Module:
Power Supply:
Cooling unit:
Monitoring unit
Database: link
The ITk pixel module cooling Twiki page is the main source for the common information. This page captures the local module cooling setup information at the SLAC Integration site. A talk by Magne Lauritzen (Jul/7/2020) has some updated status and additional pictures.
Equipment recommendation:
cooling:
PSU current / voltage requirement : 11 A / 8 V
chiller requirements: capacity > 385 W
System Test Description from Bologna : [can check this details: for Peltier and chiller need to check]
Similar settings are shown here presented by Argonne: link slide6 link2
Equipment setup:
power supply:
current / voltage: 0-10A / 0-32V
Wiener Mpod (2channel, HV/LV)
Rohde and Schwarz HMP4040
Monitoring:
Temperature: NTC
Humidity (inside cooling unit): SHT85, (+/- %RH and +/- 0.1 C)
Humidity (inside cold box): Thorlabs TSP01 (+/- accuracy)
Arduino Mega 2560
Cooling:
Cooling unit: qual cooling unit v5
Chiller: Julabo HL CF41
Coolant: 100% silicone oil
Dry, room temperature nitrogen
Room temperature vacuum
TIM sheet: Panasonic EYG-S0909LZX2
TEC combination:
TEC 1: Larid 1081611050003
TEC 2: Larid 387004685
version 1: List of components:
https://docs.google.com/spreadsheets/d/1dNT5ja_pFS2P6HJojZd5K-uXMyx7_lAjD4M-GH4URZ4/edit?usp=sharing
Apr 22 2021 List of component:
https://docs.google.com/spreadsheets/d/1BgjfFbXAt-ffoCWYGcLghxHP21pGV1TTFr1I7jS42yg/edit#gid=0
|
---|
The following items are listed by names and counts from each box of the entire package from CERN. For example, there are 6 POM base plates in total, but they came as sets of there in two separate boxes. Pictures will come soon.
They're being shipped from CERN 12/11 https://edh.cern.ch/Document/8559982 together with the Triplet Cooling unit.
Some notes from Saverio:
-- M6 bolt are 10/32 - we need to find more here.
-- The coolant tube is slightly shorter
-- There are spares for all the screw types and the vacuum chucks rubber pads have been already cut
Triplet cooling unit assembly procedure (CERN box)
Quad cooling unit assembly procedure (CERN box)
E-mail from Magne Lautitzen to atlas-itk-pixel-modules-TestSystem (Oct/26/2020):
To operate the cooling unit, you will need the following infrastructure:
The amount of dry air or nitrogen needed to maintain a dry atmosphere in the cooling unit will depend on the humidity in your lab and the lowest temperature you want to reach on the module. A ballpark figure is 1.5L/min at -25C.
The circulating chiller must have a cooling capacity that depends on how cold you need to take the modules. See page 13 on this presentation for recommendations for reaching -55C.
For stable temperature control of the modules, you will need a peltier controller. I have been successfully using the Meerstetter 1089.
To avoid condensation on the peltier devices, you must maintain a dry atmosphere in the cooling unit whenever there is coolant flowing through the coldplate. If condensation forms on the peltier devices, it will degrade the performance of the cooling unit because ice and water is an excellent conductor of heat. Getting rid of this condensation requires a long term “bakeout” of the coldstack and is best avoided.
Temperature sensor: pT100
Setting up SHT85
Connecting SHT85 to raspberry pi:
Setup:
PI to SHT85 (datasheet)
pin 1 3.3V. to 2 VDD
pin 3 SDA to 4 SDA Serial data
pin 5 SCL to 1 SCL Serial clock
pin 9: ground to 3 VSS Ground
Testing for sensor: Reading ( Temp(C), Humidity (%), Dew Point (C))
Readout: RTD Data Acquisition Stackable Card for Raspberry Pi with Raspberry Pi
Firmware to control: https://github.com/SequentMicrosystems/rtd-rpi
For SHT85: https://github.com/jothanna/sht85/tree/master/sht85
connecting to the raspberry pi:
Readout RTD database:http://atlascr.slac.stanford.edu:3000/d/AhqDEQ_Mk/dcs-cooling-tests?orgId=1&from=1619033502000&to=now&refresh=1m
(login atlas/atlas)
Action when fail is to turn off the power of Peltier and module
There are two ThermoCube units in B84/TID cabinet. Unit #1 is with full tubing setup and regularly used by Gabriel Blaj for LCLS so that we are trying to use unit #2 (no tubing) by assembling similar tubing arrangement as unit #1. Unit #2 has different coolant connectors compared to unit #1, but the rest of the tubing can work the same way still.
