Architecture=LINUX, commands=traceroute -q 1 and ping -s 1400 -c 50 -n realimage.realnet.co.sz pingroute.pl version=2.1, 1/28/10. Author cottrell@slac.stanford.edu, debug=1 using traceroute -q 1 realimage.realnet.co.sz to get nodes in route from pinger (134.79.104.80) to realimage.realnet.co.sz starting at node 1 pingroute.pl version 2.1, 1/28/10 found 20 hops in route from pinger to realimage.realnet.co.sz traceroute to realimage.realnet.co.sz (196.28.7.3), 30 hops max, 140 byte packets 1 rtr-servcore1-serv01-iepm.slac.stanford.edu (134.79.104.66) 0.457 ms 2 rtr-core2-p2p-servcore1.slac.stanford.edu (134.79.252.162) 0.365 ms 3 rtr-border2-p2p-core2.slac.stanford.edu (134.79.252.145) 0.601 ms 4 slac-mr2-p2p-rtr-border2.slac.stanford.edu (192.68.191.249) 0.292 ms 5 sunnsdn2-ip-slacmr2.es.net (134.55.217.2) 0.631 ms 6 sunncr1-sunnsdn2.es.net (134.55.209.98) 0.702 ms 7 eqxsjrt1-te-sunncr1.es.net (134.55.38.146) 1.147 ms 8 * 9 xe-3-0-0.par72.ip4.tinet.net (89.149.181.138) 154.429 ms 10 interoute-gw.ip4.tinet.net (77.67.75.238) 159.319 ms 11 ae0-0.par-gar-score-2-re0.interoute.net (212.23.42.26) 158.436 ms 12 84.233.162.170 (84.233.162.170) 176.390 ms 13 Gi9-1-0-170.mtz-201-access-3.mpls.seacomnet.com (41.217.213.22) 331.235 ms 14 Gi9-0-0.mtz-201-access-1.mpls.seacomnet.com (41.217.213.193) 330.152 ms 15 Gi4-3-107.mpm-201-access-1.mpls.seacomnet.com (41.217.213.218) 328.196 ms 16 41.87.97.70 (41.87.97.70) 331.856 ms 17 cust3750.swazi.net (69.63.64.69) 342.813 ms 18 69.63.69.102 (69.63.69.102) 342.104 ms 19 swt-core1-mb-vlan2.realnet.co.sz (41.204.3.1) 345.339 ms 20 realimage.realnet.co.sz (196.28.7.3) 1016.527 ms Wrote 21 addresses to /tmp/pingaddr, now ping each address 50 times from pinger starting at hop 1 pings/node=50 100 byte packets 1400 byte packets NODE %loss min max avg %loss min max avg dup from pinger 134.79.104.66 RTR-SERVCORE1-SERV01-IEPM.SLAC 0% 0.3 3.8 0.5 0% 0.6 2.2 0.8 0 Sat Mar 31 18:39:45 PDT 2012 134.79.252.162 RTR-CORE2-P2P-SERVCORE1.SLAC.S 0% 0.4 0.7 0.4 0% 0.7 5.0 0.9 0 Sat Mar 31 18:41:23 PDT 2012 134.79.252.145 RTR-BORDER2-P2P-CORE2.SLAC.STA 0% 0.0 0.0 0.0 0% 0.0 0.0 0.0 0 Sat Mar 31 18:43:02 PDT 2012 192.68.191.249 SLAC-MR2-P2P-RTR-BORDER2.SLAC. 0% 0.0 0.0 0.0 100% 0.0 0.0 0.0 0 Sat Mar 31 18:45:00 PDT 2012 134.55.217.2 SUNNSDN2-IP-SLACMR2.ES.NET 0% 0.8 58.2 4.4 0% 1.0 53.3 2.8 0 Sat Mar 31 18:46:58 PDT 2012 134.55.209.98 SUNNCR1-SUNNSDN2.ES.NET 0% 0.9 8.3 1.3 0% 1.5 7.5 1.7 0 Sat Mar 31 18:48:36 PDT 2012 134.55.38.146 EQXSJRT1-TE-SUNNCR1.ES.NET 0% 1.3 34.1 3.9 0% 1.5 33.9 3.3 0 Sat Mar 31 18:50:14 PDT 2012 89.149.181.138 XE-3-0-0.PAR72.IP4.TINET.NET 0% 154.3 189.1 157.3 0% 154.6 209.0 158.4 0 Sat Mar 31 18:51:52 PDT 2012 77.67.75.238 INTEROUTE-GW.IP4.TINET.NET 0% 159.0 196.3 164.0 0% 159.6 209.9 176.5 0 Sat Mar 31 18:53:31 PDT 2012 212.23.42.26 AE0-0.PAR-GAR-SCORE-2-RE0.INTE 0% 158.3 183.2 159.5 0% 158.5 171.8 159.4 0 Sat Mar 31 18:55:09 PDT 2012 84.233.162.170 84.233.162.170 0% 0.0 0.0 0.0 100% 0.0 0.0 0.0 0 Sat Mar 31 18:56:48 PDT 2012 41.217.213.22 GI9-1-0-170.MTZ-201-ACCESS-3.M 0% 320.2 321.7 320.6 0% 320.4 321.7 320.9 0 Sat Mar 31 18:58:46 PDT 2012 41.217.213.193 GI9-0-0.MTZ-201-ACCESS-1.MPLS. 0% 322.1 323.3 322.6 0% 322.5 323.7 323.0 0 Sat Mar 31 19:00:25 PDT 2012 41.217.213.218 GI4-3-107.MPM-201-ACCESS-1.MPL 0% 330.0 331.6 330.5 0% 330.3 331.7 330.8 0 Sat Mar 31 19:02:03 PDT 2012 41.87.97.70 41.87.97.70 0% 332.1 332.8 332.4 0% 332.8 421.9 334.7 0 Sat Mar 31 19:03:42 PDT 2012 69.63.64.69 CUST3750.SWAZI.NET 2% 342.9 581.0 348.4 0% 343.7 401.2 347.9 2 Sat Mar 31 19:05:21 PDT 2012 69.63.69.102 69.63.69.102 0% 337.6 412.6 349.5 0% 338.5 489.7 365.7 4 Sat Mar 31 19:07:01 PDT 2012 41.204.3.1 SWT-CORE1-MB-VLAN2.REALNET.CO. 0% 362.5 701.2 395.4 0% 364.6 406.8 367.0 0 Sat Mar 31 19:08:40 PDT 2012 196.28.7.3 REALIMAGE.REALNET.CO.SZ 2% 344.1 1079.3 901.2 96% 345.9 3998.7 2172.3 3 Sat Mar 31 19:10:20 PDT 2012