Data: thrulay,iperf,pathchirp

Duration: 01/01/06 00:00 - 31/08/06 23:59

Thrulay (all variables)

 Route

Plateau 

PCA 

Overlapping Events 

 SLAC-BINP

16 

 0

 SLAC-DESY

 9

 59

 1

 SLAC-NSLABS

 5

 0

 0

 SLAC-SDSC

 8

 0

 0

 SLAC-UTORONTO

 6

 9

 0

Correlation (tlaytcp)

 

tlay-pca

thrumin-pca

thrumax-pca

thrustd-pca

rtt-min-pca

rtt-avg-pca

rtt-max-pca

binp

0.016432984

0.070069789

0.005563301

0.005153154

-0.166163842

-0.160117599

-0.084480398

desy

0.305577299

0.064415068

0.403433028

0.422706907

-0.227071507

-0.369057521

-0.307497092

nslabs

0.112552426

-0.260517674

0.339543711

0.48301406

0.102165527

-0.092604664

0.20161899

sdsc

-0.293460283

-0.436878448

-0.080545761

0.670210333

0.039917806

0.094620517

0.275553869

utoronto

-0.050563763

-0.20087636

0.619479063

0.926270869

-0.002288811

0.022830679

0.068496875

Thrulay (all variables except Max RTT)

 Route

Plateau 

PCA 

Overlapping Events 

 SLAC-BINP

16 

 3

 0

 SLAC-DESY

 9

 60

 1

 SLAC-NSLABS

 5

 0

 0

 SLAC-SDSC

 8

 0

 0

 SLAC-UTORONTO

 6

 8

 0

Correlation (tlaytcp)

 

tlaytcp-pca

thrumin-pca

thrumax-pca

thrustd-pca

rtt-minp-pca

rtt-avg-pca

binp

0.019580794

0.088901835

0.006633359

0.005821846

-0.176175414

-0.170247855

desy

0.342419569

0.11976718

0.478498512

0.497779956

-0.242991558

-0.35877671

nslabs

0.132343952

-0.252496309

0.356502935

0.491780016

0.07382788

-0.118401707

sdsc

-0.312969911

-0.46078324

-0.098594683

0.688991435

0.042832191

0.081618934

utoronto

-0.067201544

-0.225957678

0.208824225

0.223352128

0.004889931

0.025509686

Thrulay (througput variables)

 Route

Plateau 

PCA 

Overlapping Events 

 SLAC-BINP

16 

 3

 0

 SLAC-DESY

 9

 27

 0

 SLAC-NASLABS 

 5

 0

 0

 SLAC-SDSC

 8

 0

 0

 SLAC-UTORONTO

 6

 7

 0

Correlation (tlaytcp)

 

tlaytcp-pca

thrumin-pca

thrumax-pca

thrustd-pca

binp

0.015842922

0.061763775

0.005966972

0.005750658

desy

0.378240782

0.155247626

0.493671351

0.499273767

nslabs

0.140624737

-0.24796054

0.364270575

0.498094835

sdsc

-0.313853113

-0.46146319

-0.099237207

0.689379947

utoronto

-0.067943634

-0.226900699

0.208679811

0.223339531

Thrulay (throughput variables except thrustd)

Route 

Plateau 

PCA 

Overlapping Events 

 SLAC-BINP

16 

 1

 0

 SLAC-DESY

 9

 767

 6

 SLAC-NSLABS

 5

 0

 0

 SLAC-SDSC

 8

 7

 0

 SLAC-UTORONTO

 6

 63

 2

Correlation (tlaytcp)

 

tlaytcp-pca

thrumin-pca

thrumax-pca

binp

0.034173446

0.047448355

0.02322458

desy

0.224949527

0.011058987

0.669522229

nslabs

0.237050664

-0.214812821

0.462218512

sdsc

-0.339324059

-0.501956225

-0.120055265

utoronto

-0.349791164

-0.579165076

0.103919611

Pathchirp (all variables)

 Route

Plateau 

PCA 

Overlapping Events 

 SLAC-BINP

 4

 0

 0

 SLAC-BNL

 4

 0

 0

 SLAC-TWAREN

 0

 20

 0

 SLAC-CALTECH

 2

 0

 0

 SLAC-UTORONTO

 4

 0

 0

 SLAC-SDSC

 0

 0

 0

Correlation

 

pathchirp

thru-min

thru-max

thru-std

binp

0.304552926

0.128924105

0.479074811

0.468488297

nl

0.158065689

0.040177254

0.25680967

0.330190135

twaren

0.319012894

0.255514685

0.37073895

0.393167609

toronto

0.224485492

0.171602772

0.285942436

0.372971396

sdsc

0.039077144

0.002372192

0.112468635

0.140539695

caltech

0.055842567

-0.02261612

0.156277482

0.286108454

Iperf (all variables)

 Route

Plateau 

PCA 

Overlapping Events 

 SLAC-TORONTO

 0

 12

 0

 SLAC-BNL

 2

 2

 0

 SLAC-SDSC

 1

 3

 1

Correlation

 

iperf

thrumin

thruavg

thrumax

thrustd

toronto

-0.427806824

-0.450819125

-0.411932061

-0.093317707

0.194256265

bnl

0.1858894

0.121985181

0.195214768

0.252765833

0.344864322

sdsc

-0.298230102

-0.419956841

-0.214180978

-0.092055046

0.022387166

  • No labels