This traceoute is from Al-Quds University (AQU) Abu-Dis to Al-Quds Open University (AOU) Ramallah. It was made by Isam Ishaq of AQU aon 5/10/2007 when the load on the link was 25% of capacity. 195.137.188.* is in the PAI2 Autonomous System (AS) domain. The distance apart of the universities is a few miles so the min-RTT shouold be << 10 ms.

traceroute to 195.137.188.9 (195.137.188.9), 30 hops max, 38 byte packets
 1  195.137.188.89 (195.137.188.89)  1.684 ms  1.279 ms  0.981 ms
 2  195.137.188.241 (195.137.188.241)  91.188 ms  92.504 ms  92.554 ms
 3  195.137.188.9 (195.137.188.9)  91.355 ms  92.240 ms  91.745 ms

Routes from Al-Quds to other Middle Eastern Countries 

Palestine to Turkey 

1  195.137.188.89 (195.137.188.89)  1.099 ms  1.143 ms  1.535 ms Country:Palestinian Territory Code:PS City: Lat:32 Lon:35.25
 2  C1751.quran.alquds.edu (62.90.24.65)  618.938 ms  749.593 ms  747.753 ms Country:Israel Code:IL City: Lat:31.5 Lon:34.75
 3  212.150.38.121 (212.150.38.121)  1330.808 ms  1242.306 ms  1144.684 ms Country:Israel Code:IL City: Lat:31.5 Lon:34.75
 4  gi6-14.bk1-acc4.013bk.net (62.90.133.169)  736.827 ms  854.076 ms  1061.871 ms Country: Code:IL City:Israel Lat:32.0678 Lon:34.7647
 5  gi1-6.bk1-gw.013bk.net (62.90.133.129)  828.614 ms  641.016 ms  722.837 ms Country: Code:IL City:Israel Lat:32.0678 Lon:34.7647
 6  gi5-0.bk1-bb.013bk.net (212.150.232.125)  802.492 ms  656.897 ms  636.405 ms Country:Israel Code:IL City: Lat:31.5 Lon:34.75
 7  * gi1-3.uk-bb.013bk.net (212.150.235.81)  1377.334 ms  1235.008 ms Country:United States Code:US City:Palo Alto Lat:37.4411 Lon:-122.1446
 8  ldn-tch-i1-link.telia.net (213.248.100.25)  1309.646 ms  1450.294 ms  1404.564 ms Country:Europe Code:EU City: Lat:47 Lon:8
 9  ldn-b1-link.telia.net (80.91.250.209)  1402.914 ms  1019.455 ms  1358.132 ms Country:Europe Code:EU City: Lat:47 Lon:8
10  ldn-bb2-pos1-2-0.telia.net (213.248.74.13)  949.290 ms  834.481 ms  1518.749 ms Country:Europe Code:EU City: Lat:47 Lon:8
11  ldn-b3-link.telia.net (80.91.251.13)  476.955 ms  1471.437 ms  1055.034 ms Country:Europe Code:EU City: Lat:47 Lon:8
12  turk-115010-ldn-b3.c.telia.net (213.248.74.10)  1235.904 ms  1249.366 ms  1169.613 ms Country:Europe Code:EU City: Lat:47 Lon:8
13  195.175.7.126 (195.175.7.126)  1064.384 ms  1086.082 ms  1181.825 ms Country:Turkey Code:TR City:Istanbul Lat:41.0186 Lon:28.9647
14  ankM160-gtepeM160.ttnet.net.tr (195.175.7.1)  1044.074 ms  1084.687 ms  1113.656 ms Country:Turkey Code:TR City:Istanbul Lat:41.0186 Lon:28.9647

