June 6, 2017

Chuck:

  • summer intern (utsab) working on sz absolute error compression
  • working on photon conversion: with zwart and ruslan using det.photons()
  • working on manifold embedding with hao-yuan for 2016 dataset (works for 2015 dataset)
  • triggering options are time-of-flight and ROI/threshold on image (drifting background: need running average)
  • hao-yuan looking at neural-nets for SPI hit-finding

clemens:

  • working with cpo on data format inside DRP nodes
  • can distribute at 3MHz on 4 core laptop

cpo

  • looked at EPICS pvData with Murali
  • ric and mark working on trigger and event distribution

silke

  • focusing on lcls-1

May 23, 2017

mark

mikhail

chris

  • went to hutches and played around with DAQ interface to enable event veto
  • worked on quick-and-dirty background-subtraction/thresholding algorithm:  numba: 2ms, c++: 6ms (not understood why c++ slower). 

sioan

silke

chuck

clemens

May 16, 2017

mark

  • getting open cluster working in lab2 drp node

mikhail

chris

  • lab2 pgp loopback is running
  • 0.5 Mpixel epix calibration is 30ms and peak-finding is about 60ms (although likely our algorithm can be sped up).  doesn't bode well for 4MP epixM at 10kHz in 2020.  looking into "quick and dirty" detector triggering algorithm:  simple background subtraction and thresholding 

sioan

  • led's are counting on FPGA eval board

chuck

  • working on SZ absolute error of +-30 doesn't seem to affect indexing

silke

May 9, 2017

clemens

  • pgp in lab2

mark

  • thinking about reusing astronomical package

mikhail

chris

  • setting up test stand
  • still understanding trigger vs. filter setting

silke

  • distracted by turning things on

sioan

  • moving from devel board to pgp card
  • no progress on sxrk4816

chuck

  • sfx: trying sz with 60 ADU
  • spi: users like veto, binning, but not general lossy compression (e.g. sz)
  • spi: data will be more sparse because of lower fluence (not true for sfx)

May 2, 2017

clemens:

  • working on other stuff. need to pick out new project.
  • handed off drp event distribution to mark

mark:

  • working on drp event distribution

mikhail:

  • working on other stuff (fiber diffraction)

sioan

  • able to program image for xilinx eval board!
  • still working on sxrk4816 SZ compression
  • identified turner expt in oct for data reduction

silke

  • will do determination of z distance of detector
  • will see if beam centers work for tim analyses
  • working on time tool calibration issues

chris

  • understanding DAQ L3T code/control

Apr 25, 2017

sioan:

  • has fpga hardware
  • starting to use Herbst makefile
  • sxrk4816 is on back burner (using absolute sz errors)
  • continue to identify experiments where we can reduce

mikhail:

  • working on fiber diffraction

yoon:

  • finished indexing the 1% error (191k patterns) (vs 200K without the error).  but might be missing a couple of runs which could explain difference.
  • redo with absolute errors.
  • wrapped up SPI wavelets.  binning is better than wavelets.

chris:

  • want to look at DAQ code for triggering

clemens:

  • working on DRP event distribution

Apr 4, 2017

sioan:

  • vivado hls:  C-style programming done
  • matlab is next

silke:

  • filtering with ipimb
  • mike kozina expt analysis (hoffman expt) to test filtering

chuck:

  • indexing selenium, in progress
  • jungfrau: 8kHz @4MegaPixel now, with 16 images depth
  • epix: 25kHz in 2019, @2MegaPixel
  • vfccd: 5kHz @4MegaPixel

mikhail:

  • working with meng

chris:

  • sz
  • save for a day

clemens:

  • data in and out of pgp

Mar 28, 2017

sioan:

  • still working on compiling hello-world
  • still working on sxrk4816 with clemens

silke:

  • cleaning up ring analysis
  • get a t0 difference-image and talk with Tim
  • think about ipimb filtering

chuck:

  • student (zhen) working on 1% SZ error on selenium sad
  • hao-yuan working on wavelet for SPI, feels messy (throws away photons) leaning towards binning

clemens:

  • working on distributing PGP events

cpo:

  • explore the idea of keeping the data for a day

Mar 14, 2017

cpo:

  • zhenglin results
  • upcoming meetings with users

sioan:

  • working sxrk4816 analysis
  • continuing to work on FPGAs

mikhail:

  • working on cxif5315 analysis
  • ask meng if hit-finding will work for her experiment for DRP

clemens:

  • added vectorized KNL code
  • added silke's pyfai GPU measurements
  • working with Dan/Jack on handing out 
  • how does NVME buffering work

silke:

  • beam centering: hough, ransac, scipy optimize 1-ring fitting
  • canny uses soble filter
  • looked at skbeam.  canny works better.
  • hough transform took optimizing

Mar 7, 2017

chuck:

  • playing around with SZ.  difficult because doesn't integrate into python.
  • simulated SZ by adding 1% error
  • sees common mode shift.  surprising, not understood
  • indexing rate is 98% similar.  looks promising

mikhail:

  • fiber diffraction

sioan:

