Number settable by rotating switches, add pic to show MSB, LSB.

Type is in the FPGA.

Type is also in database templates.

Types have #defines in mpsLinkNodeMacros.h which can be used for conditional behavior:

/* MPS Link Node Configuration Modes */
#define MPS_ANA_MODE                (0x05)
#define MPS_PIC_MODE                (0x04)
#define MPS_MPG_CONTROL_MODE        (0x03)
#define MPS_BYKIK_MODE              (0x02)
#define MPS_BLM_MODE                (0x01)
#define MPS_MITIGATION_CONTROL_MODE (0x00)

 

Booting sequence:

mpsInitialize reads rotary switches for link node #, identity/type from FPGA.

loading db files uses C functions to look up loca and unit, load db with that loca and unit in the file name

mpsGetLinkNodeLOCA() and mpsGetLinkNodeUNIT() functions use link node ID # to index arrays at the top of drvMpsLinkNode.c:

char *primaries[50]

char *LOCATIONS[50]

char *locations[50]

char *UNITS[50]

char *units[50]

Add the loca and unit to these arrays following existing pattern.

 

Databases