Manual: Calibration Management Tool
Tentative GUI for CalibManager
CalibManager is assumed to be a common GU interface for all varieties of calibration procedures and file management.
- Most part of the interface will be integrated in a single window.
- Tab bar will switch between different procedures.
- Windows, which need to be seen simultaneously, will be open in separately;
- Logger
- Graphics
- File browser
- Notification pop-up boxes
- Directory and file selection boxes
- Help window
Configuration GUI
Pedestals calibration GUI
Standard file selection window
Logger GUI
File browser GUI
Image browser
Help window
2013-07-29 New Calibration-centric style of GUI
- Calibration management tool should do many things around maintenance/check of the structure of calibration directories/files with correct names. Igor suggested to try the interface where the calibration structure tree is a central part of the GUI. Left panel presents the known names of the calibration tree. Right panel shows the status and other details.
- Default calibration directory is selected by the instrument and experiment names in the top panel.
- Non-standard calibration directory name can be also selected using Browse button.
- Currently available directories/files can be selected and their content is seen in the Status panel.
- The sources of calibration files may be different and can be selected in tab-bar controlled panels.
Calibration GUI for CSPAD
Calibration GUI for CSPAD2x2
Amedeo's layout of the calibration GUI
2013-08-07 GUI for dark runs
Dark runs processing GUI
- at start from scratch
- with all defined parameters
- with more options
- File browser
- Image browser
- GUI for configuration parameters
2013-08-14 GUI for dark runs
Major changes:
- The Instrument/Experiment/Directory/Detector (IEDD) bar is moved to the common top.
- Activity tab bar and its window widget is in the center of the main GUI.
- Dark GUI is changed:
- State panel shows content of the calibration directories, when the IEDD info is provided.
- Run bar is replaced for the list of run-items panel with the same features.
- Expand/shrink button shows/hides additional information for run-items in the list.
2013-09-16 Project Status
GUI for dark runs
- Change color scheme:
- grey - nominal state of buttons,
- green - hint for the next button to proceed,
- red - Stop or Quit GUI
- Add option to Deploy or see deploy command lines
- Add plots for CSPAD array and CPAD2x2
- Add button to start mask-editor
GUI for mask editor
2013-11-20 Project Status
New features are implemented in calibman
for dark run calibration:
- different type of detectors can be calibrated simultaneously. Desired types can be selected from the list of currently implemented: CSPAD, CSPAD2x2, Princeton, pnCCD, Tm6740, Opal2000, Opal4000, Acqiris.
- expert level interface is simplified, now it contains buttons only, which show info in the log window (bottom part).
- list of runs can be selected by the run type ("dark" or "all") for detectors ("any", "selected any", "selected all").
- initial list of runs is generated using info about runs and detectors from DB. The list of detectors in DB does not coincide with what is coming from xtc file scan (some of detectors are used for control and their data is not saved in xtc...). When the scan results is available, the information about detectors is taken from this scan. This changes the list of shown runs depending on selection...
2014-01-10 Project Status
To-do
- GUIDark
select commands for specific detectors from the list before deployment
add record to history file
save position and size of the main windows at exit and restore at next launch
auto-create work directory if it is missing
plot difference between new and existing dark file
plot image from any file
update status of buttons at the end of batch job
evaluate and deploy (if check-box is on) the hot pixel mask
- In run item update stop button when batch is done - for some reason it does not work...
