Dashboard > AntiCoincidence Detector > ... > Bug Investigations > ACD Leak May, 2006
  AntiCoincidence Detector Log In View a printable version of the current page.  
  ACD Leak May, 2006
Added by Heather Arrighi, last edited by Heather Arrighi on May 23, 2006  (view change)
Labels: 
(None)

GR v9r4 included a number of modifications to AcdDigi, AcdUtil and AcdRecon in response to the curved tiles.

(Run, Event): (7, 110985)
 Act_Dist: 72
OBJ: AcdId      AcdId   ACD Tile identification information
Id: 202
  ( Face, Row, Column): (2, 0, 2)

In merit - the 3D active distance is populated as it is in recon.root.  The AcdActDistTileEnergy is zero as reported by Bill. 

************************************************************
*    Row   *    EvtRun * EvtEventI * AcdActive * AcdActDis *
************************************************************
*     3565 *         7 *    110985 * 72.337997 *         0 *
************************************************************
==> 1 selected entry

 

(Run, Event): (19, 76327)
 Act_Dist: 1.1e+002
OBJ: AcdId      AcdId   ACD Tile identification information
Id: 103
  ( Face, Row, Column): (1, 0, 3)

 

(Run, Event): (509, 9393)
 Act_Dist: 27
OBJ: AcdId      AcdId   ACD Tile identification information
Id: 43
  ( Face, Row, Column): (0, 4, 3)

 

(Run, Event): (663, 41876)
 Act_Dist: 61
OBJ: AcdId      AcdId   ACD Tile identification information
Id: 303
  ( Face, Row, Column): (3, 0, 3)

 

(Run, Event): (980, 9278)
 Act_Dist: -0.42
OBJ: AcdId      AcdId   ACD Tile identification information
Id: 43
  ( Face, Row, Column): (0, 4, 3)

(Run, Event): (990, 27808)
 Act_Dist: -2.2e+002
OBJ: AcdId      AcdId   ACD Tile identification information
Id: 230
  ( Face, Row, Column): (2, 3, 0)

 

(Run, Event): (1127, 30636)
 Act_Dist: -0.54
OBJ: AcdId      AcdId   ACD Tile identification information
Id: 201
  ( Face, Row, Column): (2, 0, 1)

 

(Run, Event): (1141, 7536)
 Act_Dist: 34
OBJ: AcdId      AcdId   ACD Tile identification information
Id: 113
  ( Face, Row, Column): (1, 1, 3)

 

(Run, Event): (1488, 122747)
 Act_Dist: -6.2e+002
OBJ: AcdId      AcdId   ACD Tile identification information
Id: 130
  ( Face, Row, Column): (1, 3, 0)

 

(Run, Event): (1677, 76916)
 Act_Dist: 90
OBJ: AcdId      AcdId   ACD Tile identification information
Id: 21
  ( Face, Row, Column): (0, 2, 1)

 

(Run, Event): (1762, 2114)
 Act_Dist: -30
OBJ: AcdId      AcdId   ACD Tile identification information
Id: 40
  ( Face, Row, Column): (0, 4, 0)

 

(Run, Event): (1820, 41363)
 Act_Dist: 1.1e+002
OBJ: AcdId      AcdId   ACD Tile identification information
Id: 203
  ( Face, Row, Column): (2, 0, 3)

 

(Run, Event): (1910, 7070)
 Act_Dist: -2.8e+002
OBJ: AcdId      AcdId   ACD Tile identification information
Id: 430
  ( Face, Row, Column): (4, 3, 0)

 

(Run, Event): (1948, 7722)
 Act_Dist: 72
OBJ: AcdId      AcdId   ACD Tile identification information
Id: 200
  ( Face, Row, Column): (2, 0, 0)

 

 

 

 

Powered by Atlassian Confluence, the Enterprise Wiki. (Version: 2.5.8 Build:#814 Oct 02, 2007) - Bug/feature request - Contact Administrators