The IEPM SVN Location is at:

/afs/slac.stanford.edu/g/scs/net/netmon/repo/svn

SVN Repository Creation

An SVN Repository has been created at /afs/slac.stanford.edu/g/scs/net/netmon/repo/svn. The command to create this was:

$ svnadmin create /afs/slac.stanford.edu/g/scs/net/netmon/repo/svn --fs-type fsfs

Note that we are using fs-type fsfs due to the fact that we are housing the repo on an AFS share.

SVN Project Creation

New projects can be created by IEPM members (with sufficient AFS permissions). Given an existing project with files to be imported, one would run the command:

$ cd <project-path>
$ svn import . file:///afs/slac.stanford.edu/g/scs/net/netmon/repo/svn/<project-name>/trunk

This will recusively add all files within <project-path> into the SVN repositry; whereby it will be located at <project-name>.

The use of /trunk at the end of the path is arbitary; however, it is recommended good practise to facilitate the branching of projects.

Once a project has been initially imported into the SVN database, it is necessary to start working on a 'fresh' version (as the files in the initial import do not 'know' about the SVN). This is achieved with a SVN checkout.