- GUIFileManager
deployment (copy in a right place) of single file from other place with changing run validity range
History file content
Example of the history file:
/reg/d/psdm/MEC/meca1113/calib/CsPad::CalibV1/MecTargetChamber.0:Cspad.0/pedestals/HISTORY
file:528-end.data copy_of:clb-meca1113-r0528-peds-ave-MecTargetChamber.0:Cspad.0.txt exp:meca1113 run:0528 user:dubrovin host:psexport01 cptime:2013-12-03T18:46:54 zone:PST file:45-end.data copy_of:clb-meca1113-r0045-peds-ave-MecTargetChamber.0:Cspad.0.txt exp:meca1113 run:0045 user:dubrovin host:psexport01 cptime:2013-12-04T10:18:26 zone:PST file:79-end.data copy_of:clb-meca1113-r0079-peds-ave-MecTargetChamber.0:Cspad.0.txt exp:meca1113 run:0079 user:dubrovin host:psexport01 cptime:2013-12-04T10:19:48 zone:PST file:219-end.data copy_of:clb-meca1113-r0219-peds-ave-MecTargetChamber.0:Cspad.0.txt exp:meca1113 run:0219 user:dubrovin host:psexport01 cptime:2013-12-04T10:20:32 zone:PST file:220-end.data copy_of:clb-meca1113-r0220-peds-ave-MecTargetChamber.0:Cspad.0.txt exp:meca1113 run:0220 user:dubrovin host:psexport01 cptime:2013-12-04T10:21:25 zone:PST file:221-end.data copy_of:clb-meca1113-r0221-peds-ave-MecTargetChamber.0:Cspad.0.txt exp:meca1113 run:0221 user:dubrovin host:psexport01 cptime:2013-12-04T10:22:10 zone:PST file:222-end.data copy_of:clb-meca1113-r0222-peds-ave-MecTargetChamber.0:Cspad.0.txt exp:meca1113 run:0222 user:dubrovin host:psexport01 cptime:2013-12-04T10:22:58 zone:PST file:373-end.data copy_of:clb-meca1113-r0373-peds-ave-MecTargetChamber.0:Cspad.0.txt exp:meca1113 run:0373 user:dubrovin host:psexport01 cptime:2013-12-04T10:24:48 zone:PST file:659-end.data copy_of:clb-meca1113-r0659-peds-ave-MecTargetChamber.0:Cspad.0.txt exp:meca1113 run:0659 user:dubrovin host:psexport01 cptime:2013-12-04T10:25:36 zone:PST
2014-04-04 Project Status
New release ana-0.10.15 - has CalibManager V00-00-28 with auto-update of the run list with new xtc files,
but it also has new pyqt which broke interaction with matplotlib graphics.
CalibManager V00-00-29 - has a patch which correctly defines matplotlib backend in the app/calibman.
To-do
in GUIInsExpDirDet.py update the list of runs for Dark tab only (because it is slow)
in GlobalUtils.msg_and_status_of_lsf(...) add count fro number of nodes, add command and status line in output
in updated list of runs, check if the last xtc file (is available in RegDB) is not on disk yet, then do not allow to push on button go
Silke asked to split log scales in the plot for log X and log Y
complete GUIMetrology for operations with CSPADV1
2014-04-20 Project Status
ana-0.10.15 with CalibManager V00-00-38 - calibrun is ready for exploitation
To-do
Get rid of AFS token at batch job submission
For info purpose use package revision no. in stead of last tag in the
psvn tags<pkg-name>
command
2014-04-25 Project Status
ana-0.10.16 has CalibManager V00-00-39
To-do
Implement Delete for Group file manager, fix Instrument selection drop-down list
In "calibrun" add command line in log file
In GUIConfigPars add queues status using command:
bqueues psanacsq psnehq psfehq
Change decision algorithm for submission of jobs in batch, use number of "ok" and "closed" nodes
- In "calibman" add option to run psana interactively
- Run range viewer
2014-07-02 Project Status
ana-0.11.9 has CalibManager V00-00-56
For variable shape Camera-type detectors (Tm6740, Opal1000-Opal8000, OrcaFl40) save calibration files with metadata
Add in configuration parameters GUI field for number of events to scan; default 10 sometimes is too small to discover data from PV with wrong timing, which come later.
Add protection against deployment of files in non-"calib" directory
References
- Manual: Calibration Management Tool