  • committed spatial example to drp eval
  • looking at effect of SZ on georgi's expt
  • maybe work with clemens on sxrk4816
  • mtg with Ryan Herbst on Mar 8

chris:

  • zhenglin doing the legion peak-finder
  • cuda peak-finding looks worse than cpu
  • zhenglin will send out updated results

silke:

  • finished pyfai
  • working on center-finder
    • some people want to run center-finder multiple times during the run
    • looking at the hough transform in skimage (needs a boolean)
    • hough transform is SLOW.  working on it.
  • difficulty with conda and interactive plotting

clemens:

  • integrating silke's pyfai numbers from gpu onto his plots
  • will work on legion
  • next project:  work on the infrastructure for handing out events to different cores

Feb 28, 2017

mikhail:

  • looked at skbeam centering algorithm
  • sz compression

silke:

  • try SZ compression on some XPP/XCS datasets

sioan:

  • try SZ compression on some SXR/AMO dataset (works trivially with georgi's dataset)
  • spatial FPGA code working

clemens:

  • angular integrations: background is not symmetric (scattering from masks etc).  take difference of t0 (no signal) and later data (with signal) and that is symmetric and allows determination of beam center.  beam centers changes every half-hour so calibrations would have to be quick.
  • have results for CPU/KNL
  • found benchmark of EPICS common-mode correction, found performance problem in ndarray.
  • looked at intel vtune

chuck:

  • wavelet stuff takes 3ms on 250x250 image with pywt
  • visually physics results look OK

chris:

  • working with legion people on gpu-based two-threshold lag

Feb 21, 2017

sioan:

  • working on spatial.  good progress

clemens:

  • found slowdown for python bin count:  memory copy due to bad types
  • went through nersc presentation slides
  • need to use the fast local ram on knl
  • to do: how much does it cost to get 10GB/s through a node?
  • working with timbvd on beam-position centering
  • why is it hard to do in angular integrations in real-time?  detector corrections

mikhail:

  • working on sz from argonne
  • difficulty running examples, but fixed
  • only runs on floats
  • timing measurements for sz
  • automatic centering algorithm in skbeam/xicam/silke's huff algorithm

chuck:

  • away at LBL xtallography workshop:  pessimistic about drp
    • unit-cell not known
    • bad pixels, which change over time (good enough, but room for improvement in our dark runs)
      • compare bad-pixel maps from super-users to dark-run results
    • geometry
  • python scaling problem work
  • students look at pywavelets:  zero-pads for performance reasons

Feb 14, 2017

Chuck:

  • Tried SPI wavelet compression: 4x (on top of a 4x binned image)
  • quantifying the error at goal: 3Angstrom resolution (currently 9nm)

Mikhail:

  • looking at igor/matt compression
  • much faster than gzip, but limit is 2x compression
  • igor used multi-threading, matt did not
  • to do: enter igor stuff in spreadsheet, work on argonne package

silke:

  • work on pyfai
  • ran on  gpu102
  • compared with henrik bincount method
  • csr ocl is 4x as fast 1x henrik code, their numpy version is very slow (30x slower than henrik's)
  • turn it into a metric (standardize on 1024x1024 single-precision "bincount" method, if pyfai will do that)

clemens:

  • benchmarking phi
  • python is 8x worse than C
  • to do: test at SLAC and test with matrix multiply
  • to do: run all corrections and see if we can get 10GB/s

sioan:

  • running spatial builds

Feb 7, 2017

sioan:
possible users to contact:

  • nora berrah
  • dan higley
  • mankowsky
  • urs staub (elsa abreu)
  • marcus kubin (slow andor)
  • emmanuel jal
  • sam vinko
  • christoph bostedt

to do:

  • finishing populating list
  • will work on algorithms or data transfer
  • come up with examples where we need shot-by-shot position measurements with a reticle

silke:
cases where people rerun analysis:

  • some people reran roi's 3 months after
  • some people had a crappy detector and had to rerun analysis

possible users to contact:

  • timbvd
  • mike kozina
  • reis / mariano
  • henrik
  • ulvestad
  • marco

to do: will work on algorithms or data transfer

mikhail:

  • szip (proprietary)
  • lzf+shuffle (1.5 for calibrated, 1.7 for raw)
  • shuffle (5%-20%)
  • best: gzip with shuffle (2.2 for calibrated)
  • wait on SZ compressor results
  • look at igor algorithm
  • picking a feature-extraction

clemens:

  • comparing python/C++: still working on it
  • zmq/mpi/gasnet
  • gasnet: 3 year old python bindings
  • setup mtg with elliott/wonchan?
  • talk with DAQ about DRP re-configuration

Jan 27, 2017

mikhail:

  • henrik algorithm
  • filipe maia algorithm
  • running on gpus/knl
  • evaluate compression package from argonne that amedeo will send out

clemens:

  • why only 10GB/s with bincount?
  • why c++ 10x faster?
  • scaling plot with cores

silke:

  • understand required info for each expt (talk to timbvd about real-time angular integration difficulties)

sioan:

  • populate amo/sxr 2016 table like Silke

cpo:

  • evaluate pyfai
  • work on gpu peakfinding with legion with zhenglin
  • purchase knl/gpu/nvme boxes
  • No labels