Usage is: cob_dump_bsi [OPTIONS] <rce_address> [<rce_address> ...]
Produces (sort-of-)human readable representations of the
RCE BootStrap Interface. Not all BSI areas are available
on DPMs, but requesting those produces no output.
Where the OPTIONS are:
--raw Dump of raw BSI contents
--rce Dump RCE information
--cluster Dump Cluster information
--switch Dump COB switch configuration information
--shelf Dump shelf IP information
--fabric Dump shelf fabric map
--all Dump all of the above information except raw
(can be issued with --raw to get raw and all)
Each <rce address> is of the form:
shelfmanager_ip[/slot[/bay[/rce]]]
Where:
shelfmanager_ip: the hostname of the shelf manager or its IP address
WARNING: THIS IS NOT THE SHELF NAME!
slot: the physical slot number (1-16)
or the case-insensitive keyword ALL
bay: the bay number (0-7)
or one of the case-insensitive keywords:
ALL, CMB, DTM, DPM, RTM, CEN
rce: the RCE number (0-3)
or the case-insensitive keyword ALL.
Leaving off the end of the address is the same
as using the keyword ALL for the omitted arguments.
Examples:
egbert-sm/4/3/2
egbert-sm/4/3
egbert-sm/4/
egbert-sm/
egbert-sm/4/ALL/2
egbert-sm/4/dpm
egbert-sm/4/DPM/0
172.21.6.112/4/3/2
Return Value:
0 if OK
1 Error