Dashboard > Flight Integration svac-SAS CCB > Browse Space > News from
  Flight Integration svac-SAS CCB Log In View a printable version of the current page.  
  News from August, 2005
  2005/08/03
Last changed: Aug 05, 2005 08:48 by Richard Dubois

svac changes

svacPipeline V3r2p0:
--------------------
Parallel recon (http://jira.slac.stanford.edu/browse/SVAC-38 and http://jira.slac.stanford.edu/browse/SVAC-68)
Run digiReport on xlong (http://jira.slac.stanford.edu/browse/SVAC-66)
Recon EM hardware without calibrations (http://jira.slac.stanford.edu/browse/SVAC-64)

eLog v2r2p7:
------------
Deal with multi-digit bay numbers (http://jira.slac.stanford.edu/browse/SVAC-65)

onlinePipeline v2r3p0:
--------------------
Support >2G FITS file writing (http://jira.slac.stanford.edu/browse/PIT-12)
Support >8G TAR file writing (http://jira.slac.stanford.edu/browse/PIT-14)

Code Versions

Engineering Model (sim/recon) v5r0608p1

System Tests for this version

System Tests Result

FRED version

0.98

Pipeline tag

v1r0p2

GRITS tag (web browsing and task configuration)

glast-ground v0r3p7
grits-gino-web version 0.55 (v0r5p5)
grits-gino version 0.95 (v0r9p5)
grits-gino-xml version 1.42 (v1r4p2)
grits-common version 0.32 (v0r3p2)

online/svac (task defs, scripts):

pipeline tasks:

online: v2r3p0

svac pipeline code and tasks:

code/tasks v3r2p0 **changed**

ISOC code and tasks:

v0r5p0

Apps that run in pipeline:

eLog: v2r2p7 **changed**
ConfigTables: v3r1p4
TestReport: v3r2p7 (digi & recon reports)
EngineeringModelRoot: v1r3p19(SVAC tuple)

Approval: 04 Aug unanimous

Posted at 03 Aug @ 5:10 PM by Richard Dubois | 0 comments
  2005/08/09


Dan upgraded the PROD pipeline to incorporate Navid's batch interface. This was tested out with bulk MC in the test db, and all major tasks have been tried in prod now and work.

Posted at 09 Aug @ 9:40 AM by Richard Dubois | 0 comments
Last changed: Aug 14, 2005 07:57 by Richard Dubois

EngineeringModel v5r0608p6

RootIo v15r8p1em6: Remove memory leak/overwrite - 'Reset TProcessID ObjectNumber in RootIoSvc rather than in mcRootWriter. Put in fix to clear commonData maps in RootIoSvc'

ldfConverter v1r15: Add two JO to be able to be able to jump directly to a specific event in a Fits file.

xmlGeoDbs v1r22p7
Leon Rochester and Anders Borgland
Address JIRA http://jira.slac.stanford.edu/browse/GEO-6
Add support for 10, 12, 14 towers and 8 tower plus ACD configurations.

GlastSvc v9r13p1
Leon Rochester
Addresses JIRA http://jira.slac.stanford.edu/browse/GEO-5, where non-zero alignment constants sometimes caused non-physical strip numbers to be generated.

RootIo v15r8p1em4
Heather Kelly
Minor fix (one line) for windows, add explicit return of Gaudi StatusCode. Also modifies the default file split size from 25 GB to 500 GB.

CalXtalResponse v0r6p6
Zach Fewtrell
Fixed bug in mixed diode XtalDigi that had bad position estimates for diode deposit hits (CsI hits were fine).
Fixed a minor bug in recent CalTuple code (bad var init). The bad code was so young that it never made it into a tagged EM or GR release, so net bugfixes for EM & GR tags is just 1.
RECALIBRATION: ideal mode flight noise & LAC thresholds have been updated to better approximate expected flight noise levels.

TkrUtil v3r4p1
Leon Rochester
Fix for JIRA http://jira.slac.stanford.edu/browse/TKR-17
The default nominal constants have been adjusted to match the average for Tkr A and B. The constant fCPerMip has been changed to 5.0, to match the value used by Hiro in generating the ToT constants. The constant MeVPerMip has been changed from 0.155 to 0.113. Was using the mean energy, but should have been using the most probable value.

calibGenTKR v2r6p2
Hiro Tajima

Fix row and col definition of tower. Add several plots to monitor
tot fit parameters.

ldfReader v2r4p2
Heather Kelly
Fix for JIRA http://jira.slac.stanford.edu/browse/ROOT-15, where the log messages contained only the 17 bit event sequence rather than the new 32 bit event number.

LdfConverter v1r14
Heather Kelly
In response to JIRA http://jira.slac.stanford.edu/browse/LDF-25, adds a check to LdfCalDigiCnv for all four readouts in ALLRANGE mode.

HepRepCorba v1r6
Riccardo Giannitrapani
Addresses JIRA http://jira.slac.stanford.edu/browse/FRED-40

calibUtil v1r5p1
Joanne Bogart

Addresses JIRA http://jira.slac.stanford.edu/browse/CALIB-15. Lay groundwork for insert-latest and
supersede functions in rdbGUI.

rdbModel v2r2p2
Joanne Bogart

Addresses JIRA http://jira.slac.stanford.edu/browse/CALIB-15. Lay groundwork for insert-latest and
supersede functions in rdbGUI.

