$ sudo yum install perl-perfSONAR_PS-SNMPMA.noarch
Loaded plugins: rhnplugin
Setting up Install Process
Resolving Dependencies
--> Running transaction check
---> Package perl-perfSONAR_PS-SNMPMA.noarch 0:3.1-9.pSPS set to be updated
--> Processing Dependency: perl(RRDp) for package: perl-perfSONAR_PS-SNMPMA
--> Processing Dependency: perl(XML::RegExp) for package: perl-perfSONAR_PS-SNMPMA
--> Processing Dependency: perl(MIME::Lite) for package: perl-perfSONAR_PS-SNMPMA
--> Processing Dependency: perl(IPC::Shareable) for package: perl-perfSONAR_PS-SNMPMA
--> Processing Dependency: perl(Mail::Sendmail) for package: perl-perfSONAR_PS-SNMPMA
--> Processing Dependency: rrdtool-perl for package: perl-perfSONAR_PS-SNMPMA
--> Processing Dependency: perl(Mail::Send) for package: perl-perfSONAR_PS-SNMPMA
--> Processing Dependency: perl(Mail::Sender) for package: perl-perfSONAR_PS-SNMPMA
--> Processing Dependency: perl(Email::Date::Format) for package: perl-perfSONAR_PS-SNMPMA
--> Processing Dependency: rrdtool for package: perl-perfSONAR_PS-SNMPMA
--> Processing Dependency: perl(XML::DOM) for package: perl-perfSONAR_PS-SNMPMA
--> Running transaction check
---> Package perl-Email-Date-Format.noarch 0:1.002-1.el5.rf set to be updated
---> Package perl-IPC-Shareable.noarch 0:0.60-2.el5.rf set to be updated
---> Package perl-MIME-Lite.noarch 0:3.025-1.el5.rf set to be updated
---> Package perl-Mail-Sender.noarch 0:0.8.16-1.el5.rf set to be updated
---> Package perl-Mail-Sendmail.noarch 0:0.79-1.2.el5.rf set to be updated
---> Package perl-MailTools.noarch 0:2.04-1.el5.rf set to be updated
---> Package perl-XML-DOM.noarch 0:1.44-2.el5.rf set to be updated
---> Package perl-XML-RegExp.noarch 0:0.03-1.2.el5.rf set to be updated
---> Package perl-rrdtool.i386 0:1.4.2-1.el5.rf set to be updated
---> Package rrdtool.i386 0:1.4.2-1.el5.rf set to be updated
--> Processing Dependency: ruby for package: rrdtool
--> Running transaction check
---> Package ruby.i386 0:1.8.5-5.el5_4.8 set to be updated
--> Processing Dependency: ruby-libs = 1.8.5-5.el5_4.8 for package: ruby
--> Processing Dependency: libruby.so.1.8 for package: ruby
--> Running transaction check
---> Package ruby-libs.i386 0:1.8.5-5.el5_4.8 set to be updated
--> Finished Dependency Resolution
Dependencies Resolved
====================================================================================================================================================
Package Arch Version Repository Size
====================================================================================================================================================
Installing:
perl-perfSONAR_PS-SNMPMA noarch 3.1-9.pSPS Internet2 130 k
Installing for dependencies:
perl-Email-Date-Format noarch 1.002-1.el5.rf rpmforge 16 k
perl-IPC-Shareable noarch 0.60-2.el5.rf rpmforge 39 k
perl-MIME-Lite noarch 3.025-1.el5.rf rpmforge 96 k
