MCC Board ID |
MCC CHIP |
Location |
---|---|---|
18019195 |
25/27 |
CERN |
18019196 |
25/26 |
CERN |
18019197 |
25/20 |
CERN |
18019198 |
25/28 |
SLAC |
18019199 |
25/25 |
SLAC |
Schematics of the MCC board: MCC_board_schematics.pdf and the Genova Pixel R&D page
As in the regular setup, the TPCC board has to be powered with +5V and -5V. The MCC board has to be powered with +3.3V. To power the Single Chip Board with Analog=1.6V and Digital=2.0V, there are two options:
The tests were carried out using TurboDaq 5.9 on the new EUDET DAQ PC in Lab 161 at CERN by P. Hansson, A. La Rosa and G. Troska.
Summary of the MCC tests with 3 single chips:
The number in parenthesis is the ("chip nr"/"Geographical address").
The tuned configurations including capacitance/vcal was loaded (some were old and may need to be redone) and a configuration file was saved in TEST2/.
In all cases only the first 3 channels were used and except for the single channel tests at SLAC before shipping the other have not yet been tested.
Test ID |
MCC Board ID/MCC CHIP |
Sensors |
DIGITAL SRAM |
THRESHOLD |
SOURCE |
---|---|---|---|---|---|
1 |
25/20 |
1,2,3 |
OK |
OK |
OK |
2 |
25/26 |
1, 3 |
OK |
OK |
OK |
3 |
25/27 |
1,3 |
OK |
OK |
OK |
Test ID 1
Digital test:
Threshold scan
HV was applied. Sensor 1=-15V, sensor 2,3=-15V
Test ID 2
Digital test:
Threshold scan:
Source test:
1000 triggers
Test ID 3
Digital test:
Threshold scan:
Source test: