 +/- 0.0059 rms: 0.0080 +/- 0.0042
hostname:sdfmilan216 cpu:113 cmt:v64 proc time (sec) mean: 0.0261 +/- 0.0053 rms: 0.0080 +/- 0.0037
hostname:sdfmilan216 cpu:114 cmt:v64 proc time (sec) mean: 0.0261 +/- 0.0050 rms: 0.0080 +/- 0.0035
hostname:sdfmilan216 cpu:115 cmt:v64 proc time (sec) mean: 0.0263 +/- 0.0058 rms: 0.0080 +/- 0.0041
hostname:sdfmilan216 cpu:116 cmt:v64 proc time (sec) mean: 0.0263 +/- 0.0056 rms: 0.0080 +/- 0.0039
hostname:sdfmilan216 cpu:117 cmt:v64 proc time (sec) mean: 0.0263 +/- 0.0059 rms: 0.0080 +/- 0.0041
hostname:sdfmilan216 cpu:118 cmt:v64 proc time (sec) mean: 0.0264 +/- 0.0063 rms: 0.0080 +/- 0.0045
hostname:sdfmilan216 cpu:119 cmt:v64 proc time (sec) mean: 0.0262 +/- 0.0053 rms: 0.0080 +/- 0.0038
hostname:sdfmilan216 cpu:120 cmt:v64 proc time (sec) mean: 0.0257 +/- 0.0052 rms: 0.0078 +/- 0.0037
hostname:sdfmilan216 cpu:121 cmt:v64 proc time (sec) mean: 0.0261 +/- 0.0058 rms: 0.0079 +/- 0.0041
hostname:sdfmilan216 cpu:122 cmt:v64 proc time (sec) mean: 0.0262 +/- 0.0058 rms: 0.0080 +/- 0.0041
hostname:sdfmilan216 cpu:123 cmt:v64 proc time (sec) mean: 0.0263 +/- 0.0063 rms: 0.0080 +/- 0.0044
hostname:sdfmilan216 cpu:124 cmt:v64 proc time (sec) mean: 0.0263 +/- 0.0057 rms: 0.0080 +/- 0.0040
hostname:sdfmilan216 cpu:125 cmt:v64 proc time (sec) mean: 0.0262 +/- 0.0056 rms: 0.0080 +/- 0.0040
hostname:sdfmilan216 cpu:126 cmt:v64 proc time (sec) mean: 0.0261 +/- 0.0056 rms: 0.0080 +/- 0.0040
hostname:sdfmilan216 cpu:127 cmt:v64 proc time (sec) mean: 0.0259 +/- 0.0052 rms: 0.0079 +/- 0.0037
mean time (sec): 0.0278



sort_records_in_file: figs/fig-subpr32-512k-v120-sdfmilan216-summary.txt
records:
means: shape:(120,) size:120 dtype:float64
[0.0263 0.0263 0.0263 0.0264 0.0264 0.0262 0.0262 0.0263 0.0262 0.0262
 0.0263 0.0262 0.0264 0.0265 0.0264 0.0261 0.0262 0.0262 0.0263 0.0263
 0.0263 0.0263 0.026  0.0263 0.0268 0.0265 0.0264 0.0265 0.0266 0.0265
 0.0264 0.0266 0.0263 0.0265 0.0264 0.0265 0.0265 0.0264 0.0264 0.0265
 0.0264 0.0262 0.0265 0.0264 0.0264 0.0264 0.0268 0.0264 0.0266 0.0265
 0.027  0.0265 0.0266 0.0266 0.0266 0.0264 0.0298 0.0319 0.0305 0.03
 0.0324 0.0292 0.0309 0.0309 0.0309 0.0303 0.0317 0.0317 0.0302 0.0288
 0.0308 0.0318 0.0287 0.0285 0.0292 0.0293 0.0292 0.0289 0.0297 0.0291
 0.029  0.0296 0.0294 0.0294 0.0296 0.0292 0.0296 0.0293 0.026  0.0261
 0.0259 0.0263 0.0261 0.0259 0.0259 0.026  0.0261 0.0259 0.0259 0.0279...]
mean time (sec): 0.0273

hostname:sdfmilan216 cpu:000 cmt:v120 proc time (sec) mean: 0.0263 +/- 0.0061 rms: 0.0081 +/- 0.0043
hostname:sdfmilan216 cpu:001 cmt:v120 proc time (sec) mean: 0.0263 +/- 0.0062 rms: 0.0080 +/- 0.0044
hostname:sdfmilan216 cpu:002 cmt:v120 proc time (sec) mean: 0.0263 +/- 0.0058 rms: 0.0080 +/- 0.0041
hostname:sdfmilan216 cpu:003 cmt:v120 proc time (sec) mean: 0.0264 +/- 0.0059 rms: 0.0080 +/- 0.0042
hostname:sdfmilan216 cpu:004 cmt:v120 proc time (sec) mean: 0.0264 +/- 0.0059 rms: 0.0081 +/- 0.0041
hostname:sdfmilan216 cpu:005 cmt:v120 proc time (sec) mean: 0.0262 +/- 0.0060 rms: 0.0080 +/- 0.0043
hostname:sdfmilan216 cpu:006 cmt:v120 proc time (sec) mean: 0.0262 +/- 0.0059 rms: 0.0080 +/- 0.0042
hostname:sdfmilan216 cpu:007 cmt:v120 proc time (sec) mean: 0.0263 +/- 0.0062 rms: 0.0080 +/- 0.0044
hostname:sdfmilan216 cpu:008 cmt:v120 proc time (sec) mean: 0.0262 +/- 0.0062 rms: 0.0080 +/- 0.0044
hostname:sdfmilan216 cpu:009 cmt:v120 proc time (sec) mean: 0.0262 +/- 0.0056 rms: 0.0080 +/- 0.0040
hostname:sdfmilan216 cpu:010 cmt:v120 proc time (sec) mean: 0.0263 +/- 0.0056 rms: 0.0081 +/- 0.0039
hostname:sdfmilan216 cpu:011 cmt:v120 proc time (sec) mean: 0.0262 +/- 0.0061 rms: 0.0080 +/- 0.0043
hostname:sdfmilan216 cpu:012 cmt:v120 proc time (sec) mean: 0.0264 +/- 0.0062 rms: 0.0080 +/- 0.0044
hostname:sdfmilan216 cpu:013 cmt:v120 proc time (sec) mean: 0.0265 +/- 0.0063 rms: 0.0080 +/- 0.0044
hostname:sdfmilan216 cpu:014 cmt:v120 proc time (sec) mean: 0.0264 +/- 0.0059 rms: 0.0080 +/- 0.0041
hostname:sdfmilan216 cpu:015 cmt:v120 proc time (sec) mean: 0.0261 +/- 0.0058 rms: 0.0080 +/- 0.0041
hostname:sdfmilan216 cpu:024 cmt:v120 proc time (sec) mean: 0.0262 +/- 0.0060 rms: 0.0080 +/- 0.0043
hostname:sdfmilan216 cpu:025 cmt:v120 proc time (sec) mean: 0.0262 +/- 0.0061 rms: 0.0080 +/- 0.0043
hostname:sdfmilan216 cpu:026 cmt:v120 proc time (sec) mean: 0.0263 +/- 0.0065 rms: 0.0080 +/- 0.0046
hostname:sdfmilan216 cpu:027 cmt:v120 proc time (sec) mean: 0.0263 +/- 0.0063 rms: 0.0080 +/- 0.0045
hostname:sdfmilan216 cpu:028 cmt:v120 proc time (sec) mean: 0.0263 +/- 0.0064 rms: 0.0080 +/- 0.0045
hostname:sdfmilan216 cpu:029 cmt:v120 proc time (sec) mean: 0.0263 +/- 0.0064 rms: 0.0080 +/- 0.0045
hostname:sdfmilan216 cpu:030 cmt:v120 proc time (sec) mean: 0.0260 +/- 0.0059 rms: 0.0080 +/- 0.0042
hostname:sdfmilan216 cpu:031 cmt:v120 proc time (sec) mean: 0.0263 +/- 0.0066 rms: 0.0080 +/- 0.0047
hostname:sdfmilan216 cpu:032 cmt:v120 proc time (sec) mean: 0.0268 +/- 0.0072 rms: 0.0099 +/- 0.0051
hostname:sdfmilan216 cpu:033 cmt:v120 proc time (sec) mean: 0.0265 +/- 0.0062 rms: 0.0081 +/- 0.0044
hostname:sdfmilan216 cpu:034 cmt:v120 proc time (sec) mean: 0.0264 +/- 0.0062 rms: 0.0080 +/- 0.0044
hostname:sdfmilan216 cpu:035 cmt:v120 proc time (sec) mean: 0.0265 +/- 0.0064 rms: 0.0081 +/- 0.0046
hostname:sdfmilan216 cpu:036 cmt:v120 proc time (sec) mean: 0.0266 +/- 0.0059 rms: 0.0081 +/- 0.0041
hostname:sdfmilan216 cpu:037 cmt:v120 proc time (sec) mean: 0.0265 +/- 0.0061 rms: 0.0081 +/- 0.0043
hostname:sdfmilan216 cpu:038 cmt:v120 proc time (sec) mean: 0.0264 +/- 0.0066 rms: 0.0080 +/- 0.0046
hostname:sdfmilan216 cpu:039 cmt:v120 proc time (sec) mean: 0.0266 +/- 0.0059 rms: 0.0081 +/- 0.0042
hostname:sdfmilan216 cpu:040 cmt:v120 proc time (sec) mean: 0.0263 +/- 0.0064 rms: 0.0080 +/- 0.0045
hostname:sdfmilan216 cpu:041 cmt:v120 proc time (sec) mean: 0.0265 +/- 0.0061 rms: 0.0081 +/- 0.0043
hostname:sdfmilan216 cpu:042 cmt:v120 proc time (sec) mean: 0.0264 +/- 0.0062 rms: 0.0080 +/- 0.0044
hostname:sdfmilan216 cpu:043 cmt:v120 proc time (sec) mean: 0.0265 +/- 0.0062 rms: 0.0081 +/- 0.0044
hostname:sdfmilan216 cpu:044 cmt:v120 proc time (sec) mean: 0.0265 +/- 0.0063 rms: 0.0080 +/- 0.0044
hostname:sdfmilan216 cpu:045 cmt:v120 proc time (sec) mean: 0.0264 +/- 0.0065 rms: 0.0080 +/- 0.0046
hostname:sdfmilan216 cpu:046 cmt:v120 proc time (sec) mean: 0.0264 +/- 0.0062 rms: 0.0080 +/- 0.0044
hostname:sdfmilan216 cpu:047 cmt:v120 proc time (sec) mean: 0.0265 +/- 0.0066 rms: 0.0081 +/- 0.0046
hostname:sdfmilan216 cpu:048 cmt:v120 proc time (sec) mean: 0.0264 +/- 0.0062 rms: 0.0080 +/- 0.0044
hostname:sdfmilan216 cpu:049 cmt:v120 proc time (sec) mean: 0.0262 +/- 0.0059 rms: 0.0080 +/- 0.0042
hostname:sdfmilan216 cpu:050 cmt:v120 proc time (sec) mean: 0.0265 +/- 0.0061 rms: 0.0081 +/- 0.0043
hostname:sdfmilan216 cpu:051 cmt:v120 proc time (sec) mean: 0.0264 +/- 0.0064 rms: 0.0080 +/- 0.0045
hostname:sdfmilan216 cpu:052 cmt:v120 proc time (sec) mean: 0.0264 +/- 0.0065 rms: 0.0080 +/- 0.0046
hostname:sdfmilan216 cpu:053 cmt:v120 proc time (sec) mean: 0.0264 +/- 0.0066 rms: 0.0080 +/- 0.0047
hostname:sdfmilan216 cpu:054 cmt:v120 proc time (sec) mean: 0.0268 +/- 0.0059 rms: 0.0082 +/- 0.0042
hostname:sdfmilan216 cpu:055 cmt:v120 proc time (sec) mean: 0.0264 +/- 0.0059 rms: 0.0081 +/- 0.0041
hostname:sdfmilan216 cpu:056 cmt:v120 proc time (sec) mean: 0.0266 +/- 0.0064 rms: 0.0081 +/- 0.0045
hostname:sdfmilan216 cpu:057 cmt:v120 proc time (sec) mean: 0.0265 +/- 0.0060 rms: 0.0081 +/- 0.0043
hostname:sdfmilan216 cpu:058 cmt:v120 proc time (sec) mean: 0.0270 +/- 0.0078 rms: 0.0125 +/- 0.0055
hostname:sdfmilan216 cpu:059 cmt:v120 proc time (sec) mean: 0.0265 +/- 0.0062 rms: 0.0081 +/- 0.0044
hostname:sdfmilan216 cpu:060 cmt:v120 proc time (sec) mean: 0.0266 +/- 0.0056 rms: 0.0081 +/- 0.0040
hostname:sdfmilan216 cpu:061 cmt:v120 proc time (sec) mean: 0.0266 +/- 0.0056 rms: 0.0081 +/- 0.0040
hostname:sdfmilan216 cpu:062 cmt:v120 proc time (sec) mean: 0.0266 +/- 0.0059 rms: 0.0081 +/- 0.0042
hostname:sdfmilan216 cpu:063 cmt:v120 proc time (sec) mean: 0.0264 +/- 0.0053 rms: 0.0081 +/- 0.0038
hostname:sdfmilan216 cpu:064 cmt:v120 proc time (sec) mean: 0.0298 +/- 0.0039 rms: 0.0097 +/- 0.0028
hostname:sdfmilan216 cpu:065 cmt:v120 proc time (sec) mean: 0.0319 +/- 0.0037 rms: 0.0105 +/- 0.0026
hostname:sdfmilan216 cpu:066 cmt:v120 proc time (sec) mean: 0.0305 +/- 0.0038 rms: 0.0102 +/- 0.0027
hostname:sdfmilan216 cpu:067 cmt:v120 proc time (sec) mean: 0.0300 +/- 0.0043 rms: 0.0096 +/- 0.0030
hostname:sdfmilan216 cpu:068 cmt:v120 proc time (sec) mean: 0.0324 +/- 0.0037 rms: 0.0107 +/- 0.0026
hostname:sdfmilan216 cpu:069 cmt:v120 proc time (sec) mean: 0.0292 +/- 0.0040 rms: 0.0093 +/- 0.0029
hostname:sdfmilan216 cpu:070 cmt:v120 proc time (sec) mean: 0.0309 +/- 0.0037 rms: 0.0101 +/- 0.0026
hostname:sdfmilan216 cpu:071 cmt:v120 proc time (sec) mean: 0.0309 +/- 0.0038 rms: 0.0101 +/- 0.0027
hostname:sdfmilan216 cpu:072 cmt:v120 proc time (sec) mean: 0.0309 +/- 0.0041 rms: 0.0103 +/- 0.0029
hostname:sdfmilan216 cpu:073 cmt:v120 proc time (sec) mean: 0.0303 +/- 0.0043 rms: 0.0102 +/- 0.0031
hostname:sdfmilan216 cpu:074 cmt:v120 proc time (sec) mean: 0.0317 +/- 0.0042 rms: 0.0113 +/- 0.0030
hostname:sdfmilan216 cpu:075 cmt:v120 proc time (sec) mean: 0.0317 +/- 0.0040 rms: 0.0108 +/- 0.0028
hostname:sdfmilan216 cpu:076 cmt:v120 proc time (sec) mean: 0.0302 +/- 0.0044 rms: 0.0101 +/- 0.0031
hostname:sdfmilan216 cpu:077 cmt:v120 proc time (sec) mean: 0.0288 +/- 0.0041 rms: 0.0091 +/- 0.0029
hostname:sdfmilan216 cpu:078 cmt:v120 proc time (sec) mean: 0.0308 +/- 0.0039 rms: 0.0100 +/- 0.0028
hostname:sdfmilan216 cpu:079 cmt:v120 proc time (sec) mean: 0.0318 +/- 0.0043 rms: 0.0114 +/- 0.0030
hostname:sdfmilan216 cpu:080 cmt:v120 proc time (sec) mean: 0.0287 +/- 0.0044 rms: 0.0089 +/- 0.0031
hostname:sdfmilan216 cpu:081 cmt:v120 proc time (sec) mean: 0.0285 +/- 0.0045 rms: 0.0089 +/- 0.0032
hostname:sdfmilan216 cpu:082 cmt:v120 proc time (sec) mean: 0.0292 +/- 0.0042 rms: 0.0092 +/- 0.0030
hostname:sdfmilan216 cpu:083 cmt:v120 proc time (sec) mean: 0.0293 +/- 0.0044 rms: 0.0091 +/- 0.0031
hostname:sdfmilan216 cpu:084 cmt:v120 proc time (sec) mean: 0.0292 +/- 0.0044 rms: 0.0091 +/- 0.0031
hostname:sdfmilan216 cpu:085 cmt:v120 proc time (sec) mean: 0.0289 +/- 0.0042 rms: 0.0091 +/- 0.0030
hostname:sdfmilan216 cpu:086 cmt:v120 proc time (sec) mean: 0.0297 +/- 0.0039 rms: 0.0095 +/- 0.0028
hostname:sdfmilan216 cpu:087 cmt:v120 proc time (sec) mean: 0.0291 +/- 0.0043 rms: 0.0091 +/- 0.0030
hostname:sdfmilan216 cpu:088 cmt:v120 proc time (sec) mean: 0.0290 +/- 0.0042 rms: 0.0091 +/- 0.0030
hostname:sdfmilan216 cpu:089 cmt:v120 proc time (sec) mean: 0.0296 +/- 0.0040 rms: 0.0096 +/- 0.0028
hostname:sdfmilan216 cpu:090 cmt:v120 proc time (sec) mean: 0.0294 +/- 0.0041 rms: 0.0093 +/- 0.0029
hostname:sdfmilan216 cpu:091 cmt:v120 proc time (sec) mean: 0.0294 +/- 0.0042 rms: 0.0093 +/- 0.0030
hostname:sdfmilan216 cpu:092 cmt:v120 proc time (sec) mean: 0.0296 +/- 0.0045 rms: 0.0094 +/- 0.0032
hostname:sdfmilan216 cpu:093 cmt:v120 proc time (sec) mean: 0.0292 +/- 0.0043 rms: 0.0092 +/- 0.0031
hostname:sdfmilan216 cpu:094 cmt:v120 proc time (sec) mean: 0.0296 +/- 0.0040 rms: 0.0094 +/- 0.0028
hostname:sdfmilan216 cpu:095 cmt:v120 proc time (sec) mean: 0.0293 +/- 0.0041 rms: 0.0094 +/- 0.0029
hostname:sdfmilan216 cpu:096 cmt:v120 proc time (sec) mean: 0.0260 +/- 0.0056 rms: 0.0079 +/- 0.0039
hostname:sdfmilan216 cpu:097 cmt:v120 proc time (sec) mean: 0.0261 +/- 0.0057 rms: 0.0080 +/- 0.0040
hostname:sdfmilan216 cpu:098 cmt:v120 proc time (sec) mean: 0.0259 +/- 0.0053 rms: 0.0079 +/- 0.0037
hostname:sdfmilan216 cpu:099 cmt:v120 proc time (sec) mean: 0.0263 +/- 0.0057 rms: 0.0081 +/- 0.0040
hostname:sdfmilan216 cpu:100 cmt:v120 proc time (sec) mean: 0.0261 +/- 0.0057 rms: 0.0079 +/- 0.0040
hostname:sdfmilan216 cpu:101 cmt:v120 proc time (sec) mean: 0.0259 +/- 0.0052 rms: 0.0079 +/- 0.0037
hostname:sdfmilan216 cpu:102 cmt:v120 proc time (sec) mean: 0.0259 +/- 0.0052 rms: 0.0079 +/- 0.0037
hostname:sdfmilan216 cpu:103 cmt:v120 proc time (sec) mean: 0.0260 +/- 0.0054 rms: 0.0079 +/- 0.0038
hostname:sdfmilan216 cpu:104 cmt:v120 proc time (sec) mean: 0.0261 +/- 0.0056 rms: 0.0079 +/- 0.0039
hostname:sdfmilan216 cpu:105 cmt:v120 proc time (sec) mean: 0.0259 +/- 0.0054 rms: 0.0079 +/- 0.0038
hostname:sdfmilan216 cpu:106 cmt:v120 proc time (sec) mean: 0.0259 +/- 0.0050 rms: 0.0079 +/- 0.0036
hostname:sdfmilan216 cpu:107 cmt:v120 proc time (sec) mean: 0.0279 +/- 0.0130 rms: 0.0188 +/- 0.0092
hostname:sdfmilan216 cpu:108 cmt:v120 proc time (sec) mean: 0.0262 +/- 0.0060 rms: 0.0080 +/- 0.0042
hostname:sdfmilan216 cpu:109 cmt:v120 proc time (sec) mean: 0.0261 +/- 0.0059 rms: 0.0079 +/- 0.0042
hostname:sdfmilan216 cpu:110 cmt:v120 proc time (sec) mean: 0.0262 +/- 0.0055 rms: 0.0080 +/- 0.0039
hostname:sdfmilan216 cpu:111 cmt:v120 proc time (sec) mean: 0.0261 +/- 0.0054 rms: 0.0080 +/- 0.0038
hostname:sdfmilan216 cpu:112 cmt:v120 proc time (sec) mean: 0.0262 +/- 0.0055 rms: 0.0081 +/- 0.0039
hostname:sdfmilan216 cpu:113 cmt:v120 proc time (sec) mean: 0.0258 +/- 0.0052 rms: 0.0079 +/- 0.0037
hostname:sdfmilan216 cpu:114 cmt:v120 proc time (sec) mean: 0.0262 +/- 0.0059 rms: 0.0080 +/- 0.0042
hostname:sdfmilan216 cpu:115 cmt:v120 proc time (sec) mean: 0.0260 +/- 0.0056 rms: 0.0079 +/- 0.0040
hostname:sdfmilan216 cpu:116 cmt:v120 proc time (sec) mean: 0.0260 +/- 0.0054 rms: 0.0079 +/- 0.0038
hostname:sdfmilan216 cpu:117 cmt:v120 proc time (sec) mean: 0.0262 +/- 0.0061 rms: 0.0080 +/- 0.0043
hostname:sdfmilan216 cpu:118 cmt:v120 proc time (sec) mean: 0.0260 +/- 0.0053 rms: 0.0079 +/- 0.0037
hostname:sdfmilan216 cpu:119 cmt:v120 proc time (sec) mean: 0.0261 +/- 0.0058 rms: 0.0080 +/- 0.0041
hostname:sdfmilan216 cpu:120 cmt:v120 proc time (sec) mean: 0.0270 +/- 0.0083 rms: 0.0108 +/- 0.0058
hostname:sdfmilan216 cpu:121 cmt:v120 proc time (sec) mean: 0.0260 +/- 0.0054 rms: 0.0079 +/- 0.0038
hostname:sdfmilan216 cpu:122 cmt:v120 proc time (sec) mean: 0.0267 +/- 0.0069 rms: 0.0102 +/- 0.0049
hostname:sdfmilan216 cpu:123 cmt:v120 proc time (sec) mean: 0.0260 +/- 0.0057 rms: 0.0079 +/- 0.0040
hostname:sdfmilan216 cpu:124 cmt:v120 proc time (sec) mean: 0.0261 +/- 0.0058 rms: 0.0079 +/- 0.0041
hostname:sdfmilan216 cpu:125 cmt:v120 proc time (sec) mean: 0.0262 +/- 0.0057 rms: 0.0080 +/- 0.0040
hostname:sdfmilan216 cpu:126 cmt:v120 proc time (sec) mean: 0.0260 +/- 0.0053 rms: 0.0079 +/- 0.0038
hostname:sdfmilan216 cpu:127 cmt:v120 proc time (sec) mean: 0.0263 +/- 0.0060 rms: 0.0080 +/- 0.0042
mean time (sec): 0.0273
ana-4.0.59-py3 [dubrovin@sdfmilan216:~/LCLS/con-py3]$

Summary

Per-CPU, per-event time consumption, ms

Number

CPUs

CPU

numbers

float64

8panel

Ratio

N/1

float32

8panel

Ratio

N/1

float32

1panel

Ratio

N/1

15,10,64,127172.31172.3120.81
80-81991.151891.1021.41.03
160-152571.492231.2921.81.05
3232-632601.512291.3322.81.10
6464-1274932.863452.0027.81.34
120all but 16-23 weka 3792.193031.7627.31.31
  • Max consumed time is observed for 64-CPU occupancy, not for 120 ...
  • Reduction of memory consumption improves scaling

2024-02-16 jungfrau single panel timing in real data

Description

Commands
srun --partition milano --reservation=lcls:scaling --account lcls:prjdat21 -n 1 --time=02:00:00 --exclusive --pty /bin/bash

IN OTHER WINDOW:

ssh -Y sdfmilan216
cd LCLS/con-py3

source /sdf/group/lcls/ds/ana/sw/conda1/manage/bin/psconda.sh
source /sdf/group/lcls/ds/ana/sw/conda1/manage/bin/setup_testrel

mpirun -n 1 python  Detector/examples/test-scaling-mpi.py 2
mpirun -n 80 python Detector/examples/test-scaling-mpi.py 2

python Detector/examples/test-scaling-mpi.py -99 # to order results in file for rank number
Code of the event loop and timing
    ds = MPIDataSource('exp=xcsx1003522:run=33') # 72257 events
    det = Detector('XcsEndstation.0:Jungfrau.1')

    for nevt,evt in enumerate(ds.events()):
        raw = det.raw(evt) # prefetch the data from disk
        if raw is None: continue
        if nevt >= nevents: break
        t0_sec = time()
        calib = det.calib(evt)   ##### TIMING FOR det.calib
        dt_sec = time()-t0_sec

        arrts[nevt] = dt_sec

Results

Timing results for single core and 80-code mpi processing
single-core processing
======================

mpirun -n 1 python Detector/examples/test-scaling-mpi.py 2

figs/fig-mpi-data-1p-v01-sdfmilan216-ncores01-summary.txt
python Detector/examples/test-scaling-mpi.py -99
figs/fig-mpi-data-1p-v01-sdfmilan216-ncores01-summary-ordered.txt

hostname:sdfmilan216 rank:000 cpu:000 cmt:1p-v01 proc time (sec) mean: 0.0424 +/- 0.0011 rms: 0.0011 +/- 0.0007
hostname:sdfmilan216 rank:000 cpu:000 cmt:1p-v01 proc time (sec) mean: 0.0425 +/- 0.0007 rms: 0.0007 +/- 0.0005
hostname:sdfmilan216 rank:000 cpu:000 cmt:1p-v01 proc time (sec) mean: 0.0425 +/- 0.0008 rms: 0.0009 +/- 0.0006
hostname:sdfmilan216 rank:000 cpu:000 cmt:1p-v01 proc time (sec) mean: 0.0426 +/- 0.0007 rms: 0.0007 +/- 0.0005
mean time (sec): 0.0425


80-core processing
==================

mpirun -n 80 python Detector/examples/test-scaling-mpi.py 2
python Detector/examples/test-scaling-mpi.py -99
figs/fig-mpi-data-1p-v00-sdfmilan216-ncores80-summary-ordered.txt

hostname:sdfmilan216 rank:000 cpu:000 cmt:1p-v00 proc time (sec) mean: 0.0891 +/- 0.0068 rms: 0.0273 +/- 0.0048
hostname:sdfmilan216 rank:001 cpu:027 cmt:1p-v00 proc time (sec) mean: 0.0689 +/- 0.0027 rms: 0.0048 +/- 0.0019
hostname:sdfmilan216 rank:002 cpu:035 cmt:1p-v00 proc time (sec) mean: 0.0706 +/- 0.0029 rms: 0.0059 +/- 0.0020
hostname:sdfmilan216 rank:003 cpu:055 cmt:1p-v00 proc time (sec) mean: 0.0577 +/- 0.0031 rms: 0.0061 +/- 0.0022
hostname:sdfmilan216 rank:004 cpu:072 cmt:1p-v00 proc time (sec) mean: 0.0883 +/- 0.0072 rms: 0.0235 +/- 0.0051
hostname:sdfmilan216 rank:005 cpu:094 cmt:1p-v00 proc time (sec) mean: 0.0893 +/- 0.0067 rms: 0.0253 +/- 0.0047
hostname:sdfmilan216 rank:006 cpu:103 cmt:1p-v00 proc time (sec) mean: 0.1082 +/- 0.0142 rms: 0.0520 +/- 0.0101
hostname:sdfmilan216 rank:007 cpu:125 cmt:1p-v00 proc time (sec) mean: 0.1131 +/- 0.0161 rms: 0.0583 +/- 0.0114
hostname:sdfmilan216 rank:008 cpu:014 cmt:1p-v00 proc time (sec) mean: 0.0923 +/- 0.0072 rms: 0.0293 +/- 0.0051
hostname:sdfmilan216 rank:009 cpu:028 cmt:1p-v00 proc time (sec) mean: 0.0742 +/- 0.0031 rms: 0.0058 +/- 0.0022
hostname:sdfmilan216 rank:010 cpu:044 cmt:1p-v00 proc time (sec) mean: 0.0711 +/- 0.0040 rms: 0.0099 +/- 0.0028
hostname:sdfmilan216 rank:011 cpu:051 cmt:1p-v00 proc time (sec) mean: 0.0578 +/- 0.0027 rms: 0.0051 +/- 0.0019
hostname:sdfmilan216 rank:012 cpu:067 cmt:1p-v00 proc time (sec) mean: 0.0877 +/- 0.0079 rms: 0.0251 +/- 0.0056
hostname:sdfmilan216 rank:013 cpu:082 cmt:1p-v00 proc time (sec) mean: 0.0859 +/- 0.0061 rms: 0.0228 +/- 0.0043
hostname:sdfmilan216 rank:014 cpu:096 cmt:1p-v00 proc time (sec) mean: 0.1075 +/- 0.0139 rms: 0.0538 +/- 0.0098
hostname:sdfmilan216 rank:015 cpu:112 cmt:1p-v00 proc time (sec) mean: 0.1064 +/- 0.0161 rms: 0.0584 +/- 0.0114
hostname:sdfmilan216 rank:016 cpu:012 cmt:1p-v00 proc time (sec) mean: 0.0895 +/- 0.0062 rms: 0.0249 +/- 0.0044
hostname:sdfmilan216 rank:017 cpu:031 cmt:1p-v00 proc time (sec) mean: 0.0708 +/- 0.0029 rms: 0.0055 +/- 0.0021
hostname:sdfmilan216 rank:018 cpu:032 cmt:1p-v00 proc time (sec) mean: 0.0715 +/- 0.0032 rms: 0.0064 +/- 0.0023
hostname:sdfmilan216 rank:019 cpu:061 cmt:1p-v00 proc time (sec) mean: 0.0571 +/- 0.0027 rms: 0.0052 +/- 0.0019
hostname:sdfmilan216 rank:020 cpu:078 cmt:1p-v00 proc time (sec) mean: 0.0889 +/- 0.0067 rms: 0.0230 +/- 0.0047
hostname:sdfmilan216 rank:021 cpu:092 cmt:1p-v00 proc time (sec) mean: 0.0896 +/- 0.0069 rms: 0.0242 +/- 0.0049
hostname:sdfmilan216 rank:022 cpu:100 cmt:1p-v00 proc time (sec) mean: 0.1095 +/- 0.0146 rms: 0.0554 +/- 0.0103
hostname:sdfmilan216 rank:023 cpu:117 cmt:1p-v00 proc time (sec) mean: 0.1083 +/- 0.0167 rms: 0.0620 +/- 0.0118
hostname:sdfmilan216 rank:024 cpu:006 cmt:1p-v00 proc time (sec) mean: 0.0861 +/- 0.0064 rms: 0.0249 +/- 0.0045
hostname:sdfmilan216 rank:025 cpu:026 cmt:1p-v00 proc time (sec) mean: 0.0760 +/- 0.0029 rms: 0.0053 +/- 0.0021
hostname:sdfmilan216 rank:026 cpu:041 cmt:1p-v00 proc time (sec) mean: 0.0744 +/- 0.0036 rms: 0.0095 +/- 0.0026
hostname:sdfmilan216 rank:027 cpu:058 cmt:1p-v00 proc time (sec) mean: 0.0560 +/- 0.0024 rms: 0.0039 +/- 0.0017
hostname:sdfmilan216 rank:028 cpu:074 cmt:1p-v00 proc time (sec) mean: 0.0881 +/- 0.0078 rms: 0.0271 +/- 0.0055
hostname:sdfmilan216 rank:029 cpu:091 cmt:1p-v00 proc time (sec) mean: 0.0854 +/- 0.0069 rms: 0.0248 +/- 0.0049
hostname:sdfmilan216 rank:030 cpu:104 cmt:1p-v00 proc time (sec) mean: 0.1100 +/- 0.0155 rms: 0.0595 +/- 0.0110
hostname:sdfmilan216 rank:031 cpu:123 cmt:1p-v00 proc time (sec) mean: 0.1081 +/- 0.0140 rms: 0.0544 +/- 0.0099
hostname:sdfmilan216 rank:032 cpu:009 cmt:1p-v00 proc time (sec) mean: 0.0900 +/- 0.0063 rms: 0.0251 +/- 0.0044
hostname:sdfmilan216 rank:033 cpu:029 cmt:1p-v00 proc time (sec) mean: 0.0723 +/- 0.0028 rms: 0.0054 +/- 0.0020
hostname:sdfmilan216 rank:034 cpu:033 cmt:1p-v00 proc time (sec) mean: 0.0693 +/- 0.0035 rms: 0.0087 +/- 0.0025
hostname:sdfmilan216 rank:035 cpu:056 cmt:1p-v00 proc time (sec) mean: 0.0551 +/- 0.0019 rms: 0.0028 +/- 0.0014
hostname:sdfmilan216 rank:036 cpu:069 cmt:1p-v00 proc time (sec) mean: 0.0866 +/- 0.0068 rms: 0.0245 +/- 0.0048
hostname:sdfmilan216 rank:037 cpu:086 cmt:1p-v00 proc time (sec) mean: 0.0879 +/- 0.0071 rms: 0.0250 +/- 0.0050
hostname:sdfmilan216 rank:038 cpu:110 cmt:1p-v00 proc time (sec) mean: 0.1079 +/- 0.0148 rms: 0.0573 +/- 0.0105
hostname:sdfmilan216 rank:039 cpu:116 cmt:1p-v00 proc time (sec) mean: 0.1057 +/- 0.0147 rms: 0.0571 +/- 0.0104
hostname:sdfmilan216 rank:040 cpu:005 cmt:1p-v00 proc time (sec) mean: 0.0886 +/- 0.0068 rms: 0.0271 +/- 0.0048
hostname:sdfmilan216 rank:041 cpu:024 cmt:1p-v00 proc time (sec) mean: 0.0757 +/- 0.0028 rms: 0.0051 +/- 0.0020
hostname:sdfmilan216 rank:042 cpu:046 cmt:1p-v00 proc time (sec) mean: 0.0699 +/- 0.0035 rms: 0.0086 +/- 0.0025
hostname:sdfmilan216 rank:043 cpu:057 cmt:1p-v00 proc time (sec) mean: 0.0554 +/- 0.0023 rms: 0.0035 +/- 0.0016
hostname:sdfmilan216 rank:044 cpu:077 cmt:1p-v00 proc time (sec) mean: 0.0851 +/- 0.0063 rms: 0.0213 +/- 0.0045
hostname:sdfmilan216 rank:045 cpu:089 cmt:1p-v00 proc time (sec) mean: 0.0838 +/- 0.0066 rms: 0.0217 +/- 0.0046
hostname:sdfmilan216 rank:046 cpu:111 cmt:1p-v00 proc time (sec) mean: 0.1077 +/- 0.0146 rms: 0.0562 +/- 0.0103
hostname:sdfmilan216 rank:047 cpu:124 cmt:1p-v00 proc time (sec) mean: 0.1009 +/- 0.0135 rms: 0.0512 +/- 0.0096
hostname:sdfmilan216 rank:048 cpu:004 cmt:1p-v00 proc time (sec) mean: 0.0867 +/- 0.0066 rms: 0.0268 +/- 0.0047
hostname:sdfmilan216 rank:049 cpu:025 cmt:1p-v00 proc time (sec) mean: 0.0764 +/- 0.0028 rms: 0.0048 +/- 0.0020
hostname:sdfmilan216 rank:050 cpu:034 cmt:1p-v00 proc time (sec) mean: 0.0712 +/- 0.0039 rms: 0.0100 +/- 0.0027
hostname:sdfmilan216 rank:051 cpu:050 cmt:1p-v00 proc time (sec) mean: 0.0559 +/- 0.0027 rms: 0.0052 +/- 0.0019
hostname:sdfmilan216 rank:052 cpu:066 cmt:1p-v00 proc time (sec) mean: 0.0880 +/- 0.0069 rms: 0.0236 +/- 0.0049
hostname:sdfmilan216 rank:053 cpu:084 cmt:1p-v00 proc time (sec) mean: 0.0857 +/- 0.0062 rms: 0.0218 +/- 0.0044
hostname:sdfmilan216 rank:054 cpu:107 cmt:1p-v00 proc time (sec) mean: 0.1075 +/- 0.0156 rms: 0.0564 +/- 0.0110
hostname:sdfmilan216 rank:055 cpu:115 cmt:1p-v00 proc time (sec) mean: 0.1042 +/- 0.0156 rms: 0.0575 +/- 0.0110
hostname:sdfmilan216 rank:056 cpu:000 cmt:1p-v00 proc time (sec) mean: 0.0902 +/- 0.0068 rms: 0.0278 +/- 0.0048
hostname:sdfmilan216 rank:057 cpu:030 cmt:1p-v00 proc time (sec) mean: 0.0725 +/- 0.0025 rms: 0.0045 +/- 0.0018
hostname:sdfmilan216 rank:058 cpu:047 cmt:1p-v00 proc time (sec) mean: 0.0726 +/- 0.0035 rms: 0.0086 +/- 0.0025
hostname:sdfmilan216 rank:059 cpu:061 cmt:1p-v00 proc time (sec) mean: 0.0555 +/- 0.0024 rms: 0.0039 +/- 0.0017
hostname:sdfmilan216 rank:060 cpu:076 cmt:1p-v00 proc time (sec) mean: 0.0862 +/- 0.0070 rms: 0.0234 +/- 0.0050
hostname:sdfmilan216 rank:061 cpu:081 cmt:1p-v00 proc time (sec) mean: 0.0853 +/- 0.0060 rms: 0.0212 +/- 0.0042
hostname:sdfmilan216 rank:062 cpu:101 cmt:1p-v00 proc time (sec) mean: 0.1028 +/- 0.0130 rms: 0.0505 +/- 0.0092
hostname:sdfmilan216 rank:063 cpu:122 cmt:1p-v00 proc time (sec) mean: 0.1056 +/- 0.0150 rms: 0.0555 +/- 0.0106
hostname:sdfmilan216 rank:064 cpu:001 cmt:1p-v00 proc time (sec) mean: 0.0940 +/- 0.0067 rms: 0.0286 +/- 0.0047
hostname:sdfmilan216 rank:065 cpu:033 cmt:1p-v00 proc time (sec) mean: 0.0741 +/- 0.0035 rms: 0.0079 +/- 0.0025
hostname:sdfmilan216 rank:066 cpu:040 cmt:1p-v00 proc time (sec) mean: 0.0684 +/- 0.0042 rms: 0.0102 +/- 0.0030
hostname:sdfmilan216 rank:067 cpu:052 cmt:1p-v00 proc time (sec) mean: 0.0574 +/- 0.0028 rms: 0.0051 +/- 0.0020
hostname:sdfmilan216 rank:068 cpu:075 cmt:1p-v00 proc time (sec) mean: 0.0862 +/- 0.0061 rms: 0.0208 +/- 0.0043
hostname:sdfmilan216 rank:069 cpu:093 cmt:1p-v00 proc time (sec) mean: 0.0893 +/- 0.0073 rms: 0.0260 +/- 0.0052
hostname:sdfmilan216 rank:070 cpu:099 cmt:1p-v00 proc time (sec) mean: 0.1050 +/- 0.0138 rms: 0.0555 +/- 0.0098
hostname:sdfmilan216 rank:071 cpu:126 cmt:1p-v00 proc time (sec) mean: 0.1115 +/- 0.0150 rms: 0.0559 +/- 0.0106
hostname:sdfmilan216 rank:072 cpu:007 cmt:1p-v00 proc time (sec) mean: 0.0829 +/- 0.0066 rms: 0.0258 +/- 0.0046
hostname:sdfmilan216 rank:073 cpu:045 cmt:1p-v00 proc time (sec) mean: 0.0728 +/- 0.0036 rms: 0.0092 +/- 0.0025
hostname:sdfmilan216 rank:074 cpu:036 cmt:1p-v00 proc time (sec) mean: 0.0708 +/- 0.0033 rms: 0.0074 +/- 0.0024
hostname:sdfmilan216 rank:075 cpu:063 cmt:1p-v00 proc time (sec) mean: 0.0550 +/- 0.0021 rms: 0.0032 +/- 0.0015
hostname:sdfmilan216 rank:076 cpu:071 cmt:1p-v00 proc time (sec) mean: 0.0882 +/- 0.0071 rms: 0.0259 +/- 0.0050
hostname:sdfmilan216 rank:077 cpu:080 cmt:1p-v00 proc time (sec) mean: 0.0835 +/- 0.0057 rms: 0.0203 +/- 0.0040
hostname:sdfmilan216 rank:078 cpu:108 cmt:1p-v00 proc time (sec) mean: 0.1045 +/- 0.0154 rms: 0.0555 +/- 0.0109
hostname:sdfmilan216 rank:079 cpu:118 cmt:1p-v00 proc time (sec) mean: 0.1002 +/- 0.0135 rms: 0.0533 +/- 0.0095
mean time (sec): 0.0846

single core timing

mpirun -n 1 python Detector/examples/test-scaling-mpi.py 2

80-core timing

mpirun -n 80 python Detector/examples/test-scaling-mpi.py 2

Summary

time per event per core

  • single core: 43 ms
  • 80-core: 84 ms

2024-02-20 jungfrau single panel timing in real data

Description

Use local version of calib_jungfrau with timing points:

code of local version of calib_jungfrau with timing points
def calib_jungfrau(det, evt, cmpars=(7,3,200,10), **kwa):
    """
    Returns calibrated jungfrau data

