Note on Newport channels:

ControllerNotesIn-UsePlanned Use
mcn-mec-tch1 aka XPS1

IOC: ioc-mec-ppl-xps1

HOST: ioc-mec-opal1. RHEL5, Supermicro, R60 E30

01-04: UTS50PP (Questar 1 and 2)

05-06: LTA-HS (BED 1 and 2)


mcn-mec-tch2 aka XPS2

IOC: ioc-mec-ppl-xps2

HOST: ioc-mec-opal1. RHEL5, Supermicro, R60 E30

06 : IMS500PP (Zyla 500 mm)

01-03: VISAR XYZ

3 channels (VISAR)
mcn-mec-tch3 aka XP3

IOC: ioc-mec-ppl-xps3

HOST: ioc-mec-mot3 RHEL5, Supermicro, MEZZ R64A E34

01-03: East XYZ

04-06: West XYZ

6 channels (Lenses)
DeviceMotorTypeHardware AddressEPICS PVNotesCabled?Running?Comments
F-XRTS

XIMSdigi-mec-07:2111MEC:TC1:MMS:09

Spectrometer Screen; XRTS X

in-vac



MFORCE R64A E27

Flange D DB50

YIMSdigi-mec-07:2110MEC:TC1:MMS:08

Spectrometer Screen; XRTS Y

in-vac



MFORCE R64A E27

Flange D DB50

ZIMSdigi-mec-07:2109MEC:TC1:MMS:07

Spectrometer Screen; XRTS Z

in-vac



MFORCE R64A E27

Flange D DB50

B-XRTSX&YNewport

LTA → 2-axis horizontal motion

in-vac




ZNewport

UTS150PPV6 → vertical motion

in-vac




West Beam LensXYZNewport

X - MEC:PPL:MMN:20

Y - MEC:PPL:MMN:21

Z - MEC:PPL:MMN:22

MFA

in-vac

Yes


Yes

Channel assignments:

X - XPS3 #4 (*4)

Y - XPS3 #5 (*5)

Z - XPS3 #6 (*6)

East Beam LensXYZNewport

X - MEC:PPL:MMN:17

Y - MEC:PPL:MMN:18

Z - MEC:PPL:MMN:19

MFA

in-vac

YesYes

Channel assignments:

X - XPS3 #1 (*1)

Y - XPS3 #2 (*2)

Z - XPS3 #3 (*3)

VisarXYZNewport

X - MEC:PPL:MMN:09

Y - MEC:PPL:MMN:10

Z - MEC:PPL:MMN:11

MFAYesYes

XPS2

Channel assignments:

X - XPS2 #1 (*1)

Y - XPS2 #2 (*2)

Z - XPS2 #3 (*3)

TargetHexapod
digi-mec-03:2015IOC:MEC:HEX1in-vacYesYes

IOC: ioc-mec-hex1

HOST: ioc-mec-mot3. RHEL5 Supermicro, MEZZ R64A E34

PLS-85
moxa-mec-09:4005MEC:USR:MMS:17in-vacYesYes

IOC: ioc-mec-usrppl-ims

HOST: Ioc-mec-opal01. RHEL5, Supermicro, R60 E30

XYZ?


in-vac


Beam Block MotionTBDNewport

MFA

in-vac



L-10034 user supplied.
TBDNewport

MFA

in-vac



L-10034 user supplied.
Misc.LinearNewportXPS 2 Channel 6MEC:PPL:MMN:14500 mm, in-air

Autoconfig; reboot.
Zyla turretDumbmoxa-mec-09:4004MEC:USR:CLF:01in-air

Connected. This uses a manual controller.
Zyla focusDumbmoxa-mec-09:4003MEC:USR:CLZ:01in air


Zyla rotation scintillatorDumbmox-mec-r62-23:4002MEC:USR:MMS:23in air


  • No labels