SPL Connections

NameConnectionDestinationPV
IMS Motors
SPL Ref LaserVacuum cables connected into T5(beta)/5 labeled "ref laser"PR60MEC:TC1:MMS:22
Power Meter StageVacuum cables connected into T5(beta)/4 labeled "SPL pwrmtr stg"PR60MEC:TC1:MMS:26
Polarimetry delay lineVacuum cables connected into T5(beta)/#3 labeled "polar delay"PR60MEC:USR:MMS:22
Vacuum IrisVacuum cables connected into T5(beta)/#1 labeled "SPL vac iris"PR60MEC:USR:MMS:20
MXI Long StageB5/B5PR60MEC:USR:MMS:21
Newport Motors
SPL M5 Tip - TRA  B7/H1XPS2/#1MEC:PPL:MMN:09
SPL M5 Tilt - LTA2PPV6B7/H3XPS2/#2MEC:PPL:MMN:10
TSO focus - LTAB5/B6XPS1/#7MEC:PPL:MMN:07
TSO hor - LTA "Lat X"B5/B4XPS2/#4MEC:PPL:MMN:12
TSO vert "TSO Vertical Y"B7/H2XPS2/#3MEC:PPL:MMN:11
Input X - MFAVacuum cables connected into T5(beta)/*1 labeled "*1" (disregard "polar input/polar output" labels for these six stages)XPS3/#1MEC:PPL:MMN:17
Input Y - MFAVacuum cables connected into T5(beta)/*2 labeled "*2"XPS3/#2MEC:PPL:MMN:18
Input Z - MFAVacuum cables connected into T5(beta)/*3 labeled "*3"XPS3/#3MEC:PPL:MMN:19
Output X - MFAVacuum cables connected into T5(beta)/*4 labeled "*4"XPS3/#4MEC:PPL:MMN:20
Output Y - MFAVacuum cables connected into T5(beta)/*5 labeled "*5"XPS3/#5MEC:PPL:MMN:21
Output Z - MFAVacuum cables connected into T5(beta)/*6 labeled "*6"XPS3/#6MEC:PPL:MMN:22
Miscellaneous Connections
Power meter cooling lines (2)to T12

Power meter data cableto T12


LPL Motors 

Note: Here we are reusing the Newport motor connections for the Polarimetry Input/Output stages.

NameConnectionDestinationPV
West XVacuum cables connected into T5(beta)/*1 labeled "*1" (disregard "polar input/polar output" labels for these six stages)XPS3/#1MEC:PPL:MMN:17
West YVacuum cables connected into T5(beta)/*2 labeled "*2"XPS3/#2MEC:PPL:MMN:18
West ZVacuum cables connected into T5(beta)/*3 labeled "*3"XPS3/#3MEC:PPL:MMN:19
East XVacuum cables connected into T5(beta)/*4 labeled "*4"XPS3/#4MEC:PPL:MMN:20
East YVacuum cables connected into T5(beta)/*5 labeled "*5"XPS3/#5MEC:PPL:MMN:21
East ZVacuum cables connected into T5(beta)/*6 labeled "*6"XPS3/#6MEC:PPL:MMN:22


Detectors - To Do

NameVacuum FibersAir FibersVacuum PowerAir Power
B-Dot



ePix10k - Quad 0
PR60/Quad 0 to B2/(#1,#2)

ePix10k - Quad 1

PR60/Quad 1 (found disconnected on flange)

"epix100a epix 1" connected D2d/next to upper fiber pair, labeled "GOOD" on flange.



ePix10k - Quad 2

PR60/Quad 2 to B2/(#5,#6)



ePix10k - Quad 3

PR60/Quad 3 to

B2/(#7,#8)





"epix100a epix 0" connected to D2d/lower fiber pair



"Quad 1" fiber disconnected from PR60.

Corresponding feedthru (B2/#3,#4) has been failing in the past, no replacement part available, so we had to switch over to another flange feedthru.



  • No labels