The main laser can be attenuated with a waveplate just after the RP attenuator. To adjust the angle go to FACETHOME→Laser→LI20→Infrastructure→XPS moc-la20-ls24, channel 1.

Minimum energy corresponds to a waveplate angle of 74deg, maximum energy to an angle of 119deg.


The output energy of the attenuator as a function of waveplate angle was measured on 6/22/2022 as:

Transmitted Energy

(Relative to max)

Waveplate AngleNotes

1%

76.4
1.4%76.9Equivalent to RP attenuator
5%79.9
10%82.6
20%86.6
30%90
40%93
50%95.5
60%98.5
70%101.5
80%105
90%109
100%118.39