Install
using devel rpms:
http://odev-vm-15.es.net/rpms/perl-perfSONAR_PS-TracerouteMA-config-3.2-1.pSPS.noarch.rpm http://odev-vm-15.es.net/rpms/perl-perfSONAR_PS-TracerouteMA-client-3.2-1.pSPS.noarch.rpm http://odev-vm-15.es.net/rpms/perl-perfSONAR_PS-TracerouteMA-server-3.2-1.pSPS.noarch.rpm
just rpm -Uhv each one.
client complains of need for net::traceroute
$ sudo rpm -Uhv perl-perfSONAR_PS-TracerouteMA-client-3.2-1.pSPS.noarch.rpm error: Failed dependencies: perl(Net::Traceroute) is needed by perl-perfSONAR_PS-TracerouteMA-client-3.2-1.pSPS.noarch
doing a cpan install doesn't work (need rpm headers), run with --nodeps
$ sudo rpm -Uhv --nodeps perl-perfSONAR_PS-TracerouteMA-client-3.2-1.pSPS.noarch.rpm
Configs
all configs in
/afs/slac.stanford.edu/package/perfSONAR-PS/etc
with init.d script edited to point to relevant config files.