 Palestine to Iran

 1  195.137.188.89 (195.137.188.89)  1.096 ms  0.848 ms  0.752 ms Country:Palestinian Territory Code:PS City: Lat:32 Lon:35.25
 2  C1751.quran.alquds.edu (62.90.24.65)  35.732 ms  39.687 ms  7.132 ms Country:Israel Code:IL City: Lat:31.5 Lon:34.75
 3  212.150.38.121 (212.150.38.121)  26.205 ms  15.966 ms  67.654 ms Country:Israel Code:IL City: Lat:31.5 Lon:34.75
 4  gi6-14.bk1-acc4.013bk.net (62.90.133.169)  93.405 ms  93.488 ms  58.486 ms Country: Code:IL City:Israel Lat:32.0678 Lon:34.7647
 5  gi1-6.bk1-gw.013bk.net (62.90.133.129)  50.045 ms  39.763 ms  57.159 ms Country: Code:IL City:Israel Lat:32.0678 Lon:34.7647
 6  gi2-0.bk1-bb.013bk.net (212.150.234.158)  103.552 ms  38.158 ms  24.033 ms Country:Israel Code:IL City: Lat:31.5 Lon:34.75
 7  gi3-0.uk-bb.013bk.net (212.150.232.237)  137.074 ms  350.377 ms * Country:Israel Code:IL City: Lat:31.5 Lon:34.75
 8  ldn-tch-i1-link.telia.net (213.248.100.25)  105.444 ms  184.116 ms  95.841 ms Country:Europe Code:EU City: Lat:47 Lon:8
 9  ldn-b1-link.telia.net (80.91.250.209)  137.348 ms  193.387 ms  149.032 ms Country:Europe Code:EU City: Lat:47 Lon:8
10  ldn-bb1-link.telia.net (80.91.250.91)  158.890 ms  164.808 ms  294.193 ms Country:Europe Code:EU City: Lat:47 Lon:8
11  ldn-b3-link.telia.net (80.91.250.233)  241.848 ms  276.824 ms  157.643 ms Country:Europe Code:EU City: Lat:47 Lon:8
12  turk-115010-ldn-b3.c.telia.net (213.248.74.10)  355.400 ms  460.230 ms  474.755 ms Country:Europe Code:EU City: Lat:47 Lon:8
13  212.156.118.45 (212.156.118.45)  404.786 ms  204.323 ms  222.743 ms Country: Code:TR City:Turkey Lat:37.05 Lon:29.7
     MPLS Label=121568 CoS=7 TTL=1 S=0 Country:United States Code:US City:Palo Alto Lat:37.4411 Lon:-122.1446
14  uls_t1_1-gyt_t1_1.ttnet.net.tr (212.156.118.38)  214.148 ms  242.158 ms  427.746 ms Country: Code:TR City:Turkey Lat:37.05 Lon:29.7
     MPLS Label=121216 CoS=7 TTL=1 S=0 Country:United States Code:US City:Palo Alto Lat:37.4411 Lon:-122.1446
15  * * * Country:United States Code:US City:Palo Alto Lat:37.4411 Lon:-122.1446
16  195.175.5.26 (195.175.5.26)  260.907 ms  283.719 ms  285.331 ms Country: Code:TR City:Turkey Lat:37.05 Lon:29.7
17  217.218.155.65 (217.218.155.65)  216.220 ms  389.867 ms  235.832 ms Country: Code:IR City:Iran Lat:32.0922 Lon:51.0289
18  217.218.155.49 (217.218.155.49)  286.088 ms  304.982 ms  217.196 ms Country: Code:IR City:Iran Lat:32.0922 Lon:51.0289
19  217.218.155.33 (217.218.155.33)  254.699 ms Country: Code:IR City:Iran Lat:32.0922 Lon:51.0289

