$ sudo yum install perl-perfSONAR_PS-perfAdmin
Password:
Loaded plugins: rhnplugin
Setting up Install Process
Resolving Dependencies
--> Running transaction check
---> Package perl-perfSONAR_PS-perfAdmin.noarch 0:3.1-6.pSPS set to be updated
--> Processing Dependency: perl(AnyEvent) >= 4.81 for package: perl-perfSONAR_PS-perfAdmin
--> Processing Dependency: perl(HTML::Template) for package: perl-perfSONAR_PS-perfAdmin
--> Processing Dependency: perl(AnyEvent::HTTP) for package: perl-perfSONAR_PS-perfAdmin
--> Processing Dependency: perl(Data::Validate::Domain) for package: perl-perfSONAR_PS-perfAdmin
--> Processing Dependency: perl(Net::CIDR) for package: perl-perfSONAR_PS-perfAdmin
--> Processing Dependency: perl(AnyEvent) for package: perl-perfSONAR_PS-perfAdmin
--> Running transaction check
---> Package perl-AnyEvent.noarch 0:5.240-1.el5.rf set to be updated
--> Processing Dependency: perl(JSON::XS) >= 2.2 for package: perl-AnyEvent
--> Processing Dependency: perl(JSON) >= 2.09 for package: perl-AnyEvent
--> Processing Dependency: perl(EV) >= 3.05 for package: perl-AnyEvent
--> Processing Dependency: perl(Guard) >= 1.02 for package: perl-AnyEvent
---> Package perl-AnyEvent-HTTP.noarch 0:1.44-1.el5.rf set to be updated
---> Package perl-Data-Validate-Domain.noarch 0:0.09-1.pSPS set to be updated
--> Processing Dependency: perl(Net::Domain::TLD) >= 1.62 for package: perl-Data-Validate-Domain
--> Processing Dependency: perl(Net::Domain::TLD) for package: perl-Data-Validate-Domain
---> Package perl-HTML-Template.noarch 0:2.9-1.el5.rf set to be updated
---> Package perl-Net-CIDR.noarch 0:0.13-1.pSPS set to be updated
--> Running transaction check
---> Package perl-EV.i386 0:3.9-1.el5.rf set to be updated
--> Processing Dependency: perl(common::sense) for package: perl-EV
---> Package perl-Guard.i386 0:1.021-1.el5.rf set to be updated
---> Package perl-JSON.noarch 0:2.17-1.el5.rf set to be updated
---> Package perl-JSON-XS.i386 0:2.27-1.el5.rf set to be updated
---> Package perl-Net-Domain-TLD.noarch 0:1.68-1.el5.rf set to be updated
--> Running transaction check
---> Package perl-common-sense.i386 0:3.0-1.el5.rf set to be updated
--> Finished Dependency Resolution
Dependencies Resolved
====================================================================================================
Package Arch Version Repository Size
====================================================================================================
Installing:
perl-perfSONAR_PS-perfAdmin noarch 3.1-6.pSPS Internet2 157 k
Installing for dependencies:
perl-AnyEvent noarch 5.240-1.el5.rf rpmforge 351 k
perl-AnyEvent-HTTP noarch 1.44-1.el5.rf rpmforge 26 k
perl-Data-Validate-Domain noarch 0.09-1.pSPS Internet2 15 k
perl-EV i386 3.9-1.el5.rf rpmforge 338 k
perl-Guard i386 1.021-1.el5.rf rpmforge 39 k
perl-HTML-Template noarch 2.9-1.el5.rf rpmforge 62 k
perl-JSON noarch 2.17-1.el5.rf rpmforge 93 k
perl-JSON-XS i386 2.27-1.el5.rf rpmforge 147 k
perl-Net-CIDR noarch 0.13-1.pSPS Internet2 17 k
perl-Net-Domain-TLD noarch 1.68-1.el5.rf rpmforge 20 k
perl-common-sense i386 3.0-1.el5.rf rpmforge 22 k
Transaction Summary
====================================================================================================
Install 12 Package(s)
Update 0 Package(s)
Remove 0 Package(s)
Total download size: 1.3 M
Is this ok [y/N]: y
Downloading Packages:
(1/12): perl-Data-Validate-Domain-0.09-1.pSPS.noarch.rpm | 15 kB 00:00
(2/12): perl-Net-CIDR-0.13-1.pSPS.noarch.rpm | 17 kB 00:00
(3/12): perl-Net-Domain-TLD-1.68-1.el5.rf.noarch.rpm | 20 kB 00:00
(4/12): perl-common-sense-3.0-1.el5.rf.i386.rpm | 22 kB 00:00
(5/12): perl-AnyEvent-HTTP-1.44-1.el5.rf.noarch.rpm | 26 kB 00:00
(6/12): perl-Guard-1.021-1.el5.rf.i386.rpm | 39 kB 00:00
(7/12): perl-HTML-Template-2.9-1.el5.rf.noarch.rpm | 62 kB 00:00
(8/12): perl-JSON-2.17-1.el5.rf.noarch.rpm | 93 kB 00:00
(9/12): perl-JSON-XS-2.27-1.el5.rf.i386.rpm | 147 kB 00:00
(10/12): perl-perfSONAR_PS-perfAdmin-3.1-6.pSPS.noarch.rpm | 157 kB 00:00
(11/12): perl-EV-3.9-1.el5.rf.i386.rpm | 338 kB 00:01
(12/12): perl-AnyEvent-5.240-1.el5.rf.noarch.rpm | 351 kB 00:00
----------------------------------------------------------------------------------------------------
Total 194 kB/s | 1.3 MB 00:06
Running rpm_check_debug
Running Transaction Test
Finished Transaction Test
Transaction Test Succeeded
Running Transaction
Installing : perl-common-sense 1/12
Installing : perl-EV 2/12
Installing : perl-JSON-XS 3/12
Installing : perl-JSON 4/12
Installing : perl-HTML-Template 5/12
Installing : perl-Net-Domain-TLD 6/12
Installing : perl-Data-Validate-Domain 7/12
Installing : perl-Net-CIDR 8/12
Installing : perl-Guard 9/12
Installing : perl-AnyEvent 10/12
Installing : perl-AnyEvent-HTTP 11/12
Installing : perl-perfSONAR_PS-perfAdmin 12/12
Stopping crond: [ OK ]
Starting crond: [ OK ]
Stopping httpd: [FAILED]
Starting httpd: [ OK ]
Installed:
perl-perfSONAR_PS-perfAdmin.noarch 0:3.1-6.pSPS
Dependency Installed:
perl-AnyEvent.noarch 0:5.240-1.el5.rf perl-AnyEvent-HTTP.noarch 0:1.44-1.el5.rf
perl-Data-Validate-Domain.noarch 0:0.09-1.pSPS perl-EV.i386 0:3.9-1.el5.rf
perl-Guard.i386 0:1.021-1.el5.rf perl-HTML-Template.noarch 0:2.9-1.el5.rf
perl-JSON.noarch 0:2.17-1.el5.rf perl-JSON-XS.i386 0:2.27-1.el5.rf
perl-Net-CIDR.noarch 0:0.13-1.pSPS perl-Net-Domain-TLD.noarch 0:1.68-1.el5.rf
perl-common-sense.i386 0:3.0-1.el5.rf
Complete!