General notes:
- For all scans: add all scalar lists to the dataset
Recover Laser on MO_MAG
- Move RP attenuator out, ND filters in
- Recover M1/M2 alignment using FrontView
- Verify that laser is back on MO
- First focal scan to verify laser quality
Recover EOS
- Prepare EOS: first polarizer: full transmission; camera/analyzing polarizer: maximum extinction
- EOS timing scan to find t0 for EOS:
Spatial Alignment: KES
- Align vertical: 1 micron steps, over 100 micron, 10 per step (1000 shots ~< 2 minutes); record both MO_MAG and GAMMA1
Align horizontal:
Timing YAG
- Find t0 using a) long-range scan b) fine scan (10fs-steps)
- Move EOS delay stage to see EOS and YAG timing simultaneously
- long scan (YAG + EOS): 5ps window around t0, 10fs steps, 5 per step (2500 shots ~< 5 minutes); MO_MAG + EOS
- fine scan (YAG + EOS): 100fs window around t0, 1fs steps, 25 per step (2500 shots ~< 5 minutes); MO_MAG + EOS
- jitter scan (YAG + EOS): keep timing at t0, take 2500 shots at the same position; MO_MAG + EOS