Installed at MEC

Connected to PR60 Patch Panel 

ChannelFlangeFeedthruCurrent Use
Upper Row

MEC:USR:MMS:17D2c

D5 (DB9) and D2 (DB9)

Target X (PLS-85)

MEC:USR:MMS:18DEAD
MEC:USR:MMS:19T4beta5 (DB15)SPL Ref Laser
MEC:USR:MMS:20T4beta#3 (DB9)Vacuum Iris
MEC:USR:MMS:21T4beta4 (DB15)Power Meter
MEC:USR:MMS:22T4beta8 (DB15)F-XRTS Z
MEC:USR:MMS:23T4beta6 (DB15)Filter
MEC:USR:MMS:24DEAD
Lower Row

MEC:USR:MMS:25T4beta3 (DB15)F-XRTS X
MEC:USR:MMS:26T4beta#2 (DB9)XTCS Filter Wheel
MEC:USR:MMS:27In-AirN/AOptique Peter Vertical 
MEC:USR:MMS:28In-AirN/AOptique Peter Focus
No Connector
No Connector
MEC:TC1:MMS:22D2cD1 (DB15)XTCS Filter Wheel
MEC:TC1:MMS:23T4beta7 (DB15)F-XRTS Y

Upper Row:

  • MEC:USR:MMS:17
    • PLS-85
    • Routed to NW side of TC
    • Flange D2c, FF D5 Control, FF D3 Encoders
  • MEC:TC1:MMS:26
    • USR:22
    • CA-261-802-16 C01
    • Routed over NW side of TC to T5(beta)/4.
  • MEC:TC1:MMS:22
    • CA-261-802-16 C01
    • Routed over NW side of TC to T5(beta)/5
  • MEC:USR:MMS:20
    • CA-201-804-95
    • Vacuum Iris
    • Routed over NW side of TC to T5beta)/#1
  • MEC:USR:MMS:21
    • Routed clockwise around bottom of TC to B5/B5
    • Displayed as "MXI Z"
  • MEC:USR:MMS:22
    • CA-261-805-43-C00
    • Routed over top of TC to T5(beta)/#3.
  • MEC:USR:MMS:23
    • TC1-MMS-23
    • VT50 Tag
    • Routed over top of TC to T5(beta)/6
  • MEC:USR:MMS:24
    • Not in use.

Lower Row:

  • MEC:USR:MMS:25
    • CA-261-804-70-C00
    • Routed over top of TC to T5(beta)/#2
  • MEC:TC1:MMS:25
    • CA-261-806-28
    • Micos MP-20B 2SM HLS 10E-6 Cable
    • Routed to NW side of TC
    • Flange D2c, FF D8
  • MEC:USR:CLZ:01
    • Routed CW under TC to Optique Peter Vertical Stage
  • MEC:USR:CLF:01
    • Routed CW under TC to Optique Peter Focus Stage
    • Note: On loan to CXI
  • No connector
  • No connector
  • MEC:TC1:MMS:29
    • CA-261-806-28
    • Micos MP-20B 2SM HLS 10E-6 Cable
    • Routed to NW side of TC
    • Flange D2c, FF D6
  • MEC:TC1:MMS:23
    • CA-261-805-23-C00
    • Micos PLS-85 TT19P to HDB15S
    • Routed over top of TC to Talbot Y stage

Connected to Target Chamber Only

  • TT19P -  DB15-MForce (white cable)
    • Routed from NW side of TC over top to T5(beta)/3
    • RS40 Rotation Stage
  • TT19P - CA-261-805-31 (grey cable, DB15)
    • Routed from NW side of TC over top to T5(beta)/#4
    • RS40 Rotation Stage

To Remove

  • CA-261-802-16 C01
    • Routed along bottom W side of TC to the South to near B7
    • Not connected in PR60 patch panel
    • One thick, three thin cables, grey.
    • Connected at SW side of TC to CA-376-423-39-C00 
      • and then to Motor & Encoder, PPS-110-2x316/Stepper Motor (DB25)
    • Will remove later - cable is tangled under bottom of TC.

Camera Cables

  • OPAL8 - Removed
  • GIGE3
    • Network and Power cables - not connected
    • TC1 Alignment
    • Goes to...
  • Thorlabs Plasma Light Source HPLS200 Series
    • Connected to OPAL01 USB Fiber Pair in PR60
  • GIGE5
    • Connected to DAQ TRIG #1
    • Goes to...
  • Green BNC Trigger cable - N side roll-up
  • Black BNC Trigger cable - to somewhere on TC top
  • Thin Black BNC Trigger cable - N side roll-up

Alviums - to-do:

  • Polarimetry
    • Remove power, trigger, communications (fiber+USB)
  • Facility
    • Cleanup power cabling

Grey Cabinet in Access Tunnel

Shelf 2 (Bottom = 1) - IMS Cables (TT19P)

