Code Versions
Engineering Model (sim/recon): v6r070329p11
System Tests for this version
System Tests results:
Differences in vdg_oneTower test due to changes in source location. Changes in VerticalGamma100MeV due to ACD veto change from 0.1 MIP to 0.3 MIP.
Fred version:
Pipeline version:
v1.4.2
GRITS tag (web browsing and task configuration)
glast-ground v0r3p7
grits-gino-web version 0.55 (v0r5p5)
grits-gino version 0.95 (v0r9p5)
grits-gino-xml version 1.42 (v1r4p2)
grits-common version 0.32 (v0r3p2)
online/svac (task defs, scripts):
pipeline tasks:
online: v2r4p1
svac pipeline code and tasks:
code/tasks v3r5p7:
pipelineDatasets v0r3
ISOC code and tasks:
v0r5p0
Apps that run in pipeline:
eLog: v2r3p1
ConfigTables: v3r2p1
TestReport: v3r5p6 (digi & recon reports):
- Added ACD electronics space and ACD trigger quantities. Also improved descriptions.
- Protect against time hacks being the same in two events.
- Get GEM discarded counter from context information. Drop rollover protection.
- Added number of prescaled and dead zone events.
- Added check on the consistency between the GEM sequence counter and the number of events in the digi file.
- Added more context/time tone information.
- Added trigger/deadzone/discarded rates for 30 time intervals. In case of problems it may tell us where in a run it happened and speed up troubleshooting.
- Added consistency check on extended counters.
EngineeringModelRoot: v1r18 (SVAC tuple)
- Added a few useful AcdMips variables (sum and max and error flag).
- Updated documention.
Approved: