This example can be found in /sdf/group/lcls/ds/ana/tutorials/psana1_examples/mpiGatherv.py.  It uses the more performant, but more difficult to use, "Gatherv" array implementation (vs. the lowercase "gather" which uses python objects shown here).  There is also "Gather" method which more easily gathers arrays from all ranks that are of the same size.

from psana import *
import numpy as np
from mpi4py import MPI
comm = MPI.COMM_WORLD
rank = comm.Get_rank()
size = comm.Get_size()
ds = DataSource("exp=xpptut15:run=54:smd")
det = Detector('cspad',ds.env())
intensities = []   # use a list instead of array because faster to append
for nevent,evt in enumerate(ds.events()):
    if nevent==5: break
    if nevent%size!=rank: continue
    intensities.append(det.raw(evt).sum())

# real Gatherv logic starts here
lengths = np.array(comm.gather(len(intensities))) # get list of lengths
mysend = np.array(intensities)
print(f'Rank: {rank}, sending: {mysend}')
myrecv = None
if rank==0:
    myrecv = np.empty((sum(lengths)),mysend.dtype) # allocate receive buffer
comm.Gatherv(sendbuf=mysend, recvbuf=[myrecv, lengths])
if rank==0:
    start = 0
    # look in the receive buffer for the contribution from each rank
    for r,mylen in enumerate(lengths):
        print (f'Rank 0 received {myrecv[start:start+mylen]} from rank {r}')
        start += mylen