Ending in multiple connectors (assorted)

DB15 + HDB15S
  • VT50 Cable 2, CA-261-802-16-C01
VGA-DB15 + DB9
  • Beam Block, CA-261-803-52 C02
DB15 + DB9
  • CA-261-805-43
2xTT19P to DB9
  • Standard Motor DB9 Cable #7/#8, CA-261-803-72
3xTT19P to DB50
  • XYZ Stages, CA-261-804-61 
  • Timing Tool XYZ, CA-261-804-50-C00

Ending in TT8P or TT19P

  • Pfeiffer Stage
  • Pfeiffer Stage Manipulator
  • MP-20A, XCS-USR-MMS-18, 261-801-81-C01
  • MEC:TC1:MMS:25 / RS40 Rotation Stage, LN03122
  • CA-261-801-81-C01, LN03118

Shelf 3 - IMS Cables (TT19P)

Ending in DB9

  • Filter Wheel Cable, MEC-TC1-MMS-01, CA-261-803-71-C00
  • Filter Wheel Cable, MEC-TC1-MMS-02, CA-261-803-71-C00
  • Filter Wheel Cable, MEC-TC1-MMS-02, CA-261-803-71-C00
  • Micos Beam Block, CA-261-804-72-C00
  • FS Waveplate Motor Power Cable, CA-261-805-33-C0
  • FS Waveplate Motor Power Cable, CA-261-805-33-C0
  • MEC Micos AFW-65 HVAC Motor Cable (filterwheel), CA-261-803-72
  • MEC Micos AFW-65 HVAC Stage Cable, Blast Shield, CA-261-804-70
  • CA-261-84-95 C00
  • Von Hamos
  • VT50 incomplete, ending 2xDB9: 6, CA-261-802-16
  • Standard Motor DB9 Cables #1/#2
  • Standard Motor DB9 Cables #3/#4
  • Standard Motor DB9 Cables #5/#6

Ending in DB15

  • VT50 Complete: TC1:MMS:22, V-AXIS, CA-261-802-16 + Mercury 3000

Ending in HDB15S

  • Talbot, PLS85, 1, CA-261-805-23

  • USR:MMS:20, PLS85, 2, CA-261-805-23

  • Navitar Lens Control Cable, Navitar Focus

  • CA-261-805-62 C03

  • CA-261-805-80 C00

  • PLS85, CA-261-805-23

  • Navitar Lens Control Cable, Navitar Zoom, CA-261-801-62-C03

  • CA-261-801-62 C03


New cable labeling starting  

PV label at patch panelIOCTerminal Server PortMForce Controller PortFlange on chamberPort on chamberMisc.Motor type
MEC:USR:MMS:17ioc-mec-usrppl-imsmoxa-mec-09:4005R62 E16/17 #1D2cD2, D5Main Target Stage TGXPLS85 in vacuum
MEC:USR:MMS:18not enabled moxa-mec-09:4006R62 E16/17 #2not connected-mforce chassis channel broken
MEC:USR:MMS:19ioc-mec-tc1-vt50-imsmoxa-mec-09:4007R62 E16/17 #3T55SPL ref laserVT50L-100 mm
MEC:USR:MMS:20ioc-mec-usrppl-imsmoxa-mec-09:4008R62 E16/17 #4T5#1SPL vacuum iris-
MEC:USR:MMS:21ioc-mec-usrppl-imsmoxa-mec-r62-23:4001R62 E08/09 #1T54SPL power meterVT50L-300 mm
MEC:USR:MMS:22ioc-mec-usrppl-imsmoxa-mec-r62-23:4002R62 E08/09 #2not connected-

MEC:USR:MMS:23ioc-mec-usrppl-imsmoxa-mec-r62-23:4003R62 E08/09 #3 T56SPL filterVT50-100 mm
MEC:USR:MMS:24ioc-mec-usrppl-imsmoxa-mec-r62-23:4004R62 E08/09 #4not connected-

MEC:USR:MMS:25ioc-mec-usrppl-imsmoxa-mec-09:4001R62 E18/19 #1T53Vacuum filter wheel
MEC:USR:MMS:26ioc-mec-usrppl-imsmoxa-mec-09:4002R62 E18/19 #2T5#2

MEC:USR:MMS:27not enabledmoxa-mec-09:4003R62 E18/19 #3in air detector standNAOptique Peter Vertical stageUTS??
MEC:USR:MMS:28not enabledmoxa-mec-09:4004R62 E18/19 #4not connected-

MEC:TC1:MMS:22ioc-mec-tc1-vt50-imsdigi-mec-07:2108R64A E22/23 #4not connected-

MEC:TC1:MMS:23ioc-mec-tc1-vt50-imsdigi-mec-08:2112R64B E24/25 #4not connected-



  • No labels