    - gets constants
    - gets raw data
    - evaluates (code - pedestal - offset)
    - applys common mode correction if turned on
    - apply gain factor

    Parameters

    - det (psana.Detector) - Detector object
    - evt (psana.Event)    - Event object
    - cmpars (tuple) - common mode parameters
        - cmpars[0] - algorithm # 7-for jungfrau
        - cmpars[1] - control bit-word 1-in rows, 2-in columns
        - cmpars[2] - maximal applied correction
    - **kwa - used here and passed to det.mask_v2 or det.mask_comb
      - nda_raw - if not None, substitutes evt.raw()
      - mbits - DEPRECATED parameter of the det.mask_comb(...)
      - mask - user defined mask passed as optional parameter
    """

    t00 = time()

    src = det.source # - src (psana.Source)   - Source object

    nda_raw = kwa.get('nda_raw', None)
    arr = det.raw(evt) if nda_raw is None else nda_raw # shape:(<npanels>, 512, 1024) dtype:uint16
    if arr is None: return None

    t01 = time()

    peds = det.pedestals(evt) # - 4d pedestals shape:(3, 1, 512, 1024) dtype:float32
    if peds is None: return None

    t02 = time()

    gain = det.gain(evt)      # - 4d gains
    offs = det.offset(evt)    # - 4d offset

    t03 = time()

    detname = string_from_source(det.source)
    cmp = det.common_mode(evt) if cmpars is None else cmpars

    t04 = time()

    if gain is None: gain = np.ones_like(peds)  # - 4d gains
    if offs is None: offs = np.zeros_like(peds) # - 4d gains

    #print(info_ndarr(peds, 'peds'))
    #print(info_ndarr(gain, 'gain'))
    #print(info_ndarr(offs, 'offs'))

    # cache
    gfac = store.gfac.get(detname, None) # det.name
    if gfac is None:
       gfac = divide_protected(np.ones_like(peds), gain)
       store.gfac[detname] = gfac
       store.arr1 = np.ones_like(arr, dtype=np.int8)

    t05 = time()

    # Define bool arrays of ranges
    # faster than bit operations
    gr0 = arr <  BW1              # 490 us
    gr1 =(arr >= BW1) & (arr<BW2) # 714 us
    gr2 = arr >= BW3              # 400 us

    t06 = time()

    # Subtract pedestals
    arrf = np.array(arr & MSK, dtype=np.float32)

    t07 = time()

    arrf[gr0] -= peds[0,gr0]
    arrf[gr1] -= peds[1,gr1] #- arrf[gr1]
    arrf[gr2] -= peds[2,gr2] #- arrf[gr2]

    t08 = time()

    factor = np.select((gr0, gr1, gr2), (gfac[0,:], gfac[1,:], gfac[2,:]), default=1) # 2msec

    t09 = time()

    offset = np.select((gr0, gr1, gr2), (offs[0,:], offs[1,:], offs[2,:]), default=0)

    t10 = time()

    arrf -= offset # Apply offset correction

    t11 = time()
    #print('   time to subtract offset(sec): %.06f' % (t11-t10)) # ~< 100us

    if store.mask is None:
       store.mask = det.mask_total(evt, **kwa)
    mask = store.mask

    t12 = time()

    if cmp is not None:
      mode, cormax = int(cmp[1]), cmp[2]
      npixmin = cmp[3] if len(cmp)>3 else 10
      if mode>0:
        #arr1 = store.arr1
        #grhg = np.select((gr0,  gr1), (arr1, arr1), default=0)
        logger.debug(info_ndarr(gr0, 'gain group0'))
        logger.debug(info_ndarr(mask, 'mask'))
        t0_sec_cm = time()
        gmask = np.bitwise_and(gr0, mask) if mask is not None else gr0
        #sh = (nsegs, 512, 1024)
        hrows = 256 #512/2
        for s in range(arrf.shape[0]):
          if mode & 4: # in banks: (512/2,1024/16) = (256,64) pixels # 100 ms
            common_mode_2d_hsplit_nbanks(arrf[s,:hrows,:], mask=gmask[s,:hrows,:], nbanks=16, cormax=cormax, npix_min=npixmin)
            common_mode_2d_hsplit_nbanks(arrf[s,hrows:,:], mask=gmask[s,hrows:,:], nbanks=16, cormax=cormax, npix_min=npixmin)

          if mode & 1: # in rows per bank: 1024/16 = 64 pixels # 275 ms
            common_mode_rows_hsplit_nbanks(arrf[s,], mask=gmask[s,], nbanks=16, cormax=cormax, npix_min=npixmin)

          if mode & 2: # in cols per bank: 512/2 = 256 pixels  # 290 ms
            common_mode_cols(arrf[s,:hrows,:], mask=gmask[s,:hrows,:], cormax=cormax, npix_min=npixmin)
            common_mode_cols(arrf[s,hrows:,:], mask=gmask[s,hrows:,:], cormax=cormax, npix_min=npixmin)

        logger.debug('TIME: common-mode correction time = %.6f sec' % (time()-t0_sec_cm))

    t13 = time()

    resp = arrf * factor if mask is None else arrf * factor * mask # gain correction

    t14 = time()
    times = np.array((t00, t01, t02, t03, t04, t05, t06, t07, t08, t09, t10, t11, t12, t13, t14), dtype=np.float64)

    return resp, times

Results

local calib_jungfrau - timing results for single core and 80-code mpi processing
single-core processing
======================

mpirun -n 1 python Detector/examples/test-scaling-mpi.py 2
figs/fig-mpi-data-1p-v2-sdfmilan216-ncores01-summary.txt:
hostname:sdfmilan216 rank:000 cpu:000 cmt:1p-v2 proc time (sec) mean: 0.0427 +/- 0.0010 rms: 0.0011 +/- 0.0007
hostname:sdfmilan216 rank:000 cpu:000 cmt:1p-v2 proc time (sec) mean: 0.0428 +/- 0.0011 rms: 0.0012 +/- 0.0008
hostname:sdfmilan216 rank:000 cpu:000 cmt:1p-v2 proc time (sec) mean: 0.0428 +/- 0.0014 rms: 0.0015 +/- 0.0010
hostname:sdfmilan216 rank:000 cpu:000 cmt:1p-v2 proc time (sec) mean: 0.0427 +/- 0.0010 rms: 0.0011 +/- 0.0007

 
80-core processing
==================

mpirun -n 80 python Detector/examples/test-scaling-mpi.py 2
python Detector/examples/test-scaling-mpi.py -99
figs/fig-mpi-data-1p-v02-sdfmilan216-ncores80-summary-ordered.txt:
hostname:sdfmilan216 rank:000 cpu:007 cmt:1p-v2 proc time (sec) mean: 0.1041 +/- 0.0114 rms: 0.0480 +/- 0.0080
hostname:sdfmilan216 rank:001 cpu:027 cmt:1p-v2 proc time (sec) mean: 0.0775 +/- 0.0058 rms: 0.0192 +/- 0.0041
hostname:sdfmilan216 rank:002 cpu:042 cmt:1p-v2 proc time (sec) mean: 0.0692 +/- 0.0048 rms: 0.0123 +/- 0.0034
hostname:sdfmilan216 rank:003 cpu:054 cmt:1p-v2 proc time (sec) mean: 0.0516 +/- 0.0020 rms: 0.0028 +/- 0.0014
hostname:sdfmilan216 rank:004 cpu:069 cmt:1p-v2 proc time (sec) mean: 0.1066 +/- 0.0100 rms: 0.0432 +/- 0.0071
hostname:sdfmilan216 rank:005 cpu:086 cmt:1p-v2 proc time (sec) mean: 0.0974 +/- 0.0076 rms: 0.0309 +/- 0.0054
hostname:sdfmilan216 rank:006 cpu:100 cmt:1p-v2 proc time (sec) mean: 0.1153 +/- 0.0363 rms: 0.1002 +/- 0.0257
hostname:sdfmilan216 rank:007 cpu:122 cmt:1p-v2 proc time (sec) mean: 0.1206 +/- 0.0205 rms: 0.0796 +/- 0.0145
hostname:sdfmilan216 rank:008 cpu:009 cmt:1p-v2 proc time (sec) mean: 0.1003 +/- 0.0107 rms: 0.0457 +/- 0.0076
hostname:sdfmilan216 rank:009 cpu:028 cmt:1p-v2 proc time (sec) mean: 0.0759 +/- 0.0064 rms: 0.0188 +/- 0.0045
hostname:sdfmilan216 rank:010 cpu:041 cmt:1p-v2 proc time (sec) mean: 0.0680 +/- 0.0057 rms: 0.0137 +/- 0.0040
hostname:sdfmilan216 rank:011 cpu:060 cmt:1p-v2 proc time (sec) mean: 0.0527 +/- 0.0020 rms: 0.0028 +/- 0.0014
hostname:sdfmilan216 rank:012 cpu:076 cmt:1p-v2 proc time (sec) mean: 0.1057 +/- 0.0097 rms: 0.0433 +/- 0.0069
hostname:sdfmilan216 rank:013 cpu:082 cmt:1p-v2 proc time (sec) mean: 0.0901 +/- 0.0070 rms: 0.0272 +/- 0.0050
hostname:sdfmilan216 rank:014 cpu:106 cmt:1p-v2 proc time (sec) mean: 0.1058 +/- 0.0227 rms: 0.0702 +/- 0.0161
hostname:sdfmilan216 rank:015 cpu:120 cmt:1p-v2 proc time (sec) mean: 0.1235 +/- 0.0215 rms: 0.0813 +/- 0.0152
hostname:sdfmilan216 rank:016 cpu:004 cmt:1p-v2 proc time (sec) mean: 0.1057 +/- 0.0119 rms: 0.0499 +/- 0.0084
hostname:sdfmilan216 rank:017 cpu:025 cmt:1p-v2 proc time (sec) mean: 0.0779 +/- 0.0063 rms: 0.0204 +/- 0.0045
hostname:sdfmilan216 rank:018 cpu:039 cmt:1p-v2 proc time (sec) mean: 0.0676 +/- 0.0054 rms: 0.0126 +/- 0.0038
hostname:sdfmilan216 rank:019 cpu:049 cmt:1p-v2 proc time (sec) mean: 0.0520 +/- 0.0019 rms: 0.0025 +/- 0.0014
hostname:sdfmilan216 rank:020 cpu:075 cmt:1p-v2 proc time (sec) mean: 0.1052 +/- 0.0098 rms: 0.0408 +/- 0.0069
hostname:sdfmilan216 rank:021 cpu:094 cmt:1p-v2 proc time (sec) mean: 0.0900 +/- 0.0068 rms: 0.0268 +/- 0.0048
hostname:sdfmilan216 rank:022 cpu:108 cmt:1p-v2 proc time (sec) mean: 0.1113 +/- 0.0193 rms: 0.0703 +/- 0.0136
hostname:sdfmilan216 rank:023 cpu:124 cmt:1p-v2 proc time (sec) mean: 0.1199 +/- 0.0197 rms: 0.0774 +/- 0.0140
hostname:sdfmilan216 rank:024 cpu:014 cmt:1p-v2 proc time (sec) mean: 0.1060 +/- 0.0104 rms: 0.0457 +/- 0.0073
hostname:sdfmilan216 rank:025 cpu:028 cmt:1p-v2 proc time (sec) mean: 0.0747 +/- 0.0054 rms: 0.0173 +/- 0.0038
hostname:sdfmilan216 rank:026 cpu:036 cmt:1p-v2 proc time (sec) mean: 0.0694 +/- 0.0051 rms: 0.0135 +/- 0.0036
hostname:sdfmilan216 rank:027 cpu:055 cmt:1p-v2 proc time (sec) mean: 0.0523 +/- 0.0020 rms: 0.0026 +/- 0.0014
hostname:sdfmilan216 rank:028 cpu:066 cmt:1p-v2 proc time (sec) mean: 0.1039 +/- 0.0093 rms: 0.0396 +/- 0.0066
hostname:sdfmilan216 rank:029 cpu:092 cmt:1p-v2 proc time (sec) mean: 0.0914 +/- 0.0061 rms: 0.0231 +/- 0.0043
hostname:sdfmilan216 rank:030 cpu:097 cmt:1p-v2 proc time (sec) mean: 0.1175 +/- 0.0258 rms: 0.0805 +/- 0.0183
hostname:sdfmilan216 rank:031 cpu:113 cmt:1p-v2 proc time (sec) mean: 0.1162 +/- 0.0171 rms: 0.0704 +/- 0.0121
hostname:sdfmilan216 rank:032 cpu:001 cmt:1p-v2 proc time (sec) mean: 0.1041 +/- 0.0120 rms: 0.0500 +/- 0.0085
hostname:sdfmilan216 rank:033 cpu:031 cmt:1p-v2 proc time (sec) mean: 0.0792 +/- 0.0065 rms: 0.0212 +/- 0.0046
hostname:sdfmilan216 rank:034 cpu:038 cmt:1p-v2 proc time (sec) mean: 0.0692 +/- 0.0052 rms: 0.0132 +/- 0.0037
hostname:sdfmilan216 rank:035 cpu:050 cmt:1p-v2 proc time (sec) mean: 0.0527 +/- 0.0021 rms: 0.0031 +/- 0.0015
hostname:sdfmilan216 rank:036 cpu:072 cmt:1p-v2 proc time (sec) mean: 0.1025 +/- 0.0100 rms: 0.0420 +/- 0.0070
hostname:sdfmilan216 rank:037 cpu:095 cmt:1p-v2 proc time (sec) mean: 0.0945 +/- 0.0067 rms: 0.0272 +/- 0.0047
hostname:sdfmilan216 rank:038 cpu:110 cmt:1p-v2 proc time (sec) mean: 0.1074 +/- 0.0191 rms: 0.0660 +/- 0.0135
hostname:sdfmilan216 rank:039 cpu:119 cmt:1p-v2 proc time (sec) mean: 0.1095 +/- 0.0190 rms: 0.0714 +/- 0.0134
hostname:sdfmilan216 rank:040 cpu:011 cmt:1p-v2 proc time (sec) mean: 0.1043 +/- 0.0102 rms: 0.0453 +/- 0.0072
hostname:sdfmilan216 rank:041 cpu:029 cmt:1p-v2 proc time (sec) mean: 0.0768 +/- 0.0063 rms: 0.0199 +/- 0.0044
hostname:sdfmilan216 rank:042 cpu:037 cmt:1p-v2 proc time (sec) mean: 0.0683 +/- 0.0050 rms: 0.0119 +/- 0.0035
hostname:sdfmilan216 rank:043 cpu:058 cmt:1p-v2 proc time (sec) mean: 0.0523 +/- 0.0021 rms: 0.0029 +/- 0.0015
hostname:sdfmilan216 rank:044 cpu:070 cmt:1p-v2 proc time (sec) mean: 0.1074 +/- 0.0117 rms: 0.0471 +/- 0.0083
hostname:sdfmilan216 rank:045 cpu:087 cmt:1p-v2 proc time (sec) mean: 0.0907 +/- 0.0068 rms: 0.0261 +/- 0.0048
hostname:sdfmilan216 rank:046 cpu:107 cmt:1p-v2 proc time (sec) mean: 0.1116 +/- 0.0225 rms: 0.0752 +/- 0.0159
hostname:sdfmilan216 rank:047 cpu:125 cmt:1p-v2 proc time (sec) mean: 0.1165 +/- 0.0220 rms: 0.0799 +/- 0.0155
hostname:sdfmilan216 rank:048 cpu:013 cmt:1p-v2 proc time (sec) mean: 0.1087 +/- 0.0104 rms: 0.0462 +/- 0.0073
hostname:sdfmilan216 rank:049 cpu:030 cmt:1p-v2 proc time (sec) mean: 0.0776 +/- 0.0063 rms: 0.0199 +/- 0.0045
hostname:sdfmilan216 rank:050 cpu:035 cmt:1p-v2 proc time (sec) mean: 0.0680 +/- 0.0049 rms: 0.0119 +/- 0.0035
hostname:sdfmilan216 rank:051 cpu:061 cmt:1p-v2 proc time (sec) mean: 0.0526 +/- 0.0020 rms: 0.0028 +/- 0.0014
hostname:sdfmilan216 rank:052 cpu:074 cmt:1p-v2 proc time (sec) mean: 0.1010 +/- 0.0103 rms: 0.0405 +/- 0.0073
hostname:sdfmilan216 rank:053 cpu:089 cmt:1p-v2 proc time (sec) mean: 0.0953 +/- 0.0070 rms: 0.0288 +/- 0.0049
hostname:sdfmilan216 rank:054 cpu:104 cmt:1p-v2 proc time (sec) mean: 0.1162 +/- 0.0385 rms: 0.1044 +/- 0.0272
hostname:sdfmilan216 rank:055 cpu:121 cmt:1p-v2 proc time (sec) mean: 0.1134 +/- 0.0249 rms: 0.0804 +/- 0.0176
hostname:sdfmilan216 rank:056 cpu:005 cmt:1p-v2 proc time (sec) mean: 0.1029 +/- 0.0114 rms: 0.0490 +/- 0.0081
hostname:sdfmilan216 rank:057 cpu:028 cmt:1p-v2 proc time (sec) mean: 0.0747 +/- 0.0059 rms: 0.0176 +/- 0.0042
hostname:sdfmilan216 rank:058 cpu:039 cmt:1p-v2 proc time (sec) mean: 0.0679 +/- 0.0051 rms: 0.0124 +/- 0.0036
hostname:sdfmilan216 rank:059 cpu:052 cmt:1p-v2 proc time (sec) mean: 0.0520 +/- 0.0020 rms: 0.0027 +/- 0.0014
hostname:sdfmilan216 rank:060 cpu:072 cmt:1p-v2 proc time (sec) mean: 0.1065 +/- 0.0113 rms: 0.0461 +/- 0.0080
hostname:sdfmilan216 rank:061 cpu:081 cmt:1p-v2 proc time (sec) mean: 0.0913 +/- 0.0071 rms: 0.0281 +/- 0.0050
hostname:sdfmilan216 rank:062 cpu:105 cmt:1p-v2 proc time (sec) mean: 0.1148 +/- 0.0327 rms: 0.0935 +/- 0.0231
hostname:sdfmilan216 rank:063 cpu:116 cmt:1p-v2 proc time (sec) mean: 0.1075 +/- 0.0161 rms: 0.0647 +/- 0.0114
hostname:sdfmilan216 rank:064 cpu:006 cmt:1p-v2 proc time (sec) mean: 0.1062 +/- 0.0110 rms: 0.0480 +/- 0.0078
hostname:sdfmilan216 rank:065 cpu:046 cmt:1p-v2 proc time (sec) mean: 0.0681 +/- 0.0052 rms: 0.0125 +/- 0.0037
hostname:sdfmilan216 rank:066 cpu:040 cmt:1p-v2 proc time (sec) mean: 0.0692 +/- 0.0055 rms: 0.0143 +/- 0.0039
hostname:sdfmilan216 rank:067 cpu:063 cmt:1p-v2 proc time (sec) mean: 0.0525 +/- 0.0021 rms: 0.0030 +/- 0.0015
hostname:sdfmilan216 rank:068 cpu:071 cmt:1p-v2 proc time (sec) mean: 0.1087 +/- 0.0116 rms: 0.0486 +/- 0.0082
hostname:sdfmilan216 rank:069 cpu:090 cmt:1p-v2 proc time (sec) mean: 0.0975 +/- 0.0068 rms: 0.0286 +/- 0.0048
hostname:sdfmilan216 rank:070 cpu:102 cmt:1p-v2 proc time (sec) mean: 0.1169 +/- 0.0312 rms: 0.0952 +/- 0.0221
hostname:sdfmilan216 rank:071 cpu:118 cmt:1p-v2 proc time (sec) mean: 0.1113 +/- 0.0191 rms: 0.0697 +/- 0.0135
hostname:sdfmilan216 rank:072 cpu:008 cmt:1p-v2 proc time (sec) mean: 0.1047 +/- 0.0105 rms: 0.0455 +/- 0.0074
hostname:sdfmilan216 rank:073 cpu:040 cmt:1p-v2 proc time (sec) mean: 0.0684 +/- 0.0053 rms: 0.0131 +/- 0.0038
hostname:sdfmilan216 rank:074 cpu:043 cmt:1p-v2 proc time (sec) mean: 0.0684 +/- 0.0051 rms: 0.0122 +/- 0.0036
hostname:sdfmilan216 rank:075 cpu:050 cmt:1p-v2 proc time (sec) mean: 0.0531 +/- 0.0020 rms: 0.0029 +/- 0.0014
hostname:sdfmilan216 rank:076 cpu:077 cmt:1p-v2 proc time (sec) mean: 0.1007 +/- 0.0091 rms: 0.0381 +/- 0.0065
hostname:sdfmilan216 rank:077 cpu:083 cmt:1p-v2 proc time (sec) mean: 0.0909 +/- 0.0078 rms: 0.0273 +/- 0.0055
hostname:sdfmilan216 rank:078 cpu:105 cmt:1p-v2 proc time (sec) mean: 0.1118 +/- 0.0241 rms: 0.0763 +/- 0.0170
hostname:sdfmilan216 rank:079 cpu:114 cmt:1p-v2 proc time (sec) mean: 0.1148 +/- 0.0229 rms: 0.0815 +/- 0.0162
mean time (sec): 0.0908

Summary

det.calib fir fungfrau already uses float32

time per event per core

  • single core: 43 ms
  • 80-core: 91 ms

2024-02-21 jungfrau single panel fraction in random

Description

Test is performed for single jungfrau panel of shape (512,1024) and its fractions 1/2, 1/4, 1/8, 2, 4  of shapes (256,1024), (128,1024), (64,1024), (2*512,1024), (4*512,1024), respectively

code of time consuming algorithm and random array generator equivalent to det.calib_jungfrau
#def random_arrays(sh2d = (512,1024), dtype=np.float32): # v1.000
#def random_arrays(sh2d = (256,1024), dtype=np.float32): # v1o2
#def random_arrays(sh2d = (128,1024), dtype=np.float32): # v1o4
def random_arrays(sh2d = (64,1024), dtype=np.float32): # v1o8
    """returns simulated det.raw, pedestals, gain, offset, mask, gfac, factor1, offset1, out
     raw shape:(1, 512, 1024) size:524288 dtype:uint16 [2734 2664 2675 2651 2633...]
     peds shape:(3, 1, 512, 1024) size:1572864 dtype:float32 [2723.69  2668.95
     gain shape:(3, 1, 512, 1024) size:1572864 dtype:float32 [36.8558 37.24   36.5578 36.7929 36.1728...]
     offs shape:(3, 1, 512, 1024) size:1572864 dtype:float32 [0. 0. 0. 0. 0....]
     gfac shape:(3, 1, 512, 1024) size:1572864 dtype:float32 [0.02713277 0.02685284 0.02735394 0.02717916 0.02764508...]
     arrf shape:(1, 512, 1024) size:524288 dtype:float32 [ 6.7856445
     factor shape:(1, 512, 1024) size:524288 dtype:float32 [0.02713277 0.02685284
     offset shape:(1, 512, 1024) size:524288 dtype:float32 [0. 0. 0.
     mask shape:(1, 512, 1024) size:524288 dtype:uint8 [1 1 1 1 1...]
     resp shape:(1, 512, 1024) size:524288 dtype:float32 [0.18411334 0.12152617 0.08894039 0.11908797 0.5094565 ...]
    """
    sh3d = (3,) + sh2d
    raw  = random_standard(shape=sh2d, mu=2650, sigma=20, dtype=np.uint16)
    peds = random_standard(shape=sh3d, mu=2650, sigma=20, dtype=dtype)
    gain = random_standard(shape=sh3d, mu=36.5, sigma=0.1, dtype=dtype)
    offs = random_standard(shape=sh3d, mu=0.5, sigma=0.1, dtype=dtype)
    gfac = random_standard(shape=sh3d, mu=0.027, sigma=0.002, dtype=dtype)
    arrf = random_standard(shape=sh2d, mu=6.75, sigma=0.3, dtype=dtype)
    factor = random_standard(shape=sh2d, mu=0.027, sigma=0.002, dtype=dtype)
    offs = random_standard(shape=sh2d, mu=0.5, sigma=0.1, dtype=dtype)
    mask = np.ones_like(raw, dtype=np.uint8)
    resp = random_standard(shape=sh2d, mu=0.2, sigma=0.01, dtype=dtype)
    return arrf, peds, gain, offs, gfac, raw, factor, offs, mask, resp


def time_consuming_algorithm():
    a, b, _, _, _, _, _, _, _, _ = random_arrays()
    t0_sec = time()
    gr1 = a>=7.1
    gr2 = (a>6.5) & (a<7.1)
    gr3 = a<=6.5
    a[gr1] -= b[0, gr1]
    a[gr2] -= b[1, gr2]
    a[gr3] -= b[2, gr3]
    return time() - t0_sec

Results

single-core processing

results for single coe processing
mpirun -n 1 python  Detector/examples/test-scaling-mpi.py 1
fig-mpi-rand-v1.000-sdfmilan216-ncores01-summary.txt
hostname:sdfmilan216 rank:000 cpu:000 cmt:v1.000 proc time (sec) mean: 0.0184 +/- 0.0004 rms: 0.0005 +/- 0.0003
hostname:sdfmilan216 rank:000 cpu:000 cmt:v1.000 proc time (sec) mean: 0.0186 +/- 0.0004 rms: 0.0004 +/- 0.0003

fig-mpi-rand-v1o2-sdfmilan216-ncores01-summary.txt
hostname:sdfmilan216 rank:000 cpu:000 cmt:v1o2 proc time (sec) mean: 0.0095 +/- 0.0001 rms: 0.0001 +/- 0.0001
hostname:sdfmilan216 rank:000 cpu:000 cmt:v1o2 proc time (sec) mean: 0.0090 +/- 0.0002 rms: 0.0004 +/- 0.0001
hostname:sdfmilan216 rank:000 cpu:000 cmt:v1o2 proc time (sec) mean: 0.0088 +/- 0.0002 rms: 0.0005 +/- 0.0001

fig-mpi-rand-v1o4-sdfmilan216-ncores01-summary.txt
hostname:sdfmilan216 rank:000 cpu:000 cmt:v1o4 proc time (sec) mean: 0.0045 +/- 0.0001 rms: 0.0003 +/- 0.0001
hostname:sdfmilan216 rank:000 cpu:000 cmt:v1o4 proc time (sec) mean: 0.0044 +/- 0.0002 rms: 0.0004 +/- 0.0001

fig-mpi-rand-v1o8-sdfmilan216-ncores01-summary.txt
hostname:sdfmilan216 rank:000 cpu:000 cmt:v1o8 proc time (sec) mean: 0.0022 +/- 0.0001 rms: 0.0002 +/- 0.0001
hostname:sdfmilan216 rank:000 cpu:000 cmt:v1o8 proc time (sec) mean: 0.0023 +/- 0.0001 rms: 0.0001 +/- 0.0001
hostname:sdfmilan216 rank:000 cpu:000 cmt:v1o8 proc time (sec) mean: 0.0023 +/- 0.0001 rms: 0.0001 +/- 0.0001
hostname:sdfmilan216 rank:000 cpu:000 cmt:v1o8 proc time (sec) mean: 0.0023 +/- 0.0001 rms: 0.0002 +/- 0.0001

fig-mpi-rand-v2o1-sdfmilan216-ncores01-summary.txt
hostname:sdfmilan216 rank:000 cpu:000 cmt:v2o1 proc time (sec) mean: 0.0373 +/- 0.0005 rms: 0.0009 +/- 0.0003

fig-mpi-rand-v4o1-sdfmilan216-ncores01-summary.txt
hostname:sdfmilan216 rank:000 cpu:000 cmt:v4o1 proc time (sec) mean: 0.0738 +/- 0.0019 rms: 0.0026 +/- 0.0013

80-core processing

results for 80-core processing
sys.argv: ['Detector/examples/test-scaling-mpi.py', '-99']
selector for mode: -99



sort_records_in_file: figs/fig-mpi-rand-v1.000-sdfmilan216-ncores80-summary.txt
records:
means: shape:(80,) size:80 dtype:float64
[0.0526 0.0278 0.0288 0.0207 0.0483 0.0466 0.0533 0.0551 0.0553 0.027
 0.0284 0.0208 0.0436 0.0445 0.0588 0.0624 0.0504 0.0269 0.0283 0.0206
 0.0462 0.0453 0.0548 0.0568 0.0561 0.0284 0.0284 0.0206 0.0462 0.0472
 0.0552 0.0563 0.0522 0.0265 0.028  0.0207 0.0477 0.0441 0.0566 0.0576
 0.0541 0.0284 0.0281 0.0206 0.0461 0.049  0.0512 0.0587 0.054  0.0275
 0.0285 0.0206 0.0469 0.05   0.0594 0.0568 0.0559 0.0288 0.0279 0.0207
 0.0511 0.0449 0.0669 0.0519 0.0532 0.0276 0.0286 0.0207 0.0477 0.0508
 0.0602 0.0522 0.0548 0.0284 0.028  0.0206 0.0445 0.0461 0.0574 0.0588]
mean time (sec): 0.0423

hostname:sdfmilan216 rank:000 cpu:007 cmt:v1.000 proc time (sec) mean: 0.0526 +/- 0.0071 rms: 0.0343 +/- 0.0050
hostname:sdfmilan216 rank:001 cpu:026 cmt:v1.000 proc time (sec) mean: 0.0278 +/- 0.0013 rms: 0.0050 +/- 0.0009
hostname:sdfmilan216 rank:002 cpu:043 cmt:v1.000 proc time (sec) mean: 0.0288 +/- 0.0013 rms: 0.0049 +/- 0.0009
hostname:sdfmilan216 rank:003 cpu:056 cmt:v1.000 proc time (sec) mean: 0.0207 +/- 0.0003 rms: 0.0004 +/- 0.0002
hostname:sdfmilan216 rank:004 cpu:065 cmt:v1.000 proc time (sec) mean: 0.0483 +/- 0.0050 rms: 0.0253 +/- 0.0035
hostname:sdfmilan216 rank:005 cpu:089 cmt:v1.000 proc time (sec) mean: 0.0466 +/- 0.0059 rms: 0.0262 +/- 0.0042
hostname:sdfmilan216 rank:006 cpu:110 cmt:v1.000 proc time (sec) mean: 0.0533 +/- 0.0138 rms: 0.0438 +/- 0.0098
hostname:sdfmilan216 rank:007 cpu:121 cmt:v1.000 proc time (sec) mean: 0.0551 +/- 0.0141 rms: 0.0461 +/- 0.0099
hostname:sdfmilan216 rank:008 cpu:005 cmt:v1.000 proc time (sec) mean: 0.0553 +/- 0.0079 rms: 0.0376 +/- 0.0056
hostname:sdfmilan216 rank:009 cpu:028 cmt:v1.000 proc time (sec) mean: 0.0270 +/- 0.0012 rms: 0.0042 +/- 0.0009
hostname:sdfmilan216 rank:010 cpu:045 cmt:v1.000 proc time (sec) mean: 0.0284 +/- 0.0012 rms: 0.0041 +/- 0.0008
hostname:sdfmilan216 rank:011 cpu:050 cmt:v1.000 proc time (sec) mean: 0.0208 +/- 0.0004 rms: 0.0005 +/- 0.0003
hostname:sdfmilan216 rank:012 cpu:068 cmt:v1.000 proc time (sec) mean: 0.0436 +/- 0.0048 rms: 0.0227 +/- 0.0034
hostname:sdfmilan216 rank:013 cpu:081 cmt:v1.000 proc time (sec) mean: 0.0445 +/- 0.0048 rms: 0.0238 +/- 0.0034
hostname:sdfmilan216 rank:014 cpu:111 cmt:v1.000 proc time (sec) mean: 0.0588 +/- 0.0154 rms: 0.0507 +/- 0.0109
hostname:sdfmilan216 rank:015 cpu:123 cmt:v1.000 proc time (sec) mean: 0.0624 +/- 0.0165 rms: 0.0554 +/- 0.0117
hostname:sdfmilan216 rank:016 cpu:014 cmt:v1.000 proc time (sec) mean: 0.0504 +/- 0.0045 rms: 0.0259 +/- 0.0032
hostname:sdfmilan216 rank:017 cpu:025 cmt:v1.000 proc time (sec) mean: 0.0269 +/- 0.0012 rms: 0.0042 +/- 0.0009
hostname:sdfmilan216 rank:018 cpu:035 cmt:v1.000 proc time (sec) mean: 0.0283 +/- 0.0012 rms: 0.0040 +/- 0.0008
hostname:sdfmilan216 rank:019 cpu:061 cmt:v1.000 proc time (sec) mean: 0.0206 +/- 0.0004 rms: 0.0005 +/- 0.0003
hostname:sdfmilan216 rank:020 cpu:075 cmt:v1.000 proc time (sec) mean: 0.0462 +/- 0.0051 rms: 0.0257 +/- 0.0036
hostname:sdfmilan216 rank:021 cpu:086 cmt:v1.000 proc time (sec) mean: 0.0453 +/- 0.0052 rms: 0.0246 +/- 0.0037
hostname:sdfmilan216 rank:022 cpu:100 cmt:v1.000 proc time (sec) mean: 0.0548 +/- 0.0145 rms: 0.0474 +/- 0.0103
hostname:sdfmilan216 rank:023 cpu:117 cmt:v1.000 proc time (sec) mean: 0.0568 +/- 0.0167 rms: 0.0512 +/- 0.0118
hostname:sdfmilan216 rank:024 cpu:006 cmt:v1.000 proc time (sec) mean: 0.0561 +/- 0.0077 rms: 0.0375 +/- 0.0054
hostname:sdfmilan216 rank:025 cpu:029 cmt:v1.000 proc time (sec) mean: 0.0284 +/- 0.0014 rms: 0.0048 +/- 0.0010
hostname:sdfmilan216 rank:026 cpu:036 cmt:v1.000 proc time (sec) mean: 0.0284 +/- 0.0011 rms: 0.0039 +/- 0.0008
hostname:sdfmilan216 rank:027 cpu:063 cmt:v1.000 proc time (sec) mean: 0.0206 +/- 0.0004 rms: 0.0005 +/- 0.0003
hostname:sdfmilan216 rank:028 cpu:076 cmt:v1.000 proc time (sec) mean: 0.0462 +/- 0.0053 rms: 0.0261 +/- 0.0037
hostname:sdfmilan216 rank:029 cpu:084 cmt:v1.000 proc time (sec) mean: 0.0472 +/- 0.0057 rms: 0.0249 +/- 0.0040
hostname:sdfmilan216 rank:030 cpu:102 cmt:v1.000 proc time (sec) mean: 0.0552 +/- 0.0128 rms: 0.0446 +/- 0.0091
hostname:sdfmilan216 rank:031 cpu:124 cmt:v1.000 proc time (sec) mean: 0.0563 +/- 0.0154 rms: 0.0476 +/- 0.0109
hostname:sdfmilan216 rank:032 cpu:009 cmt:v1.000 proc time (sec) mean: 0.0522 +/- 0.0059 rms: 0.0316 +/- 0.0041
hostname:sdfmilan216 rank:033 cpu:031 cmt:v1.000 proc time (sec) mean: 0.0265 +/- 0.0012 rms: 0.0042 +/- 0.0009
hostname:sdfmilan216 rank:034 cpu:042 cmt:v1.000 proc time (sec) mean: 0.0280 +/- 0.0011 rms: 0.0039 +/- 0.0008
hostname:sdfmilan216 rank:035 cpu:051 cmt:v1.000 proc time (sec) mean: 0.0207 +/- 0.0004 rms: 0.0005 +/- 0.0003
hostname:sdfmilan216 rank:036 cpu:071 cmt:v1.000 proc time (sec) mean: 0.0477 +/- 0.0047 rms: 0.0253 +/- 0.0033
hostname:sdfmilan216 rank:037 cpu:083 cmt:v1.000 proc time (sec) mean: 0.0441 +/- 0.0046 rms: 0.0227 +/- 0.0033
hostname:sdfmilan216 rank:038 cpu:109 cmt:v1.000 proc time (sec) mean: 0.0566 +/- 0.0157 rms: 0.0492 +/- 0.0111
hostname:sdfmilan216 rank:039 cpu:112 cmt:v1.000 proc time (sec) mean: 0.0576 +/- 0.0168 rms: 0.0504 +/- 0.0119
hostname:sdfmilan216 rank:040 cpu:004 cmt:v1.000 proc time (sec) mean: 0.0541 +/- 0.0081 rms: 0.0377 +/- 0.0057
hostname:sdfmilan216 rank:041 cpu:024 cmt:v1.000 proc time (sec) mean: 0.0284 +/- 0.0013 rms: 0.0046 +/- 0.0009
hostname:sdfmilan216 rank:042 cpu:039 cmt:v1.000 proc time (sec) mean: 0.0281 +/- 0.0012 rms: 0.0045 +/- 0.0008
hostname:sdfmilan216 rank:043 cpu:058 cmt:v1.000 proc time (sec) mean: 0.0206 +/- 0.0004 rms: 0.0006 +/- 0.0003
hostname:sdfmilan216 rank:044 cpu:069 cmt:v1.000 proc time (sec) mean: 0.0461 +/- 0.0056 rms: 0.0259 +/- 0.0040
hostname:sdfmilan216 rank:045 cpu:092 cmt:v1.000 proc time (sec) mean: 0.0490 +/- 0.0056 rms: 0.0255 +/- 0.0040
hostname:sdfmilan216 rank:046 cpu:099 cmt:v1.000 proc time (sec) mean: 0.0512 +/- 0.0142 rms: 0.0429 +/- 0.0101
hostname:sdfmilan216 rank:047 cpu:118 cmt:v1.000 proc time (sec) mean: 0.0587 +/- 0.0163 rms: 0.0529 +/- 0.0115
hostname:sdfmilan216 rank:048 cpu:008 cmt:v1.000 proc time (sec) mean: 0.0540 +/- 0.0075 rms: 0.0360 +/- 0.0053
hostname:sdfmilan216 rank:049 cpu:030 cmt:v1.000 proc time (sec) mean: 0.0275 +/- 0.0013 rms: 0.0046 +/- 0.0009
hostname:sdfmilan216 rank:050 cpu:038 cmt:v1.000 proc time (sec) mean: 0.0285 +/- 0.0012 rms: 0.0045 +/- 0.0009
hostname:sdfmilan216 rank:051 cpu:057 cmt:v1.000 proc time (sec) mean: 0.0206 +/- 0.0004 rms: 0.0005 +/- 0.0003
hostname:sdfmilan216 rank:052 cpu:066 cmt:v1.000 proc time (sec) mean: 0.0469 +/- 0.0051 rms: 0.0246 +/- 0.0036
hostname:sdfmilan216 rank:053 cpu:095 cmt:v1.000 proc time (sec) mean: 0.0500 +/- 0.0064 rms: 0.0283 +/- 0.0045
hostname:sdfmilan216 rank:054 cpu:101 cmt:v1.000 proc time (sec) mean: 0.0594 +/- 0.0177 rms: 0.0534 +/- 0.0125
hostname:sdfmilan216 rank:055 cpu:114 cmt:v1.000 proc time (sec) mean: 0.0568 +/- 0.0175 rms: 0.0516 +/- 0.0124
hostname:sdfmilan216 rank:056 cpu:015 cmt:v1.000 proc time (sec) mean: 0.0559 +/- 0.0067 rms: 0.0353 +/- 0.0047
hostname:sdfmilan216 rank:057 cpu:027 cmt:v1.000 proc time (sec) mean: 0.0288 +/- 0.0013 rms: 0.0048 +/- 0.0009
hostname:sdfmilan216 rank:058 cpu:047 cmt:v1.000 proc time (sec) mean: 0.0279 +/- 0.0012 rms: 0.0040 +/- 0.0008
hostname:sdfmilan216 rank:059 cpu:055 cmt:v1.000 proc time (sec) mean: 0.0207 +/- 0.0004 rms: 0.0005 +/- 0.0003
hostname:sdfmilan216 rank:060 cpu:064 cmt:v1.000 proc time (sec) mean: 0.0511 +/- 0.0067 rms: 0.0294 +/- 0.0048
hostname:sdfmilan216 rank:061 cpu:082 cmt:v1.000 proc time (sec) mean: 0.0449 +/- 0.0056 rms: 0.0241 +/- 0.0040
hostname:sdfmilan216 rank:062 cpu:106 cmt:v1.000 proc time (sec) mean: 0.0669 +/- 0.0186 rms: 0.0610 +/- 0.0132
hostname:sdfmilan216 rank:063 cpu:115 cmt:v1.000 proc time (sec) mean: 0.0519 +/- 0.0138 rms: 0.0440 +/- 0.0097
hostname:sdfmilan216 rank:064 cpu:008 cmt:v1.000 proc time (sec) mean: 0.0532 +/- 0.0064 rms: 0.0338 +/- 0.0045
hostname:sdfmilan216 rank:065 cpu:033 cmt:v1.000 proc time (sec) mean: 0.0276 +/- 0.0010 rms: 0.0035 +/- 0.0007
hostname:sdfmilan216 rank:066 cpu:044 cmt:v1.000 proc time (sec) mean: 0.0286 +/- 0.0012 rms: 0.0044 +/- 0.0009
hostname:sdfmilan216 rank:067 cpu:052 cmt:v1.000 proc time (sec) mean: 0.0207 +/- 0.0004 rms: 0.0005 +/- 0.0003
hostname:sdfmilan216 rank:068 cpu:077 cmt:v1.000 proc time (sec) mean: 0.0477 +/- 0.0050 rms: 0.0258 +/- 0.0035
hostname:sdfmilan216 rank:069 cpu:093 cmt:v1.000 proc time (sec) mean: 0.0508 +/- 0.0065 rms: 0.0291 +/- 0.0046
hostname:sdfmilan216 rank:070 cpu:096 cmt:v1.000 proc time (sec) mean: 0.0602 +/- 0.0186 rms: 0.0570 +/- 0.0131
hostname:sdfmilan216 rank:071 cpu:113 cmt:v1.000 proc time (sec) mean: 0.0522 +/- 0.0144 rms: 0.0456 +/- 0.0102
hostname:sdfmilan216 rank:072 cpu:013 cmt:v1.000 proc time (sec) mean: 0.0548 +/- 0.0067 rms: 0.0349 +/- 0.0048
hostname:sdfmilan216 rank:073 cpu:032 cmt:v1.000 proc time (sec) mean: 0.0284 +/- 0.0013 rms: 0.0049 +/- 0.0009
hostname:sdfmilan216 rank:074 cpu:046 cmt:v1.000 proc time (sec) mean: 0.0280 +/- 0.0012 rms: 0.0044 +/- 0.0009
hostname:sdfmilan216 rank:075 cpu:054 cmt:v1.000 proc time (sec) mean: 0.0206 +/- 0.0004 rms: 0.0005 +/- 0.0003
hostname:sdfmilan216 rank:076 cpu:074 cmt:v1.000 proc time (sec) mean: 0.0445 +/- 0.0047 rms: 0.0227 +/- 0.0033
hostname:sdfmilan216 rank:077 cpu:091 cmt:v1.000 proc time (sec) mean: 0.0461 +/- 0.0051 rms: 0.0241 +/- 0.0036
hostname:sdfmilan216 rank:078 cpu:105 cmt:v1.000 proc time (sec) mean: 0.0574 +/- 0.0155 rms: 0.0506 +/- 0.0110
hostname:sdfmilan216 rank:079 cpu:127 cmt:v1.000 proc time (sec) mean: 0.0588 +/- 0.0180 rms: 0.0530 +/- 0.0127
mean time (sec): 0.0423



