The skimming tool has been generalized and externalized. The last releases of source code, documentation and pending issues are now available at the new TRAC server. The tutorial below is still valuable, because the recent TSkim releases are still compatible with those old variables. Yet, it is strongly recomended to move to the new interface, described here, here and there. An upgrade of this tutorial is under work.
Date: 24 June 2008
Software by: David Chamont
Presentation by: Tom Glanzman
Update: 16 July 2008
This is intended to be a quick start guide for using the current skimmer version (v6r0p1) to extract merit/digi/recon events from real data as well as construct event lists. Event lists (text file with "Run EventId" pairs) may be used to drive the WIRED event display. FRED (i.e. Gleam) needs the explicit digi and recon files to read.
Two simple cases will be illustrated:
Note that at some point the web interface to the skimmer will be able to handle these functions so this is but a stop-gap measure until the web interface is ready.
There is much more the skimmer can do but this guide does not (yet) cover any of that functionality.
/nfs/farm/g/glast/u18/skimmerTest/
Given this script and this filelist, the following files result:
$ ./treeCut.csh [lots of output...] $ ls -l -rw-rw-r-- 1 dragon glast-pipeline 727 Jun 24 14:00 newfilelist.txt -rw-rw-r-- 1 dragon glast-pipeline 881 Jun 24 14:00 libraryList.txt -rw-rw-r-- 1 dragon glast-pipeline 15666 Jun 24 14:00 v14r4-BranchList.txt -rw-rw-r-- 1 dragon glast-pipeline 1787 Jun 24 14:00 eventList.txt -rw-r--r-- 1 dragon glast-pipeline 122406 Jun 24 14:00 L1PROC-skim_merit.root -rw-r--r-- 1 dragon glast-pipeline 873903 Jun 24 14:00 L1PROC-skim_recon.root -rw-r--r-- 1 dragon glast-pipeline 182663 Jun 24 14:00 L1PROC-skim_digi.root
These root files contain 119 events.
Given this script, this filelist and this eventlist, the following files result:
$ ./treeEvtList.csh [lots of output...] $ ls -l -rw-rw-r-- 1 dragon glast-pipeline 727 Jun 24 14:04 newfilelist.txt -rw-rw-r-- 1 dragon glast-pipeline 881 Jun 24 14:04 libraryList.txt -rw-rw-r-- 1 dragon glast-pipeline 15666 Jun 24 14:04 v14r4-BranchList.txt -rw-r--r-- 1 dragon glast-pipeline 51023 Jun 24 14:04 L1PROC-skim_merit.root -rw-r--r-- 1 dragon glast-pipeline 194381 Jun 24 14:04 L1PROC-skim_recon.root -rw-r--r-- 1 dragon glast-pipeline 123064 Jun 24 14:04 L1PROC-skim_digi.root
These root files contain 21 events.
/afs/slac/g/glast/ground/DataServer/
Various skimmer-related problems have been reported over the past few weeks. Below are some general hints to using the skimmer followed by descriptions of a couple of outstanding problems.
For noric machines:
setenv TMP /usr/work/<your-userid> setenv TMPDIR /usr/work/<your-userid>
For batch machines:
setenv TMP /scratch/<your-userid> setenv TMPDIR /scratch/<your-userid>
Note that if you are running multiple skimmer jobs on the same machine, you will be obligated to define unique $TMP and $TMPDIR spaces for each job.