You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 16 Next »

Individual board testing

Resistance measurement with cable attached

  • Cable was produced in-house, see TIDIDECS-114 - Getting issue details... STATUS
  • There are no serial number on the cables, so for now only using one and assigning it "Cable 01"
  • Measuring between banana connector on the cable and test points on the board

PhotoSENSOR HVHV GNDAGNDP24V0ADGNDP24V0D
Cable 01 - Board 38-C00-02

0.6R0.7R0.4R0.4R0.3R0.3R