sort_records_in_file: figs/fig-mpi-rand-v1o2-sdfmilan216-ncores80-summary.txt
records:
means: shape:(160,) size:160 dtype:float64
[0.0108 0.011  0.0108 0.0109 0.0108 0.0109 0.0105 0.0106 0.0105 0.0103
 0.0105 0.0103 0.0103 0.0105 0.0105 0.0103 0.0109 0.0109 0.0109 0.011
 0.0107 0.0108 0.0105 0.0105 0.0105 0.0102 0.0103 0.0105 0.0105 0.0104
 0.0105 0.0103 0.0109 0.0108 0.0109 0.0109 0.0108 0.0109 0.0105 0.0106
 0.0105 0.0102 0.0103 0.0105 0.0104 0.0105 0.0102 0.0105 0.011  0.0109
 0.0108 0.0109 0.0107 0.0109 0.0105 0.0106 0.0105 0.0103 0.0103 0.0105
 0.0106 0.0103 0.0103 0.0105 0.0109 0.0109 0.0107 0.0109 0.0109 0.0107
 0.0105 0.0106 0.0105 0.0102 0.0103 0.0106 0.0105 0.0103 0.0103 0.0105
 0.0109 0.011  0.0108 0.0109 0.0108 0.0109 0.0106 0.0105 0.0105 0.0103
 0.0106 0.0103 0.0103 0.0105 0.0102 0.0105 0.011  0.0109 0.0108 0.0109...]
mean time (sec): 0.0106

hostname:sdfmilan216 rank:000 cpu:002 cmt:v1o2 proc time (sec) mean: 0.0108 +/- 0.0005 rms: 0.0006 +/- 0.0003
hostname:sdfmilan216 rank:000 cpu:011 cmt:v1o2 proc time (sec) mean: 0.0110 +/- 0.0002 rms: 0.0004 +/- 0.0002
hostname:sdfmilan216 rank:001 cpu:025 cmt:v1o2 proc time (sec) mean: 0.0108 +/- 0.0002 rms: 0.0004 +/- 0.0001
hostname:sdfmilan216 rank:001 cpu:028 cmt:v1o2 proc time (sec) mean: 0.0109 +/- 0.0004 rms: 0.0005 +/- 0.0003
hostname:sdfmilan216 rank:002 cpu:034 cmt:v1o2 proc time (sec) mean: 0.0108 +/- 0.0003 rms: 0.0004 +/- 0.0002
hostname:sdfmilan216 rank:002 cpu:037 cmt:v1o2 proc time (sec) mean: 0.0109 +/- 0.0002 rms: 0.0003 +/- 0.0001
hostname:sdfmilan216 rank:003 cpu:054 cmt:v1o2 proc time (sec) mean: 0.0105 +/- 0.0002 rms: 0.0002 +/- 0.0001
hostname:sdfmilan216 rank:003 cpu:060 cmt:v1o2 proc time (sec) mean: 0.0106 +/- 0.0002 rms: 0.0002 +/- 0.0001
hostname:sdfmilan216 rank:004 cpu:068 cmt:v1o2 proc time (sec) mean: 0.0105 +/- 0.0000 rms: 0.0000 +/- 0.0000
hostname:sdfmilan216 rank:004 cpu:075 cmt:v1o2 proc time (sec) mean: 0.0103 +/- 0.0002 rms: 0.0003 +/- 0.0002
hostname:sdfmilan216 rank:005 cpu:085 cmt:v1o2 proc time (sec) mean: 0.0105 +/- 0.0002 rms: 0.0002 +/- 0.0002
hostname:sdfmilan216 rank:005 cpu:086 cmt:v1o2 proc time (sec) mean: 0.0103 +/- 0.0002 rms: 0.0002 +/- 0.0001
hostname:sdfmilan216 rank:006 cpu:107 cmt:v1o2 proc time (sec) mean: 0.0103 +/- 0.0002 rms: 0.0003 +/- 0.0001
hostname:sdfmilan216 rank:006 cpu:111 cmt:v1o2 proc time (sec) mean: 0.0105 +/- 0.0002 rms: 0.0002 +/- 0.0002
hostname:sdfmilan216 rank:007 cpu:120 cmt:v1o2 proc time (sec) mean: 0.0105 +/- 0.0001 rms: 0.0001 +/- 0.0001
hostname:sdfmilan216 rank:007 cpu:123 cmt:v1o2 proc time (sec) mean: 0.0103 +/- 0.0002 rms: 0.0002 +/- 0.0001
hostname:sdfmilan216 rank:008 cpu:006 cmt:v1o2 proc time (sec) mean: 0.0109 +/- 0.0005 rms: 0.0006 +/- 0.0003
hostname:sdfmilan216 rank:008 cpu:009 cmt:v1o2 proc time (sec) mean: 0.0109 +/- 0.0002 rms: 0.0003 +/- 0.0001
hostname:sdfmilan216 rank:009 cpu:027 cmt:v1o2 proc time (sec) mean: 0.0109 +/- 0.0002 rms: 0.0005 +/- 0.0002
hostname:sdfmilan216 rank:009 cpu:031 cmt:v1o2 proc time (sec) mean: 0.0110 +/- 0.0004 rms: 0.0006 +/- 0.0003
hostname:sdfmilan216 rank:010 cpu:043 cmt:v1o2 proc time (sec) mean: 0.0107 +/- 0.0004 rms: 0.0005 +/- 0.0003
hostname:sdfmilan216 rank:010 cpu:044 cmt:v1o2 proc time (sec) mean: 0.0108 +/- 0.0002 rms: 0.0003 +/- 0.0001
hostname:sdfmilan216 rank:011 cpu:050 cmt:v1o2 proc time (sec) mean: 0.0105 +/- 0.0001 rms: 0.0002 +/- 0.0001
hostname:sdfmilan216 rank:011 cpu:061 cmt:v1o2 proc time (sec) mean: 0.0105 +/- 0.0000 rms: 0.0000 +/- 0.0000
hostname:sdfmilan216 rank:012 cpu:069 cmt:v1o2 proc time (sec) mean: 0.0105 +/- 0.0002 rms: 0.0002 +/- 0.0001
hostname:sdfmilan216 rank:012 cpu:073 cmt:v1o2 proc time (sec) mean: 0.0102 +/- 0.0001 rms: 0.0002 +/- 0.0001
hostname:sdfmilan216 rank:013 cpu:084 cmt:v1o2 proc time (sec) mean: 0.0103 +/- 0.0002 rms: 0.0003 +/- 0.0001
hostname:sdfmilan216 rank:013 cpu:095 cmt:v1o2 proc time (sec) mean: 0.0105 +/- 0.0002 rms: 0.0002 +/- 0.0001
hostname:sdfmilan216 rank:014 cpu:108 cmt:v1o2 proc time (sec) mean: 0.0105 +/- 0.0002 rms: 0.0002 +/- 0.0001
hostname:sdfmilan216 rank:014 cpu:110 cmt:v1o2 proc time (sec) mean: 0.0104 +/- 0.0001 rms: 0.0002 +/- 0.0001
hostname:sdfmilan216 rank:015 cpu:124 cmt:v1o2 proc time (sec) mean: 0.0105 +/- 0.0001 rms: 0.0001 +/- 0.0001
hostname:sdfmilan216 rank:015 cpu:126 cmt:v1o2 proc time (sec) mean: 0.0103 +/- 0.0002 rms: 0.0003 +/- 0.0001
hostname:sdfmilan216 rank:016 cpu:007 cmt:v1o2 proc time (sec) mean: 0.0109 +/- 0.0004 rms: 0.0005 +/- 0.0003
hostname:sdfmilan216 rank:016 cpu:008 cmt:v1o2 proc time (sec) mean: 0.0108 +/- 0.0002 rms: 0.0003 +/- 0.0001
hostname:sdfmilan216 rank:017 cpu:027 cmt:v1o2 proc time (sec) mean: 0.0109 +/- 0.0004 rms: 0.0006 +/- 0.0003
hostname:sdfmilan216 rank:017 cpu:029 cmt:v1o2 proc time (sec) mean: 0.0109 +/- 0.0002 rms: 0.0004 +/- 0.0002
hostname:sdfmilan216 rank:018 cpu:039 cmt:v1o2 proc time (sec) mean: 0.0108 +/- 0.0004 rms: 0.0006 +/- 0.0003
hostname:sdfmilan216 rank:018 cpu:042 cmt:v1o2 proc time (sec) mean: 0.0109 +/- 0.0002 rms: 0.0004 +/- 0.0002
hostname:sdfmilan216 rank:019 cpu:052 cmt:v1o2 proc time (sec) mean: 0.0105 +/- 0.0000 rms: 0.0000 +/- 0.0000
hostname:sdfmilan216 rank:019 cpu:052 cmt:v1o2 proc time (sec) mean: 0.0106 +/- 0.0001 rms: 0.0002 +/- 0.0001
hostname:sdfmilan216 rank:020 cpu:073 cmt:v1o2 proc time (sec) mean: 0.0105 +/- 0.0002 rms: 0.0002 +/- 0.0001
hostname:sdfmilan216 rank:020 cpu:076 cmt:v1o2 proc time (sec) mean: 0.0102 +/- 0.0001 rms: 0.0002 +/- 0.0001
hostname:sdfmilan216 rank:021 cpu:080 cmt:v1o2 proc time (sec) mean: 0.0103 +/- 0.0002 rms: 0.0003 +/- 0.0001
hostname:sdfmilan216 rank:021 cpu:086 cmt:v1o2 proc time (sec) mean: 0.0105 +/- 0.0001 rms: 0.0001 +/- 0.0001
hostname:sdfmilan216 rank:022 cpu:097 cmt:v1o2 proc time (sec) mean: 0.0104 +/- 0.0001 rms: 0.0002 +/- 0.0001
hostname:sdfmilan216 rank:022 cpu:097 cmt:v1o2 proc time (sec) mean: 0.0105 +/- 0.0002 rms: 0.0002 +/- 0.0001
hostname:sdfmilan216 rank:023 cpu:113 cmt:v1o2 proc time (sec) mean: 0.0102 +/- 0.0002 rms: 0.0003 +/- 0.0001
hostname:sdfmilan216 rank:023 cpu:119 cmt:v1o2 proc time (sec) mean: 0.0105 +/- 0.0002 rms: 0.0002 +/- 0.0001
hostname:sdfmilan216 rank:024 cpu:002 cmt:v1o2 proc time (sec) mean: 0.0110 +/- 0.0002 rms: 0.0004 +/- 0.0001
hostname:sdfmilan216 rank:024 cpu:003 cmt:v1o2 proc time (sec) mean: 0.0109 +/- 0.0004 rms: 0.0006 +/- 0.0003
hostname:sdfmilan216 rank:025 cpu:024 cmt:v1o2 proc time (sec) mean: 0.0108 +/- 0.0002 rms: 0.0004 +/- 0.0001
hostname:sdfmilan216 rank:025 cpu:026 cmt:v1o2 proc time (sec) mean: 0.0109 +/- 0.0004 rms: 0.0006 +/- 0.0003
hostname:sdfmilan216 rank:026 cpu:036 cmt:v1o2 proc time (sec) mean: 0.0107 +/- 0.0003 rms: 0.0004 +/- 0.0002
hostname:sdfmilan216 rank:026 cpu:047 cmt:v1o2 proc time (sec) mean: 0.0109 +/- 0.0002 rms: 0.0004 +/- 0.0001
hostname:sdfmilan216 rank:027 cpu:051 cmt:v1o2 proc time (sec) mean: 0.0105 +/- 0.0001 rms: 0.0001 +/- 0.0001
hostname:sdfmilan216 rank:027 cpu:051 cmt:v1o2 proc time (sec) mean: 0.0106 +/- 0.0001 rms: 0.0002 +/- 0.0001
hostname:sdfmilan216 rank:028 cpu:064 cmt:v1o2 proc time (sec) mean: 0.0105 +/- 0.0003 rms: 0.0003 +/- 0.0002
hostname:sdfmilan216 rank:028 cpu:069 cmt:v1o2 proc time (sec) mean: 0.0103 +/- 0.0001 rms: 0.0002 +/- 0.0001
hostname:sdfmilan216 rank:029 cpu:089 cmt:v1o2 proc time (sec) mean: 0.0103 +/- 0.0001 rms: 0.0002 +/- 0.0001
hostname:sdfmilan216 rank:029 cpu:089 cmt:v1o2 proc time (sec) mean: 0.0105 +/- 0.0002 rms: 0.0002 +/- 0.0001
hostname:sdfmilan216 rank:030 cpu:101 cmt:v1o2 proc time (sec) mean: 0.0106 +/- 0.0003 rms: 0.0003 +/- 0.0002
hostname:sdfmilan216 rank:030 cpu:111 cmt:v1o2 proc time (sec) mean: 0.0103 +/- 0.0001 rms: 0.0002 +/- 0.0001
hostname:sdfmilan216 rank:031 cpu:112 cmt:v1o2 proc time (sec) mean: 0.0103 +/- 0.0002 rms: 0.0003 +/- 0.0001
hostname:sdfmilan216 rank:031 cpu:116 cmt:v1o2 proc time (sec) mean: 0.0105 +/- 0.0002 rms: 0.0002 +/- 0.0001
hostname:sdfmilan216 rank:032 cpu:001 cmt:v1o2 proc time (sec) mean: 0.0109 +/- 0.0002 rms: 0.0003 +/- 0.0001
hostname:sdfmilan216 rank:032 cpu:012 cmt:v1o2 proc time (sec) mean: 0.0109 +/- 0.0005 rms: 0.0006 +/- 0.0003
hostname:sdfmilan216 rank:033 cpu:026 cmt:v1o2 proc time (sec) mean: 0.0107 +/- 0.0002 rms: 0.0003 +/- 0.0001
hostname:sdfmilan216 rank:033 cpu:029 cmt:v1o2 proc time (sec) mean: 0.0109 +/- 0.0004 rms: 0.0006 +/- 0.0003
hostname:sdfmilan216 rank:034 cpu:038 cmt:v1o2 proc time (sec) mean: 0.0109 +/- 0.0002 rms: 0.0004 +/- 0.0001
hostname:sdfmilan216 rank:034 cpu:047 cmt:v1o2 proc time (sec) mean: 0.0107 +/- 0.0004 rms: 0.0005 +/- 0.0003
hostname:sdfmilan216 rank:035 cpu:059 cmt:v1o2 proc time (sec) mean: 0.0105 +/- 0.0001 rms: 0.0001 +/- 0.0001
hostname:sdfmilan216 rank:035 cpu:061 cmt:v1o2 proc time (sec) mean: 0.0106 +/- 0.0001 rms: 0.0002 +/- 0.0001
hostname:sdfmilan216 rank:036 cpu:070 cmt:v1o2 proc time (sec) mean: 0.0105 +/- 0.0002 rms: 0.0002 +/- 0.0001
hostname:sdfmilan216 rank:036 cpu:072 cmt:v1o2 proc time (sec) mean: 0.0102 +/- 0.0002 rms: 0.0003 +/- 0.0001
hostname:sdfmilan216 rank:037 cpu:090 cmt:v1o2 proc time (sec) mean: 0.0103 +/- 0.0001 rms: 0.0002 +/- 0.0001
hostname:sdfmilan216 rank:037 cpu:090 cmt:v1o2 proc time (sec) mean: 0.0106 +/- 0.0003 rms: 0.0003 +/- 0.0002
hostname:sdfmilan216 rank:038 cpu:099 cmt:v1o2 proc time (sec) mean: 0.0105 +/- 0.0002 rms: 0.0002 +/- 0.0001
hostname:sdfmilan216 rank:038 cpu:104 cmt:v1o2 proc time (sec) mean: 0.0103 +/- 0.0001 rms: 0.0002 +/- 0.0001
hostname:sdfmilan216 rank:039 cpu:121 cmt:v1o2 proc time (sec) mean: 0.0103 +/- 0.0003 rms: 0.0004 +/- 0.0002
hostname:sdfmilan216 rank:039 cpu:125 cmt:v1o2 proc time (sec) mean: 0.0105 +/- 0.0002 rms: 0.0002 +/- 0.0002
hostname:sdfmilan216 rank:040 cpu:009 cmt:v1o2 proc time (sec) mean: 0.0109 +/- 0.0004 rms: 0.0006 +/- 0.0003
hostname:sdfmilan216 rank:040 cpu:013 cmt:v1o2 proc time (sec) mean: 0.0110 +/- 0.0002 rms: 0.0004 +/- 0.0001
hostname:sdfmilan216 rank:041 cpu:030 cmt:v1o2 proc time (sec) mean: 0.0108 +/- 0.0004 rms: 0.0005 +/- 0.0003
hostname:sdfmilan216 rank:041 cpu:031 cmt:v1o2 proc time (sec) mean: 0.0109 +/- 0.0002 rms: 0.0004 +/- 0.0002
hostname:sdfmilan216 rank:042 cpu:042 cmt:v1o2 proc time (sec) mean: 0.0108 +/- 0.0005 rms: 0.0006 +/- 0.0003
hostname:sdfmilan216 rank:042 cpu:045 cmt:v1o2 proc time (sec) mean: 0.0109 +/- 0.0002 rms: 0.0004 +/- 0.0001
hostname:sdfmilan216 rank:043 cpu:059 cmt:v1o2 proc time (sec) mean: 0.0106 +/- 0.0002 rms: 0.0002 +/- 0.0001
hostname:sdfmilan216 rank:043 cpu:062 cmt:v1o2 proc time (sec) mean: 0.0105 +/- 0.0002 rms: 0.0002 +/- 0.0001
hostname:sdfmilan216 rank:044 cpu:065 cmt:v1o2 proc time (sec) mean: 0.0105 +/- 0.0002 rms: 0.0002 +/- 0.0001
hostname:sdfmilan216 rank:044 cpu:074 cmt:v1o2 proc time (sec) mean: 0.0103 +/- 0.0001 rms: 0.0002 +/- 0.0001
hostname:sdfmilan216 rank:045 cpu:084 cmt:v1o2 proc time (sec) mean: 0.0106 +/- 0.0003 rms: 0.0003 +/- 0.0002
hostname:sdfmilan216 rank:045 cpu:092 cmt:v1o2 proc time (sec) mean: 0.0103 +/- 0.0002 rms: 0.0002 +/- 0.0001
hostname:sdfmilan216 rank:046 cpu:096 cmt:v1o2 proc time (sec) mean: 0.0103 +/- 0.0001 rms: 0.0002 +/- 0.0001
hostname:sdfmilan216 rank:046 cpu:098 cmt:v1o2 proc time (sec) mean: 0.0105 +/- 0.0002 rms: 0.0002 +/- 0.0001
hostname:sdfmilan216 rank:047 cpu:115 cmt:v1o2 proc time (sec) mean: 0.0102 +/- 0.0002 rms: 0.0002 +/- 0.0001
hostname:sdfmilan216 rank:047 cpu:126 cmt:v1o2 proc time (sec) mean: 0.0105 +/- 0.0002 rms: 0.0002 +/- 0.0002
hostname:sdfmilan216 rank:048 cpu:001 cmt:v1o2 proc time (sec) mean: 0.0110 +/- 0.0004 rms: 0.0006 +/- 0.0003
hostname:sdfmilan216 rank:048 cpu:007 cmt:v1o2 proc time (sec) mean: 0.0109 +/- 0.0002 rms: 0.0003 +/- 0.0001
hostname:sdfmilan216 rank:049 cpu:025 cmt:v1o2 proc time (sec) mean: 0.0108 +/- 0.0004 rms: 0.0005 +/- 0.0003
hostname:sdfmilan216 rank:049 cpu:028 cmt:v1o2 proc time (sec) mean: 0.0109 +/- 0.0002 rms: 0.0005 +/- 0.0002
hostname:sdfmilan216 rank:050 cpu:033 cmt:v1o2 proc time (sec) mean: 0.0108 +/- 0.0002 rms: 0.0003 +/- 0.0001
hostname:sdfmilan216 rank:050 cpu:040 cmt:v1o2 proc time (sec) mean: 0.0108 +/- 0.0004 rms: 0.0005 +/- 0.0003
hostname:sdfmilan216 rank:051 cpu:048 cmt:v1o2 proc time (sec) mean: 0.0106 +/- 0.0001 rms: 0.0002 +/- 0.0001
hostname:sdfmilan216 rank:051 cpu:050 cmt:v1o2 proc time (sec) mean: 0.0105 +/- 0.0001 rms: 0.0001 +/- 0.0001
hostname:sdfmilan216 rank:052 cpu:068 cmt:v1o2 proc time (sec) mean: 0.0103 +/- 0.0002 rms: 0.0003 +/- 0.0001
hostname:sdfmilan216 rank:052 cpu:074 cmt:v1o2 proc time (sec) mean: 0.0105 +/- 0.0002 rms: 0.0002 +/- 0.0001
hostname:sdfmilan216 rank:053 cpu:083 cmt:v1o2 proc time (sec) mean: 0.0103 +/- 0.0001 rms: 0.0002 +/- 0.0001
hostname:sdfmilan216 rank:053 cpu:088 cmt:v1o2 proc time (sec) mean: 0.0106 +/- 0.0003 rms: 0.0004 +/- 0.0002
hostname:sdfmilan216 rank:054 cpu:102 cmt:v1o2 proc time (sec) mean: 0.0105 +/- 0.0001 rms: 0.0001 +/- 0.0001
hostname:sdfmilan216 rank:054 cpu:109 cmt:v1o2 proc time (sec) mean: 0.0104 +/- 0.0001 rms: 0.0002 +/- 0.0001
hostname:sdfmilan216 rank:055 cpu:117 cmt:v1o2 proc time (sec) mean: 0.0103 +/- 0.0001 rms: 0.0002 +/- 0.0001
hostname:sdfmilan216 rank:055 cpu:118 cmt:v1o2 proc time (sec) mean: 0.0105 +/- 0.0003 rms: 0.0003 +/- 0.0002
hostname:sdfmilan216 rank:056 cpu:014 cmt:v1o2 proc time (sec) mean: 0.0108 +/- 0.0004 rms: 0.0006 +/- 0.0003
hostname:sdfmilan216 rank:056 cpu:015 cmt:v1o2 proc time (sec) mean: 0.0109 +/- 0.0002 rms: 0.0003 +/- 0.0001
hostname:sdfmilan216 rank:057 cpu:024 cmt:v1o2 proc time (sec) mean: 0.0109 +/- 0.0004 rms: 0.0006 +/- 0.0003
hostname:sdfmilan216 rank:057 cpu:030 cmt:v1o2 proc time (sec) mean: 0.0109 +/- 0.0002 rms: 0.0005 +/- 0.0002
hostname:sdfmilan216 rank:058 cpu:032 cmt:v1o2 proc time (sec) mean: 0.0110 +/- 0.0002 rms: 0.0004 +/- 0.0002
hostname:sdfmilan216 rank:058 cpu:044 cmt:v1o2 proc time (sec) mean: 0.0107 +/- 0.0003 rms: 0.0004 +/- 0.0002
hostname:sdfmilan216 rank:059 cpu:053 cmt:v1o2 proc time (sec) mean: 0.0105 +/- 0.0001 rms: 0.0002 +/- 0.0001
hostname:sdfmilan216 rank:059 cpu:063 cmt:v1o2 proc time (sec) mean: 0.0105 +/- 0.0001 rms: 0.0001 +/- 0.0001
hostname:sdfmilan216 rank:060 cpu:064 cmt:v1o2 proc time (sec) mean: 0.0103 +/- 0.0001 rms: 0.0002 +/- 0.0001
hostname:sdfmilan216 rank:060 cpu:075 cmt:v1o2 proc time (sec) mean: 0.0105 +/- 0.0002 rms: 0.0002 +/- 0.0001
hostname:sdfmilan216 rank:061 cpu:080 cmt:v1o2 proc time (sec) mean: 0.0105 +/- 0.0001 rms: 0.0001 +/- 0.0001
hostname:sdfmilan216 rank:061 cpu:082 cmt:v1o2 proc time (sec) mean: 0.0103 +/- 0.0002 rms: 0.0002 +/- 0.0001
hostname:sdfmilan216 rank:062 cpu:099 cmt:v1o2 proc time (sec) mean: 0.0103 +/- 0.0001 rms: 0.0002 +/- 0.0001
hostname:sdfmilan216 rank:062 cpu:106 cmt:v1o2 proc time (sec) mean: 0.0105 +/- 0.0002 rms: 0.0002 +/- 0.0001
hostname:sdfmilan216 rank:063 cpu:115 cmt:v1o2 proc time (sec) mean: 0.0105 +/- 0.0003 rms: 0.0003 +/- 0.0002
hostname:sdfmilan216 rank:063 cpu:122 cmt:v1o2 proc time (sec) mean: 0.0103 +/- 0.0002 rms: 0.0004 +/- 0.0002
hostname:sdfmilan216 rank:064 cpu:006 cmt:v1o2 proc time (sec) mean: 0.0109 +/- 0.0002 rms: 0.0004 +/- 0.0001
hostname:sdfmilan216 rank:064 cpu:010 cmt:v1o2 proc time (sec) mean: 0.0109 +/- 0.0004 rms: 0.0006 +/- 0.0003
hostname:sdfmilan216 rank:065 cpu:038 cmt:v1o2 proc time (sec) mean: 0.0108 +/- 0.0003 rms: 0.0004 +/- 0.0002
hostname:sdfmilan216 rank:065 cpu:041 cmt:v1o2 proc time (sec) mean: 0.0109 +/- 0.0002 rms: 0.0004 +/- 0.0002
hostname:sdfmilan216 rank:066 cpu:040 cmt:v1o2 proc time (sec) mean: 0.0108 +/- 0.0002 rms: 0.0003 +/- 0.0001
hostname:sdfmilan216 rank:066 cpu:041 cmt:v1o2 proc time (sec) mean: 0.0109 +/- 0.0004 rms: 0.0006 +/- 0.0003
hostname:sdfmilan216 rank:067 cpu:049 cmt:v1o2 proc time (sec) mean: 0.0105 +/- 0.0001 rms: 0.0001 +/- 0.0001
hostname:sdfmilan216 rank:067 cpu:063 cmt:v1o2 proc time (sec) mean: 0.0106 +/- 0.0001 rms: 0.0002 +/- 0.0001
hostname:sdfmilan216 rank:068 cpu:066 cmt:v1o2 proc time (sec) mean: 0.0102 +/- 0.0002 rms: 0.0002 +/- 0.0001
hostname:sdfmilan216 rank:068 cpu:078 cmt:v1o2 proc time (sec) mean: 0.0105 +/- 0.0003 rms: 0.0003 +/- 0.0002
hostname:sdfmilan216 rank:069 cpu:087 cmt:v1o2 proc time (sec) mean: 0.0105 +/- 0.0001 rms: 0.0001 +/- 0.0001
hostname:sdfmilan216 rank:069 cpu:088 cmt:v1o2 proc time (sec) mean: 0.0103 +/- 0.0001 rms: 0.0002 +/- 0.0001
hostname:sdfmilan216 rank:070 cpu:101 cmt:v1o2 proc time (sec) mean: 0.0103 +/- 0.0001 rms: 0.0002 +/- 0.0001
hostname:sdfmilan216 rank:070 cpu:104 cmt:v1o2 proc time (sec) mean: 0.0106 +/- 0.0003 rms: 0.0004 +/- 0.0002
hostname:sdfmilan216 rank:071 cpu:114 cmt:v1o2 proc time (sec) mean: 0.0105 +/- 0.0001 rms: 0.0001 +/- 0.0001
hostname:sdfmilan216 rank:071 cpu:119 cmt:v1o2 proc time (sec) mean: 0.0103 +/- 0.0001 rms: 0.0002 +/- 0.0001
hostname:sdfmilan216 rank:072 cpu:003 cmt:v1o2 proc time (sec) mean: 0.0109 +/- 0.0002 rms: 0.0004 +/- 0.0001
hostname:sdfmilan216 rank:072 cpu:008 cmt:v1o2 proc time (sec) mean: 0.0109 +/- 0.0004 rms: 0.0005 +/- 0.0003
hostname:sdfmilan216 rank:073 cpu:035 cmt:v1o2 proc time (sec) mean: 0.0107 +/- 0.0003 rms: 0.0004 +/- 0.0002
hostname:sdfmilan216 rank:073 cpu:039 cmt:v1o2 proc time (sec) mean: 0.0108 +/- 0.0002 rms: 0.0004 +/- 0.0001
hostname:sdfmilan216 rank:074 cpu:035 cmt:v1o2 proc time (sec) mean: 0.0109 +/- 0.0002 rms: 0.0003 +/- 0.0001
hostname:sdfmilan216 rank:074 cpu:037 cmt:v1o2 proc time (sec) mean: 0.0107 +/- 0.0004 rms: 0.0005 +/- 0.0003
hostname:sdfmilan216 rank:075 cpu:056 cmt:v1o2 proc time (sec) mean: 0.0105 +/- 0.0001 rms: 0.0002 +/- 0.0001
hostname:sdfmilan216 rank:075 cpu:058 cmt:v1o2 proc time (sec) mean: 0.0105 +/- 0.0001 rms: 0.0001 +/- 0.0001
hostname:sdfmilan216 rank:076 cpu:070 cmt:v1o2 proc time (sec) mean: 0.0102 +/- 0.0001 rms: 0.0002 +/- 0.0001
hostname:sdfmilan216 rank:076 cpu:079 cmt:v1o2 proc time (sec) mean: 0.0105 +/- 0.0001 rms: 0.0001 +/- 0.0001
hostname:sdfmilan216 rank:077 cpu:091 cmt:v1o2 proc time (sec) mean: 0.0103 +/- 0.0001 rms: 0.0002 +/- 0.0001
hostname:sdfmilan216 rank:077 cpu:092 cmt:v1o2 proc time (sec) mean: 0.0105 +/- 0.0002 rms: 0.0002 +/- 0.0001
hostname:sdfmilan216 rank:078 cpu:102 cmt:v1o2 proc time (sec) mean: 0.0103 +/- 0.0001 rms: 0.0002 +/- 0.0001
hostname:sdfmilan216 rank:078 cpu:109 cmt:v1o2 proc time (sec) mean: 0.0104 +/- 0.0003 rms: 0.0003 +/- 0.0002
hostname:sdfmilan216 rank:079 cpu:120 cmt:v1o2 proc time (sec) mean: 0.0103 +/- 0.0002 rms: 0.0004 +/- 0.0002
hostname:sdfmilan216 rank:079 cpu:121 cmt:v1o2 proc time (sec) mean: 0.0105 +/- 0.0002 rms: 0.0002 +/- 0.0001
mean time (sec): 0.0106



sort_records_in_file: figs/fig-mpi-rand-v1o4-sdfmilan216-ncores80-summary.txt
records:
means: shape:(80,) size:80 dtype:float64
[0.0055 0.0053 0.0054 0.0054 0.0052 0.0052 0.0052 0.0052 0.0055 0.0053
 0.0054 0.0054 0.0053 0.0053 0.0052 0.0052 0.0055 0.0053 0.0054 0.0054
 0.0052 0.0053 0.0052 0.0052 0.0054 0.0053 0.0054 0.0054 0.0052 0.0052
 0.0052 0.0052 0.0054 0.0053 0.0053 0.0053 0.0052 0.0052 0.0052 0.0052
 0.0055 0.0053 0.0054 0.0054 0.0052 0.0052 0.0052 0.0052 0.0055 0.0053
 0.0053 0.0073 0.0052 0.0052 0.0052 0.0053 0.0054 0.0053 0.0054 0.0054
 0.0053 0.0052 0.0052 0.0052 0.0054 0.0053 0.0054 0.0054 0.0053 0.0053
 0.0052 0.0053 0.0055 0.0054 0.0053 0.0054 0.0053 0.0052 0.0052 0.0053]
mean time (sec): 0.0053

