Link to other documentation of the flange maps

Used feedthroughs are shown in bracket, e.g. (3), or in red text.

Standard configuration MFA stages are DB25, 3x3=9 stages per full LPL std config.

B: bottom; T: top; D: door; M:Middle/main

Bottom Flange Map Top Port Map




Connections
Flange numberFlange TypeDB 9DB 15

DB 25

DB 50water cooling setfiber FC/PCSMA fiber

SMA

coaxial

BNCexotic feedthroughdeviceComments
Total
20 (1)51 (6)32 (4)5 (1)3 (3)10 (8)228 (1)3

missing flange B, F and G

B

B1NW160
1111 (IN+OUT)
2



C flange (MEC CDR), NW50 for water cooling

Using: DB50 typically used for XRTS, water cooling typically used for QUADs

B2NW160




8




crappy seal, (not in MEC CDR)

Using: for 4x QUAD

B3NW160

6


11
1

recent design B

Using: 4x DB25 for QUAD power, typically USB for WFS-v triggering

B4NW160
1
1
2
2
  • 2 plugs
  • 1 large hexapod set (78 pins + lemo type)
  • weird 4 pin connector

L flange (MEC CDR), floating SMA

Using: large hexapod set, 1 SMA for timing diode

B5NW1602
8







B flange (MEC CDR)
B6NW1604
111 (IN+OUT)





E flange (MEC CDR), NW50 for water cooling

Using: cooling for other detectors

B7NW160
64







H flange (MEC CDR)
B8NW160
13



6



recent design A

Using: 6 DB15 for MXI smaract

B9ASA 16









Gatevalve + Turbo Maglev 1
B10ASA 16









Gatevalve + Turbo 2

B11

ASA 16









empty (future Maglev 2)
B12NW160









  • chamber gauge xx1
  • relief valve x1 (spring)
  • venting system
















TT1










small viewportfor chamber light (4" optic)
T2










blank
T3










blank
T4









3 small hexapod sets (78 pins + lemo type)

PI updated hexapods

Using: one for MXI, but temporarily

T5
486



4


regular SMA (non floating grounding)
T6
486



4


regular SMA (non floating grounding)
T7










small viewport4" optic
T8










blank
T9










blank
T10










blank
T11




1 (IN+OUT)



4 power meter DATA connectors

dedicated to LPL energy meters and SPL power meters

Using: all 4 specialized connectors and water cooling dedicated for SPL power meter

T12










primary venting system
T13










large porttypically jet port or target chamber light















D1D1a










viewport + shutter

viewport for Questar 1
D1b










FEL in-coupling


D2D2a






3



on CF3.75
D2b










VISAR viewport
D2c
62
2






D flange (MEC CDR)

Using: 1xDB9 for PLS85 target stage

D2d

12








M flange (MEC CDR)
D3










blank

D4

D4a










blank

blank is Questar 1 size
D4b










TP in-coupling


D5D5a










relieve valve x1


D5b










fly tube out-couplingFlange 0.3" offset towards south
D6










blank
D7D7a










viewport + shutter

viewport for Questar 2
D7b










laser viewportWest AB/EF LPL in coupling
D7c










laser viewportEast GH/IJ LPL in coupling
D8










blank















MM1










FDI viewport
M2










viewport + shutter
M3










viewport  + shutter
M4










viewport
M5










viewport
M6










viewport
M7










viewport
M8










laser incoupling
  • No labels