Palestine to Jordan

 1  195.137.188.89 (195.137.188.89)  1.053 ms  0.852 ms  0.756 ms Country:Palestinian Territory Code:PS City: Lat:32 Lon:35.25
 2  C1751.quran.alquds.edu (62.90.24.65)  453.167 ms  369.134 ms  240.510 ms Country:Israel Code:IL City: Lat:31.5 Lon:34.75
 3  212.150.38.121 (212.150.38.121)  1111.678 ms  881.316 ms  767.018 ms Country:Israel Code:IL City: Lat:31.5 Lon:34.75
 4  gi6-14.bk1-acc4.013bk.net (62.90.133.169)  657.366 ms  669.897 ms  699.955 ms Country: Code:IL City:Israel Lat:32.0678 Lon:34.7647
 5  gi1-6.bk1-gw.013bk.net (62.90.133.129)  679.534 ms  640.347 ms  583.298 ms Country: Code:IL City:Israel Lat:32.0678 Lon:34.7647
 6  gi2-0.bk1-bb.013bk.net (212.150.234.158)  576.776 ms  716.905 ms  725.253 ms Country:Israel Code:IL City: Lat:31.5 Lon:34.75
 7  gi4-1.bk3-bb.013bk.net (212.150.232.106)  487.078 ms  325.295 ms  282.303 ms Country:Israel Code:IL City: Lat:31.5 Lon:34.75
     MPLS Label=108 CoS=7 TTL=1 S=0 Country:United States Code:US City:Palo Alto Lat:37.4411 Lon:-122.1446
 8  po1-2.ny-bb.013bk.net (212.150.232.121)  177.521 ms  330.772 ms  230.843 ms Country:Israel Code:IL City: Lat:31.5 Lon:34.75
 9  12.118.94.57 (12.118.94.57)  240.761 ms  262.105 ms  258.492 ms Country:United States Code:US City: Lat:38 Lon:-97
10  12.122.82.158 (12.122.82.158)  265.904 ms  230.514 ms  175.508 ms Country:United States Code:US City: Lat:38 Lon:-97
     MPLS Label=31910 CoS=7 TTL=1 S=0 Country:United States Code:US City:Palo Alto Lat:37.4411 Lon:-122.1446
11  tbr2.wswdc.ip.att.net (12.122.10.54)  209.361 ms  288.242 ms  220.239 ms Country:United States Code:US City: Lat:38 Lon:-97
     MPLS Label=32767 CoS=7 TTL=1 S=0 Country:United States Code:US City:Palo Alto Lat:37.4411 Lon:-122.1446
12  ar9.wswdc.ip.att.net (12.123.8.189)  429.416 ms  222.082 ms  298.321 ms Country:United States Code:US City:Bethesda Lat:38.9878 Lon:-77.1262
13  att-gw.dc.opentransit.net (192.205.32.166)  232.113 ms  210.392 ms  191.631 ms Country:United States Code:US City:Lake Mary Lat:28.7578 Lon:-81.3397
14  po6-0.nykcr3.NewYork.opentransit.net (193.251.240.134)  236.010 ms  164.826 ms  167.667 ms Country:France Code:FR City:Paris Lat:48.8667 Lon:2.3333
15  po7-0.nykbb3.NewYork.opentransit.net (193.251.241.242)  164.436 ms  164.948 ms  205.176 ms Country:France Code:FR City:Paris Lat:48.8667 Lon:2.3333
16  * * * Country:United States Code:US City:Palo Alto Lat:37.4411 Lon:-122.1446
17  213.139.32.206 (213.139.32.206)  328.113 ms  256.877 ms  239.157 ms Country:Jordan Code:JO City:Amman Lat:31.95 Lon:35.9333

Palestine(West Bank) to Palestine(Gaza)

 1  195.137.188.89 (195.137.188.89)  1.192 ms  1.125 ms  0.965 ms Country:Palestinian Territory Code:PS City: Lat:32 Lon:35.25
 2  C1751.quran.alquds.edu (62.90.24.65)  15.304 ms  7.440 ms  7.741 ms Country:Israel Code:IL City: Lat:31.5 Lon:34.75
 3  212.150.38.121 (212.150.38.121)  72.511 ms  106.878 ms  57.033 ms Country:Israel Code:IL City: Lat:31.5 Lon:34.75
 4  gi6-14.bk1-acc4.013bk.net (62.90.133.169)  46.252 ms  125.435 ms  92.454 ms Country: Code:IL City:Israel Lat:32.0678 Lon:34.7647
 5  212.150.38.22 (212.150.38.22)  152.465 ms  23.906 ms  59.802 ms Country:Israel Code:IL City: Lat:31.5 Lon:34.75
 6  85.114.96.250 (85.114.96.250)  21.731 ms  47.366 ms  35.527 ms Country:Palestinian Territory Code:PS City: Lat:32 Lon:35.25
 7  85.114.104.26 (85.114.104.26)  224.366 ms  30.158 ms  33.789 ms Country:Palestinian Territory Code:PS City: Lat:32 Lon:35.25
 8  85.114.105.35 (85.114.105.35)  50.731 ms  30.076 ms  40.921 ms Country:Palestinian Territory Code:PS City: Lat:32 Lon:35.25