hostname:sdfmilan216 rank:000 cpu:006 cmt:v1o4 proc time (sec) mean: 0.0055 +/- 0.0005 rms: 0.0006 +/- 0.0003
hostname:sdfmilan216 rank:001 cpu:027 cmt:v1o4 proc time (sec) mean: 0.0053 +/- 0.0003 rms: 0.0004 +/- 0.0002
hostname:sdfmilan216 rank:002 cpu:039 cmt:v1o4 proc time (sec) mean: 0.0054 +/- 0.0003 rms: 0.0005 +/- 0.0002
hostname:sdfmilan216 rank:003 cpu:057 cmt:v1o4 proc time (sec) mean: 0.0054 +/- 0.0001 rms: 0.0002 +/- 0.0001
hostname:sdfmilan216 rank:004 cpu:065 cmt:v1o4 proc time (sec) mean: 0.0052 +/- 0.0002 rms: 0.0002 +/- 0.0001
hostname:sdfmilan216 rank:005 cpu:083 cmt:v1o4 proc time (sec) mean: 0.0052 +/- 0.0002 rms: 0.0003 +/- 0.0001
hostname:sdfmilan216 rank:006 cpu:111 cmt:v1o4 proc time (sec) mean: 0.0052 +/- 0.0001 rms: 0.0002 +/- 0.0001
hostname:sdfmilan216 rank:007 cpu:122 cmt:v1o4 proc time (sec) mean: 0.0052 +/- 0.0001 rms: 0.0002 +/- 0.0001
hostname:sdfmilan216 rank:008 cpu:008 cmt:v1o4 proc time (sec) mean: 0.0055 +/- 0.0005 rms: 0.0007 +/- 0.0004
hostname:sdfmilan216 rank:009 cpu:030 cmt:v1o4 proc time (sec) mean: 0.0053 +/- 0.0003 rms: 0.0004 +/- 0.0002
hostname:sdfmilan216 rank:010 cpu:042 cmt:v1o4 proc time (sec) mean: 0.0054 +/- 0.0004 rms: 0.0005 +/- 0.0002
hostname:sdfmilan216 rank:011 cpu:051 cmt:v1o4 proc time (sec) mean: 0.0054 +/- 0.0001 rms: 0.0001 +/- 0.0001
hostname:sdfmilan216 rank:012 cpu:078 cmt:v1o4 proc time (sec) mean: 0.0053 +/- 0.0001 rms: 0.0002 +/- 0.0001
hostname:sdfmilan216 rank:013 cpu:090 cmt:v1o4 proc time (sec) mean: 0.0053 +/- 0.0001 rms: 0.0002 +/- 0.0001
hostname:sdfmilan216 rank:014 cpu:107 cmt:v1o4 proc time (sec) mean: 0.0052 +/- 0.0001 rms: 0.0001 +/- 0.0001
hostname:sdfmilan216 rank:015 cpu:126 cmt:v1o4 proc time (sec) mean: 0.0052 +/- 0.0001 rms: 0.0002 +/- 0.0001
hostname:sdfmilan216 rank:016 cpu:001 cmt:v1o4 proc time (sec) mean: 0.0055 +/- 0.0004 rms: 0.0004 +/- 0.0003
hostname:sdfmilan216 rank:017 cpu:031 cmt:v1o4 proc time (sec) mean: 0.0053 +/- 0.0003 rms: 0.0004 +/- 0.0002
hostname:sdfmilan216 rank:018 cpu:045 cmt:v1o4 proc time (sec) mean: 0.0054 +/- 0.0004 rms: 0.0005 +/- 0.0003
hostname:sdfmilan216 rank:019 cpu:049 cmt:v1o4 proc time (sec) mean: 0.0054 +/- 0.0001 rms: 0.0001 +/- 0.0001
hostname:sdfmilan216 rank:020 cpu:077 cmt:v1o4 proc time (sec) mean: 0.0052 +/- 0.0001 rms: 0.0002 +/- 0.0001
hostname:sdfmilan216 rank:021 cpu:094 cmt:v1o4 proc time (sec) mean: 0.0053 +/- 0.0001 rms: 0.0002 +/- 0.0001
hostname:sdfmilan216 rank:022 cpu:109 cmt:v1o4 proc time (sec) mean: 0.0052 +/- 0.0001 rms: 0.0001 +/- 0.0001
hostname:sdfmilan216 rank:023 cpu:119 cmt:v1o4 proc time (sec) mean: 0.0052 +/- 0.0001 rms: 0.0001 +/- 0.0001
hostname:sdfmilan216 rank:024 cpu:013 cmt:v1o4 proc time (sec) mean: 0.0054 +/- 0.0003 rms: 0.0004 +/- 0.0002
hostname:sdfmilan216 rank:025 cpu:026 cmt:v1o4 proc time (sec) mean: 0.0053 +/- 0.0003 rms: 0.0004 +/- 0.0002
hostname:sdfmilan216 rank:026 cpu:041 cmt:v1o4 proc time (sec) mean: 0.0054 +/- 0.0003 rms: 0.0003 +/- 0.0002
hostname:sdfmilan216 rank:027 cpu:060 cmt:v1o4 proc time (sec) mean: 0.0054 +/- 0.0002 rms: 0.0002 +/- 0.0001
hostname:sdfmilan216 rank:028 cpu:070 cmt:v1o4 proc time (sec) mean: 0.0052 +/- 0.0001 rms: 0.0001 +/- 0.0001
hostname:sdfmilan216 rank:029 cpu:087 cmt:v1o4 proc time (sec) mean: 0.0052 +/- 0.0001 rms: 0.0002 +/- 0.0001
hostname:sdfmilan216 rank:030 cpu:101 cmt:v1o4 proc time (sec) mean: 0.0052 +/- 0.0001 rms: 0.0001 +/- 0.0001
hostname:sdfmilan216 rank:031 cpu:116 cmt:v1o4 proc time (sec) mean: 0.0052 +/- 0.0001 rms: 0.0002 +/- 0.0001
hostname:sdfmilan216 rank:032 cpu:010 cmt:v1o4 proc time (sec) mean: 0.0054 +/- 0.0003 rms: 0.0004 +/- 0.0002
hostname:sdfmilan216 rank:033 cpu:029 cmt:v1o4 proc time (sec) mean: 0.0053 +/- 0.0003 rms: 0.0004 +/- 0.0002
hostname:sdfmilan216 rank:034 cpu:032 cmt:v1o4 proc time (sec) mean: 0.0053 +/- 0.0004 rms: 0.0005 +/- 0.0003
hostname:sdfmilan216 rank:035 cpu:052 cmt:v1o4 proc time (sec) mean: 0.0053 +/- 0.0001 rms: 0.0001 +/- 0.0001
hostname:sdfmilan216 rank:036 cpu:066 cmt:v1o4 proc time (sec) mean: 0.0052 +/- 0.0001 rms: 0.0001 +/- 0.0001
hostname:sdfmilan216 rank:037 cpu:081 cmt:v1o4 proc time (sec) mean: 0.0052 +/- 0.0001 rms: 0.0001 +/- 0.0001
hostname:sdfmilan216 rank:038 cpu:102 cmt:v1o4 proc time (sec) mean: 0.0052 +/- 0.0001 rms: 0.0002 +/- 0.0001
hostname:sdfmilan216 rank:039 cpu:127 cmt:v1o4 proc time (sec) mean: 0.0052 +/- 0.0001 rms: 0.0002 +/- 0.0001
hostname:sdfmilan216 rank:040 cpu:012 cmt:v1o4 proc time (sec) mean: 0.0055 +/- 0.0005 rms: 0.0007 +/- 0.0004
hostname:sdfmilan216 rank:041 cpu:025 cmt:v1o4 proc time (sec) mean: 0.0053 +/- 0.0002 rms: 0.0003 +/- 0.0002
hostname:sdfmilan216 rank:042 cpu:040 cmt:v1o4 proc time (sec) mean: 0.0054 +/- 0.0003 rms: 0.0004 +/- 0.0002
hostname:sdfmilan216 rank:043 cpu:061 cmt:v1o4 proc time (sec) mean: 0.0054 +/- 0.0002 rms: 0.0002 +/- 0.0001
hostname:sdfmilan216 rank:044 cpu:075 cmt:v1o4 proc time (sec) mean: 0.0052 +/- 0.0001 rms: 0.0001 +/- 0.0001
hostname:sdfmilan216 rank:045 cpu:084 cmt:v1o4 proc time (sec) mean: 0.0052 +/- 0.0001 rms: 0.0001 +/- 0.0001
hostname:sdfmilan216 rank:046 cpu:097 cmt:v1o4 proc time (sec) mean: 0.0052 +/- 0.0001 rms: 0.0001 +/- 0.0001
hostname:sdfmilan216 rank:047 cpu:121 cmt:v1o4 proc time (sec) mean: 0.0052 +/- 0.0001 rms: 0.0001 +/- 0.0001
hostname:sdfmilan216 rank:048 cpu:002 cmt:v1o4 proc time (sec) mean: 0.0055 +/- 0.0003 rms: 0.0004 +/- 0.0002
hostname:sdfmilan216 rank:049 cpu:028 cmt:v1o4 proc time (sec) mean: 0.0053 +/- 0.0003 rms: 0.0004 +/- 0.0002
hostname:sdfmilan216 rank:050 cpu:036 cmt:v1o4 proc time (sec) mean: 0.0053 +/- 0.0004 rms: 0.0005 +/- 0.0003
hostname:sdfmilan216 rank:051 cpu:058 cmt:v1o4 proc time (sec) mean: 0.0073 +/- 0.0004 rms: 0.0007 +/- 0.0003
hostname:sdfmilan216 rank:052 cpu:072 cmt:v1o4 proc time (sec) mean: 0.0052 +/- 0.0001 rms: 0.0001 +/- 0.0001
hostname:sdfmilan216 rank:053 cpu:091 cmt:v1o4 proc time (sec) mean: 0.0052 +/- 0.0001 rms: 0.0002 +/- 0.0001
hostname:sdfmilan216 rank:054 cpu:106 cmt:v1o4 proc time (sec) mean: 0.0052 +/- 0.0001 rms: 0.0002 +/- 0.0001
hostname:sdfmilan216 rank:055 cpu:124 cmt:v1o4 proc time (sec) mean: 0.0053 +/- 0.0001 rms: 0.0002 +/- 0.0001
hostname:sdfmilan216 rank:056 cpu:014 cmt:v1o4 proc time (sec) mean: 0.0054 +/- 0.0003 rms: 0.0004 +/- 0.0002
hostname:sdfmilan216 rank:057 cpu:024 cmt:v1o4 proc time (sec) mean: 0.0053 +/- 0.0003 rms: 0.0004 +/- 0.0002
hostname:sdfmilan216 rank:058 cpu:035 cmt:v1o4 proc time (sec) mean: 0.0054 +/- 0.0003 rms: 0.0004 +/- 0.0002
hostname:sdfmilan216 rank:059 cpu:059 cmt:v1o4 proc time (sec) mean: 0.0054 +/- 0.0002 rms: 0.0002 +/- 0.0001
hostname:sdfmilan216 rank:060 cpu:071 cmt:v1o4 proc time (sec) mean: 0.0053 +/- 0.0001 rms: 0.0002 +/- 0.0001
hostname:sdfmilan216 rank:061 cpu:080 cmt:v1o4 proc time (sec) mean: 0.0052 +/- 0.0001 rms: 0.0002 +/- 0.0001
hostname:sdfmilan216 rank:062 cpu:110 cmt:v1o4 proc time (sec) mean: 0.0052 +/- 0.0001 rms: 0.0001 +/- 0.0001
hostname:sdfmilan216 rank:063 cpu:115 cmt:v1o4 proc time (sec) mean: 0.0052 +/- 0.0001 rms: 0.0001 +/- 0.0001
hostname:sdfmilan216 rank:064 cpu:000 cmt:v1o4 proc time (sec) mean: 0.0054 +/- 0.0003 rms: 0.0004 +/- 0.0002
hostname:sdfmilan216 rank:065 cpu:038 cmt:v1o4 proc time (sec) mean: 0.0053 +/- 0.0004 rms: 0.0005 +/- 0.0003
hostname:sdfmilan216 rank:066 cpu:044 cmt:v1o4 proc time (sec) mean: 0.0054 +/- 0.0003 rms: 0.0004 +/- 0.0002
hostname:sdfmilan216 rank:067 cpu:054 cmt:v1o4 proc time (sec) mean: 0.0054 +/- 0.0001 rms: 0.0001 +/- 0.0001
hostname:sdfmilan216 rank:068 cpu:079 cmt:v1o4 proc time (sec) mean: 0.0053 +/- 0.0001 rms: 0.0002 +/- 0.0001
hostname:sdfmilan216 rank:069 cpu:095 cmt:v1o4 proc time (sec) mean: 0.0053 +/- 0.0001 rms: 0.0002 +/- 0.0001
hostname:sdfmilan216 rank:070 cpu:096 cmt:v1o4 proc time (sec) mean: 0.0052 +/- 0.0001 rms: 0.0001 +/- 0.0001
hostname:sdfmilan216 rank:071 cpu:114 cmt:v1o4 proc time (sec) mean: 0.0053 +/- 0.0001 rms: 0.0002 +/- 0.0001
hostname:sdfmilan216 rank:072 cpu:003 cmt:v1o4 proc time (sec) mean: 0.0055 +/- 0.0006 rms: 0.0007 +/- 0.0004
hostname:sdfmilan216 rank:073 cpu:047 cmt:v1o4 proc time (sec) mean: 0.0054 +/- 0.0004 rms: 0.0004 +/- 0.0003
hostname:sdfmilan216 rank:074 cpu:037 cmt:v1o4 proc time (sec) mean: 0.0053 +/- 0.0002 rms: 0.0003 +/- 0.0002
hostname:sdfmilan216 rank:075 cpu:053 cmt:v1o4 proc time (sec) mean: 0.0054 +/- 0.0001 rms: 0.0001 +/- 0.0001
hostname:sdfmilan216 rank:076 cpu:069 cmt:v1o4 proc time (sec) mean: 0.0053 +/- 0.0002 rms: 0.0003 +/- 0.0001
hostname:sdfmilan216 rank:077 cpu:093 cmt:v1o4 proc time (sec) mean: 0.0052 +/- 0.0001 rms: 0.0001 +/- 0.0001
hostname:sdfmilan216 rank:078 cpu:103 cmt:v1o4 proc time (sec) mean: 0.0052 +/- 0.0002 rms: 0.0002 +/- 0.0001
hostname:sdfmilan216 rank:079 cpu:118 cmt:v1o4 proc time (sec) mean: 0.0053 +/- 0.0002 rms: 0.0002 +/- 0.0001
mean time (sec): 0.0053



sort_records_in_file: figs/fig-mpi-rand-v1o8-sdfmilan216-ncores80-summary.txt
records:
means: shape:(80,) size:80 dtype:float64
[0.0026 0.0026 0.0026 0.0026 0.0027 0.0026 0.0026 0.0027 0.0026 0.0027
 0.0026 0.0026 0.0027 0.0026 0.0026 0.0026 0.0027 0.0026 0.0026 0.0026
 0.0026 0.0027 0.0027 0.0026 0.0026 0.0026 0.0026 0.0026 0.0026 0.0026
 0.0026 0.0026 0.0026 0.0026 0.0026 0.0026 0.0027 0.0026 0.0027 0.0027
 0.0027 0.0026 0.0026 0.0026 0.0026 0.0026 0.0026 0.0027 0.0026 0.0026
 0.0026 0.0026 0.0026 0.0026 0.0027 0.0026 0.0026 0.0026 0.0026 0.0026
 0.0026 0.0026 0.0026 0.0026 0.0027 0.0026 0.0026 0.0026 0.0026 0.0026
 0.0026 0.0026 0.0027 0.0026 0.0026 0.0026 0.0026 0.0026 0.0027 0.0027]
mean time (sec): 0.0026

hostname:sdfmilan216 rank:000 cpu:001 cmt:v1o8 proc time (sec) mean: 0.0026 +/- 0.0001 rms: 0.0001 +/- 0.0000
hostname:sdfmilan216 rank:001 cpu:026 cmt:v1o8 proc time (sec) mean: 0.0026 +/- 0.0000 rms: 0.0000 +/- 0.0000
hostname:sdfmilan216 rank:002 cpu:035 cmt:v1o8 proc time (sec) mean: 0.0026 +/- 0.0000 rms: 0.0000 +/- 0.0000
hostname:sdfmilan216 rank:003 cpu:059 cmt:v1o8 proc time (sec) mean: 0.0026 +/- 0.0001 rms: 0.0001 +/- 0.0001
hostname:sdfmilan216 rank:004 cpu:076 cmt:v1o8 proc time (sec) mean: 0.0027 +/- 0.0001 rms: 0.0002 +/- 0.0001
hostname:sdfmilan216 rank:005 cpu:082 cmt:v1o8 proc time (sec) mean: 0.0026 +/- 0.0000 rms: 0.0000 +/- 0.0000
hostname:sdfmilan216 rank:006 cpu:104 cmt:v1o8 proc time (sec) mean: 0.0026 +/- 0.0001 rms: 0.0001 +/- 0.0000
hostname:sdfmilan216 rank:007 cpu:114 cmt:v1o8 proc time (sec) mean: 0.0027 +/- 0.0001 rms: 0.0001 +/- 0.0000
hostname:sdfmilan216 rank:008 cpu:004 cmt:v1o8 proc time (sec) mean: 0.0026 +/- 0.0001 rms: 0.0001 +/- 0.0000
hostname:sdfmilan216 rank:009 cpu:031 cmt:v1o8 proc time (sec) mean: 0.0027 +/- 0.0001 rms: 0.0001 +/- 0.0001
hostname:sdfmilan216 rank:010 cpu:040 cmt:v1o8 proc time (sec) mean: 0.0026 +/- 0.0000 rms: 0.0000 +/- 0.0000
hostname:sdfmilan216 rank:011 cpu:054 cmt:v1o8 proc time (sec) mean: 0.0026 +/- 0.0001 rms: 0.0001 +/- 0.0000
hostname:sdfmilan216 rank:012 cpu:073 cmt:v1o8 proc time (sec) mean: 0.0027 +/- 0.0001 rms: 0.0001 +/- 0.0001
hostname:sdfmilan216 rank:013 cpu:080 cmt:v1o8 proc time (sec) mean: 0.0026 +/- 0.0000 rms: 0.0000 +/- 0.0000
hostname:sdfmilan216 rank:014 cpu:100 cmt:v1o8 proc time (sec) mean: 0.0026 +/- 0.0001 rms: 0.0001 +/- 0.0000
hostname:sdfmilan216 rank:015 cpu:116 cmt:v1o8 proc time (sec) mean: 0.0026 +/- 0.0001 rms: 0.0001 +/- 0.0000
hostname:sdfmilan216 rank:016 cpu:011 cmt:v1o8 proc time (sec) mean: 0.0027 +/- 0.0001 rms: 0.0001 +/- 0.0001
hostname:sdfmilan216 rank:017 cpu:025 cmt:v1o8 proc time (sec) mean: 0.0026 +/- 0.0000 rms: 0.0000 +/- 0.0000
hostname:sdfmilan216 rank:018 cpu:046 cmt:v1o8 proc time (sec) mean: 0.0026 +/- 0.0000 rms: 0.0000 +/- 0.0000
hostname:sdfmilan216 rank:019 cpu:048 cmt:v1o8 proc time (sec) mean: 0.0026 +/- 0.0000 rms: 0.0000 +/- 0.0000
hostname:sdfmilan216 rank:020 cpu:069 cmt:v1o8 proc time (sec) mean: 0.0026 +/- 0.0000 rms: 0.0000 +/- 0.0000
hostname:sdfmilan216 rank:021 cpu:094 cmt:v1o8 proc time (sec) mean: 0.0027 +/- 0.0001 rms: 0.0001 +/- 0.0001
hostname:sdfmilan216 rank:022 cpu:101 cmt:v1o8 proc time (sec) mean: 0.0027 +/- 0.0001 rms: 0.0001 +/- 0.0001
hostname:sdfmilan216 rank:023 cpu:127 cmt:v1o8 proc time (sec) mean: 0.0026 +/- 0.0001 rms: 0.0001 +/- 0.0000
hostname:sdfmilan216 rank:024 cpu:012 cmt:v1o8 proc time (sec) mean: 0.0026 +/- 0.0001 rms: 0.0001 +/- 0.0000
hostname:sdfmilan216 rank:025 cpu:029 cmt:v1o8 proc time (sec) mean: 0.0026 +/- 0.0000 rms: 0.0000 +/- 0.0000
hostname:sdfmilan216 rank:026 cpu:044 cmt:v1o8 proc time (sec) mean: 0.0026 +/- 0.0000 rms: 0.0000 +/- 0.0000
hostname:sdfmilan216 rank:027 cpu:049 cmt:v1o8 proc time (sec) mean: 0.0026 +/- 0.0000 rms: 0.0000 +/- 0.0000
hostname:sdfmilan216 rank:028 cpu:071 cmt:v1o8 proc time (sec) mean: 0.0026 +/- 0.0001 rms: 0.0001 +/- 0.0000
hostname:sdfmilan216 rank:029 cpu:085 cmt:v1o8 proc time (sec) mean: 0.0026 +/- 0.0001 rms: 0.0001 +/- 0.0000
hostname:sdfmilan216 rank:030 cpu:099 cmt:v1o8 proc time (sec) mean: 0.0026 +/- 0.0001 rms: 0.0001 +/- 0.0000
hostname:sdfmilan216 rank:031 cpu:119 cmt:v1o8 proc time (sec) mean: 0.0026 +/- 0.0000 rms: 0.0000 +/- 0.0000
hostname:sdfmilan216 rank:032 cpu:007 cmt:v1o8 proc time (sec) mean: 0.0026 +/- 0.0001 rms: 0.0001 +/- 0.0000
hostname:sdfmilan216 rank:033 cpu:027 cmt:v1o8 proc time (sec) mean: 0.0026 +/- 0.0000 rms: 0.0000 +/- 0.0000
hostname:sdfmilan216 rank:034 cpu:047 cmt:v1o8 proc time (sec) mean: 0.0026 +/- 0.0000 rms: 0.0000 +/- 0.0000
hostname:sdfmilan216 rank:035 cpu:058 cmt:v1o8 proc time (sec) mean: 0.0026 +/- 0.0002 rms: 0.0002 +/- 0.0001
hostname:sdfmilan216 rank:036 cpu:068 cmt:v1o8 proc time (sec) mean: 0.0027 +/- 0.0001 rms: 0.0001 +/- 0.0001
hostname:sdfmilan216 rank:037 cpu:095 cmt:v1o8 proc time (sec) mean: 0.0026 +/- 0.0001 rms: 0.0001 +/- 0.0000
hostname:sdfmilan216 rank:038 cpu:102 cmt:v1o8 proc time (sec) mean: 0.0027 +/- 0.0001 rms: 0.0001 +/- 0.0001
hostname:sdfmilan216 rank:039 cpu:121 cmt:v1o8 proc time (sec) mean: 0.0027 +/- 0.0001 rms: 0.0001 +/- 0.0001
hostname:sdfmilan216 rank:040 cpu:014 cmt:v1o8 proc time (sec) mean: 0.0027 +/- 0.0001 rms: 0.0001 +/- 0.0000
hostname:sdfmilan216 rank:041 cpu:030 cmt:v1o8 proc time (sec) mean: 0.0026 +/- 0.0000 rms: 0.0000 +/- 0.0000
hostname:sdfmilan216 rank:042 cpu:036 cmt:v1o8 proc time (sec) mean: 0.0026 +/- 0.0001 rms: 0.0001 +/- 0.0000
hostname:sdfmilan216 rank:043 cpu:052 cmt:v1o8 proc time (sec) mean: 0.0026 +/- 0.0000 rms: 0.0000 +/- 0.0000
hostname:sdfmilan216 rank:044 cpu:065 cmt:v1o8 proc time (sec) mean: 0.0026 +/- 0.0000 rms: 0.0000 +/- 0.0000
hostname:sdfmilan216 rank:045 cpu:081 cmt:v1o8 proc time (sec) mean: 0.0026 +/- 0.0001 rms: 0.0001 +/- 0.0000
hostname:sdfmilan216 rank:046 cpu:098 cmt:v1o8 proc time (sec) mean: 0.0026 +/- 0.0000 rms: 0.0000 +/- 0.0000
hostname:sdfmilan216 rank:047 cpu:124 cmt:v1o8 proc time (sec) mean: 0.0027 +/- 0.0001 rms: 0.0001 +/- 0.0001
hostname:sdfmilan216 rank:048 cpu:008 cmt:v1o8 proc time (sec) mean: 0.0026 +/- 0.0001 rms: 0.0001 +/- 0.0000
hostname:sdfmilan216 rank:049 cpu:028 cmt:v1o8 proc time (sec) mean: 0.0026 +/- 0.0001 rms: 0.0001 +/- 0.0001
hostname:sdfmilan216 rank:050 cpu:039 cmt:v1o8 proc time (sec) mean: 0.0026 +/- 0.0001 rms: 0.0001 +/- 0.0000
hostname:sdfmilan216 rank:051 cpu:055 cmt:v1o8 proc time (sec) mean: 0.0026 +/- 0.0000 rms: 0.0000 +/- 0.0000
hostname:sdfmilan216 rank:052 cpu:072 cmt:v1o8 proc time (sec) mean: 0.0026 +/- 0.0000 rms: 0.0000 +/- 0.0000
hostname:sdfmilan216 rank:053 cpu:091 cmt:v1o8 proc time (sec) mean: 0.0026 +/- 0.0001 rms: 0.0001 +/- 0.0000
hostname:sdfmilan216 rank:054 cpu:108 cmt:v1o8 proc time (sec) mean: 0.0027 +/- 0.0001 rms: 0.0001 +/- 0.0000
hostname:sdfmilan216 rank:055 cpu:112 cmt:v1o8 proc time (sec) mean: 0.0026 +/- 0.0001 rms: 0.0001 +/- 0.0000
hostname:sdfmilan216 rank:056 cpu:005 cmt:v1o8 proc time (sec) mean: 0.0026 +/- 0.0001 rms: 0.0001 +/- 0.0000
hostname:sdfmilan216 rank:057 cpu:024 cmt:v1o8 proc time (sec) mean: 0.0026 +/- 0.0000 rms: 0.0000 +/- 0.0000
hostname:sdfmilan216 rank:058 cpu:043 cmt:v1o8 proc time (sec) mean: 0.0026 +/- 0.0002 rms: 0.0002 +/- 0.0001
hostname:sdfmilan216 rank:059 cpu:057 cmt:v1o8 proc time (sec) mean: 0.0026 +/- 0.0000 rms: 0.0000 +/- 0.0000
hostname:sdfmilan216 rank:060 cpu:074 cmt:v1o8 proc time (sec) mean: 0.0026 +/- 0.0000 rms: 0.0000 +/- 0.0000
hostname:sdfmilan216 rank:061 cpu:084 cmt:v1o8 proc time (sec) mean: 0.0026 +/- 0.0001 rms: 0.0001 +/- 0.0000
hostname:sdfmilan216 rank:062 cpu:109 cmt:v1o8 proc time (sec) mean: 0.0026 +/- 0.0001 rms: 0.0001 +/- 0.0000
hostname:sdfmilan216 rank:063 cpu:115 cmt:v1o8 proc time (sec) mean: 0.0026 +/- 0.0000 rms: 0.0000 +/- 0.0000
hostname:sdfmilan216 rank:064 cpu:013 cmt:v1o8 proc time (sec) mean: 0.0027 +/- 0.0001 rms: 0.0001 +/- 0.0000
hostname:sdfmilan216 rank:065 cpu:034 cmt:v1o8 proc time (sec) mean: 0.0026 +/- 0.0001 rms: 0.0001 +/- 0.0000
hostname:sdfmilan216 rank:066 cpu:042 cmt:v1o8 proc time (sec) mean: 0.0026 +/- 0.0001 rms: 0.0001 +/- 0.0000
hostname:sdfmilan216 rank:067 cpu:063 cmt:v1o8 proc time (sec) mean: 0.0026 +/- 0.0000 rms: 0.0000 +/- 0.0000
hostname:sdfmilan216 rank:068 cpu:064 cmt:v1o8 proc time (sec) mean: 0.0026 +/- 0.0000 rms: 0.0000 +/- 0.0000
hostname:sdfmilan216 rank:069 cpu:093 cmt:v1o8 proc time (sec) mean: 0.0026 +/- 0.0001 rms: 0.0002 +/- 0.0001
hostname:sdfmilan216 rank:070 cpu:105 cmt:v1o8 proc time (sec) mean: 0.0026 +/- 0.0001 rms: 0.0001 +/- 0.0000
hostname:sdfmilan216 rank:071 cpu:122 cmt:v1o8 proc time (sec) mean: 0.0026 +/- 0.0001 rms: 0.0001 +/- 0.0000
hostname:sdfmilan216 rank:072 cpu:000 cmt:v1o8 proc time (sec) mean: 0.0027 +/- 0.0001 rms: 0.0001 +/- 0.0001
hostname:sdfmilan216 rank:073 cpu:038 cmt:v1o8 proc time (sec) mean: 0.0026 +/- 0.0001 rms: 0.0001 +/- 0.0001
hostname:sdfmilan216 rank:074 cpu:037 cmt:v1o8 proc time (sec) mean: 0.0026 +/- 0.0001 rms: 0.0002 +/- 0.0001
hostname:sdfmilan216 rank:075 cpu:060 cmt:v1o8 proc time (sec) mean: 0.0026 +/- 0.0000 rms: 0.0000 +/- 0.0000
hostname:sdfmilan216 rank:076 cpu:075 cmt:v1o8 proc time (sec) mean: 0.0026 +/- 0.0001 rms: 0.0001 +/- 0.0001
hostname:sdfmilan216 rank:077 cpu:092 cmt:v1o8 proc time (sec) mean: 0.0026 +/- 0.0001 rms: 0.0001 +/- 0.0000
hostname:sdfmilan216 rank:078 cpu:106 cmt:v1o8 proc time (sec) mean: 0.0027 +/- 0.0001 rms: 0.0001 +/- 0.0000
hostname:sdfmilan216 rank:079 cpu:123 cmt:v1o8 proc time (sec) mean: 0.0027 +/- 0.0001 rms: 0.0001 +/- 0.0001
mean time (sec): 0.0026


sys.argv: ['Detector/examples/test-scaling-mpi.py', '-99']
selector for mode: -99



sort_records_in_file: figs/fig-mpi-rand-v2o1-sdfmilan216-ncores80-summary.txt
records:
means: shape:(80,) size:80 dtype:float64
[0.1102 0.0484 0.0522 0.0513 0.0985 0.1106 0.1426 0.1446 0.119  0.0487
 0.0542 0.0513 0.1063 0.1047 0.135  0.1386 0.1202 0.0487 0.0539 0.0508
 0.1037 0.1091 0.1403 0.1337 0.1182 0.0489 0.0524 0.0529 0.1025 0.108
 0.1417 0.1344 0.1242 0.0487 0.0514 0.0512 0.1068 0.1077 0.1464 0.1394
 0.1221 0.0485 0.0537 0.0514 0.1067 0.1117 0.1399 0.1289 0.1164 0.0482
 0.0543 0.0529 0.1039 0.1091 0.1386 0.1396 0.112  0.0488 0.0531 0.0515
 0.1053 0.1049 0.1362 0.1354 0.12   0.0514 0.0517 0.0517 0.1047 0.1099
 0.1375 0.1425 0.1166 0.052  0.053  0.0514 0.0987 0.1037 0.1409 0.1429]
mean time (sec): 0.0952

hostname:sdfmilan216 rank:000 cpu:014 cmt:v2o1 proc time (sec) mean: 0.1102 +/- 0.0132 rms: 0.0601 +/- 0.0093
hostname:sdfmilan216 rank:001 cpu:028 cmt:v2o1 proc time (sec) mean: 0.0484 +/- 0.0029 rms: 0.0048 +/- 0.0021
hostname:sdfmilan216 rank:002 cpu:047 cmt:v2o1 proc time (sec) mean: 0.0522 +/- 0.0038 rms: 0.0080 +/- 0.0027
hostname:sdfmilan216 rank:003 cpu:061 cmt:v2o1 proc time (sec) mean: 0.0513 +/- 0.0035 rms: 0.0068 +/- 0.0025
hostname:sdfmilan216 rank:004 cpu:078 cmt:v2o1 proc time (sec) mean: 0.0985 +/- 0.0127 rms: 0.0517 +/- 0.0090
hostname:sdfmilan216 rank:005 cpu:094 cmt:v2o1 proc time (sec) mean: 0.1106 +/- 0.0144 rms: 0.0609 +/- 0.0102
hostname:sdfmilan216 rank:006 cpu:098 cmt:v2o1 proc time (sec) mean: 0.1426 +/- 0.0358 rms: 0.1241 +/- 0.0253
hostname:sdfmilan216 rank:007 cpu:112 cmt:v2o1 proc time (sec) mean: 0.1446 +/- 0.0374 rms: 0.1269 +/- 0.0264
hostname:sdfmilan216 rank:008 cpu:006 cmt:v2o1 proc time (sec) mean: 0.1190 +/- 0.0141 rms: 0.0693 +/- 0.0100
hostname:sdfmilan216 rank:009 cpu:025 cmt:v2o1 proc time (sec) mean: 0.0487 +/- 0.0029 rms: 0.0048 +/- 0.0021
hostname:sdfmilan216 rank:010 cpu:043 cmt:v2o1 proc time (sec) mean: 0.0542 +/- 0.0042 rms: 0.0090 +/- 0.0029
hostname:sdfmilan216 rank:011 cpu:057 cmt:v2o1 proc time (sec) mean: 0.0513 +/- 0.0032 rms: 0.0062 +/- 0.0023
hostname:sdfmilan216 rank:012 cpu:070 cmt:v2o1 proc time (sec) mean: 0.1063 +/- 0.0119 rms: 0.0547 +/- 0.0084
hostname:sdfmilan216 rank:013 cpu:088 cmt:v2o1 proc time (sec) mean: 0.1047 +/- 0.0139 rms: 0.0596 +/- 0.0098
hostname:sdfmilan216 rank:014 cpu:107 cmt:v2o1 proc time (sec) mean: 0.1350 +/- 0.0331 rms: 0.1198 +/- 0.0234
hostname:sdfmilan216 rank:015 cpu:119 cmt:v2o1 proc time (sec) mean: 0.1386 +/- 0.0357 rms: 0.1211 +/- 0.0252
hostname:sdfmilan216 rank:016 cpu:012 cmt:v2o1 proc time (sec) mean: 0.1202 +/- 0.0153 rms: 0.0704 +/- 0.0108
hostname:sdfmilan216 rank:017 cpu:030 cmt:v2o1 proc time (sec) mean: 0.0487 +/- 0.0031 rms: 0.0052 +/- 0.0022
hostname:sdfmilan216 rank:018 cpu:032 cmt:v2o1 proc time (sec) mean: 0.0539 +/- 0.0040 rms: 0.0090 +/- 0.0028
hostname:sdfmilan216 rank:019 cpu:062 cmt:v2o1 proc time (sec) mean: 0.0508 +/- 0.0036 rms: 0.0067 +/- 0.0026
hostname:sdfmilan216 rank:020 cpu:066 cmt:v2o1 proc time (sec) mean: 0.1037 +/- 0.0128 rms: 0.0549 +/- 0.0090
hostname:sdfmilan216 rank:021 cpu:093 cmt:v2o1 proc time (sec) mean: 0.1091 +/- 0.0144 rms: 0.0604 +/- 0.0102
hostname:sdfmilan216 rank:022 cpu:096 cmt:v2o1 proc time (sec) mean: 0.1403 +/- 0.0356 rms: 0.1246 +/- 0.0252
hostname:sdfmilan216 rank:023 cpu:113 cmt:v2o1 proc time (sec) mean: 0.1337 +/- 0.0330 rms: 0.1144 +/- 0.0234
hostname:sdfmilan216 rank:024 cpu:009 cmt:v2o1 proc time (sec) mean: 0.1182 +/- 0.0138 rms: 0.0656 +/- 0.0097
hostname:sdfmilan216 rank:025 cpu:031 cmt:v2o1 proc time (sec) mean: 0.0489 +/- 0.0029 rms: 0.0050 +/- 0.0021
hostname:sdfmilan216 rank:026 cpu:039 cmt:v2o1 proc time (sec) mean: 0.0524 +/- 0.0043 rms: 0.0080 +/- 0.0030
hostname:sdfmilan216 rank:027 cpu:055 cmt:v2o1 proc time (sec) mean: 0.0529 +/- 0.0039 rms: 0.0078 +/- 0.0028
hostname:sdfmilan216 rank:028 cpu:076 cmt:v2o1 proc time (sec) mean: 0.1025 +/- 0.0117 rms: 0.0508 +/- 0.0082
hostname:sdfmilan216 rank:029 cpu:095 cmt:v2o1 proc time (sec) mean: 0.1080 +/- 0.0131 rms: 0.0561 +/- 0.0093
hostname:sdfmilan216 rank:030 cpu:110 cmt:v2o1 proc time (sec) mean: 0.1417 +/- 0.0352 rms: 0.1260 +/- 0.0249
hostname:sdfmilan216 rank:031 cpu:115 cmt:v2o1 proc time (sec) mean: 0.1344 +/- 0.0302 rms: 0.1093 +/- 0.0213
hostname:sdfmilan216 rank:032 cpu:005 cmt:v2o1 proc time (sec) mean: 0.1242 +/- 0.0157 rms: 0.0737 +/- 0.0111
hostname:sdfmilan216 rank:033 cpu:024 cmt:v2o1 proc time (sec) mean: 0.0487 +/- 0.0030 rms: 0.0051 +/- 0.0021
hostname:sdfmilan216 rank:034 cpu:036 cmt:v2o1 proc time (sec) mean: 0.0514 +/- 0.0033 rms: 0.0068 +/- 0.0024
hostname:sdfmilan216 rank:035 cpu:054 cmt:v2o1 proc time (sec) mean: 0.0512 +/- 0.0037 rms: 0.0068 +/- 0.0026
hostname:sdfmilan216 rank:036 cpu:067 cmt:v2o1 proc time (sec) mean: 0.1068 +/- 0.0117 rms: 0.0547 +/- 0.0083
hostname:sdfmilan216 rank:037 cpu:090 cmt:v2o1 proc time (sec) mean: 0.1077 +/- 0.0135 rms: 0.0586 +/- 0.0095
hostname:sdfmilan216 rank:038 cpu:101 cmt:v2o1 proc time (sec) mean: 0.1464 +/- 0.0420 rms: 0.1316 +/- 0.0297
hostname:sdfmilan216 rank:039 cpu:124 cmt:v2o1 proc time (sec) mean: 0.1394 +/- 0.0336 rms: 0.1185 +/- 0.0238
hostname:sdfmilan216 rank:040 cpu:010 cmt:v2o1 proc time (sec) mean: 0.1221 +/- 0.0141 rms: 0.0680 +/- 0.0100
hostname:sdfmilan216 rank:041 cpu:029 cmt:v2o1 proc time (sec) mean: 0.0485 +/- 0.0028 rms: 0.0045 +/- 0.0020
hostname:sdfmilan216 rank:042 cpu:037 cmt:v2o1 proc time (sec) mean: 0.0537 +/- 0.0042 rms: 0.0090 +/- 0.0030
hostname:sdfmilan216 rank:043 cpu:048 cmt:v2o1 proc time (sec) mean: 0.0514 +/- 0.0037 rms: 0.0071 +/- 0.0026
hostname:sdfmilan216 rank:044 cpu:077 cmt:v2o1 proc time (sec) mean: 0.1067 +/- 0.0122 rms: 0.0547 +/- 0.0086
hostname:sdfmilan216 rank:045 cpu:092 cmt:v2o1 proc time (sec) mean: 0.1117 +/- 0.0140 rms: 0.0612 +/- 0.0099
hostname:sdfmilan216 rank:046 cpu:099 cmt:v2o1 proc time (sec) mean: 0.1399 +/- 0.0419 rms: 0.1269 +/- 0.0296
hostname:sdfmilan216 rank:047 cpu:126 cmt:v2o1 proc time (sec) mean: 0.1289 +/- 0.0333 rms: 0.1104 +/- 0.0236
hostname:sdfmilan216 rank:048 cpu:015 cmt:v2o1 proc time (sec) mean: 0.1164 +/- 0.0143 rms: 0.0656 +/- 0.0101
hostname:sdfmilan216 rank:049 cpu:027 cmt:v2o1 proc time (sec) mean: 0.0482 +/- 0.0027 rms: 0.0044 +/- 0.0019
hostname:sdfmilan216 rank:050 cpu:034 cmt:v2o1 proc time (sec) mean: 0.0543 +/- 0.0041 rms: 0.0089 +/- 0.0029
hostname:sdfmilan216 rank:051 cpu:063 cmt:v2o1 proc time (sec) mean: 0.0529 +/- 0.0039 rms: 0.0086 +/- 0.0027
hostname:sdfmilan216 rank:052 cpu:073 cmt:v2o1 proc time (sec) mean: 0.1039 +/- 0.0111 rms: 0.0495 +/- 0.0078
hostname:sdfmilan216 rank:053 cpu:084 cmt:v2o1 proc time (sec) mean: 0.1091 +/- 0.0136 rms: 0.0596 +/- 0.0096
hostname:sdfmilan216 rank:054 cpu:097 cmt:v2o1 proc time (sec) mean: 0.1386 +/- 0.0365 rms: 0.1231 +/- 0.0258
hostname:sdfmilan216 rank:055 cpu:125 cmt:v2o1 proc time (sec) mean: 0.1396 +/- 0.0341 rms: 0.1179 +/- 0.0241
hostname:sdfmilan216 rank:056 cpu:009 cmt:v2o1 proc time (sec) mean: 0.1120 +/- 0.0125 rms: 0.0629 +/- 0.0089
hostname:sdfmilan216 rank:057 cpu:026 cmt:v2o1 proc time (sec) mean: 0.0488 +/- 0.0026 rms: 0.0045 +/- 0.0018
hostname:sdfmilan216 rank:058 cpu:035 cmt:v2o1 proc time (sec) mean: 0.0531 +/- 0.0040 rms: 0.0078 +/- 0.0028
hostname:sdfmilan216 rank:059 cpu:050 cmt:v2o1 proc time (sec) mean: 0.0515 +/- 0.0036 rms: 0.0073 +/- 0.0026
hostname:sdfmilan216 rank:060 cpu:065 cmt:v2o1 proc time (sec) mean: 0.1053 +/- 0.0137 rms: 0.0565 +/- 0.0097
hostname:sdfmilan216 rank:061 cpu:081 cmt:v2o1 proc time (sec) mean: 0.1049 +/- 0.0138 rms: 0.0558 +/- 0.0098
hostname:sdfmilan216 rank:062 cpu:096 cmt:v2o1 proc time (sec) mean: 0.1362 +/- 0.0421 rms: 0.1233 +/- 0.0298
hostname:sdfmilan216 rank:063 cpu:112 cmt:v2o1 proc time (sec) mean: 0.1354 +/- 0.0406 rms: 0.1166 +/- 0.0287
hostname:sdfmilan216 rank:064 cpu:008 cmt:v2o1 proc time (sec) mean: 0.1200 +/- 0.0147 rms: 0.0693 +/- 0.0104
hostname:sdfmilan216 rank:065 cpu:033 cmt:v2o1 proc time (sec) mean: 0.0514 +/- 0.0044 rms: 0.0075 +/- 0.0031
hostname:sdfmilan216 rank:066 cpu:038 cmt:v2o1 proc time (sec) mean: 0.0517 +/- 0.0037 rms: 0.0072 +/- 0.0026
hostname:sdfmilan216 rank:067 cpu:060 cmt:v2o1 proc time (sec) mean: 0.0517 +/- 0.0036 rms: 0.0072 +/- 0.0025
hostname:sdfmilan216 rank:068 cpu:069 cmt:v2o1 proc time (sec) mean: 0.1047 +/- 0.0117 rms: 0.0529 +/- 0.0083
hostname:sdfmilan216 rank:069 cpu:083 cmt:v2o1 proc time (sec) mean: 0.1099 +/- 0.0142 rms: 0.0610 +/- 0.0100
hostname:sdfmilan216 rank:070 cpu:111 cmt:v2o1 proc time (sec) mean: 0.1375 +/- 0.0353 rms: 0.1242 +/- 0.0250
hostname:sdfmilan216 rank:071 cpu:127 cmt:v2o1 proc time (sec) mean: 0.1425 +/- 0.0341 rms: 0.1257 +/- 0.0241
hostname:sdfmilan216 rank:072 cpu:007 cmt:v2o1 proc time (sec) mean: 0.1166 +/- 0.0147 rms: 0.0681 +/- 0.0104
hostname:sdfmilan216 rank:073 cpu:045 cmt:v2o1 proc time (sec) mean: 0.0520 +/- 0.0036 rms: 0.0072 +/- 0.0025
hostname:sdfmilan216 rank:074 cpu:044 cmt:v2o1 proc time (sec) mean: 0.0530 +/- 0.0045 rms: 0.0094 +/- 0.0032
hostname:sdfmilan216 rank:075 cpu:056 cmt:v2o1 proc time (sec) mean: 0.0514 +/- 0.0036 rms: 0.0069 +/- 0.0025
hostname:sdfmilan216 rank:076 cpu:074 cmt:v2o1 proc time (sec) mean: 0.0987 +/- 0.0120 rms: 0.0497 +/- 0.0085
hostname:sdfmilan216 rank:077 cpu:086 cmt:v2o1 proc time (sec) mean: 0.1037 +/- 0.0125 rms: 0.0532 +/- 0.0088
hostname:sdfmilan216 rank:078 cpu:108 cmt:v2o1 proc time (sec) mean: 0.1409 +/- 0.0369 rms: 0.1270 +/- 0.0261
hostname:sdfmilan216 rank:079 cpu:118 cmt:v2o1 proc time (sec) mean: 0.1429 +/- 0.0330 rms: 0.1210 +/- 0.0233
mean time (sec): 0.0952



