The mcdrcal00 detector model:
Properties of the calorimeter which is realized as a dual readout optical calorimeter and muon system:
|
electromagnetic section |
hadronic section |
muon system |
||
material |
BGO (PbF2) |
BGO (PbF2) |
Iron |
||
<ac:structured-macro ac:name="unmigrated-wiki-markup" ac:schema-version="1" ac:macro-id="b0cd994b-011d-42b2-b09b-6a724e9ff618"><ac:plain-text-body><![CDATA[ |
density [ g/cm3 ] |
7.13 (7.77) |
7.13 (7.77) |
7.85 |
]]></ac:plain-text-body></ac:structured-macro> |
<ac:structured-macro ac:name="unmigrated-wiki-markup" ac:schema-version="1" ac:macro-id="5e50d572-d835-422b-a688-bd273f6c611a"><ac:plain-text-body><![CDATA[ |
Cell size [ cm ] |
1x1x2 |
2x2x5 |
10x10x10 |
]]></ac:plain-text-body></ac:structured-macro> |
Layers |
10 |
30 |
22 |
||
<ac:structured-macro ac:name="unmigrated-wiki-markup" ac:schema-version="1" ac:macro-id="f9eaefd6-6b26-4e10-b6f1-133046ce2733"><ac:plain-text-body><![CDATA[ |
Detector Depth [cm] |
20 |
150 |
220 |
]]></ac:plain-text-body></ac:structured-macro> |
<ac:structured-macro ac:name="unmigrated-wiki-markup" ac:schema-version="1" ac:macro-id="213e6f2b-b505-4775-b706-dbdfe2d7397d"><ac:plain-text-body><![CDATA[ |
Radiation Length [cm] |
1.1 (0.93) |
1.1 (0.93) |
1.76 |
]]></ac:plain-text-body></ac:structured-macro> |
<ac:structured-macro ac:name="unmigrated-wiki-markup" ac:schema-version="1" ac:macro-id="cbaa5f2a-19cd-48c2-ad8e-7f65ef6fd2d3"><ac:plain-text-body><![CDATA[ |
IA length [cm] |
22.7 (22.4) |
22.7 (22.4) |
16.8 |
]]></ac:plain-text-body></ac:structured-macro> |
Total Nr of IA length (em+had) |
7.5 (7.6) |