Palestine to Saudia Arabia

 1  195.137.188.89 (195.137.188.89)  1.268 ms  1.162 ms  0.965 ms Country:Palestinian Territory Code:PS City: Lat:32 Lon:35.25
 2  C1751.quran.alquds.edu (62.90.24.65)  16.459 ms  40.846 ms  7.285 ms Country:Israel Code:IL City: Lat:31.5 Lon:34.75
 3  212.150.38.121 (212.150.38.121)  62.276 ms  52.814 ms  105.412 ms Country:Israel Code:IL City: Lat:31.5 Lon:34.75
 4  gi6-14.bk1-acc4.013bk.net (62.90.133.169)  71.335 ms  59.503 ms  110.762 ms Country: Code:IL City:Israel Lat:32.0678 Lon:34.7647
 5  gi1-6.bk1-gw.013bk.net (62.90.133.129)  87.637 ms  83.868 ms  87.390 ms Country: Code:IL City:Israel Lat:32.0678 Lon:34.7647
 6  gi2-0.bk1-bb.013bk.net (212.150.234.158)  77.660 ms  22.301 ms  16.599 ms Country:Israel Code:IL City: Lat:31.5 Lon:34.75
 7  * * gi3-0.uk-bb.013bk.net (212.150.232.237)  113.272 ms Country:United States Code:US City:Palo Alto Lat:37.4411 Lon:-122.1446
 8  ldn-tch-i1-link.telia.net (213.248.100.25)  106.490 ms  96.932 ms  96.445 ms Country:Europe Code:EU City: Lat:47 Lon:8
 9  ldn-b1-link.telia.net (80.91.250.209)  116.606 ms  136.417 ms  163.307 ms Country:Europe Code:EU City: Lat:47 Lon:8
10  ldn-bb1-pos0-3-0.telia.net (213.248.74.5)  104.497 ms  175.533 ms  136.645 ms Country:Europe Code:EU City: Lat:47 Lon:8
11  adm-bb1-pos6-0-0.telia.net (213.248.65.150)  123.919 ms  106.483 ms  192.567 ms Country:Europe Code:EU City: Lat:47 Lon:8
12  adm-b3-pos1-2-0.telia.net (213.248.64.70)  206.929 ms  113.769 ms  207.273 ms Country:Europe Code:EU City: Lat:47 Lon:8
13  ge2-2.1000M.asd9nxg1.ip.tele.dk (195.215.109.89)  119.673 ms  127.403 ms  112.817 ms Country:Denmark Code:DK City:Tranbjerg Lat:56.1 Lon:10.15
14  pos3-0.2488M.ldn2nxg1.ip.tele.dk (83.88.27.118)  157.464 ms  111.350 ms  261.633 ms Country:Denmark Code:DK City:Tranbjerg Lat:56.1 Lon:10.15
15  cpe.ge0-2.0xc3d76d86.ldn2nxg1.customer.tele.dk (195.215.109.134)  203.468 ms  206.696 ms  235.949 ms Country:Denmark Code:DK City:Tranbjerg Lat:56.1 Lon:10.15
16  10ge-3-1-d.alice.mer.as33970.net (89.238.128.137)  246.227 ms  131.724 ms  225.137 ms Country:Germany Code:DE City: Lat:51 Lon:9
17  * * *
18  * *

Palestine to Turkey

 1  195.137.188.89 (195.137.188.89)  1.589 ms  1.154 ms  0.970 ms Country:Palestinian Territory Code:PS City: Lat:32 Lon:35.25
 2  C1751.quran.alquds.edu (62.90.24.65)  14.750 ms  7.185 ms  7.131 ms Country:Israel Code:IL City: Lat:31.5 Lon:34.75
 3  212.150.38.121 (212.150.38.121)  18.452 ms  16.928 ms  16.165 ms Country:Israel Code:IL City: Lat:31.5 Lon:34.75
 4  gi6-14.bk1-acc4.013bk.net (62.90.133.169)  40.610 ms  16.543 ms  16.436 ms Country: Code:IL City:Israel Lat:32.0678 Lon:34.7647
 5  gi1-6.bk1-gw.013bk.net (62.90.133.129)  16.377 ms  65.343 ms  37.133 ms Country: Code:IL City:Israel Lat:32.0678 Lon:34.7647
 6  gi5-0.bk1-bb.013bk.net (212.150.232.125)  17.110 ms  16.869 ms  32.079 ms Country:Israel Code:IL City: Lat:31.5 Lon:34.75
 7  gi3-0.uk-bb.013bk.net (212.150.232.237)  142.100 ms  111.714 ms  134.514 ms Country:Israel Code:IL City: Lat:31.5 Lon:34.75
 8  ldn-tch-i1-link.telia.net (213.248.100.25)  105.300 ms  279.583 ms  95.554 ms Country:Europe Code:EU City: Lat:47 Lon:8
 9  ldn-b1-link.telia.net (80.91.250.209)  95.745 ms  146.880 ms  139.346 ms Country:Europe Code:EU City: Lat:47 Lon:8
10  ldn-bb2-link.telia.net (80.91.250.15)  191.020 ms  125.799 ms  138.066 ms Country:Europe Code:EU City: Lat:47 Lon:8
11  ldn-b3-link.telia.net (80.91.250.237)  100.700 ms  135.005 ms  98.872 ms Country:Europe Code:EU City: Lat:47 Lon:8
12  turk-115010-ldn-b3.c.telia.net (213.248.74.10)  182.799 ms  195.000 ms  165.609 ms Country:Europe Code:EU City: Lat:47 Lon:8
13  212.156.118.45 (212.156.118.45)  195.095 ms  172.128 ms  221.593 ms Country: Code:TR City:Turkey Lat:37.05 Lon:29.7
     MPLS Label=130720 CoS=7 TTL=1 S=0 Country:United States Code:US City:Palo Alto Lat:37.4411 Lon:-122.1446
14  uls_t1_1-gyt_t1_1.ttnet.net.tr (212.156.118.38)  230.857 ms  237.201 ms  193.047 ms Country: Code:TR City:Turkey Lat:37.05 Lon:29.7
     MPLS Label=130192 CoS=7 TTL=1 S=0 Country:United States Code:US City:Palo Alto Lat:37.4411 Lon:-122.1446
15  * * *
16  * * *
17  212.156.230.2 (212.156.230.2)  180.717 ms  191.232 ms  244.918 ms Country:Turkey Code:TR City:Kocaeli Lat:40.7669 Lon:29.9169
18  193.140.0.26 (193.140.0.26)  183.257 ms  187.375 ms  189.698 ms Country:Turkey Code:TR City:Ankara Lat:39.9272 Lon:32.8644
19  *