sort_records_in_file: figs/fig-mpi-rand-v4o1-sdfmilan216-ncores80-summary.txt
records:
means: shape:(80,) size:80 dtype:float64
[0.2197 0.1026 0.1245 0.1014 0.1945 0.2146 0.3046 0.2956 0.2189 0.1006
 0.1216 0.1053 0.2043 0.2251 0.2934 0.293  0.2252 0.1001 0.1218 0.1029
 0.2037 0.2218 0.3099 0.2932 0.2248 0.1022 0.122  0.1012 0.2224 0.2191
 0.3149 0.2916 0.2231 0.1009 0.122  0.1052 0.2281 0.2177 0.3013 0.2864
 0.223  0.1013 0.1198 0.1053 0.215  0.2106 0.3087 0.3034 0.2156 0.1011
 0.1226 0.1035 0.204  0.2299 0.3076 0.2901 0.2074 0.1021 0.1249 0.1034
 0.2077 0.211  0.2926 0.2939 0.229  0.1243 0.1205 0.1047 0.2204 0.2105
 0.327  0.2747 0.2145 0.1205 0.1227 0.1077 0.1945 0.2211 0.2951 0.309 ]
mean time (sec): 0.1973

hostname:sdfmilan216 rank:000 cpu:005 cmt:v4o1 proc time (sec) mean: 0.2197 +/- 0.0160 rms: 0.1025 +/- 0.0113
hostname:sdfmilan216 rank:001 cpu:031 cmt:v4o1 proc time (sec) mean: 0.1026 +/- 0.0039 rms: 0.0100 +/- 0.0027
hostname:sdfmilan216 rank:002 cpu:040 cmt:v4o1 proc time (sec) mean: 0.1245 +/- 0.0057 rms: 0.0205 +/- 0.0040
hostname:sdfmilan216 rank:003 cpu:056 cmt:v4o1 proc time (sec) mean: 0.1014 +/- 0.0052 rms: 0.0129 +/- 0.0037
hostname:sdfmilan216 rank:004 cpu:071 cmt:v4o1 proc time (sec) mean: 0.1945 +/- 0.0150 rms: 0.0839 +/- 0.0106
hostname:sdfmilan216 rank:005 cpu:083 cmt:v4o1 proc time (sec) mean: 0.2146 +/- 0.0163 rms: 0.0994 +/- 0.0116
hostname:sdfmilan216 rank:006 cpu:102 cmt:v4o1 proc time (sec) mean: 0.3046 +/- 0.0936 rms: 0.2687 +/- 0.0662
hostname:sdfmilan216 rank:007 cpu:114 cmt:v4o1 proc time (sec) mean: 0.2956 +/- 0.0786 rms: 0.2443 +/- 0.0555
hostname:sdfmilan216 rank:008 cpu:008 cmt:v4o1 proc time (sec) mean: 0.2189 +/- 0.0181 rms: 0.1010 +/- 0.0128
hostname:sdfmilan216 rank:009 cpu:030 cmt:v4o1 proc time (sec) mean: 0.1006 +/- 0.0043 rms: 0.0099 +/- 0.0030
hostname:sdfmilan216 rank:010 cpu:039 cmt:v4o1 proc time (sec) mean: 0.1216 +/- 0.0055 rms: 0.0189 +/- 0.0039
hostname:sdfmilan216 rank:011 cpu:053 cmt:v4o1 proc time (sec) mean: 0.1053 +/- 0.0061 rms: 0.0173 +/- 0.0043
hostname:sdfmilan216 rank:012 cpu:066 cmt:v4o1 proc time (sec) mean: 0.2043 +/- 0.0153 rms: 0.0884 +/- 0.0108
hostname:sdfmilan216 rank:013 cpu:084 cmt:v4o1 proc time (sec) mean: 0.2251 +/- 0.0167 rms: 0.1053 +/- 0.0118
hostname:sdfmilan216 rank:014 cpu:100 cmt:v4o1 proc time (sec) mean: 0.2934 +/- 0.0837 rms: 0.2492 +/- 0.0592
hostname:sdfmilan216 rank:015 cpu:124 cmt:v4o1 proc time (sec) mean: 0.2930 +/- 0.0797 rms: 0.2524 +/- 0.0564
hostname:sdfmilan216 rank:016 cpu:012 cmt:v4o1 proc time (sec) mean: 0.2252 +/- 0.0164 rms: 0.1054 +/- 0.0116
hostname:sdfmilan216 rank:017 cpu:028 cmt:v4o1 proc time (sec) mean: 0.1001 +/- 0.0037 rms: 0.0087 +/- 0.0026
hostname:sdfmilan216 rank:018 cpu:041 cmt:v4o1 proc time (sec) mean: 0.1218 +/- 0.0055 rms: 0.0185 +/- 0.0039
hostname:sdfmilan216 rank:019 cpu:061 cmt:v4o1 proc time (sec) mean: 0.1029 +/- 0.0059 rms: 0.0176 +/- 0.0042
hostname:sdfmilan216 rank:020 cpu:068 cmt:v4o1 proc time (sec) mean: 0.2037 +/- 0.0162 rms: 0.0899 +/- 0.0114
hostname:sdfmilan216 rank:021 cpu:086 cmt:v4o1 proc time (sec) mean: 0.2218 +/- 0.0165 rms: 0.1081 +/- 0.0117
hostname:sdfmilan216 rank:022 cpu:111 cmt:v4o1 proc time (sec) mean: 0.3099 +/- 0.0933 rms: 0.2838 +/- 0.0660
hostname:sdfmilan216 rank:023 cpu:120 cmt:v4o1 proc time (sec) mean: 0.2932 +/- 0.0755 rms: 0.2514 +/- 0.0534
hostname:sdfmilan216 rank:024 cpu:000 cmt:v4o1 proc time (sec) mean: 0.2248 +/- 0.0158 rms: 0.0994 +/- 0.0112
hostname:sdfmilan216 rank:025 cpu:024 cmt:v4o1 proc time (sec) mean: 0.1022 +/- 0.0043 rms: 0.0110 +/- 0.0030
hostname:sdfmilan216 rank:026 cpu:040 cmt:v4o1 proc time (sec) mean: 0.1220 +/- 0.0056 rms: 0.0204 +/- 0.0040
hostname:sdfmilan216 rank:027 cpu:062 cmt:v4o1 proc time (sec) mean: 0.1012 +/- 0.0051 rms: 0.0130 +/- 0.0036
hostname:sdfmilan216 rank:028 cpu:064 cmt:v4o1 proc time (sec) mean: 0.2224 +/- 0.0172 rms: 0.1064 +/- 0.0122
hostname:sdfmilan216 rank:029 cpu:095 cmt:v4o1 proc time (sec) mean: 0.2191 +/- 0.0191 rms: 0.1119 +/- 0.0135
hostname:sdfmilan216 rank:030 cpu:098 cmt:v4o1 proc time (sec) mean: 0.3149 +/- 0.0881 rms: 0.2740 +/- 0.0623
hostname:sdfmilan216 rank:031 cpu:116 cmt:v4o1 proc time (sec) mean: 0.2916 +/- 0.0904 rms: 0.2509 +/- 0.0639
hostname:sdfmilan216 rank:032 cpu:015 cmt:v4o1 proc time (sec) mean: 0.2231 +/- 0.0154 rms: 0.0983 +/- 0.0109
hostname:sdfmilan216 rank:033 cpu:026 cmt:v4o1 proc time (sec) mean: 0.1009 +/- 0.0038 rms: 0.0090 +/- 0.0027
hostname:sdfmilan216 rank:034 cpu:033 cmt:v4o1 proc time (sec) mean: 0.1220 +/- 0.0054 rms: 0.0190 +/- 0.0038
hostname:sdfmilan216 rank:035 cpu:052 cmt:v4o1 proc time (sec) mean: 0.1052 +/- 0.0057 rms: 0.0176 +/- 0.0041
hostname:sdfmilan216 rank:036 cpu:078 cmt:v4o1 proc time (sec) mean: 0.2281 +/- 0.0180 rms: 0.1093 +/- 0.0127
hostname:sdfmilan216 rank:037 cpu:092 cmt:v4o1 proc time (sec) mean: 0.2177 +/- 0.0166 rms: 0.1060 +/- 0.0118
hostname:sdfmilan216 rank:038 cpu:106 cmt:v4o1 proc time (sec) mean: 0.3013 +/- 0.0883 rms: 0.2581 +/- 0.0624
hostname:sdfmilan216 rank:039 cpu:119 cmt:v4o1 proc time (sec) mean: 0.2864 +/- 0.0853 rms: 0.2323 +/- 0.0604
hostname:sdfmilan216 rank:040 cpu:006 cmt:v4o1 proc time (sec) mean: 0.2230 +/- 0.0159 rms: 0.1055 +/- 0.0112
hostname:sdfmilan216 rank:041 cpu:029 cmt:v4o1 proc time (sec) mean: 0.1013 +/- 0.0039 rms: 0.0095 +/- 0.0027
hostname:sdfmilan216 rank:042 cpu:040 cmt:v4o1 proc time (sec) mean: 0.1198 +/- 0.0049 rms: 0.0161 +/- 0.0035
hostname:sdfmilan216 rank:043 cpu:063 cmt:v4o1 proc time (sec) mean: 0.1053 +/- 0.0053 rms: 0.0145 +/- 0.0037
hostname:sdfmilan216 rank:044 cpu:065 cmt:v4o1 proc time (sec) mean: 0.2150 +/- 0.0156 rms: 0.0972 +/- 0.0110
hostname:sdfmilan216 rank:045 cpu:087 cmt:v4o1 proc time (sec) mean: 0.2106 +/- 0.0172 rms: 0.1026 +/- 0.0122
hostname:sdfmilan216 rank:046 cpu:096 cmt:v4o1 proc time (sec) mean: 0.3087 +/- 0.0960 rms: 0.2850 +/- 0.0679
hostname:sdfmilan216 rank:047 cpu:112 cmt:v4o1 proc time (sec) mean: 0.3034 +/- 0.0861 rms: 0.2567 +/- 0.0609
hostname:sdfmilan216 rank:048 cpu:007 cmt:v4o1 proc time (sec) mean: 0.2156 +/- 0.0152 rms: 0.0940 +/- 0.0107
hostname:sdfmilan216 rank:049 cpu:025 cmt:v4o1 proc time (sec) mean: 0.1011 +/- 0.0037 rms: 0.0091 +/- 0.0027
hostname:sdfmilan216 rank:050 cpu:038 cmt:v4o1 proc time (sec) mean: 0.1226 +/- 0.0058 rms: 0.0201 +/- 0.0041
hostname:sdfmilan216 rank:051 cpu:056 cmt:v4o1 proc time (sec) mean: 0.1035 +/- 0.0054 rms: 0.0145 +/- 0.0038
hostname:sdfmilan216 rank:052 cpu:070 cmt:v4o1 proc time (sec) mean: 0.2040 +/- 0.0155 rms: 0.0920 +/- 0.0110
hostname:sdfmilan216 rank:053 cpu:081 cmt:v4o1 proc time (sec) mean: 0.2299 +/- 0.0193 rms: 0.1173 +/- 0.0136
hostname:sdfmilan216 rank:054 cpu:097 cmt:v4o1 proc time (sec) mean: 0.3076 +/- 0.1020 rms: 0.2759 +/- 0.0722
hostname:sdfmilan216 rank:055 cpu:113 cmt:v4o1 proc time (sec) mean: 0.2901 +/- 0.0893 rms: 0.2450 +/- 0.0632
hostname:sdfmilan216 rank:056 cpu:010 cmt:v4o1 proc time (sec) mean: 0.2074 +/- 0.0154 rms: 0.0969 +/- 0.0109
hostname:sdfmilan216 rank:057 cpu:027 cmt:v4o1 proc time (sec) mean: 0.1021 +/- 0.0044 rms: 0.0111 +/- 0.0031
hostname:sdfmilan216 rank:058 cpu:045 cmt:v4o1 proc time (sec) mean: 0.1249 +/- 0.0059 rms: 0.0204 +/- 0.0042
hostname:sdfmilan216 rank:059 cpu:060 cmt:v4o1 proc time (sec) mean: 0.1034 +/- 0.0053 rms: 0.0143 +/- 0.0038
hostname:sdfmilan216 rank:060 cpu:076 cmt:v4o1 proc time (sec) mean: 0.2077 +/- 0.0150 rms: 0.0916 +/- 0.0106
hostname:sdfmilan216 rank:061 cpu:085 cmt:v4o1 proc time (sec) mean: 0.2110 +/- 0.0159 rms: 0.0885 +/- 0.0112
hostname:sdfmilan216 rank:062 cpu:096 cmt:v4o1 proc time (sec) mean: 0.2926 +/- 0.0843 rms: 0.2550 +/- 0.0596
hostname:sdfmilan216 rank:063 cpu:115 cmt:v4o1 proc time (sec) mean: 0.2939 +/- 0.0909 rms: 0.2588 +/- 0.0642
hostname:sdfmilan216 rank:064 cpu:009 cmt:v4o1 proc time (sec) mean: 0.2290 +/- 0.0164 rms: 0.1002 +/- 0.0116
hostname:sdfmilan216 rank:065 cpu:047 cmt:v4o1 proc time (sec) mean: 0.1243 +/- 0.0058 rms: 0.0202 +/- 0.0041
hostname:sdfmilan216 rank:066 cpu:042 cmt:v4o1 proc time (sec) mean: 0.1205 +/- 0.0057 rms: 0.0185 +/- 0.0040
hostname:sdfmilan216 rank:067 cpu:051 cmt:v4o1 proc time (sec) mean: 0.1047 +/- 0.0056 rms: 0.0159 +/- 0.0040
hostname:sdfmilan216 rank:068 cpu:079 cmt:v4o1 proc time (sec) mean: 0.2204 +/- 0.0190 rms: 0.1071 +/- 0.0134
hostname:sdfmilan216 rank:069 cpu:091 cmt:v4o1 proc time (sec) mean: 0.2105 +/- 0.0167 rms: 0.0986 +/- 0.0118
hostname:sdfmilan216 rank:070 cpu:097 cmt:v4o1 proc time (sec) mean: 0.3270 +/- 0.1022 rms: 0.3020 +/- 0.0723
hostname:sdfmilan216 rank:071 cpu:127 cmt:v4o1 proc time (sec) mean: 0.2747 +/- 0.0916 rms: 0.2383 +/- 0.0647
hostname:sdfmilan216 rank:072 cpu:013 cmt:v4o1 proc time (sec) mean: 0.2145 +/- 0.0167 rms: 0.1017 +/- 0.0118
hostname:sdfmilan216 rank:073 cpu:037 cmt:v4o1 proc time (sec) mean: 0.1205 +/- 0.0055 rms: 0.0185 +/- 0.0039
hostname:sdfmilan216 rank:074 cpu:044 cmt:v4o1 proc time (sec) mean: 0.1227 +/- 0.0062 rms: 0.0217 +/- 0.0044
hostname:sdfmilan216 rank:075 cpu:057 cmt:v4o1 proc time (sec) mean: 0.1077 +/- 0.0061 rms: 0.0186 +/- 0.0043
hostname:sdfmilan216 rank:076 cpu:072 cmt:v4o1 proc time (sec) mean: 0.1945 +/- 0.0150 rms: 0.0837 +/- 0.0106
hostname:sdfmilan216 rank:077 cpu:080 cmt:v4o1 proc time (sec) mean: 0.2211 +/- 0.0173 rms: 0.1100 +/- 0.0122
hostname:sdfmilan216 rank:078 cpu:104 cmt:v4o1 proc time (sec) mean: 0.2951 +/- 0.0891 rms: 0.2527 +/- 0.0630
hostname:sdfmilan216 rank:079 cpu:125 cmt:v4o1 proc time (sec) mean: 0.3090 +/- 0.1009 rms: 0.2776 +/- 0.0714
mean time (sec): 0.1973
 

Summary

time per-event per-core, ms

panel sizesingle core80-coreR 80/1
4: (4*512, 1024)73.8197.32.67
2: (2*512, 1024)37.395.22.55
1: (512, 1024)18.442.32.3
1/2: (256, 1024)9.210.61.15
1/4: (128, 1024)4.55.31.17
1/8: (64, 1024)2.22.61.18

2024-02-28 new algorithm of calib_jungfrau_v2

Description

Local cache is done for arrays of calibration constants which are absolutely necessary

pedestals + offset constants are used in a single array in cache

indexed operations are dropped at gain range selection in favor of np.select 

Results

 Old algorithm calib_jungfrau

Timing results for old algorithm calib_jungfrau
sys.argv: ['Detector/examples/test-scaling-mpi.py', '-99']
selector for mode: -99



sort_records_in_file: figs/fig-mpi-data-1p-v3-sdfmilan231-ncores01-summary.txt
records:
means: shape:(4,) size:4 dtype:float64
[0.044  0.044  0.0441 0.0441]
mean time (sec): 0.0440

hostname:sdfmilan231 rank:000 cpu:000 cmt:1p-v3 proc time (sec) mean: 0.0440 +/- 0.0008 rms: 0.0009 +/- 0.0006
hostname:sdfmilan231 rank:000 cpu:000 cmt:1p-v3 proc time (sec) mean: 0.0440 +/- 0.0010 rms: 0.0011 +/- 0.0007
hostname:sdfmilan231 rank:000 cpu:000 cmt:1p-v3 proc time (sec) mean: 0.0441 +/- 0.0009 rms: 0.0010 +/- 0.0007
hostname:sdfmilan231 rank:000 cpu:000 cmt:1p-v3 proc time (sec) mean: 0.0441 +/- 0.0010 rms: 0.0011 +/- 0.0007
mean time (sec): 0.0440



sort_records_in_file: figs/fig-mpi-data-1p-v3-sdfmilan231-ncores80-summary.txt
records:
means: shape:(80,) size:80 dtype:float64
[0.0612 0.0645 0.0623 0.0578 0.074  0.0701 0.0598 0.0613 0.0615 0.066
 0.062  0.059  0.0764 0.0717 0.0635 0.0606 0.0615 0.0662 0.06   0.0575
 0.0731 0.068  0.057  0.0608 0.0606 0.0616 0.0626 0.0576 0.0721 0.0697
 0.0624 0.0617 0.0611 0.0648 0.0625 0.0583 0.0747 0.0703 0.0647 0.0619
 0.06   0.0657 0.0598 0.059  0.0714 0.0693 0.0656 0.0626 0.0611 0.0663
 0.0593 0.0571 0.0741 0.0701 0.0616 0.0615 0.0624 0.0651 0.0604 0.0572
 0.0719 0.0708 0.0615 0.0559 0.0605 0.0609 0.0597 0.06   0.0714 0.0701
 0.0657 0.0616 0.0614 0.0596 0.062  0.0584 0.0699 0.0688 0.0592 0.0624]
mean time (sec): 0.0638

hostname:sdfmilan231 rank:000 cpu:008 cmt:1p-v3 proc time (sec) mean: 0.0612 +/- 0.0015 rms: 0.0027 +/- 0.0011
hostname:sdfmilan231 rank:001 cpu:024 cmt:1p-v3 proc time (sec) mean: 0.0645 +/- 0.0021 rms: 0.0053 +/- 0.0015
hostname:sdfmilan231 rank:002 cpu:043 cmt:1p-v3 proc time (sec) mean: 0.0623 +/- 0.0018 rms: 0.0036 +/- 0.0013
hostname:sdfmilan231 rank:003 cpu:062 cmt:1p-v3 proc time (sec) mean: 0.0578 +/- 0.0012 rms: 0.0019 +/- 0.0008
hostname:sdfmilan231 rank:004 cpu:074 cmt:1p-v3 proc time (sec) mean: 0.0740 +/- 0.0032 rms: 0.0122 +/- 0.0023
hostname:sdfmilan231 rank:005 cpu:081 cmt:1p-v3 proc time (sec) mean: 0.0701 +/- 0.0034 rms: 0.0118 +/- 0.0024
hostname:sdfmilan231 rank:006 cpu:109 cmt:1p-v3 proc time (sec) mean: 0.0598 +/- 0.0021 rms: 0.0056 +/- 0.0015
hostname:sdfmilan231 rank:007 cpu:126 cmt:1p-v3 proc time (sec) mean: 0.0613 +/- 0.0021 rms: 0.0056 +/- 0.0015
hostname:sdfmilan231 rank:008 cpu:006 cmt:1p-v3 proc time (sec) mean: 0.0615 +/- 0.0015 rms: 0.0029 +/- 0.0011
hostname:sdfmilan231 rank:009 cpu:026 cmt:1p-v3 proc time (sec) mean: 0.0660 +/- 0.0022 rms: 0.0059 +/- 0.0016
hostname:sdfmilan231 rank:010 cpu:045 cmt:1p-v3 proc time (sec) mean: 0.0620 +/- 0.0017 rms: 0.0032 +/- 0.0012
hostname:sdfmilan231 rank:011 cpu:063 cmt:1p-v3 proc time (sec) mean: 0.0590 +/- 0.0013 rms: 0.0022 +/- 0.0009
hostname:sdfmilan231 rank:012 cpu:069 cmt:1p-v3 proc time (sec) mean: 0.0764 +/- 0.0033 rms: 0.0130 +/- 0.0023
hostname:sdfmilan231 rank:013 cpu:086 cmt:1p-v3 proc time (sec) mean: 0.0717 +/- 0.0035 rms: 0.0122 +/- 0.0024
hostname:sdfmilan231 rank:014 cpu:101 cmt:1p-v3 proc time (sec) mean: 0.0635 +/- 0.0023 rms: 0.0061 +/- 0.0017
hostname:sdfmilan231 rank:015 cpu:114 cmt:1p-v3 proc time (sec) mean: 0.0606 +/- 0.0021 rms: 0.0050 +/- 0.0015
hostname:sdfmilan231 rank:016 cpu:001 cmt:1p-v3 proc time (sec) mean: 0.0615 +/- 0.0018 rms: 0.0037 +/- 0.0013
hostname:sdfmilan231 rank:017 cpu:031 cmt:1p-v3 proc time (sec) mean: 0.0662 +/- 0.0021 rms: 0.0050 +/- 0.0015
hostname:sdfmilan231 rank:018 cpu:036 cmt:1p-v3 proc time (sec) mean: 0.0600 +/- 0.0013 rms: 0.0023 +/- 0.0009
hostname:sdfmilan231 rank:019 cpu:059 cmt:1p-v3 proc time (sec) mean: 0.0575 +/- 0.0010 rms: 0.0015 +/- 0.0007
hostname:sdfmilan231 rank:020 cpu:068 cmt:1p-v3 proc time (sec) mean: 0.0731 +/- 0.0033 rms: 0.0125 +/- 0.0023
hostname:sdfmilan231 rank:021 cpu:092 cmt:1p-v3 proc time (sec) mean: 0.0680 +/- 0.0031 rms: 0.0114 +/- 0.0022
hostname:sdfmilan231 rank:022 cpu:104 cmt:1p-v3 proc time (sec) mean: 0.0570 +/- 0.0016 rms: 0.0031 +/- 0.0012
hostname:sdfmilan231 rank:023 cpu:124 cmt:1p-v3 proc time (sec) mean: 0.0608 +/- 0.0019 rms: 0.0047 +/- 0.0013
hostname:sdfmilan231 rank:024 cpu:014 cmt:1p-v3 proc time (sec) mean: 0.0606 +/- 0.0012 rms: 0.0021 +/- 0.0009
hostname:sdfmilan231 rank:025 cpu:030 cmt:1p-v3 proc time (sec) mean: 0.0616 +/- 0.0021 rms: 0.0048 +/- 0.0015
hostname:sdfmilan231 rank:026 cpu:046 cmt:1p-v3 proc time (sec) mean: 0.0626 +/- 0.0019 rms: 0.0039 +/- 0.0014
hostname:sdfmilan231 rank:027 cpu:055 cmt:1p-v3 proc time (sec) mean: 0.0576 +/- 0.0010 rms: 0.0014 +/- 0.0007
hostname:sdfmilan231 rank:028 cpu:077 cmt:1p-v3 proc time (sec) mean: 0.0721 +/- 0.0033 rms: 0.0120 +/- 0.0023
hostname:sdfmilan231 rank:029 cpu:081 cmt:1p-v3 proc time (sec) mean: 0.0697 +/- 0.0034 rms: 0.0121 +/- 0.0024
hostname:sdfmilan231 rank:030 cpu:104 cmt:1p-v3 proc time (sec) mean: 0.0624 +/- 0.0021 rms: 0.0057 +/- 0.0015
hostname:sdfmilan231 rank:031 cpu:123 cmt:1p-v3 proc time (sec) mean: 0.0617 +/- 0.0019 rms: 0.0047 +/- 0.0014
hostname:sdfmilan231 rank:032 cpu:002 cmt:1p-v3 proc time (sec) mean: 0.0611 +/- 0.0017 rms: 0.0032 +/- 0.0012
hostname:sdfmilan231 rank:033 cpu:029 cmt:1p-v3 proc time (sec) mean: 0.0648 +/- 0.0023 rms: 0.0051 +/- 0.0016
hostname:sdfmilan231 rank:034 cpu:041 cmt:1p-v3 proc time (sec) mean: 0.0625 +/- 0.0017 rms: 0.0037 +/- 0.0012
hostname:sdfmilan231 rank:035 cpu:050 cmt:1p-v3 proc time (sec) mean: 0.0583 +/- 0.0011 rms: 0.0016 +/- 0.0008
hostname:sdfmilan231 rank:036 cpu:070 cmt:1p-v3 proc time (sec) mean: 0.0747 +/- 0.0032 rms: 0.0122 +/- 0.0022
hostname:sdfmilan231 rank:037 cpu:085 cmt:1p-v3 proc time (sec) mean: 0.0703 +/- 0.0030 rms: 0.0106 +/- 0.0021
hostname:sdfmilan231 rank:038 cpu:105 cmt:1p-v3 proc time (sec) mean: 0.0647 +/- 0.0022 rms: 0.0064 +/- 0.0016
hostname:sdfmilan231 rank:039 cpu:116 cmt:1p-v3 proc time (sec) mean: 0.0619 +/- 0.0021 rms: 0.0060 +/- 0.0015
hostname:sdfmilan231 rank:040 cpu:015 cmt:1p-v3 proc time (sec) mean: 0.0600 +/- 0.0017 rms: 0.0031 +/- 0.0012
hostname:sdfmilan231 rank:041 cpu:027 cmt:1p-v3 proc time (sec) mean: 0.0657 +/- 0.0024 rms: 0.0066 +/- 0.0017
hostname:sdfmilan231 rank:042 cpu:035 cmt:1p-v3 proc time (sec) mean: 0.0598 +/- 0.0015 rms: 0.0028 +/- 0.0011
hostname:sdfmilan231 rank:043 cpu:056 cmt:1p-v3 proc time (sec) mean: 0.0590 +/- 0.0011 rms: 0.0016 +/- 0.0008
hostname:sdfmilan231 rank:044 cpu:065 cmt:1p-v3 proc time (sec) mean: 0.0714 +/- 0.0032 rms: 0.0114 +/- 0.0022
hostname:sdfmilan231 rank:045 cpu:080 cmt:1p-v3 proc time (sec) mean: 0.0693 +/- 0.0031 rms: 0.0115 +/- 0.0022
hostname:sdfmilan231 rank:046 cpu:102 cmt:1p-v3 proc time (sec) mean: 0.0656 +/- 0.0023 rms: 0.0071 +/- 0.0017
hostname:sdfmilan231 rank:047 cpu:121 cmt:1p-v3 proc time (sec) mean: 0.0626 +/- 0.0021 rms: 0.0059 +/- 0.0015
hostname:sdfmilan231 rank:048 cpu:007 cmt:1p-v3 proc time (sec) mean: 0.0611 +/- 0.0020 rms: 0.0038 +/- 0.0014
hostname:sdfmilan231 rank:049 cpu:028 cmt:1p-v3 proc time (sec) mean: 0.0663 +/- 0.0023 rms: 0.0056 +/- 0.0016
hostname:sdfmilan231 rank:050 cpu:037 cmt:1p-v3 proc time (sec) mean: 0.0593 +/- 0.0016 rms: 0.0028 +/- 0.0011
hostname:sdfmilan231 rank:051 cpu:052 cmt:1p-v3 proc time (sec) mean: 0.0571 +/- 0.0011 rms: 0.0015 +/- 0.0007
hostname:sdfmilan231 rank:052 cpu:079 cmt:1p-v3 proc time (sec) mean: 0.0741 +/- 0.0034 rms: 0.0123 +/- 0.0024
hostname:sdfmilan231 rank:053 cpu:090 cmt:1p-v3 proc time (sec) mean: 0.0701 +/- 0.0035 rms: 0.0124 +/- 0.0025
hostname:sdfmilan231 rank:054 cpu:111 cmt:1p-v3 proc time (sec) mean: 0.0616 +/- 0.0021 rms: 0.0051 +/- 0.0015
hostname:sdfmilan231 rank:055 cpu:120 cmt:1p-v3 proc time (sec) mean: 0.0615 +/- 0.0020 rms: 0.0051 +/- 0.0014
hostname:sdfmilan231 rank:056 cpu:004 cmt:1p-v3 proc time (sec) mean: 0.0624 +/- 0.0018 rms: 0.0036 +/- 0.0013
hostname:sdfmilan231 rank:057 cpu:027 cmt:1p-v3 proc time (sec) mean: 0.0651 +/- 0.0024 rms: 0.0061 +/- 0.0017
hostname:sdfmilan231 rank:058 cpu:033 cmt:1p-v3 proc time (sec) mean: 0.0604 +/- 0.0016 rms: 0.0029 +/- 0.0011
hostname:sdfmilan231 rank:059 cpu:051 cmt:1p-v3 proc time (sec) mean: 0.0572 +/- 0.0013 rms: 0.0018 +/- 0.0009
hostname:sdfmilan231 rank:060 cpu:071 cmt:1p-v3 proc time (sec) mean: 0.0719 +/- 0.0033 rms: 0.0125 +/- 0.0023
hostname:sdfmilan231 rank:061 cpu:084 cmt:1p-v3 proc time (sec) mean: 0.0708 +/- 0.0036 rms: 0.0126 +/- 0.0026
hostname:sdfmilan231 rank:062 cpu:107 cmt:1p-v3 proc time (sec) mean: 0.0615 +/- 0.0020 rms: 0.0054 +/- 0.0014
hostname:sdfmilan231 rank:063 cpu:119 cmt:1p-v3 proc time (sec) mean: 0.0559 +/- 0.0016 rms: 0.0027 +/- 0.0011
hostname:sdfmilan231 rank:064 cpu:009 cmt:1p-v3 proc time (sec) mean: 0.0605 +/- 0.0015 rms: 0.0028 +/- 0.0011
hostname:sdfmilan231 rank:065 cpu:042 cmt:1p-v3 proc time (sec) mean: 0.0609 +/- 0.0021 rms: 0.0038 +/- 0.0015
hostname:sdfmilan231 rank:066 cpu:034 cmt:1p-v3 proc time (sec) mean: 0.0597 +/- 0.0014 rms: 0.0023 +/- 0.0010
hostname:sdfmilan231 rank:067 cpu:057 cmt:1p-v3 proc time (sec) mean: 0.0600 +/- 0.0012 rms: 0.0021 +/- 0.0009
hostname:sdfmilan231 rank:068 cpu:073 cmt:1p-v3 proc time (sec) mean: 0.0714 +/- 0.0033 rms: 0.0117 +/- 0.0023
hostname:sdfmilan231 rank:069 cpu:091 cmt:1p-v3 proc time (sec) mean: 0.0701 +/- 0.0037 rms: 0.0132 +/- 0.0026
hostname:sdfmilan231 rank:070 cpu:099 cmt:1p-v3 proc time (sec) mean: 0.0657 +/- 0.0023 rms: 0.0067 +/- 0.0016
hostname:sdfmilan231 rank:071 cpu:125 cmt:1p-v3 proc time (sec) mean: 0.0616 +/- 0.0021 rms: 0.0058 +/- 0.0015
hostname:sdfmilan231 rank:072 cpu:013 cmt:1p-v3 proc time (sec) mean: 0.0614 +/- 0.0018 rms: 0.0035 +/- 0.0013
hostname:sdfmilan231 rank:073 cpu:032 cmt:1p-v3 proc time (sec) mean: 0.0596 +/- 0.0016 rms: 0.0028 +/- 0.0012
hostname:sdfmilan231 rank:074 cpu:044 cmt:1p-v3 proc time (sec) mean: 0.0620 +/- 0.0021 rms: 0.0043 +/- 0.0015
hostname:sdfmilan231 rank:075 cpu:054 cmt:1p-v3 proc time (sec) mean: 0.0584 +/- 0.0011 rms: 0.0017 +/- 0.0008
hostname:sdfmilan231 rank:076 cpu:072 cmt:1p-v3 proc time (sec) mean: 0.0699 +/- 0.0031 rms: 0.0113 +/- 0.0022
hostname:sdfmilan231 rank:077 cpu:095 cmt:1p-v3 proc time (sec) mean: 0.0688 +/- 0.0034 rms: 0.0119 +/- 0.0024
hostname:sdfmilan231 rank:078 cpu:108 cmt:1p-v3 proc time (sec) mean: 0.0592 +/- 0.0018 rms: 0.0043 +/- 0.0013
hostname:sdfmilan231 rank:079 cpu:117 cmt:1p-v3 proc time (sec) mean: 0.0624 +/- 0.0021 rms: 0.0052 +/- 0.0015
mean time (sec): 0.0638

