,These are data files that are publicly available using DataSource('exp=EXPNAME:run=NNN'), where NNN can be found in the first column below, and EXPNAME is xpptut15 for the first table below, and cxitut13 for the second table below.
xpptut15 starting run number | Data origin | Comments |
---|---|---|
54,59 | XPP test DAQ Runs | 59 contains epics |
101,102,124 | cxii0314 | xtcav: 101: lasing off, 102: dark, 124: lasing on |
140 | xppi0813 75-85,87 | 87 is dark |
160 | xppc0114 287 | |
170 | xppc0115 270 | |
180 | xppf2115 | 189,190,192, detector is cs140k, data are "samr" scans. |
190 | xpp72213 324,300 | detector is cs140k, data are most likely delay scans. |
200 | xppd0115 375,366 | 366 is dark, 375 is delay scan, detector is a 140k. |
210 | xppi3815 224,225 | ccmE_vernier scan, detector is a diode on the end station IPM (diodeU), channel3. A 140k is used for the spectrometer. |
220 | xppi3815 100-104 | delay scans. |
230 | xpph4915 17 | |
240 | xppc0115 328,335 | 328 is rayonix with 2x2 binning, 335 has 10x10 |
250 | xpp02016 225,272,300 | New delay scan implementation |
260 | xcs01116 81,82,83,120 | EPIX: 81(dark), 82,83(vonHamos), 120(speckle) |
270 | cxi06216 22 | crystallography run |
280 | amoi0216 32,34, | (from Timur Osipov) if I remember it correctly there were two acqires boards (1 and 2?) one broken into 4 channels and the second one just one (or two) channel. The one with 4 channels would be the coordinates for the square delay-line (0 - x1, 1 - x2, 2 - y1, 3 - y2), the other one, with the fewer channels, should be the MCP - TOF channel for the delay line. As for the phosphor screen detector the files from the commissioning of the LAMP (amoc0113) should work - runs 217, 219, 220 each is a couple minutes long with opal images of the phosphor detector. |
290 | amoc0113 217,219 | see run 280 notes |
300 | diamcc14 920,921,922 | xtcav: dark,lasing-off,lasing-on xtcav. s00 renamed to s80 |
310 | amol9416 272 | long gain 6 dark for front pnCCD |
320 | xppl4416 283,284 | XPP cspad data and shows powder rings. LaB6 is the sample. |
330 | sxr82112 197 | Practice encoder data for determining pump-probe time (but no extra time-tool information) |
340 | amo06516 10,15,19 | pnccd flat-field data (1.74 keV photons from Si k-alpha) |
See ~cpo/ipsana/xpptut15_copy.py for a script to copy runs into /reg/d/psdm/xpp/xpptut15/, which automatically updates the run number in the filename and for the xtc begin-run transition. It also attempts to copy over relevant calibration constants.
cxitut13 run number | Data origin | Comments |
---|---|---|
10 | cxi06216 22 | lysozyme crystallography tutorial data |
11 | cxi06216 17 | dark data for the above |
20 | cxi00516 6 | 8keV flat-field data on DsaCsPad |
30 | cxi12016 24 | Diode wire scan with Imp detector |