Host Configuration
Current naming conventions:
- Camera - gige-mec-camXX
- gige-mec-XX is the ECS standard
- Camera IOC - ioc-mec-gigeXX
Unresponsive cameras (4 April 2023, also see comments in table below):
- 01-10: 01, 02, 03, 04, 06, 10
- 11-20: 11, 12, 15, 17
- 21-30: None
- 31-40: 33, 35
Comments on host naming and use:
- Current usage combines beamline and laser camera IOCs on the ioc-mec-las-gige[01-04].
- The large format MakoG234B cameras have issues on ioc-mec-las-gige01 (see - LCLSECSD-1825Getting issue details... STATUS ).
- There are currently 8 live and non-laser cameras running on these hosts are 07 08 13 14 18 29 20 21. although not all of the IOCs are enabled.
- ioc-mec-las-gige04 has a FEZ interface for pvDaq work.
- Comment from Tyler: They were labeled as "las" hosts because at the time they were being used to support gige cameras that were being added to the laser system. It doesn't matter what a host is labeled, what is important is the subnet that it operates on. If these hosts are on the MEC subnet, then there's really no reason not to use them as general purpose hosts if they are not overburdened
Build notes (4 April 2023; peregrin):
- R3.7.0/R1.3.0 is required for:
- MakoG032B cameras #7-#15, #34-#35: support added in common/R3.7.0.
- MantaG033B cameras #29-#33: configuration files added in mec/R1.3.0.
- MakoG234B cameras #36-#39.
- common/R3.7.0 is only supported for RHEL7 hosts
- Build R3.3.0/R1.1.1 is used for RHEL5 hosts:
- This is deprecated.
- But can be used for non-MakoG032B cameras that have camera numbers < 29.
- ioc-mec-las-evr-01 (RHEL7) is already hosting
- ioc-mec-las-evr-01
- ioc-mec-spec-01, 02, 03, and 04
- so removed from use as a GigE host (for now)
Camera Type | Size (k) |
---|---|
MakoG032B | 324 |
MakoG234B | 2354 |
MantaG033B | 323 |
MantaG046B | 452 |
MantaG134B | 1441 |
Host | OS | gigECam:common/mec | Enabled gigE IOCs | Disabled gigE IOCs | |||||||
---|---|---|---|---|---|---|---|---|---|---|---|
ioc-mec-las-gige01 | RHEL7 | R3.7.0/R1.3.0 | 25 | 26 | 36 | 37 | 38 | 39 | 7, 9, 10, 11, 12 | ||
ioc-mec-las-gige02 | RHEL7 | R3.7.0/R1.3.0 | 13 | 14 | 15 | 24 | 27 | 34 | 35 | ||
ioc-mec-las-gige03 | RHEL7 | R3.7.0/R1.3.0 | 8 | 28 | 29 | 30 | 31 | 32 | 33 | 40 | |
ioc-mec-las-gige04 | RHEL7 | R3.7.0/R1.3.0 | 16 | 18 | 19 | 20 | 21 | 17 | |||
ioc-mec-las-evr-01 | RHEL7 | ||||||||||
ioc-mec-gige01 | RHEL5 | R3.3.0/R1.1.1 | 1 | 2 | |||||||
ioc-mec-imb02 | RHEL5 | R3.3.0/R1.1.1 | 22 | 23 | |||||||
ioc-mec-ipimb01 | RHEL5 | R3.3.0/R1.1.1 |
Camera Aliases (as given in camviewer.cfg)
Table 1
Camera number | Camera alias | Category | Comments |
---|---|---|---|
1 | GigE1_Questar1 | Target Chamber | MantaG145B; Offline |
2 | GigE2_Questar2 | Target Chamber | MantaG145B; Offline |
3 | GigE3 | Target Chamber | MantaG201B; Offline |
4 | GigE4 | Target Chamber | MantaG145B; Offline |
5 | GigE5_TimeTool | Target Chamber | MantaG046B |
6 | GigE6 | Target Chamber | MantaG046B; Offline |
7 | SPL_TC_Alignment | Target Chamber | MakoG032B; Dedicated to the SPL alignment platforms. |
8 | LPL_100J_5 | Laser - LPL | MakoG032B; 100J Upgrade |
9 | GigE9 | Unknown | MakoG032B; Offline |
10 | DEAD_MakoG032B | DEAD | MakoG032B; Offline. Returned frames are blank (all 0) |
11 | MEC_LPL_1 | Laser - LPL | MakoG032B; Offline |
12 | MEC_TC_800nm | Target Chamber | MakoG032B; Offline |
13 | MEC_YAG3 | Beamline | MakoG032B |
14 | MEC_YAG1 | Beamline | MakoG032B; Located in XRT. |
15 | MEC_YAG4 | Beamline | MakoG032B |
16 | MEC_SPL_8 | Laser - SPL | MantaG033B |
17 | MPA2Xtal | Target Chamber | MantaG046B; Offline |
18 | VISAR1 | Target Chamber | MantaG046B |
19 | VISAR2 | Target Chamber | MantaG046B |
20 | VISAR3 | Target Chamber | MantaG046B |
(Continued)
Table 2
Camera number | Camera alias | Category | Comments |
---|---|---|---|
21 | VISAR4 | Target Chamber | MantaG046B |
22 | StrinA | Laser - SPL | MantaG033B |
23 | MPA1In | Laser - SPL | MantaG033B |
24 | Regen | Laser - SPL | MantaG033B |
25 | MPA1Out | Laser - SPL | MantaG033B |
26 | MPA2In | Laser - SPL | MantaG033B |
27 | MPA2Out | Laser - SPL | MantaG033B |
28 | StrinB | Laser - SPL | MantaG033B |
29 | SPFloat1 | Laser - SPL | MantaG145C (1390x1038 vs B's 1388x1038) |
30 | CompOutFF | Laser - SPL | MantaG033B; SPL Compressor; Offline |
31 | CompOutNF | Laser - SPL | MantaG033B; SPL Compressor |
32 | CompInFF | Laser - SPL | MantaG033B; SPL Compressor; Offline |
33 | CompInNF | Laser - SPL | MantaG033B; SPL Compressor; Offline |
34 | TTin | Laser - SPL | MakoG032B; Offline |
35 | TTout | Laser - SPL | MakoG032B; Offline |
36 | LPL_100J_1 | Laser - LPL | MakoG234B; 100J Upgrade |
37 | LPL_100J_2 | Laser - LPL | MakoG234B; 100J Upgrade |
38 | LPL_100J_3 | Laser - LPL | MakoG234B; 100J Upgrade |
39 | LPL_100J_4 | Laser - LPL | MakoG234B; 100J Upgrade |
40 | LPL_100J_6 | Laser - LPL | MakoG032B; 100J Upgrade |
Cameras found in laser area "topas treasures" drawer
Camera Type | MAC Address | Notes |
---|---|---|
Mako G-032B | 000F.325D.6FA1 | In plastic bag. POE 648x492 |
Manta 046B | 000F.314C.5BA2 | POE 780x580 |
Manta 145B | 000F.314C.4D38 | GIGE4. POE 1388x1038 |
Manta 201B 30fps | 000F.314F.38DC | POE 1624x1234 |
Manta 201B 30fps | 000F.314F.426D | POE 1624x1234 |
Manta 201B 30fps | 000F.314F.426E | POE 1624x1234 |