New algorithm calib_jungfrau_v2

Timing results for new algorithm calib_jungfrau_v2
sort_records_in_file: figs/fig-mpi-data-1p-v4-sdfmilan231-ncores01-summary.txt
records:
means: shape:(4,) size:4 dtype:float64
[0.0339 0.0339 0.0339 0.0339]
mean time (sec): 0.0339

hostname:sdfmilan231 rank:000 cpu:000 cmt:1p-v4 proc time (sec) mean: 0.0339 +/- 0.0005 rms: 0.0005 +/- 0.0003
hostname:sdfmilan231 rank:000 cpu:000 cmt:1p-v4 proc time (sec) mean: 0.0339 +/- 0.0006 rms: 0.0006 +/- 0.0004
hostname:sdfmilan231 rank:000 cpu:000 cmt:1p-v4 proc time (sec) mean: 0.0339 +/- 0.0006 rms: 0.0006 +/- 0.0004
hostname:sdfmilan231 rank:000 cpu:000 cmt:1p-v4 proc time (sec) mean: 0.0339 +/- 0.0006 rms: 0.0006 +/- 0.0004
mean time (sec): 0.0339



sort_records_in_file: figs/fig-mpi-data-1p-v4-sdfmilan231-ncores80-summary.txt
records:
means: shape:(80,) size:80 dtype:float64
[0.044  0.0449 0.0442 0.044  0.042  0.0437 0.0424 0.0416 0.044  0.0448
 0.044  0.0441 0.0427 0.0443 0.0418 0.0418 0.0443 0.0447 0.0441 0.044
 0.0432 0.0425 0.0424 0.0413 0.0442 0.045  0.0439 0.044  0.0421 0.0437
 0.0419 0.0414 0.044  0.0456 0.0441 0.0439 0.0435 0.0435 0.0419 0.0414
 0.0439 0.0443 0.0441 0.0439 0.0428 0.0421 0.042  0.0414 0.044  0.0448
 0.0442 0.0439 0.043  0.0428 0.0419 0.0415 0.0441 0.045  0.0439 0.044
 0.0427 0.0428 0.0415 0.0418 0.0444 0.044  0.0439 0.0439 0.0426 0.0438
 0.0416 0.0414 0.0438 0.0439 0.044  0.0439 0.0427 0.0432 0.0416 0.0414]
mean time (sec): 0.0433

hostname:sdfmilan231 rank:000 cpu:003 cmt:1p-v4 proc time (sec) mean: 0.0440 +/- 0.0011 rms: 0.0012 +/- 0.0007
hostname:sdfmilan231 rank:001 cpu:031 cmt:1p-v4 proc time (sec) mean: 0.0449 +/- 0.0023 rms: 0.0038 +/- 0.0016
hostname:sdfmilan231 rank:002 cpu:037 cmt:1p-v4 proc time (sec) mean: 0.0442 +/- 0.0012 rms: 0.0014 +/- 0.0008
hostname:sdfmilan231 rank:003 cpu:052 cmt:1p-v4 proc time (sec) mean: 0.0440 +/- 0.0011 rms: 0.0013 +/- 0.0008
hostname:sdfmilan231 rank:004 cpu:069 cmt:1p-v4 proc time (sec) mean: 0.0420 +/- 0.0010 rms: 0.0012 +/- 0.0007
hostname:sdfmilan231 rank:005 cpu:087 cmt:1p-v4 proc time (sec) mean: 0.0437 +/- 0.0015 rms: 0.0023 +/- 0.0011
hostname:sdfmilan231 rank:006 cpu:097 cmt:1p-v4 proc time (sec) mean: 0.0424 +/- 0.0010 rms: 0.0015 +/- 0.0007
hostname:sdfmilan231 rank:007 cpu:127 cmt:1p-v4 proc time (sec) mean: 0.0416 +/- 0.0009 rms: 0.0010 +/- 0.0006
hostname:sdfmilan231 rank:008 cpu:011 cmt:1p-v4 proc time (sec) mean: 0.0440 +/- 0.0010 rms: 0.0011 +/- 0.0007
hostname:sdfmilan231 rank:009 cpu:026 cmt:1p-v4 proc time (sec) mean: 0.0448 +/- 0.0021 rms: 0.0037 +/- 0.0015
hostname:sdfmilan231 rank:010 cpu:044 cmt:1p-v4 proc time (sec) mean: 0.0440 +/- 0.0009 rms: 0.0011 +/- 0.0007
hostname:sdfmilan231 rank:011 cpu:048 cmt:1p-v4 proc time (sec) mean: 0.0441 +/- 0.0009 rms: 0.0010 +/- 0.0006
hostname:sdfmilan231 rank:012 cpu:068 cmt:1p-v4 proc time (sec) mean: 0.0427 +/- 0.0012 rms: 0.0019 +/- 0.0008
hostname:sdfmilan231 rank:013 cpu:081 cmt:1p-v4 proc time (sec) mean: 0.0443 +/- 0.0015 rms: 0.0027 +/- 0.0011
hostname:sdfmilan231 rank:014 cpu:096 cmt:1p-v4 proc time (sec) mean: 0.0418 +/- 0.0010 rms: 0.0012 +/- 0.0007
hostname:sdfmilan231 rank:015 cpu:112 cmt:1p-v4 proc time (sec) mean: 0.0418 +/- 0.0012 rms: 0.0015 +/- 0.0008
hostname:sdfmilan231 rank:016 cpu:005 cmt:1p-v4 proc time (sec) mean: 0.0443 +/- 0.0010 rms: 0.0013 +/- 0.0007
hostname:sdfmilan231 rank:017 cpu:025 cmt:1p-v4 proc time (sec) mean: 0.0447 +/- 0.0016 rms: 0.0026 +/- 0.0011
hostname:sdfmilan231 rank:018 cpu:042 cmt:1p-v4 proc time (sec) mean: 0.0441 +/- 0.0008 rms: 0.0010 +/- 0.0006
hostname:sdfmilan231 rank:019 cpu:060 cmt:1p-v4 proc time (sec) mean: 0.0440 +/- 0.0009 rms: 0.0010 +/- 0.0006
hostname:sdfmilan231 rank:020 cpu:077 cmt:1p-v4 proc time (sec) mean: 0.0432 +/- 0.0011 rms: 0.0017 +/- 0.0008
hostname:sdfmilan231 rank:021 cpu:080 cmt:1p-v4 proc time (sec) mean: 0.0425 +/- 0.0011 rms: 0.0016 +/- 0.0008
hostname:sdfmilan231 rank:022 cpu:100 cmt:1p-v4 proc time (sec) mean: 0.0424 +/- 0.0010 rms: 0.0014 +/- 0.0007
hostname:sdfmilan231 rank:023 cpu:122 cmt:1p-v4 proc time (sec) mean: 0.0413 +/- 0.0006 rms: 0.0007 +/- 0.0004
hostname:sdfmilan231 rank:024 cpu:006 cmt:1p-v4 proc time (sec) mean: 0.0442 +/- 0.0010 rms: 0.0012 +/- 0.0007
hostname:sdfmilan231 rank:025 cpu:029 cmt:1p-v4 proc time (sec) mean: 0.0450 +/- 0.0019 rms: 0.0032 +/- 0.0013
hostname:sdfmilan231 rank:026 cpu:047 cmt:1p-v4 proc time (sec) mean: 0.0439 +/- 0.0009 rms: 0.0010 +/- 0.0006
hostname:sdfmilan231 rank:027 cpu:063 cmt:1p-v4 proc time (sec) mean: 0.0440 +/- 0.0008 rms: 0.0009 +/- 0.0006
hostname:sdfmilan231 rank:028 cpu:070 cmt:1p-v4 proc time (sec) mean: 0.0421 +/- 0.0011 rms: 0.0015 +/- 0.0008
hostname:sdfmilan231 rank:029 cpu:095 cmt:1p-v4 proc time (sec) mean: 0.0437 +/- 0.0015 rms: 0.0028 +/- 0.0011
hostname:sdfmilan231 rank:030 cpu:108 cmt:1p-v4 proc time (sec) mean: 0.0419 +/- 0.0009 rms: 0.0012 +/- 0.0006
hostname:sdfmilan231 rank:031 cpu:113 cmt:1p-v4 proc time (sec) mean: 0.0414 +/- 0.0008 rms: 0.0009 +/- 0.0006
hostname:sdfmilan231 rank:032 cpu:009 cmt:1p-v4 proc time (sec) mean: 0.0440 +/- 0.0010 rms: 0.0012 +/- 0.0007
hostname:sdfmilan231 rank:033 cpu:028 cmt:1p-v4 proc time (sec) mean: 0.0456 +/- 0.0022 rms: 0.0037 +/- 0.0015
hostname:sdfmilan231 rank:034 cpu:034 cmt:1p-v4 proc time (sec) mean: 0.0441 +/- 0.0011 rms: 0.0014 +/- 0.0008
hostname:sdfmilan231 rank:035 cpu:056 cmt:1p-v4 proc time (sec) mean: 0.0439 +/- 0.0011 rms: 0.0013 +/- 0.0008
hostname:sdfmilan231 rank:036 cpu:076 cmt:1p-v4 proc time (sec) mean: 0.0435 +/- 0.0011 rms: 0.0017 +/- 0.0008
hostname:sdfmilan231 rank:037 cpu:093 cmt:1p-v4 proc time (sec) mean: 0.0435 +/- 0.0015 rms: 0.0024 +/- 0.0011
hostname:sdfmilan231 rank:038 cpu:110 cmt:1p-v4 proc time (sec) mean: 0.0419 +/- 0.0009 rms: 0.0012 +/- 0.0006
hostname:sdfmilan231 rank:039 cpu:126 cmt:1p-v4 proc time (sec) mean: 0.0414 +/- 0.0007 rms: 0.0008 +/- 0.0005
hostname:sdfmilan231 rank:040 cpu:010 cmt:1p-v4 proc time (sec) mean: 0.0439 +/- 0.0010 rms: 0.0012 +/- 0.0007
hostname:sdfmilan231 rank:041 cpu:027 cmt:1p-v4 proc time (sec) mean: 0.0443 +/- 0.0018 rms: 0.0026 +/- 0.0013
hostname:sdfmilan231 rank:042 cpu:040 cmt:1p-v4 proc time (sec) mean: 0.0441 +/- 0.0012 rms: 0.0015 +/- 0.0009
hostname:sdfmilan231 rank:043 cpu:062 cmt:1p-v4 proc time (sec) mean: 0.0439 +/- 0.0007 rms: 0.0008 +/- 0.0005
hostname:sdfmilan231 rank:044 cpu:072 cmt:1p-v4 proc time (sec) mean: 0.0428 +/- 0.0012 rms: 0.0020 +/- 0.0009
hostname:sdfmilan231 rank:045 cpu:083 cmt:1p-v4 proc time (sec) mean: 0.0421 +/- 0.0011 rms: 0.0014 +/- 0.0008
hostname:sdfmilan231 rank:046 cpu:098 cmt:1p-v4 proc time (sec) mean: 0.0420 +/- 0.0010 rms: 0.0013 +/- 0.0007
hostname:sdfmilan231 rank:047 cpu:118 cmt:1p-v4 proc time (sec) mean: 0.0414 +/- 0.0010 rms: 0.0011 +/- 0.0007
hostname:sdfmilan231 rank:048 cpu:013 cmt:1p-v4 proc time (sec) mean: 0.0440 +/- 0.0009 rms: 0.0010 +/- 0.0006
hostname:sdfmilan231 rank:049 cpu:029 cmt:1p-v4 proc time (sec) mean: 0.0448 +/- 0.0021 rms: 0.0031 +/- 0.0015
hostname:sdfmilan231 rank:050 cpu:039 cmt:1p-v4 proc time (sec) mean: 0.0442 +/- 0.0013 rms: 0.0017 +/- 0.0009
hostname:sdfmilan231 rank:051 cpu:057 cmt:1p-v4 proc time (sec) mean: 0.0439 +/- 0.0011 rms: 0.0013 +/- 0.0008
hostname:sdfmilan231 rank:052 cpu:072 cmt:1p-v4 proc time (sec) mean: 0.0430 +/- 0.0013 rms: 0.0021 +/- 0.0009
hostname:sdfmilan231 rank:053 cpu:086 cmt:1p-v4 proc time (sec) mean: 0.0428 +/- 0.0011 rms: 0.0017 +/- 0.0008
hostname:sdfmilan231 rank:054 cpu:102 cmt:1p-v4 proc time (sec) mean: 0.0419 +/- 0.0010 rms: 0.0014 +/- 0.0007
hostname:sdfmilan231 rank:055 cpu:115 cmt:1p-v4 proc time (sec) mean: 0.0415 +/- 0.0008 rms: 0.0008 +/- 0.0005
hostname:sdfmilan231 rank:056 cpu:008 cmt:1p-v4 proc time (sec) mean: 0.0441 +/- 0.0014 rms: 0.0018 +/- 0.0010
hostname:sdfmilan231 rank:057 cpu:030 cmt:1p-v4 proc time (sec) mean: 0.0450 +/- 0.0022 rms: 0.0037 +/- 0.0015
hostname:sdfmilan231 rank:058 cpu:045 cmt:1p-v4 proc time (sec) mean: 0.0439 +/- 0.0015 rms: 0.0018 +/- 0.0010
hostname:sdfmilan231 rank:059 cpu:050 cmt:1p-v4 proc time (sec) mean: 0.0440 +/- 0.0011 rms: 0.0014 +/- 0.0008
hostname:sdfmilan231 rank:060 cpu:079 cmt:1p-v4 proc time (sec) mean: 0.0427 +/- 0.0011 rms: 0.0018 +/- 0.0008
hostname:sdfmilan231 rank:061 cpu:080 cmt:1p-v4 proc time (sec) mean: 0.0428 +/- 0.0015 rms: 0.0024 +/- 0.0011
hostname:sdfmilan231 rank:062 cpu:105 cmt:1p-v4 proc time (sec) mean: 0.0415 +/- 0.0010 rms: 0.0012 +/- 0.0007
hostname:sdfmilan231 rank:063 cpu:121 cmt:1p-v4 proc time (sec) mean: 0.0418 +/- 0.0010 rms: 0.0012 +/- 0.0007
hostname:sdfmilan231 rank:064 cpu:002 cmt:1p-v4 proc time (sec) mean: 0.0444 +/- 0.0012 rms: 0.0016 +/- 0.0009
hostname:sdfmilan231 rank:065 cpu:036 cmt:1p-v4 proc time (sec) mean: 0.0440 +/- 0.0013 rms: 0.0015 +/- 0.0009
hostname:sdfmilan231 rank:066 cpu:032 cmt:1p-v4 proc time (sec) mean: 0.0439 +/- 0.0015 rms: 0.0020 +/- 0.0011
hostname:sdfmilan231 rank:067 cpu:055 cmt:1p-v4 proc time (sec) mean: 0.0439 +/- 0.0011 rms: 0.0013 +/- 0.0008
hostname:sdfmilan231 rank:068 cpu:066 cmt:1p-v4 proc time (sec) mean: 0.0426 +/- 0.0012 rms: 0.0018 +/- 0.0008
hostname:sdfmilan231 rank:069 cpu:092 cmt:1p-v4 proc time (sec) mean: 0.0438 +/- 0.0015 rms: 0.0027 +/- 0.0011
hostname:sdfmilan231 rank:070 cpu:107 cmt:1p-v4 proc time (sec) mean: 0.0416 +/- 0.0010 rms: 0.0013 +/- 0.0007
hostname:sdfmilan231 rank:071 cpu:123 cmt:1p-v4 proc time (sec) mean: 0.0414 +/- 0.0009 rms: 0.0011 +/- 0.0007
hostname:sdfmilan231 rank:072 cpu:004 cmt:1p-v4 proc time (sec) mean: 0.0438 +/- 0.0009 rms: 0.0010 +/- 0.0006
hostname:sdfmilan231 rank:073 cpu:046 cmt:1p-v4 proc time (sec) mean: 0.0439 +/- 0.0009 rms: 0.0010 +/- 0.0006
hostname:sdfmilan231 rank:074 cpu:035 cmt:1p-v4 proc time (sec) mean: 0.0440 +/- 0.0014 rms: 0.0017 +/- 0.0010
hostname:sdfmilan231 rank:075 cpu:051 cmt:1p-v4 proc time (sec) mean: 0.0439 +/- 0.0008 rms: 0.0009 +/- 0.0005
hostname:sdfmilan231 rank:076 cpu:078 cmt:1p-v4 proc time (sec) mean: 0.0427 +/- 0.0012 rms: 0.0019 +/- 0.0008
hostname:sdfmilan231 rank:077 cpu:082 cmt:1p-v4 proc time (sec) mean: 0.0432 +/- 0.0011 rms: 0.0017 +/- 0.0008
hostname:sdfmilan231 rank:078 cpu:109 cmt:1p-v4 proc time (sec) mean: 0.0416 +/- 0.0010 rms: 0.0012 +/- 0.0007
hostname:sdfmilan231 rank:079 cpu:119 cmt:1p-v4 proc time (sec) mean: 0.0414 +/- 0.0008 rms: 0.0010 +/- 0.0006
mean time (sec): 0.0433

New algorithm on single core

New algorithm on 80-core

Summary

Single-panel dataset xcsx1003522 -r32 -d XcsEndstation.0:Jungfrau.1:  timing per-event per-core, ms on sdfmilan231

number of coresold algorithm calib_jungfrau←Ratio 80/1new algorithm v2←Ratio 80/1
144.0133.91
8063.81.4543.31.28

8-panel cxilx7422 -r232 -d CxiDs1.0:Jungfrau.0 

number of coresold algorithm←Ratio 80/1new algorithm v2←Ratio 80/1
136612731
807972.184021.47

2024-03-04 comparison of the new algorithm of calib_jungfrau

Description

dataset 8-panel cxilx7422 -r232 -d CxiDs1.0:Jungfrau.0 

  • old calib_jungfrau
  • new calib_jungfrau_v2 - cache only what is used, pedestals+offeset, gain factor
  • new calib_jungfrau_v2 with loop over panels

Results

Timing, sec, per event per core for three algorithms
sys.argv: ['Detector/examples/test-scaling-mpi.py', '-99']
selector for mode: -99

sort_records_in_file: figs/fig-mpi-data-8p-v3-sdfmilan204-ncores01-summary.txt
records:
means: shape:(4,) size:4 dtype:float64
[0.3656 0.3657 0.3659 0.3665]
mean time (sec): 0.3659

hostname:sdfmilan204 rank:000 cpu:000 cmt:8p-v3 proc time (sec) mean: 0.3656 +/- 0.0022 rms: 0.0024 +/- 0.0016
hostname:sdfmilan204 rank:000 cpu:000 cmt:8p-v3 proc time (sec) mean: 0.3657 +/- 0.0024 rms: 0.0026 +/- 0.0017
hostname:sdfmilan204 rank:000 cpu:000 cmt:8p-v3 proc time (sec) mean: 0.3659 +/- 0.0026 rms: 0.0029 +/- 0.0019
hostname:sdfmilan204 rank:000 cpu:000 cmt:8p-v3 proc time (sec) mean: 0.3665 +/- 0.0031 rms: 0.0036 +/- 0.0022
mean time (sec): 0.3659



sort_records_in_file: figs/fig-mpi-data-8p-v3-sdfmilan204-ncores80-summary.txt
records:
means: shape:(80,) size:80 dtype:float64
[0.6772 0.6566 0.8372 0.6568 0.729  0.7307 0.8172 0.8393 0.6869 0.662
 0.8665 0.6327 0.7245 0.7524 0.8238 0.8387 0.6682 0.6615 0.8487 0.6436
 0.7326 0.7157 0.8361 0.8464 0.6733 0.6549 0.8374 0.633  0.7159 0.7226
 0.8231 0.8837 0.6887 0.6538 0.8605 0.6468 0.7195 0.6723 0.8215 0.864
 0.6763 0.6497 0.8388 0.6482 0.7112 0.6927 0.8733 0.8451 0.6761 0.6403
 0.8283 0.6373 0.7759 0.772  0.8322 0.8172 0.6863 0.6625 0.8891 0.6348
 0.7288 0.7163 0.8268 0.8546 0.6684 0.8879 0.866  0.6476 0.7315 0.808
 0.8225 0.8418 0.6718 0.8782 0.8417 0.6314 0.7376 0.7702 0.84   0.8459]
mean time (sec): 0.7520

hostname:sdfmilan204 rank:000 cpu:004 cmt:8p-v3 proc time (sec) mean: 0.6772 +/- 0.0238 rms: 0.1387 +/- 0.0168
hostname:sdfmilan204 rank:001 cpu:028 cmt:8p-v3 proc time (sec) mean: 0.6566 +/- 0.0253 rms: 0.1285 +/- 0.0179
hostname:sdfmilan204 rank:002 cpu:033 cmt:8p-v3 proc time (sec) mean: 0.8372 +/- 0.0606 rms: 0.4046 +/- 0.0428
hostname:sdfmilan204 rank:003 cpu:054 cmt:8p-v3 proc time (sec) mean: 0.6568 +/- 0.0263 rms: 0.1437 +/- 0.0186
hostname:sdfmilan204 rank:004 cpu:073 cmt:8p-v3 proc time (sec) mean: 0.7290 +/- 0.0804 rms: 0.4223 +/- 0.0568
hostname:sdfmilan204 rank:005 cpu:092 cmt:8p-v3 proc time (sec) mean: 0.7307 +/- 0.0697 rms: 0.3964 +/- 0.0493
hostname:sdfmilan204 rank:006 cpu:101 cmt:8p-v3 proc time (sec) mean: 0.8172 +/- 0.0468 rms: 0.3277 +/- 0.0331
hostname:sdfmilan204 rank:007 cpu:120 cmt:8p-v3 proc time (sec) mean: 0.8393 +/- 0.0589 rms: 0.3849 +/- 0.0416
hostname:sdfmilan204 rank:008 cpu:014 cmt:8p-v3 proc time (sec) mean: 0.6869 +/- 0.0231 rms: 0.1382 +/- 0.0164
hostname:sdfmilan204 rank:009 cpu:030 cmt:8p-v3 proc time (sec) mean: 0.6620 +/- 0.0220 rms: 0.1208 +/- 0.0156
hostname:sdfmilan204 rank:010 cpu:032 cmt:8p-v3 proc time (sec) mean: 0.8665 +/- 0.0551 rms: 0.4105 +/- 0.0389
hostname:sdfmilan204 rank:011 cpu:050 cmt:8p-v3 proc time (sec) mean: 0.6327 +/- 0.0256 rms: 0.1308 +/- 0.0181
hostname:sdfmilan204 rank:012 cpu:074 cmt:8p-v3 proc time (sec) mean: 0.7245 +/- 0.0801 rms: 0.4073 +/- 0.0566
hostname:sdfmilan204 rank:013 cpu:084 cmt:8p-v3 proc time (sec) mean: 0.7524 +/- 0.0773 rms: 0.4402 +/- 0.0547
hostname:sdfmilan204 rank:014 cpu:105 cmt:8p-v3 proc time (sec) mean: 0.8238 +/- 0.0437 rms: 0.3185 +/- 0.0309
hostname:sdfmilan204 rank:015 cpu:119 cmt:8p-v3 proc time (sec) mean: 0.8387 +/- 0.0487 rms: 0.3476 +/- 0.0344
hostname:sdfmilan204 rank:016 cpu:012 cmt:8p-v3 proc time (sec) mean: 0.6682 +/- 0.0240 rms: 0.1364 +/- 0.0170
hostname:sdfmilan204 rank:017 cpu:026 cmt:8p-v3 proc time (sec) mean: 0.6615 +/- 0.0227 rms: 0.1175 +/- 0.0161
hostname:sdfmilan204 rank:018 cpu:045 cmt:8p-v3 proc time (sec) mean: 0.8487 +/- 0.0606 rms: 0.4048 +/- 0.0428
hostname:sdfmilan204 rank:019 cpu:056 cmt:8p-v3 proc time (sec) mean: 0.6436 +/- 0.0233 rms: 0.1249 +/- 0.0165
hostname:sdfmilan204 rank:020 cpu:064 cmt:8p-v3 proc time (sec) mean: 0.7326 +/- 0.0746 rms: 0.4027 +/- 0.0528
hostname:sdfmilan204 rank:021 cpu:085 cmt:8p-v3 proc time (sec) mean: 0.7157 +/- 0.0761 rms: 0.4000 +/- 0.0538
hostname:sdfmilan204 rank:022 cpu:107 cmt:8p-v3 proc time (sec) mean: 0.8361 +/- 0.0465 rms: 0.3269 +/- 0.0329
hostname:sdfmilan204 rank:023 cpu:127 cmt:8p-v3 proc time (sec) mean: 0.8464 +/- 0.0544 rms: 0.3633 +/- 0.0385
hostname:sdfmilan204 rank:024 cpu:005 cmt:8p-v3 proc time (sec) mean: 0.6733 +/- 0.0248 rms: 0.1361 +/- 0.0175
hostname:sdfmilan204 rank:025 cpu:024 cmt:8p-v3 proc time (sec) mean: 0.6549 +/- 0.0227 rms: 0.1252 +/- 0.0160
hostname:sdfmilan204 rank:026 cpu:042 cmt:8p-v3 proc time (sec) mean: 0.8374 +/- 0.0596 rms: 0.4033 +/- 0.0422
hostname:sdfmilan204 rank:027 cpu:053 cmt:8p-v3 proc time (sec) mean: 0.6330 +/- 0.0259 rms: 0.1352 +/- 0.0183
hostname:sdfmilan204 rank:028 cpu:078 cmt:8p-v3 proc time (sec) mean: 0.7159 +/- 0.0828 rms: 0.3991 +/- 0.0585
hostname:sdfmilan204 rank:029 cpu:082 cmt:8p-v3 proc time (sec) mean: 0.7226 +/- 0.0692 rms: 0.3899 +/- 0.0489
hostname:sdfmilan204 rank:030 cpu:099 cmt:8p-v3 proc time (sec) mean: 0.8231 +/- 0.0516 rms: 0.3347 +/- 0.0365
hostname:sdfmilan204 rank:031 cpu:118 cmt:8p-v3 proc time (sec) mean: 0.8837 +/- 0.0561 rms: 0.4139 +/- 0.0397
hostname:sdfmilan204 rank:032 cpu:006 cmt:8p-v3 proc time (sec) mean: 0.6887 +/- 0.0259 rms: 0.1492 +/- 0.0183
hostname:sdfmilan204 rank:033 cpu:030 cmt:8p-v3 proc time (sec) mean: 0.6538 +/- 0.0223 rms: 0.1077 +/- 0.0158
hostname:sdfmilan204 rank:034 cpu:034 cmt:8p-v3 proc time (sec) mean: 0.8605 +/- 0.0627 rms: 0.4266 +/- 0.0443
hostname:sdfmilan204 rank:035 cpu:058 cmt:8p-v3 proc time (sec) mean: 0.6468 +/- 0.0246 rms: 0.1345 +/- 0.0174
hostname:sdfmilan204 rank:036 cpu:067 cmt:8p-v3 proc time (sec) mean: 0.7195 +/- 0.0794 rms: 0.3984 +/- 0.0562
hostname:sdfmilan204 rank:037 cpu:095 cmt:8p-v3 proc time (sec) mean: 0.6723 +/- 0.0618 rms: 0.3352 +/- 0.0437
hostname:sdfmilan204 rank:038 cpu:110 cmt:8p-v3 proc time (sec) mean: 0.8215 +/- 0.0460 rms: 0.3075 +/- 0.0325
hostname:sdfmilan204 rank:039 cpu:116 cmt:8p-v3 proc time (sec) mean: 0.8640 +/- 0.0499 rms: 0.3379 +/- 0.0353
hostname:sdfmilan204 rank:040 cpu:013 cmt:8p-v3 proc time (sec) mean: 0.6763 +/- 0.0235 rms: 0.1382 +/- 0.0166
hostname:sdfmilan204 rank:041 cpu:029 cmt:8p-v3 proc time (sec) mean: 0.6497 +/- 0.0226 rms: 0.1086 +/- 0.0160
hostname:sdfmilan204 rank:042 cpu:032 cmt:8p-v3 proc time (sec) mean: 0.8388 +/- 0.0575 rms: 0.3842 +/- 0.0407
hostname:sdfmilan204 rank:043 cpu:062 cmt:8p-v3 proc time (sec) mean: 0.6482 +/- 0.0247 rms: 0.1374 +/- 0.0175
hostname:sdfmilan204 rank:044 cpu:079 cmt:8p-v3 proc time (sec) mean: 0.7112 +/- 0.0794 rms: 0.4107 +/- 0.0562
hostname:sdfmilan204 rank:045 cpu:088 cmt:8p-v3 proc time (sec) mean: 0.6927 +/- 0.0647 rms: 0.3530 +/- 0.0458
hostname:sdfmilan204 rank:046 cpu:111 cmt:8p-v3 proc time (sec) mean: 0.8733 +/- 0.0498 rms: 0.3674 +/- 0.0352
hostname:sdfmilan204 rank:047 cpu:117 cmt:8p-v3 proc time (sec) mean: 0.8451 +/- 0.0476 rms: 0.3454 +/- 0.0337
hostname:sdfmilan204 rank:048 cpu:011 cmt:8p-v3 proc time (sec) mean: 0.6761 +/- 0.0283 rms: 0.1493 +/- 0.0200
hostname:sdfmilan204 rank:049 cpu:027 cmt:8p-v3 proc time (sec) mean: 0.6403 +/- 0.0221 rms: 0.1130 +/- 0.0157
hostname:sdfmilan204 rank:050 cpu:039 cmt:8p-v3 proc time (sec) mean: 0.8283 +/- 0.0629 rms: 0.4153 +/- 0.0445
hostname:sdfmilan204 rank:051 cpu:052 cmt:8p-v3 proc time (sec) mean: 0.6373 +/- 0.0223 rms: 0.1191 +/- 0.0158
hostname:sdfmilan204 rank:052 cpu:071 cmt:8p-v3 proc time (sec) mean: 0.7759 +/- 0.0882 rms: 0.4481 +/- 0.0623
hostname:sdfmilan204 rank:053 cpu:089 cmt:8p-v3 proc time (sec) mean: 0.7720 +/- 0.0829 rms: 0.4419 +/- 0.0586
hostname:sdfmilan204 rank:054 cpu:109 cmt:8p-v3 proc time (sec) mean: 0.8322 +/- 0.0490 rms: 0.3335 +/- 0.0347
hostname:sdfmilan204 rank:055 cpu:122 cmt:8p-v3 proc time (sec) mean: 0.8172 +/- 0.0528 rms: 0.3424 +/- 0.0373
hostname:sdfmilan204 rank:056 cpu:008 cmt:8p-v3 proc time (sec) mean: 0.6863 +/- 0.0264 rms: 0.1447 +/- 0.0186
hostname:sdfmilan204 rank:057 cpu:025 cmt:8p-v3 proc time (sec) mean: 0.6625 +/- 0.0214 rms: 0.1143 +/- 0.0151
hostname:sdfmilan204 rank:058 cpu:046 cmt:8p-v3 proc time (sec) mean: 0.8891 +/- 0.0650 rms: 0.4549 +/- 0.0459
hostname:sdfmilan204 rank:059 cpu:061 cmt:8p-v3 proc time (sec) mean: 0.6348 +/- 0.0231 rms: 0.1250 +/- 0.0163
hostname:sdfmilan204 rank:060 cpu:075 cmt:8p-v3 proc time (sec) mean: 0.7288 +/- 0.0784 rms: 0.4056 +/- 0.0555
hostname:sdfmilan204 rank:061 cpu:089 cmt:8p-v3 proc time (sec) mean: 0.7163 +/- 0.0743 rms: 0.4117 +/- 0.0526
hostname:sdfmilan204 rank:062 cpu:100 cmt:8p-v3 proc time (sec) mean: 0.8268 +/- 0.0509 rms: 0.3414 +/- 0.0360
hostname:sdfmilan204 rank:063 cpu:126 cmt:8p-v3 proc time (sec) mean: 0.8546 +/- 0.0498 rms: 0.3489 +/- 0.0352
hostname:sdfmilan204 rank:064 cpu:009 cmt:8p-v3 proc time (sec) mean: 0.6684 +/- 0.0264 rms: 0.1486 +/- 0.0187
hostname:sdfmilan204 rank:065 cpu:043 cmt:8p-v3 proc time (sec) mean: 0.8879 +/- 0.0518 rms: 0.4023 +/- 0.0366
hostname:sdfmilan204 rank:066 cpu:047 cmt:8p-v3 proc time (sec) mean: 0.8660 +/- 0.0628 rms: 0.4222 +/- 0.0444
hostname:sdfmilan204 rank:067 cpu:049 cmt:8p-v3 proc time (sec) mean: 0.6476 +/- 0.0250 rms: 0.1422 +/- 0.0177
hostname:sdfmilan204 rank:068 cpu:070 cmt:8p-v3 proc time (sec) mean: 0.7315 +/- 0.0764 rms: 0.4076 +/- 0.0540
hostname:sdfmilan204 rank:069 cpu:090 cmt:8p-v3 proc time (sec) mean: 0.8080 +/- 0.0817 rms: 0.4574 +/- 0.0578
hostname:sdfmilan204 rank:070 cpu:103 cmt:8p-v3 proc time (sec) mean: 0.8225 +/- 0.0478 rms: 0.3022 +/- 0.0338
hostname:sdfmilan204 rank:071 cpu:114 cmt:8p-v3 proc time (sec) mean: 0.8418 +/- 0.0509 rms: 0.3499 +/- 0.0360
hostname:sdfmilan204 rank:072 cpu:001 cmt:8p-v3 proc time (sec) mean: 0.6718 +/- 0.0248 rms: 0.1397 +/- 0.0176
hostname:sdfmilan204 rank:073 cpu:038 cmt:8p-v3 proc time (sec) mean: 0.8782 +/- 0.0619 rms: 0.4253 +/- 0.0438
hostname:sdfmilan204 rank:074 cpu:037 cmt:8p-v3 proc time (sec) mean: 0.8417 +/- 0.0722 rms: 0.4551 +/- 0.0511
hostname:sdfmilan204 rank:075 cpu:063 cmt:8p-v3 proc time (sec) mean: 0.6314 +/- 0.0250 rms: 0.1267 +/- 0.0177
hostname:sdfmilan204 rank:076 cpu:068 cmt:8p-v3 proc time (sec) mean: 0.7376 +/- 0.0826 rms: 0.4325 +/- 0.0584
hostname:sdfmilan204 rank:077 cpu:087 cmt:8p-v3 proc time (sec) mean: 0.7702 +/- 0.0743 rms: 0.4474 +/- 0.0525
hostname:sdfmilan204 rank:078 cpu:104 cmt:8p-v3 proc time (sec) mean: 0.8400 +/- 0.0535 rms: 0.3525 +/- 0.0378
hostname:sdfmilan204 rank:079 cpu:123 cmt:8p-v3 proc time (sec) mean: 0.8459 +/- 0.0553 rms: 0.3818 +/- 0.0391
mean time (sec): 0.7520



sort_records_in_file: figs/fig-mpi-data-8p-v4-sdfmilan204-ncores01-summary.txt
records:
means: shape:(5,) size:5 dtype:float64
[0.2721 0.2732 0.2738 0.2749 0.275 ]
mean time (sec): 0.2738

hostname:sdfmilan204 rank:000 cpu:000 cmt:8p-v4 proc time (sec) mean: 0.2721 +/- 0.0054 rms: 0.0065 +/- 0.0038
hostname:sdfmilan204 rank:000 cpu:000 cmt:8p-v4 proc time (sec) mean: 0.2732 +/- 0.0032 rms: 0.0038 +/- 0.0023
hostname:sdfmilan204 rank:000 cpu:000 cmt:8p-v4 proc time (sec) mean: 0.2738 +/- 0.0040 rms: 0.0045 +/- 0.0028
hostname:sdfmilan204 rank:000 cpu:000 cmt:8p-v4 proc time (sec) mean: 0.2749 +/- 0.0010 rms: 0.0010 +/- 0.0007
hostname:sdfmilan204 rank:000 cpu:000 cmt:8p-v4 proc time (sec) mean: 0.2750 +/- 0.0000 rms: 0.0000 +/- 0.0000
mean time (sec): 0.2738



sort_records_in_file: figs/fig-mpi-data-8p-v4-sdfmilan204-ncores80-summary.txt
records:
means: shape:(80,) size:80 dtype:float64
[0.3932 0.3677 0.3878 0.3669 0.3968 0.3904 0.3593 0.3876 0.4013 0.3612
 0.3764 0.3652 0.3864 0.3837 0.3903 0.3867 0.3959 0.3698 0.3725 0.3656
 0.4171 0.3942 0.3511 0.3832 0.3993 0.3581 0.3996 0.3526 0.3996 0.359
 0.3521 0.3892 0.4069 0.3623 0.3825 0.3598 0.4061 0.3886 0.3559 0.3809
 0.4034 0.3657 0.3937 0.3543 0.4139 0.3814 0.3493 0.3894 0.3948 0.3703
 0.393  0.3697 0.3751 0.3913 0.3687 0.3854 0.403  0.3659 0.388  0.366
 0.4055 0.3432 0.3623 0.3855 0.408  0.3958 0.3851 0.3659 0.4086 0.3601
 0.3758 0.3904 0.3961 0.4021 0.3919 0.3572 0.4118 0.3619 0.3729 0.387 ]
mean time (sec): 0.3812

