Two configuration files exist that control the processing and display of netflow data. Both files are located in conf under the installation directory. The default installation directory is /opt/terapaths-monitoring.

The files are

Configuration File

Description

flowscan.cf

Base file processing and system configuration

JKFlow.xml

Site specific subnet and processing configurations

flowscan.cf

This file specifies the location of the netflow files to be processed and some system wide configurations such as Syslog facilities and the poll frequency to find new netflow files.

Variable

Description

Default

FlowFileGlob

The location and wildcard of netflow files

/var/flows/flows/ft-v05.

ReportClasses

Flowscan modules to use for netflow data processing

JKFlow

WaitSeconds

The poll time to wait for new files into that defined in FlowFileGlob

30

Verbose

 

1

SyslogFacility

The local syslog facility to use for logs

local2

# flowscan Configuration Directives ############################################

# FlowFileGlob (REQUIRED)
# use this glob (file pattern match) when looking for raw flow files to be
# processed, e.g.:
FlowFileGlob /var/flows/flows/*ft-v05.*

# ReportClasses (REQUIRED)
# a comma-seperated list of FlowScan report classes, e.g.:
ReportClasses JKFlow

# WaitSeconds (OPTIONAL)
# This should be <= the "-s" value passed on the command-line to cflowd, e.g.:
WaitSeconds 30

# Verbose (OPTIONAL, non-zero = true)
Verbose 1

# SyslogFacility (REQUIRED)
# defines the syslog facility to use for logging purposes
# use STDOUT to not log to syslog
SyslogFacility local2

JKFlow.xml

  • No labels