1. Transition to RF off is accomplished with a single sequenced button: “RF Off
  • Open A&P feedback loop
  • Stop following PRL
  • Start tracking cavity frequency
  • Go to pulsed mode by changing duty cycle to 99.85%
  • Turn RF OFF
  • Set cavity tuners to force mode