Palestine to Dubai

 1  195.137.188.89 (195.137.188.89)  1.105 ms  1.396 ms  0.784 ms Country:Palestinian Territory Code:PS City: Lat:32 Lon:35.25
 2  C1751.quran.alquds.edu (62.90.24.65)  15.712 ms  7.660 ms  7.480 ms Country:Israel Code:IL City: Lat:31.5 Lon:34.75
 3  212.150.38.121 (212.150.38.121)  17.592 ms  58.548 ms  25.483 ms Country:Israel Code:IL City: Lat:31.5 Lon:34.75
 4  gi6-14.bk1-acc4.013bk.net (62.90.133.169)  16.542 ms  39.094 ms  57.992 ms Country: Code:IL City:Israel Lat:32.0678 Lon:34.7647
 5  gi1-6.bk1-gw.013bk.net (62.90.133.129)  49.818 ms  23.901 ms  16.139 ms Country: Code:IL City:Israel Lat:32.0678 Lon:34.7647
 6  gi2-0.bk1-bb.013bk.net (212.150.234.158)  21.403 ms  17.029 ms  30.603 ms Country:Israel Code:IL City: Lat:31.5 Lon:34.75
 7  gi3-0.uk-bb.013bk.net (212.150.232.237)  105.787 ms *  181.065 ms Country:Israel Code:IL City: Lat:31.5 Lon:34.75
 8  ldn-tch-i1-link.telia.net (213.248.100.25)  100.399 ms  97.099 ms  129.892 ms Country:Europe Code:EU City: Lat:47 Lon:8
 9  ldn-b1-link.telia.net (80.91.250.209)  97.143 ms  206.167 ms  104.424 ms Country:Europe Code:EU City: Lat:47 Lon:8
10  ldn-bb1-link.telia.net (80.91.250.91)  112.842 ms  106.365 ms  163.426 ms Country:Europe Code:EU City: Lat:47 Lon:8
11  ldn-b3-link.telia.net (80.91.250.233)  96.240 ms  132.578 ms  147.067 ms Country:Europe Code:EU City: Lat:47 Lon:8
12  verizon-118106-ldn-b3.telia.net (213.248.104.46)  134.051 ms  114.871 ms  109.121 ms Country:Europe Code:EU City: Lat:47 Lon:8
13  so-1-2-0.TR2.LND2.ALTER.NET (146.188.4.41)  237.807 ms  149.259 ms  172.630 ms Country:United Kingdom Code:GB City:Cambridge Lat:52.2 Lon:0.11670000000001
14  so-6-0-0.XR2.LND2.ALTER.NET (146.188.7.233)  195.718 ms  122.937 ms  140.120 ms Country:United Kingdom Code:GB City:Cambridge Lat:52.2 Lon:0.11670000000001
15  pos3-0.cr2.lnd5.gbb.uk.uu.net (158.43.233.245)  233.438 ms  97.070 ms  149.015 ms Country:United Kingdom Code:GB City:Cambridge Lat:52.2 Lon:0.11670000000001
16  pos6-0.cr2.lnd6.gbb.uk.uu.net (158.43.253.146)  125.291 ms  102.973 ms  120.913 ms Country:United Kingdom Code:GB City:Cambridge Lat:52.2 Lon:0.11670000000001
17  POS0-0.GW2.lnd6.alter.net (158.43.193.238)  98.906 ms  97.971 ms  96.366 ms Country:United Kingdom Code:GB City:Cambridge Lat:52.2 Lon:0.11670000000001
18  uuk203668.uk.customer.alter.net (158.43.0.10)  307.141 ms  318.895 ms  350.088 ms Country:United Kingdom Code:GB City:Cambridge Lat:52.2 Lon:0.11670000000001
19  80.227.0.202 (80.227.0.202)  359.849 ms  353.741 ms  373.624 ms Country: Code:AE City:Dubai Lat:25.2521 Lon:55.28
20  * * *
21  80.227.0.26 (80.227.0.26)  304.728 ms  400.276 ms  324.461 ms Country: Code:AE City:Dubai Lat:25.2521 Lon:55.28
22  80.227.96.19 (80.227.96.19)  334.497 ms  339.995 ms  310.001 ms Country: Code:AE City:Dubai Lat:25.2521 Lon:55.28
23  buid.ac.ae (80.227.105.236)  333.684 ms  313.091 ms  314.689 ms Country: Code:AE City:Dubai Lat:25.2521 Lon:55.28

