ana-1.2.9
links: py27 py3 overall build
Add redis-py to the environment.
David updated tensorflow to 1.1.0
psana is now built against QT 4.8.7 instead of 4.8.5
ana-1.2.8
links: py27 py3 overall build
Upgrade LogBookClient to the latest release (includes a port of the runTables client).
Various packages for DM.
psana is now built against QT 4.8.7 instead of 4.8.5
ana-1.2.7
links: py27 py3 overall build
add pscache
In reports above - automation downgraded opencv from 3.x --> 2.4 and upgraded pillow: 3.4.2 --> 4.1.0. By hand reversed this, full details: anarel-manage issue #40
conda-build 2.1.9
4/11/17
ana-1.2.6
links: py27 py3 overall build
use pytables instead of tables, two new psana packages.
ana-1.2.5
links: py27 py3 overall build
see links for minor changes, new GPU packages, new versions.
conda-build update 3/28/17
updated conda-build from 2.1.6 -> 2.1.8
this affects all conda environments, conda-build is a global tool
ana-1.2.4
links: py27 py3 overall build
update to allow development of ndarray from test releases
since report: added kafka-python to rhel7 environments
ana-1.2.3
links: py27 py3 overall build
official switch to using github/lcls-psana for source code
any test releases should be redone, replace all psdm svn checkouts with git
openmpi downgraded to 1.10.6 do to problem with 2.0.2 and our batch system
jinjai pinned to 2.8.1 for DDL
ndarray updated to 1.1.8, note new deprecated warning
ana-1.2.2 - special - git
links: py27 py3 overall build
This environment is built against the lcls-psana github.
We may not make it ana-current, for development.
since build report above: downgraded jinja -> 2.8.1 for DDL
conda update 3/9/2017
conda 4.3.8 -> 4.3.14
conda-build 2.1.2 -> 2.1.6
this affects all conda environments - conda is a global tool.
ana-1.2.1
links: py27 py3 overall build
- pyimgalgos: for now see ana-0.19.27
- CalibManager: some re-factoring
- external packages
- xarray - breaking changes, for instance, import xray fails, now xarray
- tensorflow - 1.0.0 - breaking changes
- numerous other package updates - see py27 link above
ana-1.2.0
links: py27 py3 overall build
- added git and cmake to conda environments, newer version than system, warrants 1.1.x -> 1.2.x
- since build report above
- added gunicorn, lxml, cssselect, APScheduler to rhel7 envs
- added notebook to rhel7 py3 env
- added hexanode-proxy 0.0.1 (from our local channels)
- ana-1.2.0-gpu environment looks for cuda-7.5, will only work on psanagpu102, supports installed tensorflow 0.10.0
ana-1.1.0
links: py27 py3 overall build
- openmpi from 1.10x -> 2.0.x warrants changing middle version number
- new pdsdata with LabDet sourrce
- psocake now runs under conda
- many external package changes, switched many from conda-forge to defaults
ana-1.0.8
links: py27 py3 overall build
- jungfrau detector. Not yet in Detector xface, use old type xface.
- add biopython to environments
ana-1.0.7
links: py27 py3 overall build
ana-1.0.6
links: py27 py3 overall build