Unit #2 Model | 10-400-3G20-1-CP2-R2-LT-AR |
---|---|
-400 | ~400W @ 20C with ambient air cooling for the Cube |
3G20 | >3 lpm @30 pig magnetic drive gear pump. Adjustable flow setting for 2 lpm. |
CP2 | 3/8" CPC shut off valve (1-3 lpm) |
R2 | RS232 interface controller |
LT | Low temperature operation (<5C) |
AR | Auto reset - software |
Coolant connector (3/8" CPC) on unit #2 | Connection to the filter for unit #1 | Unit #1 with Swagelock QC4-316 joint for application insertion | Unit #1 view from above its filter |
---|---|---|---|
|
|
Thermo Cube: Chiller manual
Tables for chiller cycle tubing connection:
c) From process out (chiller) to filter | ||||
Coolant connector (3/8" CPC) on unit #2 (PROCESS OUT) | 3/8" Hose Barb HFC 12 Series Polypropylene Elbow Coupling Insert - Shutoff: link | 3/8" ID 1/2" OD tube (E-3603 Tygon PVC Tubing for Chemicals ) link45 cm (?) | 3/8" MNPT x 3/8" Hose Barb Polypropylene ElbowLink | 3/8 NPT female interface of filter housing link |
---|---|---|---|---|
|
From filter(out) to application (cold plate) | |||||||||
3/8 NPT female interface filter housing link | 3/8" NPT HFC 12 Series Polypropylene Coupling Body - Shutoff link | 3/8" Hose Barb HFC 12 Series Polypropylene Elbow Coupling Insert - Shutoff: link | 3/8" ID 1/2"OD tube(E-3603 Tygon PVC Tubing for Chemicals) link 15 cm | Brass Barbed Hose Fitting for Air and Water(Straight Reducer for 3/8" x 1/4" Hose ID ) link | 1/4" ID and 3/8" OD ( E-3603 Tygon PVC Tubing for Chemicals) 30 cm | Swagelok Instrumentation quick connect ( Stainless Steel Instrumentation Quick Connect Body ) SS-QC6-B-600 (3/8") | Swagelok Instrumentation quick connect ( Stainless Steel Instrumentation Quick Connect Stem with Valve ) SS-QC6-D-600 (3/8") | 1/4" ID and 3/8" OD ( E-3603 Tygon PVC Tubing for Chemicals) 140 cm | cold plate (can fit 1/4 " ID) |
---|---|---|---|---|---|---|---|---|---|
From application (cold plate) to chiller (process in) | |||||||||
cold plate (can fit 1/4 " ID) | 1/4" ID and 3/8" OD ( E-3603 Tygon PVC Tubing for Chemicals) 140 cm | Swagelok Instrumentation quick connect ( Stainless Steel Instrumentation Quick Connect Body ) SS-QC6-B-600 (3/8") | Swagelok Instrumentation quick connect ( Stainless Steel Instrumentation Quick Connect Stem with Valve ) SS-QC6-D-600 (3/8") | 1/4" ID and 3/8" OD ( E-3603 Tygon PVC Tubing for Chemicals) 30 cm | Brass Barbed Hose Fitting for Air and Water(Straight Reducer for 3/8" x 1/4" Hose ID ) link | 3/8" ID 1/2"OD tube(E-3603 Tygon PVC Tubing for Chemicals) link 15 cm | 3/8" Hose Barb HFC 12 Series Polypropylene Elbow Coupling Insert - Shutoff: link | 3/4" NPT HFC 12 Series Polypropylene Coupling Body - Shutoff link | Coolant connector (3/8" CPC) on unit #2 (PROCESS in) |
---|---|---|---|---|---|---|---|---|---|
|
We intend to use the ThermoCube recommended coolant Koolance 702 (27% propylene glyco + water mix): https://koolance.com/liq-702-liquid-coolant-bottle-high-performance-700ml-blue. Propylene glyco is a nicer substance (used as food additive in some cases) than the more commonly used ethylene glyco as an alternative antifreeze.
The ThermoCube tank is 300 ml but there may be some additional piping volume within chiller besides the 300ml. The tubing outside the chiller (not including filter) is <~200ml. So it may sufficiently safe if we get two 700ml bottles of the recommended Koolance 702. This unit description doesn’t say what type of cold plate it has. Stainless would have carried a tag ’S” in the model number somewhere so this may be old style anodized AL PCW plate ? Koolance claims to be friendly with both Al and SS.
