Attendees: Abigail, Leinani, Elena, Eli, Patrick, Eliazar, Dennis, Brett, Leland, Maggie, Armin
Announcements:
- New Laser folks:
- Beam transport- Brett
- Armin out next Week
- MFX Eng - Dennis
- Mirror FDR Feb. 15? maybe end Feb?
Discussion:
- ATM configurations
- need to check with Joe if mutiport faces laser table/tile
- if we need to change from 20 deg to a different angle down the line it would be good to know before install period
- stalk needs to be removed to make changes
- MFX ATM is a refurbish item (mostly internals)
- what is scope of refurb?
- stem and prism mounts
- what is scope of refurb?
- KB Mirror
- Mirror FDR Feb. 15
- Integrating bypass for future passthrough- rad safety
- Matt Seaberg to review (he's out though)
- Opened rev for Instrument PRD - added 2 new requirements
- RP shielding
- Thermal Enclosure- coordinate with Laser team on space stayclears
- interfaces to RDS
- multiplexing - how does this affect mirror motions?
- Far hall configuration
- Pass-through concept → better suited in a different area
- Expected to make MFX compatible with floating endstations
- day-1? controls impact?
- laser table moved back
- move diagnostic stand 1 to hutch 4 → shielding, raised floor, controls impacts
- laser rack → relocate (controls impact)
- RDS
- Expected to incorporate accommodations for multiplexing
- mirror → should be handles by one motion axis
- controls?? → some analysis needed to determine controls impact
- collimators position XRT
- diagnostics before KB mirrors can accommodate the offsets
- does angular dispersion affect x-ray focus?
- Anchor plate adapters where possible - new BIO
- BCR for new scope next week??
- Pass-through concept → better suited in a different area
- Diagnostic Station 1 in H4
- preliminary vacuum analysis
- still require level 1 processing
- check mirror assumptions - pumping levels? outgassing?
- prelim pressure level at mirror chamber 7e-10torr (used to be 5e-10 - no formal requirement)
- adding apertures reduces to 6e-10
- shielding structure
- concepts under way
- requirements from RP - directing us to mirror shielding note
- need to translate into thicknesses for shielding
- preliminary vacuum analysis
- Common components
- vacuum chambers for PPMs etc is next large procurement
- Assembly Travelers
- revision for WFS - Divya/Maggie will edit
- we can apply these changes to other travelers too
- ATM configs - see notes above
- Exit window installation - tomorrow
- Multiplexing ramifications?
- XRT diagnostics/stopper
- Installation planning
- Assumptions:
- there will be some down time at the BEGINNING of the installation window → XRT
- second downtime later in the window? install XRT items
- Assumptions:
- Controls
- per new scope direction please estimate required controls design work
- multiplexing PMPS
- mezanine relocations?
- cable tray overflow
- per new scope direction please estimate required controls design work
- Multiplexing
- Update from Hasan and Frank 12/8
- raytrace (need to get files from Lance and Frank)- received 1/16
- will start evaluating collimator location soon
- Documents:
- Scope Agreement Document?
- Instrument PRD - R2 open; added 2 new requiremnts - out for sig before break?
- Detector PRD out for signature? check progress? Stuck at Hong, Debarger
Detector PRD vs delivery plan - noise and well depth- are figures ok? is 10000photons @ 8keV ok (well depth)? noise <75e- vs <100 e-xpp hole will be 5mm - we can reuse guidance tube design (same as epix 10k)mfx assumption was we needed slightly larger hole? needed for laser?@ 450 mm away from IP, 5mm is a bit close.
- Detector ICD - Dionisio doc
- Detectors IRD in progress - Alex to look at
- transfer to Leland
- LFAD details looking ok–some questions about cryolines?
- need SFAD info
- ICD-Lasers
- out for review - out for signature
- out for review - out for signature
- Laser ESD
- out for review
- Laser Off-mods layout
- HE Lasers retreat
- helpful for engineering
- LIC rotation?
- egress is along the wall
- ATM tile work
- LIC south side? (1'x1')
- Next milestone: MFX PDR? Combine with transport or no?
- April?
- Working on design for off mods tiles - Patrick doing a first pass this week
- Off mods breadboard stand models (under MEC drift tube)
- Can we shift beampipe stand (MEC and CXI) upstream?
- Set up meeting for tile layout workflow
- Drift stand on MEC - would be nice to move
- Laser out coupling–what do you need in the beamline?
- CXI has an in-vacuum design? (maybe talk to Leslie)
- Space utilization - Patrick talk to Eli
- optics locations draft?
- optics categorization
- ATM tiles? need a final design?
- ejection layout
- IP
- LIC
- Diagnostic stand interfaces (breadboards)
- should attach to diagnostic stand?? not mods?
- need mods to stand?
- mount to floor instead?
- Laser Transport?
- HE Lasers retreat
- Laser in coupling as designed should work as
- access on working site: https://slac.sharepoint.com/:w:/r/sites/lcls/lcls-2-he/wd/ICD/LCLS-II%20HE%20MFX%20Lasers%20ICD.docx?d=w73e52e9056f94e0cb9df481c8cd63f6d&csf=1&web=1&e=hJLtqF
- Rebecca reviewed - a few small comments
- drawing tree: (link)
- RDS- R2
- laser updates?
- update with Det power requirements
- CO2 updates
- temp requirement - refine based on laser results
- Equipment anchoring BIO review -complete
- stands - complete
- stopper - Jenna - complete
- Controls Coordination - meet up to discuss status
- CXI will host 16M detector power (one full size rack) but will it be close enough?
- penetration from CXI? existing cable route?
- back corner?
- Detectors - what about small detectors?? small 140k Epix HR/UHR
- OH Robot- yes, the robot will live on
- Robot OH rack...chiller lives up there, MPOD, server
- fiber infrastructure for 16M complete
- vacuum eplan complete and reviewed
- need new controllers in MFX (MKS 937s)
- motion eplan is complete - needs review
- common component connection
- CC FDR review
- FXT FDR last week - well done!
- XRT stand naming DONE
- Enclosures added to model
- Rack profile planning ongoing
- timing system?
- each hutch has an ATC crate
- data structure is different for HE - working with data and detectors team
- fast scope? or virtual?
- out of scope items - older vac equipment, cameras, and motors etc. : how is this tracked?
- estimate in progress
- DC power - running by power supply expert on our side
- Endstation scope add estimate: eplan dwg (cosilab) and estimate spreadsheet TBD
- CXI will host 16M detector power (one full size rack) but will it be close enough?
- Temperature monitoring
- Alex ordered more temperature loggers (10)
- will place at KB locations and around hutch
- Matt has old data - gave to Ariel
- Facilities
- Water Routing → change to general facilities topics
- RDS v2
- meet with Kingston to discuss options for CO2 cooling
- water routing work will be packaged with other facilities work and sent out for bid ~late summer
- RDS v2
- Water Routing → change to general facilities topics
- Detector Coord
- detector mover limits
- can move limit switches to get the stroke that we need
- use this info to determine max detector envelope for IRD.
- This Friday
- CO2 implementation
- scientist to decide on types, quantities, need for first light
- update PRDs?
- ICD and IRDs in progress
- interface details with detector mover
- detector mover limits
- Laser coordination
- temp requirement check - look at systems in place for more data
- Added - struts on granite stand
- Moved - the ion pump on diagn. std 2. next to ATM
- Model - updated coordinate systems; stayclears will be added to laser model soon
- ELi - will add stayclears for under table patch panels - need clearance requirements from Serge
- Patrick working on PRD details (cacls to check if we can meet requirements)
- ICD/PRD/Laser ESD still in progress
- Focus on PRD (working on CXI first)
- Patrick touch base with Alex?
- DxS-MFX transport line is still not finalized
- but it is the preference
- ATM config?
- up to 45 deg needed??? possible?
- difference btwn L2Si vers and HE vers?
- we are also ready to design laser out-coupling when laser team has details/requirements available
- Does the detector situation matter? beam tube size? this geometry is important...
- ideal hole diameter?
- what is needed?
- what is common ?
- document on confluence and eventually in PRD
- Resend Z location info to M. Greenberg - help him figure out divergence etc. which will let us know what hole diameter we need...
- thermal issues (see below)
- temp requirements?
- current requirement in RDS: +/-0.5 deg C
- better if laser outside of hutch?
- Installation
- CC RFI dates.
- KB should fit now into schedule
- Radiation safety
- Need radiation safety PRD from Shanjie
- raytace needs to incorporate gantry error
- fast sensor - need to run for MFX
- Elena to start this week. do requirements change for MFX in any way?
- passive shields - Abigail
- hands on 80/20 experience
- photon dump design kicks off this month
- photon dump size for MFX
- it wil be ~ 1mx 1m
- sensor selection - looking for a SME
- ESD in progress with mechanics specified
- photon dump size for MFX
- ray trace
- benchmark cases in progress
- format question for output
- walk through with RP during next meeting(s)
- KB
- Matt Seaberg - engineering note for KB hardstops
- hardstops; beam size on photon dump with Matt/Alyssa
- chiller check - rack space - under diag1
- check perimeter (for enclosure) - in model
- Status?
- focus range
- ESD documents?
- schedule -