Two power supplies crates are being used to power the top and bottom volumes of the Silicon VertexTracker (SVT).
To connect to their interfaces, first login into clon10 from a JLab machine with the user name clasrun:
> ssh clasrun@clon10
In order to obtain the password, talk to an expert!
At this point, the EPICS GUI is started as follows:
> medm -x /usr/local/clas/devel/R3.14.12/support/xycomioc-1.0/medm/svt_trips.adl
The Bias current is very small and will show up as 0.
In the case where the operation of the power supplies can not be done through EPICS, each power supply can be accessed directly through a terminal. After login into clon10 (see above), the command
> tsconnect hpshv1
will bring up the display for the power supply powering the top SVT volume and
> tsconnect hpshv2
will bring up the display for the power supply powering the bottom volume. After each of the terminal interfaces come up, hitting N (next) will refresh the window. It will also allow you to navigate between screens
The following table provides a map from a power supply channel # to a physical location on the SVT: