test:Excel spreadsheet for the FEL settings is here.

Is there an issue? Escalation Path

  • Issue concerns X-ray beam delivery: see here
  • Issue concerns ECS: see here
  • Spatial overlap of the optical lasers (drive and VISAR) with X-rays
    • Start by moving to the desired target (refer to the python manual here for details on the arguments)

      op.move_to_target(config="coliner", frame_cfg=[1, "F1", 1, "F2", 1, "F3"], frame=2, target="A2")
    • Continue by checking the alignment of the drive lasers

      • Decrease the energy of the laser to its minimum

        op.HWPon("all", set_T=0)
      • Confirm the filter of Questar 1 is in position 2 (no filter) to allow all wavelength to be seen
      • Adjust the signal on the camera my moving the slider 'max' to the maximum value and set the gain to 0
      • Set the NsSlicer to 10Hz and then click on the corresponding button which says 'ENB'
      • Confirm you see a scattering signal close to the X-ray cross (342, 561)
      • Move the hexapod X axis to center the beams on the cross and produce a round scattering signal

        x.tg_x.umvr(50e-6)
    • Continue by checking the alignment of the VISAR system
      • Adjust the VISAR Z axis to make sure the image is round and sharp (could be set to the value by using the right equation as well)

        x.visar_z.umvr(50e-6)
      • Alternatively, move the Z value by exactly the hitckness of the ablator + material of interest and add the change in position due to the visar window
        op.visar_z(material="LiF", thickness=400e-6)
  • Take a reference

    op.ref_only(
    	xray_trans=0.2,
    	xray_num=5,
    	shutters=False,
    	dark=0,
    	daq_end=True,
    	calibrant="",
    	rate=1,
    	visar=True,
    	save=True,
    	slow_cam=False
    )
  • Take a shot

    op.optical_shot(
    	shutter_close=[1, 2, 3, 4, 5, 6],
    	lpl_ener=0.3,
    	timing=5.0e-9
    	xray_trans=1,
    	xray_threshold=0.2,
    	save=True,
    	daq_end=True,
    	auto_trig=True,
    	auto_charge=True,
    	visar=True,
    	debug=False,
    	ps_opt=True
    )
  • Temporal overlap
    • go to Ti sample

      op.ti()