Cookbook for setting up dark/common mode correction
detailed information can be found at:
CsPad calibration in translator
generate dark
psana -c cspaddark.cfg xtcfile
psana config file
setup for translator
- generate directories
mkdir /reg/d/psdm/cxi/cxi49812/calib/CsPad::CalibV1/CxiSc1.0:Cspad2x2.0/common_mode
mkdir /reg/d/psdm/cxi/cxi49812/calib/CsPad::CalibV1/CxiSc1.0:Cspad2x2.0/pedestals
mkdir /reg/d/psdm/cxi/cxi49812/calib/CsPad::CalibV1/CxiSc1.0:Cspad2x2.0/filter - move dark
cp mini_r212.dat /reg/d/psdm/cxi/cxi49812/calib/CsPad::CalibV1/CxiSc1.0:Cspad2x2.0/pedestals/0-10.data - set common mode parameters
0-end.data should contain something like: 1 50 10
that stands for 1 (correction actice) 50 (max common mode value) 10 (allowed sigma for histogram fit in common mode calculation) - set filter
0-end.data data could look like one of these lines:
1 100 1000 (100 strong spots required)
1 500 100 (500 relatively weak spots required)
1 100 10 (100 weak pixels required)
1 10 10 (takes pretty much anything - for tests only)