Attendees: Rebecca, Alyssa,                     Shanjie, James, Alex,


Agenda:

  • MFX photon dump sizing
  • CXI KB mirror shielding
    • Note Status: DRAFT circulated
  • Burn through calculations
  • XRT collimators
  • Raytrace methodology

Discussion:

MFX photon dump sizing

    • With hard stops dump size is now, exit window @200um: 28cm radius !! assuming 1W at wall - realistic?
      • using window as part of the sizing factors means that this device needs to be interlocked
      • what is size at 100um?
    • estimated beam size at dump (from Danny)
      • calcs start at 6keV -why?
      • .6mm FWHM - 6keV
      • .4mm 10kev
      • .4mm 15kev
      • .3mm 20kev
      • how far can focal point move? IP +/-4"  (can be hard stopped)
      • worst case spot sizes?
    • Alyssa has performed first pass for dump sizing: MFX-HE_BeamdumpPrelimResults_Draft1.docx
    • Assumptions: KB locations IP ; sample is worst case reflector; mirrors are silicon, 3KeV+. Calculations will be run for various beam powers. Various wall burnthrough limits.
    • Focused spot at IP is 1um. how far back (+Z) can the KB focus?
      • what is the beam size (worst case) at the wall (after it diverges)?
    • sheetrock burnthrough (ca sulfate)...or should we put layer of something else?
      • aluminum?
      • steel? can we assume steel can take 10W?
      • optical laser burnthrough test?
    • Need to check material of 2nd mirror substrate - ruthenium (more reflective– ~10%-25% bigger dump)
    • Need to find out if there is a physical way to limit lower energy range (software interlocks have never been successfully implemented for this).
    • Assuming 100um diamond window. is thicker ok? (required transmission?)
      • if we have 200um - 20%transmission @5keV; still ok at higher energy
      • Alex will think about what they really need for experiments
    • Dump type - same as XPP??
    • DUMP depth? few inches?
  • CXI KB mirror shielding
    • Done! Circulated to Serge/Danny. 
  • Burn thru calculations
    • Yiping - Air burn through 1D results: 50+m @18keV
    • methodology and assumptions need to be vetted for solid material burnthrough calcs
  • XRT collimators
  • Collimator type and material
      • reuse XTES design? or TBD
  • Solid atten has thick Si
      • operable to 25kEv (w/Si+SSt) - hack in XRT
      • Diamond, Silicon, and Germanium planned for new Solid attenuator
  • Power Slits - change blade
      • BeO2 ceramic blades? TBD
      • 10x more absorbant than Si??
  • Scatter Slits
    • No change - just limit insertion range
  • Raytrace methodology
    • MIRROR RANGES - where do we look up? +/-X; +/- Theta; hardstops;
    • build tolerances into raytrace?
      • Shanjie will send an example
    • drawing method
    • spreadsheet data?
    • reference files
      • RP requirements says you need to consider tolerance but doesnt prescribe how we do that