Palestine to Cyprus

1  195.137.188.89 (195.137.188.89)  1.561 ms  1.380 ms  0.783 ms Country:Palestinian Territory Code:PS City: Lat:32 Lon:35.25
 2  C1751.quran.alquds.edu (62.90.24.65)  36.458 ms  7.224 ms  7.618 ms Country:Israel Code:IL City: Lat:31.5 Lon:34.75
 3  212.150.38.121 (212.150.38.121)  37.902 ms  87.832 ms  16.384 ms Country:Israel Code:IL City: Lat:31.5 Lon:34.75
 4  gi6-14.bk1-acc4.013bk.net (62.90.133.169)  16.429 ms  16.725 ms  28.153 ms Country: Code:IL City:Israel Lat:32.0678 Lon:34.7647
 5  gi1-6.bk1-gw.013bk.net (62.90.133.129)  133.020 ms *  16.728 ms Country: Code:IL City:Israel Lat:32.0678 Lon:34.7647
 6  gi5-0.bk1-bb.013bk.net (212.150.232.125)  16.881 ms  16.533 ms  61.364 ms Country:Israel Code:IL City: Lat:31.5 Lon:34.75
 7  gi3-0.uk-bb.013bk.net (212.150.232.237)  118.611 ms  161.404 ms  124.709 ms Country:Israel Code:IL City: Lat:31.5 Lon:34.75
 8  ldn-tch-i1-link.telia.net (213.248.100.25)  240.984 ms  198.323 ms  204.380 ms Country:Europe Code:EU City: Lat:47 Lon:8
 9  ldn-b1-link.telia.net (80.91.250.209)  102.470 ms  96.147 ms  96.323 ms Country:Europe Code:EU City: Lat:47 Lon:8
10  ldn-bb1-pos0-3-0.telia.net (213.248.74.5)  97.835 ms  136.814 ms  96.788 ms Country:Europe Code:EU City: Lat:47 Lon:8
11  ffm-bb1-link.telia.net (80.91.249.9)  112.255 ms  112.662 ms  132.954 ms Country:Europe Code:EU City: Lat:47 Lon:8
12  ffm-b6-link.telia.net (80.91.251.149)  113.337 ms  146.994 ms  121.921 ms Country:Europe Code:EU City: Lat:47 Lon:8
13  dante-01232-ffm-b2.c.telia.net (213.248.77.90)  113.187 ms  113.614 ms  128.069 ms Country:Europe Code:EU City: Lat:47 Lon:8
14  so-6-2-0.rt1.gen.ch.geant2.net (62.40.112.21)  220.716 ms  180.239 ms  372.744 ms Country:United Kingdom Code:GB City:Cambridge Lat:52.2 Lon:0.11670000000001
15  so-2-0-0.rt1.mil.it.geant2.net (62.40.112.34)  524.052 ms  1152.499 ms  775.920 ms Country:United Kingdom Code:GB City:Cambridge Lat:52.2 Lon:0.11670000000001
16  geant.it1.it3.eumedconnect.net (83.97.90.1)  361.925 ms  205.562 ms  184.066 ms Country:United Kingdom Code:GB City:Cambridge Lat:52.2 Lon:0.11670000000001
17  it3.cy3.eumedconnect.net (83.97.88.2)  230.398 ms  205.664 ms  207.261 ms Country:United Kingdom Code:GB City:Cambridge Lat:52.2 Lon:0.11670000000001
18  * * *
19  L3-LEF-A-G101.cynet.ac.cy (82.116.192.18)  238.428 ms  260.682 ms  225.789 ms Country:Cyprus Code:CY City:Lefkosia Lat:35.1667 Lon:33.3667
20  cynet-intercol.cynet.ac.cy (82.116.192.38)  236.938 ms  211.134 ms  225.411 ms Country:Cyprus Code:CY City:Lefkosia Lat:35.1667 Lon:33.3667
21  w2k3web.intercol.edu (82.116.203.18)  254.235 ms  280.926 ms  289.679 ms Country:Cyprus Code:CY City:Nicosia Lat:35.1667 Lon:33.3667

  • No labels