hostname:sdfmilan204 rank:000 cpu:005 cmt:8p-v4 proc time (sec) mean: 0.3932 +/- 0.0138 rms: 0.0409 +/- 0.0098
hostname:sdfmilan204 rank:001 cpu:025 cmt:8p-v4 proc time (sec) mean: 0.3677 +/- 0.0061 rms: 0.0104 +/- 0.0043
hostname:sdfmilan204 rank:002 cpu:046 cmt:8p-v4 proc time (sec) mean: 0.3878 +/- 0.0148 rms: 0.0399 +/- 0.0105
hostname:sdfmilan204 rank:003 cpu:059 cmt:8p-v4 proc time (sec) mean: 0.3669 +/- 0.0055 rms: 0.0104 +/- 0.0039
hostname:sdfmilan204 rank:004 cpu:070 cmt:8p-v4 proc time (sec) mean: 0.3968 +/- 0.0156 rms: 0.0588 +/- 0.0110
hostname:sdfmilan204 rank:005 cpu:094 cmt:8p-v4 proc time (sec) mean: 0.3904 +/- 0.0152 rms: 0.0474 +/- 0.0108
hostname:sdfmilan204 rank:006 cpu:097 cmt:8p-v4 proc time (sec) mean: 0.3593 +/- 0.0080 rms: 0.0207 +/- 0.0057
hostname:sdfmilan204 rank:007 cpu:116 cmt:8p-v4 proc time (sec) mean: 0.3876 +/- 0.0106 rms: 0.0317 +/- 0.0075
hostname:sdfmilan204 rank:008 cpu:010 cmt:8p-v4 proc time (sec) mean: 0.4013 +/- 0.0121 rms: 0.0327 +/- 0.0085
hostname:sdfmilan204 rank:009 cpu:028 cmt:8p-v4 proc time (sec) mean: 0.3612 +/- 0.0059 rms: 0.0118 +/- 0.0042
hostname:sdfmilan204 rank:010 cpu:042 cmt:8p-v4 proc time (sec) mean: 0.3764 +/- 0.0084 rms: 0.0202 +/- 0.0060
hostname:sdfmilan204 rank:011 cpu:050 cmt:8p-v4 proc time (sec) mean: 0.3652 +/- 0.0084 rms: 0.0153 +/- 0.0059
hostname:sdfmilan204 rank:012 cpu:068 cmt:8p-v4 proc time (sec) mean: 0.3864 +/- 0.0138 rms: 0.0487 +/- 0.0098
hostname:sdfmilan204 rank:013 cpu:080 cmt:8p-v4 proc time (sec) mean: 0.3837 +/- 0.0115 rms: 0.0402 +/- 0.0081
hostname:sdfmilan204 rank:014 cpu:104 cmt:8p-v4 proc time (sec) mean: 0.3903 +/- 0.0128 rms: 0.0405 +/- 0.0090
hostname:sdfmilan204 rank:015 cpu:117 cmt:8p-v4 proc time (sec) mean: 0.3867 +/- 0.0097 rms: 0.0330 +/- 0.0069
hostname:sdfmilan204 rank:016 cpu:012 cmt:8p-v4 proc time (sec) mean: 0.3959 +/- 0.0129 rms: 0.0351 +/- 0.0092
hostname:sdfmilan204 rank:017 cpu:031 cmt:8p-v4 proc time (sec) mean: 0.3698 +/- 0.0060 rms: 0.0110 +/- 0.0042
hostname:sdfmilan204 rank:018 cpu:040 cmt:8p-v4 proc time (sec) mean: 0.3725 +/- 0.0090 rms: 0.0204 +/- 0.0063
hostname:sdfmilan204 rank:019 cpu:048 cmt:8p-v4 proc time (sec) mean: 0.3656 +/- 0.0060 rms: 0.0120 +/- 0.0043
hostname:sdfmilan204 rank:020 cpu:069 cmt:8p-v4 proc time (sec) mean: 0.4171 +/- 0.0178 rms: 0.0739 +/- 0.0126
hostname:sdfmilan204 rank:021 cpu:080 cmt:8p-v4 proc time (sec) mean: 0.3942 +/- 0.0140 rms: 0.0487 +/- 0.0099
hostname:sdfmilan204 rank:022 cpu:110 cmt:8p-v4 proc time (sec) mean: 0.3511 +/- 0.0116 rms: 0.0289 +/- 0.0082
hostname:sdfmilan204 rank:023 cpu:125 cmt:8p-v4 proc time (sec) mean: 0.3832 +/- 0.0105 rms: 0.0345 +/- 0.0074
hostname:sdfmilan204 rank:024 cpu:007 cmt:8p-v4 proc time (sec) mean: 0.3993 +/- 0.0165 rms: 0.0421 +/- 0.0117
hostname:sdfmilan204 rank:025 cpu:029 cmt:8p-v4 proc time (sec) mean: 0.3581 +/- 0.0048 rms: 0.0083 +/- 0.0034
hostname:sdfmilan204 rank:026 cpu:035 cmt:8p-v4 proc time (sec) mean: 0.3996 +/- 0.0125 rms: 0.0387 +/- 0.0089
hostname:sdfmilan204 rank:027 cpu:051 cmt:8p-v4 proc time (sec) mean: 0.3526 +/- 0.0055 rms: 0.0095 +/- 0.0039
hostname:sdfmilan204 rank:028 cpu:075 cmt:8p-v4 proc time (sec) mean: 0.3996 +/- 0.0135 rms: 0.0524 +/- 0.0096
hostname:sdfmilan204 rank:029 cpu:084 cmt:8p-v4 proc time (sec) mean: 0.3590 +/- 0.0099 rms: 0.0283 +/- 0.0070
hostname:sdfmilan204 rank:030 cpu:105 cmt:8p-v4 proc time (sec) mean: 0.3521 +/- 0.0076 rms: 0.0182 +/- 0.0054
hostname:sdfmilan204 rank:031 cpu:112 cmt:8p-v4 proc time (sec) mean: 0.3892 +/- 0.0119 rms: 0.0373 +/- 0.0084
hostname:sdfmilan204 rank:032 cpu:013 cmt:8p-v4 proc time (sec) mean: 0.4069 +/- 0.0117 rms: 0.0314 +/- 0.0083
hostname:sdfmilan204 rank:033 cpu:030 cmt:8p-v4 proc time (sec) mean: 0.3623 +/- 0.0055 rms: 0.0097 +/- 0.0039
hostname:sdfmilan204 rank:034 cpu:047 cmt:8p-v4 proc time (sec) mean: 0.3825 +/- 0.0094 rms: 0.0249 +/- 0.0067
hostname:sdfmilan204 rank:035 cpu:048 cmt:8p-v4 proc time (sec) mean: 0.3598 +/- 0.0071 rms: 0.0130 +/- 0.0050
hostname:sdfmilan204 rank:036 cpu:067 cmt:8p-v4 proc time (sec) mean: 0.4061 +/- 0.0156 rms: 0.0632 +/- 0.0110
hostname:sdfmilan204 rank:037 cpu:085 cmt:8p-v4 proc time (sec) mean: 0.3886 +/- 0.0143 rms: 0.0418 +/- 0.0101
hostname:sdfmilan204 rank:038 cpu:107 cmt:8p-v4 proc time (sec) mean: 0.3559 +/- 0.0081 rms: 0.0189 +/- 0.0057
hostname:sdfmilan204 rank:039 cpu:118 cmt:8p-v4 proc time (sec) mean: 0.3809 +/- 0.0103 rms: 0.0336 +/- 0.0073
hostname:sdfmilan204 rank:040 cpu:008 cmt:8p-v4 proc time (sec) mean: 0.4034 +/- 0.0128 rms: 0.0359 +/- 0.0091
hostname:sdfmilan204 rank:041 cpu:026 cmt:8p-v4 proc time (sec) mean: 0.3657 +/- 0.0055 rms: 0.0104 +/- 0.0039
hostname:sdfmilan204 rank:042 cpu:037 cmt:8p-v4 proc time (sec) mean: 0.3937 +/- 0.0115 rms: 0.0338 +/- 0.0081
hostname:sdfmilan204 rank:043 cpu:054 cmt:8p-v4 proc time (sec) mean: 0.3543 +/- 0.0060 rms: 0.0103 +/- 0.0043
hostname:sdfmilan204 rank:044 cpu:073 cmt:8p-v4 proc time (sec) mean: 0.4139 +/- 0.0168 rms: 0.0680 +/- 0.0119
hostname:sdfmilan204 rank:045 cpu:086 cmt:8p-v4 proc time (sec) mean: 0.3814 +/- 0.0117 rms: 0.0398 +/- 0.0083
hostname:sdfmilan204 rank:046 cpu:099 cmt:8p-v4 proc time (sec) mean: 0.3493 +/- 0.0097 rms: 0.0227 +/- 0.0069
hostname:sdfmilan204 rank:047 cpu:122 cmt:8p-v4 proc time (sec) mean: 0.3894 +/- 0.0110 rms: 0.0333 +/- 0.0078
hostname:sdfmilan204 rank:048 cpu:011 cmt:8p-v4 proc time (sec) mean: 0.3948 +/- 0.0133 rms: 0.0353 +/- 0.0094
hostname:sdfmilan204 rank:049 cpu:025 cmt:8p-v4 proc time (sec) mean: 0.3703 +/- 0.0053 rms: 0.0090 +/- 0.0037
hostname:sdfmilan204 rank:050 cpu:039 cmt:8p-v4 proc time (sec) mean: 0.3930 +/- 0.0115 rms: 0.0335 +/- 0.0081
hostname:sdfmilan204 rank:051 cpu:062 cmt:8p-v4 proc time (sec) mean: 0.3697 +/- 0.0065 rms: 0.0140 +/- 0.0046
hostname:sdfmilan204 rank:052 cpu:065 cmt:8p-v4 proc time (sec) mean: 0.3751 +/- 0.0113 rms: 0.0377 +/- 0.0080
hostname:sdfmilan204 rank:053 cpu:095 cmt:8p-v4 proc time (sec) mean: 0.3913 +/- 0.0135 rms: 0.0514 +/- 0.0095
hostname:sdfmilan204 rank:054 cpu:111 cmt:8p-v4 proc time (sec) mean: 0.3687 +/- 0.0092 rms: 0.0262 +/- 0.0065
hostname:sdfmilan204 rank:055 cpu:126 cmt:8p-v4 proc time (sec) mean: 0.3854 +/- 0.0119 rms: 0.0401 +/- 0.0084
hostname:sdfmilan204 rank:056 cpu:001 cmt:8p-v4 proc time (sec) mean: 0.4030 +/- 0.0135 rms: 0.0368 +/- 0.0095
hostname:sdfmilan204 rank:057 cpu:030 cmt:8p-v4 proc time (sec) mean: 0.3659 +/- 0.0057 rms: 0.0096 +/- 0.0041
hostname:sdfmilan204 rank:058 cpu:044 cmt:8p-v4 proc time (sec) mean: 0.3880 +/- 0.0141 rms: 0.0416 +/- 0.0100
hostname:sdfmilan204 rank:059 cpu:060 cmt:8p-v4 proc time (sec) mean: 0.3660 +/- 0.0066 rms: 0.0141 +/- 0.0047
hostname:sdfmilan204 rank:060 cpu:078 cmt:8p-v4 proc time (sec) mean: 0.4055 +/- 0.0155 rms: 0.0585 +/- 0.0109
hostname:sdfmilan204 rank:061 cpu:080 cmt:8p-v4 proc time (sec) mean: 0.3432 +/- 0.0072 rms: 0.0170 +/- 0.0051
hostname:sdfmilan204 rank:062 cpu:106 cmt:8p-v4 proc time (sec) mean: 0.3623 +/- 0.0087 rms: 0.0231 +/- 0.0061
hostname:sdfmilan204 rank:063 cpu:115 cmt:8p-v4 proc time (sec) mean: 0.3855 +/- 0.0105 rms: 0.0353 +/- 0.0075
hostname:sdfmilan204 rank:064 cpu:009 cmt:8p-v4 proc time (sec) mean: 0.4080 +/- 0.0137 rms: 0.0355 +/- 0.0097
hostname:sdfmilan204 rank:065 cpu:034 cmt:8p-v4 proc time (sec) mean: 0.3958 +/- 0.0151 rms: 0.0481 +/- 0.0107
hostname:sdfmilan204 rank:066 cpu:043 cmt:8p-v4 proc time (sec) mean: 0.3851 +/- 0.0132 rms: 0.0375 +/- 0.0093
hostname:sdfmilan204 rank:067 cpu:058 cmt:8p-v4 proc time (sec) mean: 0.3659 +/- 0.0101 rms: 0.0218 +/- 0.0071
hostname:sdfmilan204 rank:068 cpu:071 cmt:8p-v4 proc time (sec) mean: 0.4086 +/- 0.0163 rms: 0.0634 +/- 0.0115
hostname:sdfmilan204 rank:069 cpu:081 cmt:8p-v4 proc time (sec) mean: 0.3601 +/- 0.0090 rms: 0.0272 +/- 0.0064
hostname:sdfmilan204 rank:070 cpu:101 cmt:8p-v4 proc time (sec) mean: 0.3758 +/- 0.0096 rms: 0.0278 +/- 0.0068
hostname:sdfmilan204 rank:071 cpu:113 cmt:8p-v4 proc time (sec) mean: 0.3904 +/- 0.0103 rms: 0.0330 +/- 0.0073
hostname:sdfmilan204 rank:072 cpu:006 cmt:8p-v4 proc time (sec) mean: 0.3961 +/- 0.0127 rms: 0.0379 +/- 0.0090
hostname:sdfmilan204 rank:073 cpu:033 cmt:8p-v4 proc time (sec) mean: 0.4021 +/- 0.0151 rms: 0.0524 +/- 0.0107
hostname:sdfmilan204 rank:074 cpu:040 cmt:8p-v4 proc time (sec) mean: 0.3919 +/- 0.0147 rms: 0.0468 +/- 0.0104
hostname:sdfmilan204 rank:075 cpu:055 cmt:8p-v4 proc time (sec) mean: 0.3572 +/- 0.0071 rms: 0.0132 +/- 0.0050
hostname:sdfmilan204 rank:076 cpu:076 cmt:8p-v4 proc time (sec) mean: 0.4118 +/- 0.0157 rms: 0.0659 +/- 0.0111
hostname:sdfmilan204 rank:077 cpu:092 cmt:8p-v4 proc time (sec) mean: 0.3619 +/- 0.0090 rms: 0.0268 +/- 0.0063
hostname:sdfmilan204 rank:078 cpu:104 cmt:8p-v4 proc time (sec) mean: 0.3729 +/- 0.0103 rms: 0.0274 +/- 0.0073
hostname:sdfmilan204 rank:079 cpu:123 cmt:8p-v4 proc time (sec) mean: 0.3870 +/- 0.0118 rms: 0.0391 +/- 0.0083
mean time (sec): 0.3812



sort_records_in_file: figs/fig-mpi-data-8p-v5-sdfmilan204-ncores01-summary.txt
records:
means: shape:(4,) size:4 dtype:float64
[0.2706 0.2707 0.2714 0.2739]
mean time (sec): 0.2717

hostname:sdfmilan204 rank:000 cpu:000 cmt:8p-v5 proc time (sec) mean: 0.2706 +/- 0.0035 rms: 0.0050 +/- 0.0025
hostname:sdfmilan204 rank:000 cpu:000 cmt:8p-v5 proc time (sec) mean: 0.2707 +/- 0.0035 rms: 0.0050 +/- 0.0025
hostname:sdfmilan204 rank:000 cpu:000 cmt:8p-v5 proc time (sec) mean: 0.2714 +/- 0.0036 rms: 0.0050 +/- 0.0026
hostname:sdfmilan204 rank:000 cpu:000 cmt:8p-v5 proc time (sec) mean: 0.2739 +/- 0.0028 rms: 0.0031 +/- 0.0020
mean time (sec): 0.2717



sort_records_in_file: figs/fig-mpi-data-8p-v5-sdfmilan204-ncores80-summary.txt
records:
means: shape:(80,) size:80 dtype:float64
[0.3307 0.3398 0.3395 0.333  0.3197 0.3179 0.3175 0.3227 0.3388 0.3392
 0.3341 0.3366 0.3161 0.3174 0.3216 0.3168 0.3353 0.3447 0.3414 0.3345
 0.3242 0.3185 0.3194 0.3154 0.3317 0.3408 0.3354 0.3337 0.3261 0.3221
 0.3214 0.3183 0.3361 0.344  0.3362 0.3302 0.3172 0.3191 0.3185 0.3181
 0.3335 0.3394 0.3345 0.3317 0.319  0.3183 0.3187 0.3237 0.3327 0.3399
 0.3339 0.3351 0.319  0.3159 0.3224 0.3204 0.3329 0.3405 0.3337 0.3309
 0.3178 0.3194 0.322  0.3177 0.3348 0.3346 0.3343 0.3298 0.3212 0.3184
 0.3204 0.3162 0.3386 0.3384 0.3369 0.3371 0.3157 0.3186 0.319  0.3168]
mean time (sec): 0.3276

hostname:sdfmilan204 rank:000 cpu:014 cmt:8p-v5 proc time (sec) mean: 0.3307 +/- 0.0094 rms: 0.0123 +/- 0.0067
hostname:sdfmilan204 rank:001 cpu:027 cmt:8p-v5 proc time (sec) mean: 0.3398 +/- 0.0044 rms: 0.0066 +/- 0.0031
hostname:sdfmilan204 rank:002 cpu:038 cmt:8p-v5 proc time (sec) mean: 0.3395 +/- 0.0069 rms: 0.0096 +/- 0.0048
hostname:sdfmilan204 rank:003 cpu:063 cmt:8p-v5 proc time (sec) mean: 0.3330 +/- 0.0037 rms: 0.0049 +/- 0.0026
hostname:sdfmilan204 rank:004 cpu:076 cmt:8p-v5 proc time (sec) mean: 0.3197 +/- 0.0054 rms: 0.0087 +/- 0.0039
hostname:sdfmilan204 rank:005 cpu:086 cmt:8p-v5 proc time (sec) mean: 0.3179 +/- 0.0049 rms: 0.0062 +/- 0.0035
hostname:sdfmilan204 rank:006 cpu:098 cmt:8p-v5 proc time (sec) mean: 0.3175 +/- 0.0063 rms: 0.0097 +/- 0.0045
hostname:sdfmilan204 rank:007 cpu:117 cmt:8p-v5 proc time (sec) mean: 0.3227 +/- 0.0085 rms: 0.0104 +/- 0.0060
hostname:sdfmilan204 rank:008 cpu:009 cmt:8p-v5 proc time (sec) mean: 0.3388 +/- 0.0056 rms: 0.0077 +/- 0.0040
hostname:sdfmilan204 rank:009 cpu:030 cmt:8p-v5 proc time (sec) mean: 0.3392 +/- 0.0041 rms: 0.0059 +/- 0.0029
hostname:sdfmilan204 rank:010 cpu:044 cmt:8p-v5 proc time (sec) mean: 0.3341 +/- 0.0090 rms: 0.0127 +/- 0.0064
hostname:sdfmilan204 rank:011 cpu:049 cmt:8p-v5 proc time (sec) mean: 0.3366 +/- 0.0036 rms: 0.0044 +/- 0.0026
hostname:sdfmilan204 rank:012 cpu:072 cmt:8p-v5 proc time (sec) mean: 0.3161 +/- 0.0058 rms: 0.0082 +/- 0.0041
hostname:sdfmilan204 rank:013 cpu:084 cmt:8p-v5 proc time (sec) mean: 0.3174 +/- 0.0055 rms: 0.0084 +/- 0.0039
hostname:sdfmilan204 rank:014 cpu:109 cmt:8p-v5 proc time (sec) mean: 0.3216 +/- 0.0042 rms: 0.0064 +/- 0.0030
hostname:sdfmilan204 rank:015 cpu:125 cmt:8p-v5 proc time (sec) mean: 0.3168 +/- 0.0063 rms: 0.0092 +/- 0.0045
hostname:sdfmilan204 rank:016 cpu:008 cmt:8p-v5 proc time (sec) mean: 0.3353 +/- 0.0064 rms: 0.0075 +/- 0.0045
hostname:sdfmilan204 rank:017 cpu:031 cmt:8p-v5 proc time (sec) mean: 0.3447 +/- 0.0059 rms: 0.0071 +/- 0.0042
hostname:sdfmilan204 rank:018 cpu:036 cmt:8p-v5 proc time (sec) mean: 0.3414 +/- 0.0061 rms: 0.0093 +/- 0.0043
hostname:sdfmilan204 rank:019 cpu:059 cmt:8p-v5 proc time (sec) mean: 0.3345 +/- 0.0036 rms: 0.0043 +/- 0.0025
hostname:sdfmilan204 rank:020 cpu:078 cmt:8p-v5 proc time (sec) mean: 0.3242 +/- 0.0071 rms: 0.0098 +/- 0.0050
hostname:sdfmilan204 rank:021 cpu:089 cmt:8p-v5 proc time (sec) mean: 0.3185 +/- 0.0067 rms: 0.0104 +/- 0.0047
hostname:sdfmilan204 rank:022 cpu:105 cmt:8p-v5 proc time (sec) mean: 0.3194 +/- 0.0040 rms: 0.0057 +/- 0.0028
hostname:sdfmilan204 rank:023 cpu:116 cmt:8p-v5 proc time (sec) mean: 0.3154 +/- 0.0062 rms: 0.0081 +/- 0.0044
hostname:sdfmilan204 rank:024 cpu:007 cmt:8p-v5 proc time (sec) mean: 0.3317 +/- 0.0098 rms: 0.0126 +/- 0.0069
hostname:sdfmilan204 rank:025 cpu:025 cmt:8p-v5 proc time (sec) mean: 0.3408 +/- 0.0043 rms: 0.0064 +/- 0.0031
hostname:sdfmilan204 rank:026 cpu:047 cmt:8p-v5 proc time (sec) mean: 0.3354 +/- 0.0087 rms: 0.0133 +/- 0.0061
hostname:sdfmilan204 rank:027 cpu:061 cmt:8p-v5 proc time (sec) mean: 0.3337 +/- 0.0037 rms: 0.0048 +/- 0.0026
hostname:sdfmilan204 rank:028 cpu:070 cmt:8p-v5 proc time (sec) mean: 0.3261 +/- 0.0070 rms: 0.0088 +/- 0.0049
hostname:sdfmilan204 rank:029 cpu:091 cmt:8p-v5 proc time (sec) mean: 0.3221 +/- 0.0062 rms: 0.0093 +/- 0.0044
hostname:sdfmilan204 rank:030 cpu:104 cmt:8p-v5 proc time (sec) mean: 0.3214 +/- 0.0042 rms: 0.0062 +/- 0.0030
hostname:sdfmilan204 rank:031 cpu:124 cmt:8p-v5 proc time (sec) mean: 0.3183 +/- 0.0044 rms: 0.0058 +/- 0.0031
hostname:sdfmilan204 rank:032 cpu:004 cmt:8p-v5 proc time (sec) mean: 0.3361 +/- 0.0072 rms: 0.0092 +/- 0.0051
hostname:sdfmilan204 rank:033 cpu:031 cmt:8p-v5 proc time (sec) mean: 0.3440 +/- 0.0055 rms: 0.0075 +/- 0.0039
hostname:sdfmilan204 rank:034 cpu:040 cmt:8p-v5 proc time (sec) mean: 0.3362 +/- 0.0072 rms: 0.0086 +/- 0.0051
hostname:sdfmilan204 rank:035 cpu:052 cmt:8p-v5 proc time (sec) mean: 0.3302 +/- 0.0038 rms: 0.0056 +/- 0.0027
hostname:sdfmilan204 rank:036 cpu:067 cmt:8p-v5 proc time (sec) mean: 0.3172 +/- 0.0060 rms: 0.0091 +/- 0.0042
hostname:sdfmilan204 rank:037 cpu:081 cmt:8p-v5 proc time (sec) mean: 0.3191 +/- 0.0047 rms: 0.0065 +/- 0.0033
hostname:sdfmilan204 rank:038 cpu:106 cmt:8p-v5 proc time (sec) mean: 0.3185 +/- 0.0064 rms: 0.0100 +/- 0.0045
hostname:sdfmilan204 rank:039 cpu:115 cmt:8p-v5 proc time (sec) mean: 0.3181 +/- 0.0051 rms: 0.0066 +/- 0.0036
hostname:sdfmilan204 rank:040 cpu:013 cmt:8p-v5 proc time (sec) mean: 0.3335 +/- 0.0097 rms: 0.0127 +/- 0.0068
hostname:sdfmilan204 rank:041 cpu:024 cmt:8p-v5 proc time (sec) mean: 0.3394 +/- 0.0041 rms: 0.0059 +/- 0.0029
hostname:sdfmilan204 rank:042 cpu:039 cmt:8p-v5 proc time (sec) mean: 0.3345 +/- 0.0086 rms: 0.0131 +/- 0.0061
hostname:sdfmilan204 rank:043 cpu:056 cmt:8p-v5 proc time (sec) mean: 0.3317 +/- 0.0058 rms: 0.0080 +/- 0.0041
hostname:sdfmilan204 rank:044 cpu:068 cmt:8p-v5 proc time (sec) mean: 0.3190 +/- 0.0057 rms: 0.0087 +/- 0.0041
hostname:sdfmilan204 rank:045 cpu:085 cmt:8p-v5 proc time (sec) mean: 0.3183 +/- 0.0059 rms: 0.0094 +/- 0.0042
hostname:sdfmilan204 rank:046 cpu:102 cmt:8p-v5 proc time (sec) mean: 0.3187 +/- 0.0043 rms: 0.0059 +/- 0.0030
hostname:sdfmilan204 rank:047 cpu:120 cmt:8p-v5 proc time (sec) mean: 0.3237 +/- 0.0048 rms: 0.0070 +/- 0.0034
hostname:sdfmilan204 rank:048 cpu:006 cmt:8p-v5 proc time (sec) mean: 0.3327 +/- 0.0095 rms: 0.0129 +/- 0.0067
hostname:sdfmilan204 rank:049 cpu:026 cmt:8p-v5 proc time (sec) mean: 0.3399 +/- 0.0040 rms: 0.0057 +/- 0.0028
hostname:sdfmilan204 rank:050 cpu:033 cmt:8p-v5 proc time (sec) mean: 0.3339 +/- 0.0087 rms: 0.0117 +/- 0.0061
hostname:sdfmilan204 rank:051 cpu:057 cmt:8p-v5 proc time (sec) mean: 0.3351 +/- 0.0027 rms: 0.0030 +/- 0.0019
hostname:sdfmilan204 rank:052 cpu:065 cmt:8p-v5 proc time (sec) mean: 0.3190 +/- 0.0064 rms: 0.0098 +/- 0.0045
hostname:sdfmilan204 rank:053 cpu:090 cmt:8p-v5 proc time (sec) mean: 0.3159 +/- 0.0064 rms: 0.0092 +/- 0.0045
hostname:sdfmilan204 rank:054 cpu:107 cmt:8p-v5 proc time (sec) mean: 0.3224 +/- 0.0046 rms: 0.0073 +/- 0.0032
hostname:sdfmilan204 rank:055 cpu:121 cmt:8p-v5 proc time (sec) mean: 0.3204 +/- 0.0044 rms: 0.0067 +/- 0.0031
hostname:sdfmilan204 rank:056 cpu:015 cmt:8p-v5 proc time (sec) mean: 0.3329 +/- 0.0098 rms: 0.0123 +/- 0.0069
hostname:sdfmilan204 rank:057 cpu:028 cmt:8p-v5 proc time (sec) mean: 0.3405 +/- 0.0049 rms: 0.0074 +/- 0.0035
hostname:sdfmilan204 rank:058 cpu:037 cmt:8p-v5 proc time (sec) mean: 0.3337 +/- 0.0094 rms: 0.0132 +/- 0.0066
hostname:sdfmilan204 rank:059 cpu:050 cmt:8p-v5 proc time (sec) mean: 0.3309 +/- 0.0036 rms: 0.0051 +/- 0.0026
hostname:sdfmilan204 rank:060 cpu:077 cmt:8p-v5 proc time (sec) mean: 0.3178 +/- 0.0054 rms: 0.0084 +/- 0.0038
hostname:sdfmilan204 rank:061 cpu:087 cmt:8p-v5 proc time (sec) mean: 0.3194 +/- 0.0057 rms: 0.0085 +/- 0.0040
hostname:sdfmilan204 rank:062 cpu:096 cmt:8p-v5 proc time (sec) mean: 0.3220 +/- 0.0074 rms: 0.0104 +/- 0.0052
hostname:sdfmilan204 rank:063 cpu:118 cmt:8p-v5 proc time (sec) mean: 0.3177 +/- 0.0047 rms: 0.0060 +/- 0.0033
hostname:sdfmilan204 rank:064 cpu:003 cmt:8p-v5 proc time (sec) mean: 0.3348 +/- 0.0093 rms: 0.0141 +/- 0.0066
hostname:sdfmilan204 rank:065 cpu:046 cmt:8p-v5 proc time (sec) mean: 0.3346 +/- 0.0086 rms: 0.0130 +/- 0.0060
hostname:sdfmilan204 rank:066 cpu:041 cmt:8p-v5 proc time (sec) mean: 0.3343 +/- 0.0091 rms: 0.0135 +/- 0.0064
hostname:sdfmilan204 rank:067 cpu:054 cmt:8p-v5 proc time (sec) mean: 0.3298 +/- 0.0040 rms: 0.0057 +/- 0.0028
hostname:sdfmilan204 rank:068 cpu:075 cmt:8p-v5 proc time (sec) mean: 0.3212 +/- 0.0062 rms: 0.0087 +/- 0.0044
hostname:sdfmilan204 rank:069 cpu:088 cmt:8p-v5 proc time (sec) mean: 0.3184 +/- 0.0061 rms: 0.0093 +/- 0.0043
hostname:sdfmilan204 rank:070 cpu:098 cmt:8p-v5 proc time (sec) mean: 0.3204 +/- 0.0042 rms: 0.0064 +/- 0.0030
hostname:sdfmilan204 rank:071 cpu:120 cmt:8p-v5 proc time (sec) mean: 0.3162 +/- 0.0062 rms: 0.0086 +/- 0.0044
hostname:sdfmilan204 rank:072 cpu:001 cmt:8p-v5 proc time (sec) mean: 0.3386 +/- 0.0071 rms: 0.0095 +/- 0.0050
hostname:sdfmilan204 rank:073 cpu:035 cmt:8p-v5 proc time (sec) mean: 0.3384 +/- 0.0091 rms: 0.0141 +/- 0.0064
hostname:sdfmilan204 rank:074 cpu:042 cmt:8p-v5 proc time (sec) mean: 0.3369 +/- 0.0085 rms: 0.0135 +/- 0.0060
hostname:sdfmilan204 rank:075 cpu:055 cmt:8p-v5 proc time (sec) mean: 0.3371 +/- 0.0033 rms: 0.0041 +/- 0.0024
hostname:sdfmilan204 rank:076 cpu:069 cmt:8p-v5 proc time (sec) mean: 0.3157 +/- 0.0063 rms: 0.0086 +/- 0.0044
hostname:sdfmilan204 rank:077 cpu:094 cmt:8p-v5 proc time (sec) mean: 0.3186 +/- 0.0053 rms: 0.0070 +/- 0.0037
hostname:sdfmilan204 rank:078 cpu:097 cmt:8p-v5 proc time (sec) mean: 0.3190 +/- 0.0038 rms: 0.0053 +/- 0.0027
hostname:sdfmilan204 rank:079 cpu:127 cmt:8p-v5 proc time (sec) mean: 0.3168 +/- 0.0037 rms: 0.0043 +/- 0.0026
mean time (sec): 0.3276

old algorithm

new algorithm

new algorithm with loop over panels

Summary

Time, msec, per event per core

number of coresold algorithm←Ratio 80/1new algorithm v2←Ratio 80/1

new algorithm v2

with loop

←Ratio 80/1
1366127412721
807522.053811.393281.20

2024-03-04 comparison of the new algorithm of calib_jungfrau

Description

Test full time for processing of entire run

dataset 8-panel cxilx7422 -r232 -d CxiDs1.0:Jungfrau.0 

  • single-core runs over 380*80 events
  • 80-core job is running on 380 events per core
  • use ds.break_after(380*80) in stead of termination of each. rank after. reaching 380 events.

Better start-stop time definition:

  • skip 1-st event, because of time consumption overhead due to loading of calib constants
  • start time is preserved for the 1-st rank gettein 2-nd event
  • stop time for the last finishing rank 

Summary

Total processing time (sec) of 380*80=30400 events for 1 or 80 cores or 254*120=30480 for 120 cores

number of coresold algorithm←Ratio t1/tNnew algorithm v2←Ratio t1/tNnew algorithm v2 with loop←Ratio t1/tN

1

11102

1

8425

1

8570

1

80281
175.4
170.650.2
Ratio t1/t80
39.5
48.0

80 - better

start-stop time def,

times for 3 jobs:

average: 

418.3

408.4

401.0

409.2





157.4

165.1

168.4

163.6




1

148.6

148.2

147.7

148.2





Ratio t1/t80

better start-stop


27.1


51.5


57.8 of 80

120

times for 3 jobs:

average: 

252.3

250.4

266.7

256.5


131.2

132.0

132.0

131.7


120.4

120.5

121.6

120.8


Ratio t1/t120


43.3


64.0


70.9 of 120

2024-03-08 time consumption by the calib_jungfrau_v2 algorithm

Description

Code of calib_jungfrau_v2 is interlaces with timestamps. The list of timestamps is returned along with calibrated array. 

Code of calib_jungfrau_v2 with time stamps
def calib_jungfrau_v2(det, evt, cmpars=(7,3,200,10), **kwa):
    """
    v2 - improving performance, reduce time and memory consumption, use peds-offset constants
    Returns calibrated jungfrau data

    - gets constants
    - gets raw data
    - evaluates (code - pedestal - offset)
    - applys common mode correction if turned on
    - apply gain factor

    Parameters

    - det (psana.Detector) - Detector object
    - evt (psana.Event)    - Event object
    - cmpars (tuple) - common mode parameters
        - cmpars[0] - algorithm # 7-for jungfrau
        - cmpars[1] - control bit-word 1-in rows, 2-in columns
        - cmpars[2] - maximal applied correction
    - **kwa - used here and passed to det.mask_v2 or det.mask_comb
      - nda_raw - if not None, substitutes evt.raw()
      - mbits - DEPRECATED parameter of the det.mask_comb(...)
      - mask - user defined mask passed as optional parameter
    """

    t00 = time()

    src = det.source # - src (psana.Source) - Source object

    nda_raw = kwa.get('nda_raw', None)
    loop_segs = kwa.get('loop_segs', False)
    arr = det.raw(evt) if nda_raw is None else nda_raw # shape:(<npanels>, 512, 1024) dtype:uint16
    if arr is None: return None

    t01 = time()

    detname = string_from_source(det.source)

    t02 = time()

    odc = cache.detcache_for_detname(detname)

    t03 = time()

    first_entry = odc is None
    if first_entry:
       odc = cache.add_detcache(det, evt)
       odc.cmps = det.common_mode(evt) if cmpars is None else cmpars
       odc.mask = det.mask_total(evt, **kwa)

    poff = odc.poff # 4d pedestals + offset shape:(3, 1, 512, 1024) dtype:float32
    gfac = odc.gfac # 4d gain factors evaluated form gains
    mask = odc.mask
    outa = odc.outa
    cmps = odc.cmps

    t04 = time()

    if first_entry:
        logger.info('\n  ====================== det.name: %s' % det.name\
                   +'\n  detname from source: %s' % string_from_source(det.source)\
                   +info_ndarr(arr,  '\n  calib_jungfrau arr ')\
                   +info_ndarr(poff, '\n  calib_jungfrau peds+off')\
                   +info_ndarr(gfac, '\n  calib_jungfrau gfac')\
                   +info_ndarr(mask, '\n  calib_jungfrau mask')\
                   +info_ndarr(outa, '\n  calib_jungfrau outa')\
                   +info_ndarr(cmps, '\n  calib_jungfrau common mode parameters ')
                   +'\n    loop over segments: %s' % loop_segs)

    if loop_segs:
      nsegs = arr.shape[0]
      shseg = arr.shape[-2:] # (512, 1024)
      for i in range(nsegs):
        arr1  = arr[i,:]
        mask1 = mask[i,:]
        gfac1 = gfac[:,i,:,:]
        poff1 = poff[:,i,:,:]
        arr1.shape  = (1,) + shseg
        mask1.shape = (1,) + shseg
        gfac1.shape = (3,1,) + shseg
        poff1.shape = (3,1,) + shseg
        out1, times = calib_jungfrau_single_panel(arr1, gfac1, poff1, mask1, cmps)
        outa[i,:] = out1[0,:]

      resp = outa

    else:
      resp, times = calib_jungfrau_single_panel(arr, gfac, poff, mask, cmps)

    t17 = time()
    times = (t00, t01, t02, t03, t04) + times + (t17,)
    return resp, np.array(times, dtype=np.float64)


def calib_jungfrau_single_panel(arr, gfac, poff, mask, cmps):
    """ Arrays should have a single panel shape, example for 8-panel detector
    arr:  shape:(8, 512, 1024) size:4194304 dtype:uint16 [2906 2945 2813 2861 3093...]
    poff: shape:(3, 8, 512, 1024) size:12582912 dtype:float32 [2922.283 2938.098 2827.207 2855.296 3080.415...]
    gfac: shape:(3, 8, 512, 1024) size:12582912 dtype:float32 [0.02490437 0.02543429 0.02541406 0.02539831 0.02544083...]
    mask: shape:(8, 512, 1024) size:4194304 dtype:uint8 [1 1 1 1 1...]
    cmps: shape:(16,) size:16 dtype:float64 [  7.   1. 100.   0.   0....]
    """

    t05 = time()

    # Define bool arrays of ranges
    gr0 = arr <  BW1              # 490 us
    gr1 =(arr >= BW1) & (arr<BW2) # 714 us
    gr2 = arr >= BW3              # 400 us

    t06 = time()

    factor = np.select((gr0, gr1, gr2), (gfac[0,:], gfac[1,:], gfac[2,:]), default=1) # 2msec

    t07 = time()

    pedoff = np.select((gr0, gr1, gr2), (poff[0,:], poff[1,:], poff[2,:]), default=0)

    t08 = time()

    # Subtract offset-corrected pedestals
    arrf = np.array(arr & MSK, dtype=np.float32)

    t09 = time()

    arrf -= pedoff

    t10 = time()

    if cmps is not None:
      mode, cormax = int(cmps[1]), cmps[2]
      npixmin = cmps[3] if len(cmps)>3 else 10
      if mode>0:
        #arr1 = store.arr1
        #grhg = np.select((gr0,  gr1), (arr1, arr1), default=0)
        logger.debug(info_ndarr(gr0, 'gain group0'))
        logger.debug(info_ndarr(mask, 'mask'))
        t0_sec_cm = time()

        t11 = time()
        gmask = np.bitwise_and(gr0, mask) if mask is not None else gr0

        t12 = time()

        #sh = (nsegs, 512, 1024)
        hrows = 256 #512/2

        for s in range(arrf.shape[0]):

          t13 = time()

          if mode & 4: # in banks: (512/2,1024/16) = (256,64) pixels # 100 ms
            common_mode_2d_hsplit_nbanks(arrf[s,:hrows,:], mask=gmask[s,:hrows,:], nbanks=16, cormax=cormax, npix_min=npixmin)
            common_mode_2d_hsplit_nbanks(arrf[s,hrows:,:], mask=gmask[s,hrows:,:], nbanks=16, cormax=cormax, npix_min=npixmin)

          t14 = time()

          if mode & 1: # in rows per bank: 1024/16 = 64 pixels # 275 ms
            common_mode_rows_hsplit_nbanks(arrf[s,], mask=gmask[s,], nbanks=16, cormax=cormax, npix_min=npixmin)

          t15 = time()

          if mode & 2: # in cols per bank: 512/2 = 256 pixels  # 290 ms
            common_mode_cols(arrf[s,:hrows,:], mask=gmask[s,:hrows,:], cormax=cormax, npix_min=npixmin)
            common_mode_cols(arrf[s,hrows:,:], mask=gmask[s,hrows:,:], cormax=cormax, npix_min=npixmin)

        logger.debug('TIME: common-mode correction time = %.6f sec' % (time()-t0_sec_cm))

    t16 = time()

    arrf = arrf * factor if mask is None else arrf * factor * mask # gain correction

    return arrf, (t05, t06, t07, t08, t09, t10, t11, t12, t13, t14, t15, t16)

Results

time differences between timestamps are shown in msec, as dt[i] = t[i]-t[i-1]

Time consumption of the calib_jungfrau_v2 parts
ana-4.0.59-py3 [dubrovin@sdfmilan204:~/LCLS/con-py3]$ mpirun -n 1 python  Detector/examples/test-scaling-mpi.py 6
execute command: ['Detector/examples/test-scaling-mpi.py', '6']
rank:000 cpu_num:000 size:01
[I] L0398: test-scaling-mpi.py 
  ====================== det.name: CxiDs1.0:Jungfrau.0
  detname from source: CxiDs1.0:Jungfrau.0
  calib_jungfrau arr  shape:(8, 512, 1024) size:4194304 dtype:uint16 [2906 2945 2813 2861 3093...]
  calib_jungfrau peds+off shape:(3, 8, 512, 1024) size:12582912 dtype:float32 [2922.283 2938.098 2827.207 2855.296 3080.415...]
  calib_jungfrau gfac shape:(3, 8, 512, 1024) size:12582912 dtype:float32 [0.02490437 0.02543429 0.02541406 0.02539831 0.02544083...]
  calib_jungfrau mask shape:(8, 512, 1024) size:4194304 dtype:uint8 [1 1 1 1 1...]
  calib_jungfrau outa shape:(8, 512, 1024) size:4194304 dtype:float32 [0. 0. 0. 0. 0....]ndarray from tuple: 
  calib_jungfrau common mode parameters  shape:(4,) size:4 dtype:int64 [  7   7 200  10]
    loop over segments: False
rank:000 cpu_num:000 nevt:0000 time:10.075316
[I] L0607: test-scaling-mpi.py rank:000 job 2-nd evt time:1710175768.956751 saveed in file: figs/mpi-job-2nd-evt-time.txt
rank:000 cpu_num:000 nevt:0010 time:0.578157
rank:000 cpu_num:000 nevt:0020 time:0.541390
rank:000 cpu_num:000 nevt:0030 time:0.518435
rank:000 cpu_num:000 nevt:0040 time:0.575237
rank:000 cpu_num:000 nevt:0050 time:0.577683
rank:000 cpu_num:000 nevt:0060 time:0.580110
rank:000 cpu_num:000 nevt:0070 time:0.579042
rank:000 cpu_num:000 nevt:0080 time:0.577012
rank:000 cpu_num:000 nevt:0090 time:0.577242
rank:000 cpu_num:000 nevt:0100 time:0.575845
[I] L0640: test-scaling-mpi.py Summary for rank:000 job 2-nd evt time:1710175768.956751 time total (sec):64.189028
...
QStandardPaths: XDG_RUNTIME_DIR not set, defaulting to '/tmp/runtime-dubrovin'
hostname:sdfmilan204 rank:000 cpu:000 cmt:8p-v6 proc time (sec) mean: 0.5668 +/- 0.0125 rms: 0.0186 +/- 0.0088

