When working only in the laser room
- Block beam with foam at the output of the Main-amp and insert power meter, remove foam.
- Turn off the SAGAs by clicking Stop on both control computers (this will also close the shutters).
- Turn off the Pre-amp pump laser by pushing both the Flashlamp button on the remote (will also turn off the Q-switch).
When working in the tunnel
- Block the laser with the transport shutter (Laser Room Control Panel→Transport Shutter).
- Turn the LSS key to off to close shutters T1 and T2.
- Block beam with foam at the output of the Main-amp and insert power meter, remove foam.
- Turn off the SAGAs by clicking Stop on both control computers (this will also close the shutters).
- Turn off the Pre-amp pump laser by pushing both the Flashlamp button on the remote (will also turn off the Q-switch).