RootIo v15r8p1em4
Heather Kelly
Minor patch (change one constant) to modify the default file split size from 25 GB to 500 GB as requested by I&T.

calibGenCAL v3r7p2
Zach Fewtrell

ciFit & runMuTrigEff will now accept CI files w/ any multiple of
nXtalsPerTower hits per event. i.e. they accept parallel
calibrations. Also runMuTrigEff will intelligently skip the 'scan
events' which are sometimes intersperved w/ data events, & can
slightly mess up the event numbering & binning
runSuiteParallel script added which runs ciFit, muonCalib, muTrig,
***Merge.py, ***Validate.py on a full set of parallel calibration
data. Also the C++ applications now expand more environment
variables in the config options file in order to support the
runSuiteParallel script.

LatIntegration v2r33
Anders Borgland
Contains new system tests (4,6 tower data + all_gamma MC)
Include writing CAL ntuple as the default in the jobOptions files.
Reduce TKR noise in jobOptions file for Monte Carlo runs, addresses JIRA http://jira.slac.stanford.edu/browse/TKR-18.

svac updates

svacPipeline v3r3p0:

Add CAL tuple as ouput from recon (SVAC-69) run digitization on xlong (http://jira.slac.stanford.edu/browse/SVAC-70)

pipelineDatasets v0r3:

increase max tree size to 500 GB (http://jira.slac.stanford.edu/browse/SVAC-71)

Code Versions

Engineering Model (sim/recon)v5r0608p6 **changed**

System Tests for this version

System Tests Result

System tests:

I have checked all system tests histograms for EM p3 wrt EM p1.
Two changes were seen for MC. One is under investigation by Leon
(increased active area in the geometry increases unexpectedly the number
of MC hits), the other was due to a change in the ideal flight mode and
affected only one one MC system test that do not use calibrations.

There were no differences in system tests histograms between p4
and p3.

There were some differences in two MC system tests between p5 and
p4 because of new CAL calibration constants I put in yesterday in
preparation of datataking.

There were no differences in system tests histograms between p6
and p5. Note that I have added 4 and 6 tower data and 6 tower allgamma
system tests as of p6. They are currently not available for viewing -
there is a JIRA out on it from Julie.

anders

FRED version

0.98

Pipeline tag

v1r0p2

GRITS tag (web browsing and task configuration)

glast-ground v0r3p7
grits-gino-web version 0.55 (v0r5p5)
grits-gino version 0.95 (v0r9p5)
grits-gino-xml version 1.42 (v1r4p2)
grits-common version 0.32 (v0r3p2)

online/svac (task defs, scripts):

pipeline tasks:

online: v2r3p0

svac pipeline code and tasks:

code/tasks v3r3p0 **changed**
pipelineDatasets v0r3 **new**

ISOC code and tasks:

v0r5p0

Apps that run in pipeline:

eLog: v2r2p7
ConfigTables: v3r1p4
TestReport: v3r2p7 (digi & recon reports)
EngineeringModelRoot: v1r3p19(SVAC tuple)

Approval: unanimous 13 Aug 2005

Posted at 09 Aug @ 6:56 PM by Richard Dubois | 0 comments
  2005/08/18

svac updates

svacPipeline v3r3p1:
Use glastdata SLF group for chunk jobs in parallel recon.
Increase chunk size for parallel recon.
Add more logging to recon.

ConfigTables v3r1p5:
Don't crash on runs with no TEMs.

EngineeringModelRoot v1r3p20

Sets the maximum Root file size to 500 GB instead of 1.8 GB.

Will see how 8 tower data taking goes. If we hit the file size limit we would need to add this tag before reprocessing.

Code Versions

Engineering Model (sim/recon)v5r0608p6

System Tests for this version

System Tests Result

System tests:

I have checked all system tests histograms for EM p3 wrt EM p1.
Two changes were seen for MC. One is under investigation by Leon
(increased active area in the geometry increases unexpectedly the number
of MC hits), the other was due to a change in the ideal flight mode and
affected only one one MC system test that do not use calibrations.

There were no differences in system tests histograms between p4
and p3.

There were some differences in two MC system tests between p5 and
p4 because of new CAL calibration constants I put in yesterday in
preparation of datataking.

There were no differences in system tests histograms between p6
and p5. Note that I have added 4 and 6 tower data and 6 tower allgamma
system tests as of p6. They are currently not available for viewing -
there is a JIRA out on it from Julie.

anders

FRED version

0.98

Pipeline tag

v1r0p2

GRITS tag (web browsing and task configuration)

glast-ground v0r3p7
grits-gino-web version 0.55 (v0r5p5)
grits-gino version 0.95 (v0r9p5)
grits-gino-xml version 1.42 (v1r4p2)
grits-common version 0.32 (v0r3p2)

online/svac (task defs, scripts):

pipeline tasks:

online: v2r3p0

svac pipeline code and tasks:

code/tasks v3r3p1 **changed**
pipelineDatasets v0r3

ISOC code and tasks:

v0r5p0

Apps that run in pipeline:

eLog: v2r2p7
ConfigTables: v3r1p5 **changed**
TestReport: v3r2p7 (digi & recon reports)
EngineeringModelRoot: v1r3p20(SVAC tuple) **changed**

Approval: Richard 18 Aug 2005 (everyone else absent!)

Posted at 18 Aug @ 5:19 PM by Richard Dubois | 0 comments

August 2005
Sun Mon Tue Wed Thu Fri Sat
  1 2 3 4 5 6
7 8 9 10 11 12 13
14 15 16 17 18 19 20
21 22 23 24 25 26 27
28 29 30 31      

Aug 09, 2005
Aug 09, 2005

Powered by Atlassian Confluence, the Enterprise Wiki. (Version: 2.5.8 Build:#814 Oct 02, 2007) - Bug/feature request - Contact Administrators