perl-Mail-Sender noarch 0.8.16-1.el5.rf rpmforge 55 k
perl-Mail-Sendmail noarch 0.79-1.2.el5.rf rpmforge 23 k
perl-MailTools noarch 2.04-1.el5.rf rpmforge 100 k
perl-XML-DOM noarch 1.44-2.el5.rf rpmforge 188 k
perl-XML-RegExp noarch 0.03-1.2.el5.rf rpmforge 8.0 k
perl-rrdtool i386 1.4.2-1.el5.rf rpmforge 52 k
rrdtool i386 1.4.2-1.el5.rf rpmforge 881 k
ruby i386 1.8.5-5.el5_4.8 rhel-i386-client-5 274 k
ruby-libs i386 1.8.5-5.el5_4.8 rhel-i386-client-5 1.6 M
Transaction Summary
====================================================================================================================================================
Install 13 Package(s)
Update 0 Package(s)
Remove 0 Package(s)
Total download size: 3.4 M
Is this ok [y/N]: y
Downloading Packages:
(1/13): perl-XML-RegExp-0.03-1.2.el5.rf.noarch.rpm | 8.0 kB 00:00
(2/13): perl-Email-Date-Format-1.002-1.el5.rf.noarch.rpm | 16 kB 00:00
(3/13): perl-Mail-Sendmail-0.79-1.2.el5.rf.noarch.rpm | 23 kB 00:00
(4/13): perl-IPC-Shareable-0.60-2.el5.rf.noarch.rpm | 39 kB 00:00
(5/13): perl-rrdtool-1.4.2-1.el5.rf.i386.rpm | 52 kB 00:00
(6/13): perl-Mail-Sender-0.8.16-1.el5.rf.noarch.rpm | 55 kB 00:00
(7/13): perl-MIME-Lite-3.025-1.el5.rf.noarch.rpm | 96 kB 00:00
(8/13): perl-MailTools-2.04-1.el5.rf.noarch.rpm | 100 kB 00:00
(9/13): perl-perfSONAR_PS-SNMPMA-3.1-9.pSPS.noarch.rpm | 130 kB 00:00
(10/13): perl-XML-DOM-1.44-2.el5.rf.noarch.rpm | 188 kB 00:00
(11/13): ruby-1.8.5-5.el5_4.8.i386.rpm | 274 kB 00:00
(12/13): rrdtool-1.4.2-1.el5.rf.i386.rpm | 881 kB 00:01
(13/13): ruby-libs-1.8.5-5.el5_4.8.i386.rpm | 1.6 MB 00:00
----------------------------------------------------------------------------------------------------------------------------------------------------
Total 441 kB/s | 3.4 MB 00:07
Running rpm_check_debug
Running Transaction Test
Finished Transaction Test
Transaction Test Succeeded
Running Transaction
Installing : ruby-libs 1/13
Installing : perl-MailTools 2/13
Installing : perl-Email-Date-Format 3/13
Installing : perl-XML-RegExp 4/13
Installing : perl-XML-DOM 5/13
Installing : perl-MIME-Lite 6/13
Installing : perl-IPC-Shareable 7/13
Installing : perl-Mail-Sendmail 8/13
Installing : perl-Mail-Sender 9/13
Installing : ruby 10/13
Installing : perl-rrdtool 11/13
Installing : rrdtool 12/13
Installing : perl-perfSONAR_PS-SNMPMA 13/13
Installed:
perl-perfSONAR_PS-SNMPMA.noarch 0:3.1-9.pSPS
Dependency Installed:
perl-Email-Date-Format.noarch 0:1.002-1.el5.rf perl-IPC-Shareable.noarch 0:0.60-2.el5.rf perl-MIME-Lite.noarch 0:3.025-1.el5.rf
perl-Mail-Sender.noarch 0:0.8.16-1.el5.rf perl-Mail-Sendmail.noarch 0:0.79-1.2.el5.rf perl-MailTools.noarch 0:2.04-1.el5.rf
perl-XML-DOM.noarch 0:1.44-2.el5.rf perl-XML-RegExp.noarch 0:0.03-1.2.el5.rf perl-rrdtool.i386 0:1.4.2-1.el5.rf
rrdtool.i386 0:1.4.2-1.el5.rf ruby.i386 0:1.8.5-5.el5_4.8 ruby-libs.i386 0:1.8.5-5.el5_4.8
Complete!