The vacuum chuck has 3mm diameter hole for the vacuum line tube (OD/ID=3mm/1.8mm). The vacuum pump at B84 EPP lab is a GAST DOA-P704-AA with max pressure of 4 bar (60 psi). The left port (looking from front) has a 3/8" barb that we intend to connect a braided firm polyurethane rubber tube (McMaster-Carr #51165K12) with ID:OD=3/8":5/8" which runs ~1.5m from below the table to the top of table. This pump vacuum tube then transitions to the short (~30cm) 3mm OD vacuum chuck tube with a shut off valve and vacuum gauge in the transition region so that vacuum on the cooling unit can be held with monitoring after pumping. Since the vacuum gauge connection are mostly SS, we also opt for SS parts: Push on hose fitting (McMaster-Carr #53515K31) with 3/8" barb for pump tube transition to 1/4" NPT followed by On/off valve (McMaster-Carr #45395K216) and 1/4" Tee (McMaster-Carr #4452K432) for vacuum gauge mount. The Tee port is compatible with the Omega OEM pressure transmitter PX119-015AI, with SS 1/4" NPT mount and a 0-15psi absolute pressure measurement range. This device with miniDIN 43650C connection can be read out by the Sequent Industrial Automation Raspberry Pi interface card that can supply the 24V needed pay PX119. The final connection to the vacuum chuck tube could use a nylon part with 1/16" barb and 1/4" NPT (McMaster-Carr #5153K37). Unfortunately here is no SS bodied corresponding part. The 1/16" (1.59mm) barb is a approx match to the vacuum chuck tube with ~1.8mm ID (adequate tightness to be verified).
GAST DOS-P704-AA | Left pump port with 3/8" barb |
---|---|
Table for vacuum unit connections
Left pump port with 3/8" barb | High-Pressure Firm Polyurethane Rubber TubingID:OD=3/8":5/8" Link ~1.5 m | 316 Stainless Steel Push-on Hose Fitting for Air and Water3/8" Hose ID, 1/4 NPT Male End Link | On/off valve High-Pressure Compact 316 Stainless Steel On/Off Valvewith Lever Handle, 1/4 NPT Female x 1/4 NPT MaleLink | 1/4" Tee316 Stainless Steel Threaded Pipe FittingLow-Pressure, Tee Connector, 1/4 NPT Female | Plastic Barbed Tube Fitting for Air and WaterSwivel Adapter, for 1/16" Tube ID (1.6 mm)x 1/4 NPT Male | cern tube OD/ID=3mm/1.8mm (~30cm) |
---|---|---|---|---|---|---|
to be connect to Remote monitor vacuum pressure sensor (Omega PX119-015A): |
The dry air filters were saved by Matt from BaBar, residing inside the curtained area of B84 EPP lab. House compressed air are filtered to let out through the flow meter with a max flow of 20 ft3/min. A 80ft long hard polypropylene tubing with 1/4" OD (McMaster-Carr #9349T2) takes the drive air down to the ATLAS benches. The dry air supply tube terminates at a diverting valve (no shutoff) (McMaster #45165K42) on the bench to allow the switching of the dry air between a test port and the through path to module cooling unit. The through path continues with the same type of tube to transition to the 30cm long dry air tube into the module cooling unit which is an ID/OD=1.8mm/3.0mm blue tube from CERN shipment (same as the vacuum tube). This transition uses a similar strategy as the vacuum tubes, with a pair of Aluminum low-pressure 1/4 NPT adaptor to barbed tube fitting: 1/4" barb - male NPT (with O-ring) on supply side (McMaster-Carr #5058K441); 1/16" barb and female NPT on module side (McMaster-Carr #5058K641). The initial turn on of dry air should let run for a few hours with the outlet going to the test port using the diverting valve. Check flow and humidity at the test port before flowing into the module cooling unit. Once on for operation, the dry air flow should not be turned off. From an off state, the restart should always have the few hours of initial flush first. During operations, if the dry air needs to be off at the module cooling unit, use the diverting valve to temporarily directing the air to the test port. |
---|
long hard polypropylene tubing with 1/4" OD11/64" ID, 1/4" OD~ 80 ft | Diverting Valve with Yor-Lok Fittingsfor 1/4" Tube OD, 316 Stainless Steel BodyLink | Aluminum Low-Pressure Barbed Tube Fittingfor Air and Water, Adapter for 1/4" Tube IDx 1/4 NPT Male | Aluminum Low-Pressure Barbed Tube Fittingfor Air and Water, Adapter for 1/16"(1.6mm) ID Tube x 1/4 NPT Female | cern tube OD/ID=3mm/1.8mm (~30cm) |
---|---|---|---|---|
one to application/ one to testing area |
Peltier TE-127-1.0-2.5:
peltier | Laird 387004685 (125W) | HP-199-1.4-0.8 (120W) | HP-199-1.4-1.15 (175W) |
---|---|---|---|
figure | |||
properties | Qmax 125 W | Q max 120 W | Q max 175 W |
data sheet | Link | Link | Link |
measurements | P~ 10W delta T =11 C (without load) | P~9W delta T =12 C P~20W delta T =15 C | P ~ 6W delta T = 6 C P~ 17.5W delta T = 9 C |
Empty load step up | With Heater | with foam box |
---|---|---|