Event

See the report from Netblocks November 15th, 2019 where it says Network data from the NetBlocks internet observatory confirm disruptions with multiple fixed-line and mobile providers in Iran, amid protests against rising fuel prices. The outages have partial (update: now near-total, see below) impact at the time of writing affecting multiple cities including Tehran.

Daily Impact on some metrics

Unreachability

Looking at the PingER daily Unreachability (I.e. all up to 30 pings sent each 30 minutes do not respond, see here for more details) metric for the Iran target host we see below:

Notes:

  • The measurements are all from the monitor at SLAC identified as EDU.SLC.STANFORD.PINGER.
  • The targets (or Remote-sites) are all in Iran (they all identified by their nickname which begins with the TLD for Iran (IR.)
  • IR.IASBS.AC.N1 has not been reachable since we started monitoring it in July 2019, so it can be ignored.

Packet loss

Or see the daily losses below:

Notes:

IR.IUT.AC.N1 (aka www.iut.ac.ir) has had similar losses (> 2%) going back over 3 months and could be ignored. 

Estimated throughput

Or the estimated throughput

Aggregated losses

Summary for Sites in Iran seen from EDU.SLAC.STANFORD.PINGER 

Tickmin25th%avgmedian75th%90th%95th%maxiqrstd dev# pairs
19Nov010.0000.0001.1880.0000.1898.3678.3678.3670.1892.9198
19Nov020.0000.0001.2560.2840.3797.5887.5887.5880.3792.6078
19Nov030.0000.0000.5290.0950.5682.7222.7222.7220.5680.9338
19Nov040.0000.0000.9980.3790.7585.2645.2645.2640.7581.7758
19Nov050.0000.0001.0950.3781.0425.1525.1525.1521.0421.7598
19Nov060.0000.0000.9000.1890.3795.3425.3425.3420.3791.8188
19Nov070.0000.0001.0350.7421.5783.3143.3143.3141.5781.2388
19Nov080.0000.0001.1120.2840.3797.1947.1947.1940.3792.4718
19Nov090.0000.1891.4730.3790.9478.3788.3788.3780.7582.8158
19Nov100.0000.1891.5010.8081.3266.9666.9666.9661.1372.2938
19Nov110.0000.1890.8020.6470.7262.0522.0522.0520.5370.7348
19Nov120.0000.0000.7380.2840.3794.0064.0064.0060.3791.3438
19Nov130.0000.0001.1740.3791.3655.4085.4085.4081.3651.8218
19Nov140.0000.0001.5910.7421.2945.8505.8505.8501.2942.2098
19Nov150.0000.0000.7770.0950.1893.6613.6613.6610.1891.3838
19Nov160.1890.1898.4125.30316.37321.16421.16421.16416.1848.8878
19Nov170.0000.56831.33133.08639.86881.37881.37881.37839.30030.0456
19Nov180.379.25.0230.62074.07174.07174.07174.071.42.4773
19Nov190.0001.12035.1883.43379.72191.66791.66791.66778.60146.3155
19Nov200.000.0.1840.1890.3620.3620.3620.362.0.1813
19Nov210.0000.0001.6480.1893.4907.2637.2637.2633.4902.7787

Median value of medians is 0.379

Hosts monitored in Iran

Nick name

IP NameSiteLocation
IR.AC.MOFIDU.WWW
www.mofidu.ac.ir
Mofid University 
Mofid
IR.AC.ZNU.WWW
www.znu.ac.ir
University of Zanjan
Zanjan
IR.IRANBBF.WWW 
www.iranbbf.ir
Federation Islamic Republic Iran Body Building and Fitness
Tehran
IR.IRISSF
irissf.ir
Azadi Sports Complex, Azad Road Karaj
Tehran
IR.IUT.AC.N1
www.iut.ac.ir
Isfahan University of TechnologyIsfahan
IR.SABANET.WWW
www.sabanet.ir
Saha Data Transmission Company
Tehran
IR.SHARIF
www.sharif.ir
Sharif University
Tehran
IR.UT.AC.N1
www.ut.ac.ir
University of Tehran 
Tehran 

Maps of the targets can be seen below (figures from https://www.slac.stanford.edu/comp/net/wan-mon/viper/pinger-coverage-gmap.html). 

TehranIran

hourly Impact on ping measurements

Looking in more detail

www.mofidu.ac.irMofid
www.znu.ac.ir
Zanjan
www.iranbbf.irTehran
irissf.irTehran
www.iut.ac.irIsfahan
www.sabanet.irTehran
www.sharif.irTehran
www.ut.ac.irTehran




  • No labels