plot_figs_v2
fnprefix: figs/fig-mpi-data-8p-v6-sdfmilan204-ncores01 title: sdfmilan204 rank 000 of 001 cpu_num 000
...
000  1709951462.307   0.896   0.019   0.008   0.003   0.001   1.485   5.141   4.795   1.873   1.081   0.389   0.712 552.819  11.156  31.449  35.934   3.994
001  1709951462.963   0.883   0.015   0.003   0.002   0.001   1.478   5.195   4.963   1.878   1.216   0.269   0.686 553.074  11.234  31.461  36.158   3.678
002  1709951463.620   0.736   0.013   0.003   0.001   0.000   1.325   5.175   4.901   1.848   1.186   0.268   0.700 556.101  10.969  31.402  35.841   2.868
003  1709951464.278   0.672   0.014   0.003   0.001   0.001   1.491   5.275   4.833   1.874   1.156   0.271   0.695 555.187  11.171  31.454  36.028   3.687
004  1709951464.935   0.672   0.015   0.003   0.001   0.001   1.407   5.255   4.980   1.860   1.188   0.265   0.681 556.062  11.451  31.451  35.880   4.575
005  1709951465.599   1.828   0.014   0.004   0.001   0.000   2.680   5.197   5.440   3.114   1.231   0.275   1.372 552.135  11.523  31.402  35.908   3.678
006  1709951466.259   0.675   0.016   0.003   0.001   0.001   1.370   5.214   4.860   1.832   1.193   0.278   0.691 552.219  11.224  31.394  36.250   3.223
007  1709951466.914   0.873   0.022   0.008   0.002   0.001   1.367   5.303   5.026   1.864   1.209   0.363   0.718 551.416  11.165  31.385  36.066   4.027
008  1709951467.569   0.842   0.014   0.003   0.001   0.001   1.389   5.209   4.796   1.854   1.119   0.264   0.699 551.404  11.150  31.370  36.021   2.912
009  1709951468.223   0.838   0.014   0.003   0.001   0.001   1.381   5.234   4.893   1.874   1.191   0.264   0.690 554.368  11.403  31.414  35.849   5.744
010  1709951468.886   1.976   0.014   0.003   0.001   0.001   3.203   5.134   5.291   3.050   1.211   0.310   0.857 556.652  11.083  31.411  35.851   2.866
011  1709951469.550   0.858   0.016   0.003   0.001   0.001   1.345   5.208   4.876   1.868   1.172   0.266   0.656 554.571  11.404  31.372  35.806   3.667
012  1709951470.207   0.782   0.015   0.003   0.001   0.000   1.321   5.140   4.890   1.849   1.178   0.276   0.671 552.930  11.304  31.376  35.908   3.159
013  1709951470.863   0.902   0.021   0.009   0.002   0.001   1.363   5.316   5.044   1.849   1.206   0.368   0.675 551.805  11.463  31.375  35.844   3.764
014  1709951471.518   0.880   0.014   0.003   0.001   0.001   1.352   5.144   4.876   1.856   1.161   0.269   0.696 551.738  11.189  31.328  36.213   2.871
015  1709951472.172   0.675   0.015   0.003   0.001   0.001   1.365   5.187   4.965   1.848   1.222   0.276   0.686 554.584  11.385  31.463  35.826   5.604
016  1709951472.835   1.795   0.014   0.003   0.001   0.001   3.175   5.209   5.346   3.035   1.211   0.305   1.116 553.065  11.606  31.393  35.818   2.867
017  1709951473.495   0.679   0.014   0.003   0.001   0.001   1.370   5.263   4.933   1.799   1.271   0.279   0.690 555.862  11.446  31.403  36.174   3.659
018  1709951474.154   0.793   0.013   0.003   0.001   0.000   1.343   5.124   4.980   1.845   1.195   0.269   0.686 553.584  11.318  31.364  35.820   2.865
019  1709951474.810   0.783   0.014   0.004   0.001   0.001   1.342   5.148   4.929   1.868   1.203   0.270   0.695 554.589  11.329  31.414  36.334   3.758
020  1709951475.469   0.759   0.021   0.010   0.002   0.001   1.384   5.295   5.002   1.847   1.193   0.370   0.680 552.323  10.995  31.373  36.190   3.232
021  1709951476.124   0.789   0.014   0.003   0.001   0.001   1.334   5.149   4.863   1.873   1.159   0.262   0.694 551.174  11.586  31.429  36.093   3.683
022  1709951476.778   0.678   0.017   0.003   0.001   0.001   1.357   5.206   4.942   1.861   1.139   0.263   0.607 552.973  11.487  31.450  36.206   2.861
023  1709951477.434   0.829   0.014   0.004   0.001   0.001   1.348   5.168   4.786   1.909   1.113   0.262   0.706 556.439  11.474  31.396  35.960   5.616
024  1709951478.098   1.973   0.014   0.003   0.001   0.001   3.199   5.158   5.316   3.041   1.199   0.301   0.712 552.752  11.263  31.464  35.887   2.860
025  1709951478.758   0.863   0.014   0.003   0.001   0.001   1.356   5.180   4.890   1.876   1.167   0.269   0.661 554.007  11.324  31.501  35.965   3.695
026  1709951479.415   0.732   0.014   0.004   0.001   0.001   1.335   5.185   4.794   1.839   1.143   0.273   0.693 556.165  11.355  31.592  35.691   2.909
027  1709951480.073   0.819   0.014   0.003   0.001   0.001   1.350   5.151   4.818   1.882   1.267   0.249   0.675 554.184  11.207  31.441  37.435   3.780
028  1709951480.732   0.796   0.021   0.009   0.002   0.001   1.341   5.367   5.031   1.855   1.180   0.367   0.683 552.998  11.480  31.440  36.413   3.181
029  1709951481.389   0.770   0.014   0.003   0.001   0.001   1.347   5.169   4.633   1.886   1.028   0.263   0.737 551.741  11.409  31.451  36.130   3.669
030  1709951482.044   0.798   0.014   0.002   0.001   0.001   1.347   5.197   4.551   1.838   0.988   0.286   0.742 552.585  11.286  31.398  36.214   2.938
031  1709951482.705   0.780   0.013   0.003   0.001   0.001   1.319   5.225   4.844   1.896   1.138   0.273   0.686 551.471  11.422  31.405  36.418   3.673
032  1709951483.360   0.744   0.015   0.003   0.001   0.001   1.364   5.174   5.049   1.848   1.197   0.271   0.690 555.717  11.567  31.450  36.004   4.597
033  1709951484.024   1.865   0.014   0.003   0.001   0.001   3.177   5.151   5.408   3.073   1.192   0.302   0.859 551.751  11.420  31.518  36.076   3.935
034  1709951484.684   0.763   0.013   0.003   0.001   0.001   1.366   5.156   4.923   1.836   1.180   0.270   0.654 553.017  11.105  31.419  39.409   2.934
035  1709951485.343   0.744   0.013   0.007   0.001   0.001   1.339   5.207   4.864   1.884   1.127   0.268   0.715 552.273  11.389  31.421  36.091   3.676
036  1709951485.998   0.783   0.015   0.002   0.001   0.000   1.353   5.147   4.905   1.826   1.190   0.268   0.676 553.218  11.577  31.411  36.138   2.858
037  1709951486.654   0.825   0.014   0.003   0.001   0.001   1.353   5.150   4.901   1.883   1.196   0.278   0.677 553.971  11.355  31.408  36.152   3.771
038  1709951487.312   0.751   0.023   0.009   0.002   0.001   1.380   5.332   5.054   1.862   1.162   0.368   0.659 552.360  11.561  31.421  35.896   3.161
039  1709951487.967   0.674   0.013   0.004   0.001   0.000   1.400   5.185   4.996   1.900   1.302   0.254   0.668 551.565  11.267  31.442  36.180   3.667
040  1709951488.622   0.834   0.014   0.003   0.001   0.001   1.353   5.120   4.946   1.814   1.219   0.290   0.681 552.905  11.643  31.436  35.873   2.932
041  1709951489.277   0.678   0.014   0.003   0.001   0.001   1.372   5.282   4.882   1.873   1.193   0.274   0.710 552.397  11.231  31.636  35.957   3.679
042  1709951489.933   0.833   0.014   0.003   0.001   0.001   1.350   5.175   4.920   1.853   1.181   0.268   0.666 556.858  11.618  31.441  36.003   2.847
043  1709951490.593   0.840   0.014   0.003   0.001   0.001   1.358   5.231   4.746   1.896   1.068   0.262   0.703 555.706  11.318  31.440  35.805   5.592
044  1709951491.256   1.952   0.014   0.003   0.002   0.005   3.188   5.193   5.317   3.031   1.187   0.306   0.767 552.667  11.568  31.327  35.856   2.917
045  1709951491.918   0.880   0.014   0.004   0.001   0.001   1.378   5.135   4.664   1.875   1.036   0.266   0.731 551.976  11.368  31.469  36.103   3.685
046  1709951492.573   0.842   0.014   0.003   0.001   0.001   1.362   5.220   4.928   1.821   1.194   0.281   0.673 553.601  11.359  31.435  35.888   2.857
047  1709951493.229   0.771   0.013   0.003   0.001   0.001   1.374   5.173   4.786   1.860   1.136   0.269   0.694 552.346  11.322  31.404  35.964   3.676
048  1709951493.884   0.738   0.015   0.003   0.001   0.001   1.352   5.152   4.954   1.839   1.420   0.273   0.638 552.455  11.343  31.405  35.867   2.919
049  1709951494.539   0.735   0.014   0.003   0.001   0.001   1.350   5.213   4.919   1.858   1.203   0.267   0.684 555.511  11.320  31.425  36.101   3.734
050  1709951495.199   0.792   0.021   0.010   0.002   0.001   1.350   5.295   4.967   1.875   1.159   0.362   0.695 555.633  11.365  31.427  35.871   3.206
051  1709951495.858   0.725   0.014   0.003   0.001   0.001   1.355   5.179   4.966   1.855   1.193   0.267   0.663 552.571  11.290  31.442  36.051   3.706
052  1709951496.513   0.732   0.014   0.003   0.001   0.001   1.351   5.148   4.894   1.835   1.204   0.268   0.691 553.878  11.168  31.355  35.997   2.867
053  1709951497.169   0.884   0.015   0.003   0.001   0.000   1.359   5.130   4.803   1.873   1.126   0.268   0.679 552.045  11.216  31.336  35.805   3.684
054  1709951497.824   0.789   0.014   0.004   0.001   0.001   1.342   5.153   4.969   1.838   1.198   0.277   0.669 552.754  11.168  31.354  35.906   2.863
055  1709951498.479   0.699   0.014   0.003   0.001   0.001   1.379   5.230   4.929   1.879   1.177   0.276   0.626 551.721  11.107  31.259  35.795   3.709
056  1709951499.133   0.754   0.013   0.003   0.001   0.001   1.346   5.166   4.931   1.846   1.201   0.276   0.641 553.559  11.420  31.302  36.263   4.534
057  1709951499.795   1.892   0.014   0.004   0.001   0.001   3.194   5.144   5.213   3.070   1.102   0.313   0.883 552.342  11.358  31.356  35.834   3.947
058  1709951500.455   0.805   0.013   0.003   0.002   0.001   1.321   5.237   4.941   1.871   1.189   0.272   0.689 553.453  11.569  31.407  35.818   2.918
059  1709951501.111   0.843   0.015   0.003   0.001   0.001   1.343   5.250   4.936   1.879   1.151   0.264   0.641 555.424  11.339  32.551  35.822   3.683
060  1709951501.775   0.839   0.013   0.003   0.001   0.001   1.346   5.242   4.981   1.867   1.173   0.274   0.686 553.788  11.635  31.384  35.812   2.853
061  1709951502.432   0.756   0.013   0.003   0.001   0.001   1.360   5.247   4.971   1.871   1.191   0.264   0.652 551.001  11.677  31.382  36.142   3.688
062  1709951503.087   0.831   0.015   0.004   0.001   0.001   1.340   5.271   4.916   1.837   1.315   0.244   0.620 551.165  11.508  31.385  35.914   2.868
063  1709951503.741   0.812   0.015   0.003   0.002   0.000   1.352   5.172   4.941   2.346   1.167   0.271   0.684 553.406  11.084  31.473  35.871   3.790
064  1709951504.398   0.852   0.020   0.010   0.002   0.001   1.330   5.253   4.844   1.855   1.074   0.364   0.710 551.497  11.369  31.465  35.813   3.201
065  1709951505.052   0.858   0.013   0.003   0.001   0.001   1.350   5.165   4.972   1.875   1.328   0.241   0.646 550.681  11.250  31.382  35.781   3.694
066  1709951505.706   0.758   0.015   0.003   0.001   0.001   1.349   5.157   4.908   1.836   1.194   0.274   0.675 551.458  11.241  32.197  36.151   2.866
067  1709951506.361   0.741   0.014   0.004   0.001   0.001   1.340   5.150   4.874   1.872   1.164   0.268   0.691 553.973  11.016  31.438  36.056   3.660
068  1709951507.018   0.807   0.015   0.003   0.001   0.001   1.329   5.279   4.790   1.841   1.065   0.263   0.660 553.581  11.266  31.376  35.834   2.949
069  1709951507.674   0.787   0.014   0.003   0.001   0.000   1.334   5.126   4.892   1.881   1.157   0.268   0.637 554.552  11.103  31.501  36.175   3.676
070  1709951508.331   0.734   0.014   0.003   0.001   0.001   1.357   5.187   4.900   1.847   1.182   0.290   0.680 552.080  11.193  31.472  35.965   2.924
071  1709951508.986   0.918   0.014   0.003   0.001   0.001   1.399   5.111   4.948   1.878   1.180   0.273   0.678 552.339  11.160  31.449  38.325   5.545
072  1709951509.648   1.889   0.016   0.003   0.001   0.001   3.175   5.211   5.360   3.035   1.554   0.392   1.726 552.022  11.255  31.424  36.042   2.904
073  1709951510.309   0.870   0.015   0.003   0.001   0.001   1.353   5.160   4.832   1.892   1.129   0.276   0.626 551.263  11.202  31.387  36.047   3.684
074  1709951510.963   0.827   0.013   0.003   0.001   0.001   1.338   5.287   4.996   1.806   1.233   0.277   0.686 552.124  11.490  31.376  35.786   2.860
075  1709951511.618   0.840   0.014   0.003   0.001   0.001   1.317   5.194   4.713   1.892   1.059   0.266   0.633 556.157  11.050  31.419  35.863   3.686
076  1709951512.276   0.793   0.013   0.002   0.001   0.001   1.337   5.218   4.824   1.847   1.163   0.273   0.627 553.038  11.441  31.399  36.186   2.922
077  1709951512.932   0.860   0.013   0.003   0.002   0.001   1.341   5.239   4.809   1.879   1.132   0.264   0.633 553.340  11.380  31.325  35.777   3.681
078  1709951513.588   0.806   0.013   0.003   0.001   0.001   1.337   5.150   4.858   1.859   1.164   0.271   0.625 552.434  11.174  31.342  35.875   2.861
079  1709951514.242   0.770   0.014   0.003   0.001   0.001   1.328   5.261   4.904   1.884   1.201   0.278   0.675 552.390  11.277  31.314  36.119   3.900
080  1709951514.898   0.819   0.013   0.003   0.001   0.001   1.318   5.177   4.884   1.860   1.179   0.265   0.685 552.436  11.178  31.398  36.157   3.146
081  1709951515.553   0.855   0.020   0.009   0.002   0.001   1.342   5.287   5.025   1.875   1.196   0.365   0.692 551.800  11.389  31.425  36.143   3.788
082  1709951516.208   0.848   0.013   0.003   0.001   0.001   1.342   5.195   4.701   1.853   1.053   0.286   0.722 552.828  11.556  31.430  36.204   2.869
083  1709951516.864   0.887   0.014   0.003   0.001   0.001   1.360   5.119   4.796   1.879   0.997   0.262   0.692 556.199  11.292  31.449  36.011   3.677
084  1709951517.523   0.803   0.013   0.003   0.001   0.001   1.320   5.174   4.836   1.863   1.142   0.268   0.697 554.992  11.651  31.435  36.045   2.867
085  1709951518.180   0.872   0.014   0.003   0.001   0.001   1.356   5.264   4.562   1.873   1.000   0.256   0.732 552.314  11.364  31.386  36.011   3.661
086  1709951518.835   0.752   0.014   0.003   0.001   0.000   1.347   5.221   4.898   1.843   1.160   0.260   0.624 552.631  11.247  31.341  35.831   2.864
087  1709951519.490   0.789   0.013   0.003   0.002   0.000   1.338   5.193   4.737   1.894   1.049   0.262   0.695 552.360  11.667  31.430  36.007   3.717
088  1709951520.145   0.778   0.015   0.003   0.001   0.001   1.374   5.197   4.914   1.870   1.151   0.273   0.693 551.128  11.247  31.365  36.042   2.918
089  1709951520.799   0.780   0.014   0.003   0.001   0.001   1.332   5.203   4.920   1.879   1.057   0.261   0.717 552.486  11.064  31.368  35.817   3.692
090  1709951521.454   0.809   0.014   0.003   0.001   0.001   1.336   5.174   4.876   1.850   1.136   0.291   0.638 552.596  11.177  31.420  35.792   4.503
091  1709951522.114   1.924   0.014   0.003   0.001   0.001   3.204   5.130   5.308   3.101   1.187   0.305   1.203 552.445  15.121  31.392  36.129   3.931
092  1709951522.779   0.776   0.014   0.003   0.001   0.001   1.350   5.167   4.806   1.852   1.130   0.266   0.650 552.923  11.227  31.414  35.848   2.917
093  1709951523.434   0.863   0.015   0.003   0.001   0.001   1.354   5.155   4.900   1.870   1.303   0.237   0.600 553.494  11.353  31.414  35.815   3.677
094  1709951524.090   0.699   0.015   0.003   0.001   0.001   1.344   5.153   4.925   1.835   1.213   0.278   0.668 550.517  11.584  31.425  35.820   2.866
095  1709951524.744   0.896   0.013   0.003   0.002   0.001   1.376   5.210   5.044   1.849   1.206   0.274   0.690 551.603  11.192  31.399  36.161   3.706
096  1709951525.399   0.849   0.013   0.003   0.001   0.001   1.333   5.183   4.539   1.844   0.974   0.251   0.723 552.818  11.143  31.449  35.790   2.860
097  1709951526.054   0.858   0.014   0.003   0.001   0.001   1.331   5.178   4.903   1.882   1.147   0.266   0.648 552.017  11.579  31.375  35.923   3.667
098  1709951526.709   0.861   0.013   0.003   0.001   0.001   1.337   5.155   4.961   1.824   1.199   0.274   0.676 551.453  11.124  31.403  35.890   2.867
099  1709951527.363   0.871   0.015   0.003   0.001   0.001   1.380   5.244   4.905   1.872   1.201   0.279   0.670 551.980  11.592  31.406  36.138   3.706
evt  t00(sec)    ms:  t01     t02     t03     t04     t05     t06     t07     t08     t09     t10     t11     t12     t13     t14     t15     t16     t17
job #1 median:        0.808   0.014   0.003   0.001   0.001   1.352   5.186   4.907   1.868   1.180   0.271   0.686 552.710  11.327  31.412  35.965   3.667
other jobs
job #2 median:        0.820   0.013   0.003   0.001   0.001   1.324   5.312   4.984   1.796   1.146   0.231   0.681 551.307  11.269  31.356  35.863   2.910
job #3 median:        0.773   0.014   0.003   0.001   0.001   1.355   5.325   4.983   1.720   1.158   0.267   0.677 548.701  11.053  31.174  35.818   3.001
job #4 median:        0.664   0.015   0.003   0.002   0.001   1.408   5.339   5.003   1.726   1.194   0.272   0.685 548.775  11.112  31.168  35.857   3.215
job #5 median:        0.804   0.014   0.003   0.001   0.001   1.315   5.293   4.972   1.736   1.153   0.274   0.674 551.204  11.219  31.334  35.955   2.873
calib_jungfrau_v2 with loops over segments
ana-4.0.59-py3 [dubrovin@sdfmilan204:~/LCLS/con-py3]$ mpirun -n 1 python  Detector/examples/test-scaling-mpi.py 7
rank:000 cpu_num:000 size:01
[I] L0398: test-scaling-mpi.py 
  ====================== det.name: CxiDs1.0:Jungfrau.0
  detname from source: CxiDs1.0:Jungfrau.0
  calib_jungfrau arr  shape:(8, 512, 1024) size:4194304 dtype:uint16 [2906 2945 2813 2861 3093...]
  calib_jungfrau peds+off shape:(3, 8, 512, 1024) size:12582912 dtype:float32 [2922.283 2938.098 2827.207 2855.296 3080.415...]
  calib_jungfrau gfac shape:(3, 8, 512, 1024) size:12582912 dtype:float32 [0.02490437 0.02543429 0.02541406 0.02539831 0.02544083...]
  calib_jungfrau mask shape:(8, 512, 1024) size:4194304 dtype:uint8 [1 1 1 1 1...]
  calib_jungfrau outa shape:(8, 512, 1024) size:4194304 dtype:float32 [0. 0. 0. 0. 0....]ndarray from tuple: 
  calib_jungfrau common mode parameters  shape:(4,) size:4 dtype:int64 [  7   7 200  10]
    loop over segments: True
rank:000 cpu_num:000 nevt:0000 time:10.117775
[I] L0604: test-scaling-mpi.py rank:000 job 2-nd evt time:1710176925.177748 saveed in file: figs/mpi-job-2nd-evt-time.txt
rank:000 cpu_num:000 nevt:0010 time:0.586269
rank:000 cpu_num:000 nevt:0020 time:0.581187
rank:000 cpu_num:000 nevt:0030 time:0.579508
rank:000 cpu_num:000 nevt:0040 time:0.566666
rank:000 cpu_num:000 nevt:0050 time:0.580894
rank:000 cpu_num:000 nevt:0060 time:0.580464
rank:000 cpu_num:000 nevt:0070 time:0.579505
rank:000 cpu_num:000 nevt:0080 time:0.582394
rank:000 cpu_num:000 nevt:0090 time:0.579650
rank:000 cpu_num:000 nevt:0100 time:0.580779
[I] L0637: test-scaling-mpi.py Summary for rank:000 job 2-nd evt time:1710176925.177748 time total (sec):65.284561
rank:000 times: shape:(100,) size:100 dtype:float64
...
QStandardPaths: XDG_RUNTIME_DIR not set, defaulting to '/tmp/runtime-dubrovin'
hostname:sdfmilan204 rank:000 cpu:000 cmt:8p-v7 proc time (sec) mean: 0.5819 +/- 0.0051 rms: 0.0066 +/- 0.0036

plot_figs_v2
fnprefix: figs/fig-mpi-data-8p-v7-sdfmilan204-ncores01 title: sdfmilan204 rank 000 of 001 cpu_num 000
arrts[msec]: shape:(100, 18) size:1800 dtype:float64
...
000  1710176925.179   0.666   0.017   0.008   0.002 569.880   0.195   0.680   0.623   0.117   0.084   0.127   0.052   0.001  11.087  31.610  36.165   0.397
001  1710176925.835   0.638   0.018   0.003   0.002 571.524   0.194   0.707   0.637   0.119   0.083   0.132   0.054   0.001  11.149  31.636  35.907   0.396
002  1710176926.492   0.639   0.019   0.003   0.002 568.908   0.196   0.649   0.592   0.127   0.094   0.140   0.057   0.001  10.950  31.537  35.854   0.398
003  1710176927.147   0.633   0.019   0.003   0.002 568.563   0.201   0.649   0.601   0.117   0.083   0.130   0.056   0.001  10.769  31.551  36.225   0.401
004  1710176927.801   0.644   0.019   0.003   0.002 574.708   0.356   0.669   0.618   0.119   0.083   0.133   0.140   0.001  11.196  31.468  36.211   0.675
005  1710176928.465   1.722   0.018   0.003   0.001 568.464   0.195   0.674   0.592   0.117   0.083   0.132   0.056   0.001  11.315  31.503  35.888   0.401
006  1710176929.121   0.640   0.018   0.003   0.002 568.027   0.195   0.692   0.658   0.118   0.084   0.128   0.062   0.001  10.968  31.407  36.123   0.394
007  1710176929.775   0.638   0.023   0.012   0.002 569.959   0.192   0.603   0.678   0.118   0.083   0.130   0.056   0.001  10.919  31.392  35.939   0.395
008  1710176930.430   0.640   0.018   0.003   0.002 570.235   0.196   0.625   0.637   0.118   0.083   0.126   0.055   0.001  10.902  31.453  36.084   0.405
009  1710176931.086   0.637   0.018   0.003   0.001 572.507   0.353   0.658   0.603   0.118   0.084   0.133   0.140   0.002  11.013  31.432  37.417   0.677
010  1710176931.749   1.720   0.017   0.003   0.002 569.025   0.193   0.633   0.605   0.117   0.084   0.133   0.057   0.001  10.891  31.381  36.222   0.401
011  1710176932.405   0.635   0.017   0.003   0.001 567.340   0.194   0.634   0.612   0.125   0.083   0.127   0.056   0.001  11.194  31.417  35.845   0.399
012  1710176933.058   0.635   0.017   0.002   0.002 567.859   0.196   0.678   0.635   0.117   0.084   0.126   0.057   0.001  11.080  31.371  36.001   0.394
013  1710176933.712   0.636   0.024   0.013   0.002 566.197   0.194   0.657   0.603   0.117   0.083   0.133   0.058   0.001  11.233  31.371  36.247   0.403
014  1710176934.364   0.643   0.022   0.003   0.002 566.952   0.197   0.664   0.612   0.117   0.083   0.129   0.057   0.001  10.935  31.378  35.875   0.394
015  1710176935.016   0.635   0.018   0.003   0.002 569.362   0.510   0.626   0.861   0.127   0.083   0.154   0.136   0.001  11.003  31.729  36.294   0.671
016  1710176935.676   1.736   0.025   0.004   0.002 570.226   0.195   0.636   0.596   0.118   0.083   0.127   0.062   0.001  11.322  31.442  35.914   0.399
017  1710176936.337   0.637   0.018   0.002   0.002 567.089   0.192   0.650   0.592   0.300   0.083   0.129   0.057   0.001  11.218  31.405  35.914   0.393
018  1710176936.990   0.640   0.017   0.004   0.002 568.821   0.194   0.618   0.598   0.117   0.084   0.125   0.057   0.001  11.068  31.435  36.364   0.397
019  1710176937.645   0.642   0.017   0.003   0.002 567.523   0.196   0.665   0.636   0.119   0.083   0.127   0.057   0.001  11.117  31.384  35.998   0.395
020  1710176938.299   0.638   0.023   0.012   0.002 566.782   0.197   0.680   0.628   0.118   0.084   0.124   0.056   0.001  10.767  31.521  35.868   0.398
021  1710176938.951   0.636   0.018   0.003   0.001 565.609   0.193   0.610   0.607   0.118   0.084   0.126   0.057   0.002  11.339  31.319  36.009   0.394
022  1710176939.602   0.638   0.017   0.003   0.001 567.499   0.209   0.604   0.621   0.117   0.084   0.127   0.057   0.001  11.328  31.393  36.040   0.396
023  1710176940.256   0.635   0.019   0.004   0.002 573.105   0.353   0.679   0.609   0.118   0.091   0.127   0.141   0.001  11.096  31.372  36.344   0.681
024  1710176940.918   1.740   0.016   0.003   0.001 572.266   0.195   0.651   0.597   0.116   0.083   0.133   0.057   0.001  11.027  31.364  36.005   0.396
025  1710176941.577   0.631   0.018   0.003   0.001 567.538   0.192   0.631   0.591   0.125   0.084   0.125   0.057   0.001  11.003  31.337  35.894   0.396
026  1710176942.230   0.636   0.018   0.003   0.002 568.037   0.195   0.621   0.670   0.117   0.083   0.133   0.055   0.001  11.123  31.391  36.233   0.401
027  1710176942.884   0.636   0.018   0.003   0.001 567.989   0.193   0.635   0.677   0.127   0.084   0.126   0.056   0.001  10.962  31.390  35.895   0.398
028  1710176943.538   0.641   0.025   0.012   0.003 566.633   0.196   0.628   0.597   0.118   0.084   0.126   0.056   0.001  11.214  31.428  35.818   0.403
029  1710176944.190   0.635   0.017   0.003   0.002 565.870   0.192   0.648   0.610   0.117   0.089   0.124   0.057   0.001  11.144  31.362  35.860   0.395
030  1710176944.842   0.634   0.017   0.004   0.002 567.096   0.202   0.658   0.613   0.117   0.083   0.123   0.056   0.001  11.078  31.397  35.869   0.394
031  1710176945.494   0.629   0.018   0.003   0.001 566.641   0.195   0.649   0.607   0.118   0.083   0.133   0.057   0.001  11.119  31.346  36.274   0.401
032  1710176946.147   0.638   0.018   0.003   0.001 576.210   0.353   0.639   0.625   0.118   0.083   0.127   0.138   0.001  11.161  31.395  35.792   0.682
033  1710176946.812   1.721   0.018   0.003   0.002 567.965   0.192   0.614   0.622   0.117   0.083   0.131   0.057   0.001  11.197  31.366  35.955   0.394
034  1710176947.467   0.634   0.017   0.003   0.002 567.574   0.195   0.615   0.596   0.117   0.091   0.127   0.055   0.001  10.901  31.393  35.964   0.395
035  1710176948.120   0.635   0.017   0.003   0.001 540.194   0.195   0.662   0.509   0.100   0.070   0.107   0.050   0.001  10.365  28.301  34.414   0.394
036  1710176948.740   0.638   0.018   0.003   0.001 552.474   0.171   0.576   0.513   0.101   0.070   0.107   0.051   0.001  10.327  28.882  32.906   0.363
037  1710176949.372   0.607   0.017   0.003   0.002 547.162   0.194   0.664   0.616   0.118   0.083   0.136   0.065   0.001  10.803  31.229  35.949   0.402
038  1710176950.004   0.650   0.025   0.013   0.002 539.100   0.195   0.609   0.637   0.117   0.084   0.126   0.056   0.001  11.068  31.485  33.966   0.349
039  1710176950.627   0.606   0.016   0.002   0.002 554.036   0.169   0.542   0.518   0.105   0.071   0.120   0.065   0.001  10.410  29.793  32.797   0.351
040  1710176951.261   0.642   0.017   0.003   0.001 554.199   0.195   0.613   0.619   0.118   0.083   0.126   0.056   0.001  11.444  31.373  36.057   0.397
041  1710176951.902   0.631   0.024   0.003   0.002 570.335   0.194   0.641   0.595   0.118   0.083   0.135   0.057   0.001  10.968  31.413  35.979   0.393
042  1710176952.557   0.638   0.016   0.003   0.002 568.253   0.205   0.659   0.617   0.117   0.083   0.125   0.055   0.002  11.354  31.421  36.379   0.403
043  1710176953.212   0.636   0.017   0.003   0.002 570.688   0.349   0.694   0.612   0.127   0.084   0.125   0.137   0.001  10.998  31.364  35.868   0.677
044  1710176953.872   1.725   0.018   0.003   0.002 568.433   0.195   0.644   0.601   0.117   0.084   0.125   0.055   0.001  11.340  31.365  35.909   0.393
045  1710176954.528   0.631   0.018   0.003   0.001 566.346   0.194   0.655   0.607   0.117   0.083   0.128   0.061   0.001  11.143  31.315  35.884   0.393
046  1710176955.179   0.638   0.017   0.003   0.002 566.295   0.196   0.653   0.603   0.118   0.084   0.124   0.056   0.001  11.112  31.403  36.420   0.394
047  1710176955.832   0.632   0.017   0.004   0.002 565.378   0.193   0.613   0.597   0.117   0.088   0.128   0.056   0.001  11.151  31.322  36.042   0.398
048  1710176956.483   0.637   0.017   0.003   0.001 566.095   0.196   0.617   0.639   0.116   0.084   0.125   0.056   0.001  11.119  31.394  35.955   0.397
049  1710176957.135   0.633   0.018   0.003   0.002 567.317   0.193   0.696   0.609   0.118   0.089   0.128   0.057   0.001  11.030  31.297  35.939   0.395
050  1710176957.788   0.638   0.024   0.013   0.002 570.480   0.194   0.650   0.613   0.124   0.083   0.126   0.056   0.001  11.094  31.349  36.069   0.401
051  1710176958.444   0.634   0.017   0.003   0.001 567.719   0.195   0.686   0.591   0.117   0.083   0.132   0.057   0.001  11.028  31.395  35.928   0.394
052  1710176959.097   0.643   0.017   0.003   0.002 566.287   0.201   0.640   0.597   0.118   0.084   0.126   0.057   0.001  10.899  31.312  35.987   0.405
053  1710176959.749   0.637   0.017   0.003   0.002 567.780   0.196   0.647   0.611   0.118   0.084   0.131   0.057   0.002  10.977  31.435  35.997   0.395
054  1710176960.402   0.642   0.018   0.003   0.002 566.576   0.196   0.659   0.598   0.118   0.083   0.125   0.063   0.001  10.988  31.387  35.980   0.394
055  1710176961.055   0.627   0.017   0.003   0.002 566.366   0.194   0.659   0.613   0.118   0.084   0.135   0.056   0.001  10.914  31.310  36.169   0.396
056  1710176961.707   0.636   0.019   0.003   0.001 569.009   0.503   0.641   0.903   0.118   0.091   0.156   0.135   0.001  11.073  31.615  36.288   0.661
057  1710176962.366   1.732   0.019   0.002   0.002 570.110   0.196   0.658   0.647   0.118   0.083   0.134   0.057   0.001  11.127  35.682  35.929   0.401
058  1710176963.027   0.644   0.018   0.003   0.002 567.595   0.194   0.651   0.635   0.117   0.083   0.127   0.056   0.001  11.326  31.369  36.038   0.396
059  1710176963.681   0.628   0.019   0.002   0.002 566.851   0.194   0.634   0.625   0.118   0.084   0.128   0.055   0.001  11.123  31.468  35.948   0.393
060  1710176964.333   0.642   0.017   0.003   0.002 566.545   0.205   0.656   0.594   0.117   0.083   0.129   0.055   0.001  11.380  31.452  36.488   0.396
061  1710176964.987   0.630   0.018   0.003   0.002 567.141   0.231   0.631   0.615   0.117   0.084   0.125   0.055   0.001  11.449  31.284  35.898   0.393
062  1710176965.640   0.635   0.017   0.003   0.001 566.420   0.194   0.602   0.623   0.118   0.083   0.121   0.057   0.006  11.244  31.312  36.203   0.401
063  1710176966.292   0.636   0.018   0.003   0.001 566.424   0.196   0.646   0.604   0.119   0.084   0.127   0.056   0.001  10.810  31.245  36.966   0.411
064  1710176966.945   0.630   0.024   0.013   0.002 566.426   0.194   0.675   0.612   0.118   0.094   0.128   0.057   0.001  11.130  31.371  36.999   0.401
065  1710176967.598   0.634   0.018   0.003   0.002 569.700   0.204   0.633   0.603   0.117   0.083   0.125   0.056   0.002  11.036  31.356  36.108   0.394
066  1710176968.253   0.640   0.018   0.003   0.002 567.129   0.195   0.607   0.688   0.124   0.084   0.124   0.056   0.001  11.009  31.371  36.027   0.401
067  1710176968.906   0.633   0.018   0.003   0.002 565.612   0.203   0.671   0.599   0.116   0.083   0.125   0.056   0.001  10.705  31.379  36.182   0.396
068  1710176969.557   0.642   0.017   0.003   0.001 568.389   0.201   0.625   0.654   0.119   0.084   0.131   0.057   0.001  11.058  31.396  36.111   0.395
069  1710176970.212   0.628   0.018   0.002   0.002 566.199   0.195   0.646   0.595   0.117   0.083   0.126   0.061   0.001  10.833  31.327  36.125   0.395
070  1710176970.863   0.642   0.017   0.003   0.002 566.881   0.197   0.664   0.591   0.117   0.090   0.124   0.057   0.001  10.981  31.328  35.953   0.392
071  1710176971.516   0.628   0.017   0.003   0.002 566.241   0.194   0.659   0.633   0.118   0.084   0.123   0.062   0.001  10.926  31.365  36.098   0.394
072  1710176972.167   0.639   0.017   0.003   0.002 569.547   0.356   0.654   0.613   0.118   0.084   0.131   0.141   0.001  11.005  31.306  35.999   0.685
073  1710176972.826   1.742   0.017   0.003   0.001 568.023   0.194   0.629   0.602   0.117   0.084   0.123   0.056   0.002  10.927  31.313  35.976   0.394
074  1710176973.480   0.641   0.017   0.003   0.001 569.769   0.195   0.636   0.678   0.117   0.083   0.124   0.061   0.001  11.282  31.428  35.903   0.399
075  1710176974.136   0.636   0.017   0.003   0.002 566.796   0.194   0.653   0.627   0.117   0.084   0.124   0.073   0.002  10.784  31.387  36.141   0.393
076  1710176974.788   0.641   0.018   0.003   0.002 566.806   0.196   0.656   0.595   0.118   0.083   0.131   0.056   0.001  11.171  31.349  35.968   0.396
077  1710176975.441   0.630   0.023   0.003   0.002 567.456   0.194   0.654   0.627   0.125   0.085   0.126   0.056   0.001  11.124  31.371  36.198   0.397
078  1710176976.094   0.643   0.017   0.003   0.002 566.938   0.195   0.613   0.596   0.117   0.083   0.124   0.056   0.001  10.970  31.337  36.105   0.393
079  1710176976.747   0.631   0.017   0.003   0.002 568.831   0.194   0.609   0.648   0.118   0.083   0.125   0.055   0.001  11.077  31.336  35.977   0.397
080  1710176977.401   0.638   0.018   0.003   0.001 564.980   0.195   0.685   0.601   0.117   0.084   0.122   0.063   0.001  10.931  31.312  36.033   0.396
081  1710176978.052   0.630   0.018   0.003   0.002 566.748   0.194   0.676   0.622   0.118   0.083   0.125   0.057   0.002  11.122  31.409  36.197   0.394
082  1710176978.704   0.641   0.026   0.012   0.002 566.579   0.197   0.665   0.650   0.118   0.083   0.125   0.061   0.001  11.342  31.363  40.708   0.396
083  1710176979.362   0.630   0.017   0.003   0.002 567.053   0.203   0.644   0.600   0.118   0.083   0.126   0.056   0.001  10.994  31.350  36.342   0.396
084  1710176980.014   0.648   0.018   0.003   0.001 567.508   0.201   0.628   0.676   0.116   0.083   0.126   0.055   0.001  11.326  31.353  35.999   0.395
085  1710176980.668   0.633   0.016   0.003   0.002 566.638   0.194   0.640   0.597   0.118   0.083   0.127   0.054   0.001  11.118  31.345  35.914   0.400
086  1710176981.320   0.646   0.017   0.003   0.002 566.983   0.195   0.702   0.590   0.121   0.087   0.124   0.056   0.001  11.220  31.319  35.979   0.398
087  1710176981.973   0.634   0.017   0.003   0.001 567.545   0.195   0.602   0.595   0.118   0.084   0.124   0.057   0.001  11.417  31.365  36.243   0.405
088  1710176982.626   0.640   0.017   0.003   0.002 565.968   0.195   0.637   0.599   0.119   0.083   0.123   0.056   0.001  10.989  31.346  35.936   0.401
089  1710176983.277   0.628   0.015   0.003   0.002 566.326   0.196   0.645   0.602   0.118   0.083   0.126   0.057   0.001  10.849  31.537  36.117   0.393
090  1710176983.929   0.637   0.016   0.003   0.002 569.852   0.194   0.683   0.611   0.117   0.084   0.126   0.055   0.001  10.798  31.367  35.928   0.401
091  1710176984.584   0.631   0.017   0.002   0.001 571.955   0.352   0.689   0.596   0.117   0.084   0.131   0.139   0.001  11.187  31.335  36.047   0.682
092  1710176985.244   1.727   0.016   0.004   0.001 566.733   0.194   0.612   0.616   0.117   0.090   0.124   0.055   0.001  10.952  31.308  36.219   0.400
093  1710176985.898   0.628   0.018   0.004   0.002 566.060   0.200   0.602   0.627   0.117   0.083   0.125   0.056   0.002  11.088  32.352  36.037   0.394
094  1710176986.550   0.635   0.017   0.003   0.002 566.814   0.195   0.640   0.622   0.117   0.083   0.123   0.056   0.001  11.324  31.351  36.345   0.393
095  1710176987.202   0.629   0.017   0.003   0.002 566.586   0.194   0.652   0.672   0.117   0.083   0.131   0.057   0.001  10.958  31.435  36.180   0.401
096  1710176987.854   0.644   0.017   0.003   0.002 566.027   0.194   0.669   0.596   0.117   0.083   0.126   0.056   0.001  10.909  31.394  36.098   0.399
097  1710176988.506   0.636   0.017   0.003   0.001 566.741   0.192   0.636   0.651   0.118   0.084   0.125   0.056   0.002  11.258  31.340  35.949   0.392
098  1710176989.158   0.640   0.017   0.003   0.002 569.880   0.201   0.642   0.664   0.117   0.083   0.123   0.055   0.001  10.825  31.324  35.999   0.404
099  1710176989.813   0.628   0.016   0.003   0.001 566.983   0.202   0.645   0.596   0.118   0.083   0.124   0.056   0.001  11.322  31.347  36.264   0.399
evt  t00(sec)    ms:  t01     t02     t03     t04     t05     t06     t07     t08     t09     t10     t11     t12     t13     t14     t15     t16     t17
job #1 median:        0.637   0.018   0.003   0.002 567.135   0.195   0.646   0.611   0.118   0.083   0.126   0.056   0.001  11.075  31.371  36.003   0.396 other 
other jobs
job #2 median:        0.628   0.017   0.003   0.001 566.815   0.194   0.638   0.639   0.117   0.084   0.128   0.055   0.001  11.071  31.411  36.020   0.391
job #3 median:        0.628   0.016   0.003   0.001 567.021   0.194   0.689   0.601   0.118   0.084   0.125   0.055   0.001  11.060  31.398  35.948   0.395
job #4 median:        0.638   0.016   0.003   0.002 567.018   0.195   0.627   0.629   0.117   0.083   0.127   0.057   0.001  11.080  31.404  35.974   0.396
job #5 median:        0.805   0.014   0.003   0.001 567.475   0.212   0.654   0.624   0.120   0.085   0.125   0.057   0.001  11.093  31.389  35.989   0.400

Summary



w/o loops over panelswith loops over panels
dtmeaningarray size in  (512,1024)msecarray size in  (512,1024)mseccomment
01get det.raw(evt)80.66480.638
02get detector name from source
0.015
0.016
03access cache object for detname
0.003
0.003
04get peds, gfac, mask, out, cmps3x80.0023x80.002
05

single panel begin processing

begin processing entire array0.001begin processing last panel567meaningless
06make gain range indices, gr0, 1, 281.40810.195
07np.select for gain factor85.3410.627
08np.select for gain peds+offset85.0010.629
09apply mask for data bits, arr & MSK81.7310.117
10subtract pedestals81.1910.083
11massaging common mode parameters
0.272
0.127
12apply pixel mask for gr080.67410.057
13begin loop over panels for CMCtime to work with last panel549time to work with current panel0.001meaningless
14CMC in banks: (512/2,1024/16) = (256,64)111.2111.1CMC always loop over panels
15CMC in rows per bank: 1024/16 = 64 pixels131.3131.4
16CMC in cols per bank: 512/2 = 256 pixels135.9136.0
17Apply gain correction and mask82.8710.40

Total time per event85768582
  • where CMC stands for common mode correction

References