Report by Gino Tosti (prepared September 13, 2005)
1-Science Tools v6r0p2 succesfully installed using GlastInstaller 1.3 on windows XP
2-I ran the following "test_xxx" programs and this is a sinthetic report:
test_astro OK test_burstFit OK test_celestialSources OK test_dataSubselector OK test_evtbin Error: -->This is test_evtbin version v1r12p2 Expected: failed to create a BinConfig before prototypes were loaded: BinConfig::create was unable to find a configuration for mission "GLAST", instrument "LAT" while processing file "C:\Documents and settings\gino\Glast\ScienceTools-v6r0p2 /evtbin/v1r12p2\data\ft1tiny.fits" test_fitsGen.vbs Error:'C:\Documents' is not recognized as an internal or external command,operable program or batch file. test_flux OK test_IFile Error--> too long to be reported test_hoops OK test_likelihood OK test_map_tools OK test_mem OK test_observationSim OK test_optimizers OK test_periodSearch.vbs OK test_pulsarDb.vbs OK test_pulsePhase.vbs OK test_rspgen.vbs OK test_sane.vbs Error: NTVDM CPU has encountered an illegal instruction test_st_app OK test_st_graph OK test_st_facilities OK test_st_stream. OK test_st_stream OK test_time OK test_tuple Error: Error in <TBuffer::CheckByteCount>: object of class TNamed read too few bytes: 26 instead of 3034063 Opened ROOT file "C:\Documents and Settings\gino\Glast\ScienceTools-v6r0p2/tuple /v1r3/src/test/DC1_galcenter.root" tree "" Exception: branch "FT1Ra" not found test_Util OK test_xmlBase OK
3- For the other program in the directory "bin" I obteined:
like_gui Error: NTVDM CPU has encountered an illegal instruction likeGui Error: NTVDM CPU has encountered an illegal instruction makeFT1 OK makeFT2 OK makeFT2a OK ModelEditor Error: NTVDM CPU has encountered an illegal instruction ObsSim Error: NTVDM CPU has encountered an illegal instruction rootplots OK sane Error: NTVDM CPU has encountered an illegal instruction exposure_cube Error:This is exposure_cube version N/A Creating an exposure object from a pointing history file .../common/DC2/history/ Gleam42.txt Opening text format pointing history file /common/DC2/history/Gleam42.txt ERROR: Unable to open: /common/DC2/history/Gleam42.txt
4- Light curve of Blazar J0118p0248 ---RA = 19.6; DEC = 2.81; z=0.63
C:\>gtselect Input FT1 file [test_events_0000.fits] : C:\Documents and Settings\gino\Glast\ch eckout3data\L0509131400237B05FD7258_PH00.fits Output FT1 file [filtered_events_0000.fits] : blaz1_lc.fits RA for new search center (degrees) <0 - 360> [86.4] : 19.6 Dec for new search center (degrees) <-90 - 90> [28.9] : 2.82 radius of new search region (degrees) <0 - 180> [20] : 5 start time (MET in s) [0] : end time (MET in s) [0] : 100000000 lower energy limit (MeV) [30] : 20 upper energy limit (MeV) [200000] : 300000 Done. C:\>gtbin This is gtbin version v1r12p2 Type of output file <CMAP|LC|PHA1|PHA2> [PHA2] : cmap Caught class hoops::PILException at the top level: Could not write file name par ameter evfile for component gtbin (at \Glast_Software\Toaster\builds\VC8debug\Sc ienceTools\ScienceTools-v6r0p2\hoops\v0r4p4\src\hoops_pil.cxx: 252) C:\Documents and Settings\gino\Glast\ScienceTools-v6r0p2\bin>