(From the 4/15/10 logbook entry by EKT)

This is the best way to turn the gun on:

While 20-6 modulator is OFF:

  • make sure the MPS Shutter is closed.
  • Disable ampl and phas LLRF feedbacks and "sending I and Q adjust to PAC" on

the RF GUN page (lclshome)

  • Open "RF Gun PAC Destination" and set Q to 0. Set I to 5000 (+/-, doesn't

matter)

  • Turn ON Modulator 20-6
  • Turn ON rate (make sure MPS shutter is still IN)
  • The Wt avg amplitude should be updating and around 4.5 to 5.0 MV.
  • Set desired Amp to 4MV.
  • Enable local Amplitude feedback ONLY (DO NOT ENABLE "Sending I and Q adjust

to PAC" yet).

  • The "New Setpoint" should go to lower limit of the limit setpoint. (for

example, the value in red circle 1 should go to the value in red circle 2). Once this is true, you can ENABLE "Sending I and Q adjust to PAC"

  • This ENABLE will ramp the Gun Amplitude to the value in the "Desired Ampl"

box. Please enter 6MV so the gun will be at its nominal amp. value.

  • No labels