L-10388 Tear-down Documentation
Schedule notes:
- Link to smartsheet schedule: https://app.smartsheet.com/sheets/j9j3gHvQMqCHWf8C4j25mMXHGfcpGwJf23mPX4M1?view=gantt
- Starting W 18 Sept 2024: MXI installation (after final shift of L-10425)
- Starting Th 27 Sept 2024:
- F-XRTS and B-XRTS removal (after photon MD time for spectrometer calibration)
- Installation commences.
- W 9 Oct 2024: Tentative SAXS checkout
- M 14 Oct 2024 - First shift.
Notes from 4 September 2024 meeting with Hae Ja and Peregrine:
Stay from L-10425 (Martin):
- SPL platform: all the stages
- XTCS spectrometer: stages and epix100a
- Displacement sensor: 1 VT-50
HJ: Remove: two XRTS by Sep.30. (Friday or Monday) – 2 sets of XYZ (PI stages), 2 epix100a because MD time on Sep. 26-27 night shift
By Oct. 1: New IN
- Imaging
- …MXI : right after Martin’s beamtime
- Small Hexapod
- Z stage (IMS)
- …Zyla and Optic-peters in-air
- OP (IMS)
- …MXI : right after Martin’s beamtime
- SAXS
- …jj slits : this week (Sep.4-), Chris, Thursday ,test controls
- Beckhoff-based motor control
- …ePix10k quad in-air on top of 500 mm stage, next to Zyla (Sep.23-Oct.2)
- …Remote desktop (2 laptops) – VNC viewer available? : Users part: 2 jj slits, flange on the top, 2 sets of in-air stage (OWIS)
- …jj slits : this week (Sep.4-), Chris, Thursday ,test controls
- FSI
- …small hexapod, 1 VT-50 stage in-vac: any time right after Martin’s beamtime
- …1 Alvium camera: NW side, any time right after Martin’s beamtime (Alvium 1800 U-1236m mono C-mount sony IMX304)
- TP
- …1 Alvium camera: between NE and E, any time right after Martin’s beamtime
- OAP imaging
- …2 Alvium cameras: between S and SE, any time right after Martin’s beamtime
Note - Removal of the B-XRTS and F-XRTS releases the following IMS channels:
B-XRTS | XYZ | IMS |
| MEC:TC1:MMS:{07,08,09} for Z,Y, X. | Yes | Yes | Using old XRTS stage pmgr: XUV Z/Y/X |
F-XRTS | Z | IMS | MEC:USR:MMS:22 | Using new XRTS stage PI motor: HD-26 to DSUB-15 pmgr: FWD XRTS X | |||
Y | IMS | MEC:TC1:MMS:23 | Using new XRTS stage PI motor: HD-26 to DSUB-15 pmgr: FWD XRTS Y | ||||
X | IMS | MEC:USR:MMS:25 | Using new XRTS stage PI motor: HD-26 to DSUB-15 pmgr: XUV X |
Motors
Remaining task list
Configuration Information
Device | Motor | Type | Hardware Address | EPICS PV | Cabled? | Running? | Comments |
---|---|---|---|---|---|---|---|
SPL M5 | Tip | Newport |
| MEC:PPL:MMN:09 | Yes | Yes | TRA12PPV6 |
Tilt | Newport |
| MEC:PPL:MMN:10 Note mismatch with physical card number. (should be MMN:11) | Yes | Yes | LTA2PPV6 | |
TSO | Focus | Newport |
| MEC:PPL:MMN:07 | Yes | Yes | LTAHLPPV6 |
Hor | Newport |
| MEC:PPL:MMN:08 | Yes | Yes | LTAPPV6 | |
Vert | Newport |
| MEC:PPL:MMN:11 Note mismatch with physical card number. (should be MMN:12) | Yes | Yes | UTS150PPV6 | |
SPL Ref Laser | IMS |
| MEC:USR:MMS:19 | Yes | Yes | pmgr: VT-50-100-L | |
Power Meter Stage | IMS |
| MEC:USR:MMS:21 | Yes | Yes | pmgr: VT-50-300 | |
Vacuum Iris | IMS |
| MEC:USR:MMS:20 | Yes | Yes | pmgr: Vacuum Iris | |
OAP | XYZ | IMS |
| MEC:TC1:MMS:{14,15,16} | Yes | Yes | pmgr: BWD XRTS X/Y/Z Position |
Filter | X | IMS |
| MEC:USR:MMS:23 | Yes | Yes | pmgr: VT-50-100 changed UREV from 1.0 to 0.5. |
Zyla | 500mm | Newport |
| MEC:PPL:MMN:24 | Yes | Yes | IMS500PP |
XTCS | Linear | Newport |
| MEC:PPL:MMS:17 | Yes | Yes | UTS150PPV6 |
RotatIonal | Newport |
| MEC:PPL:MMS:18 | Yes | Yes | URS50BPPV6 | |
Filter Wheel | IMS |
| MEC:TC1:MMS:22 | Yes | Yes | Rotation stage + limit switch | |
MXI | Hexapod | Small Hexapod |
| MEC:HEX:02 | Yes | Yes | HEX2 aka "Analyzer 1" |
Z Stage | IMS |
| MEC:USR:MMS:22 | Yes | Yes | pmgr: MXI-Z-Stage | |
FSI | Hexapod | Small Hexapod |
| MEC:HEX:03 | Yes | Yes | HEX1 ?? |
VT-50 Stage | IMS | MEC:USR:MMS:25 | pmgr: VT-50-TBD |
Detectors
Detector | DAQ alias | Connection | Cabled? | In DAQ? |
---|---|---|---|---|
Andor Zyla | Zyla_xray_east |
| Yes | Yes |
ePix100a | epix100a_3_xtcs |
| Yes | Yes |
epix10k-540k | Epix10kaQuad0 | in-air TBD | Yes | Yes |
TT Alvium | alvium_tt |
| Yes | Yes |
Spot Alvium | alvium_spot |
| Yes | Yes |
NF/FF Alvium | alvium_nf_ff |
| Yes | Yes |
Alvium | alvium_fsi | On NW side of target chamber
| Yes | Yes |
Alvium | alvium_tp | On NE side of target chamber
| Yes | Yes |
Alvium | alvium_oap1 | On SE side of target chamber
| Yes | Yes |
Alvium | alvium_oap2 | On SE side of target chamber