New Cameras
New cameras are in a plastic bin in the B244 back room.
Procedure
Example: Replacing IPOTR1, IPOTR2, and DSOTR
- Align HeNe to beam marks on FrontView, IPOTR1, IPOTR2, and DSOTR.
- This can be done with IP area vented or under vacuum. Note that you will have to realign HeNe going from vacuum to vented and vice-versa.
- Replace burned cameras with new cameras.
- IPOTR1/2 are Manta G-095B cameras. They can be replaced with Mako or Manta G-125B cameras. If Mako, you might need to adjust how the camera is mounted.
- Label cameras and note new serial numbers in the eLog.
- After replacing the camera, reboot to connect. If the camera does not connect, an IOC reboot might be necessary. Rebooting the IOC should connect the new camera.
- Verify alignment and focus.
- The HeNe should be in the center of the camera image.
- The “mark” position on the OTR foils should be clear and in focus. You may need to use a flashlight for illumination.
Reset Reboot Count
After the camera has been replaced, reset the reboot count to 0:
[fphysics@facet-srv01 ~/shperez ]$ caput CAMR:LI20:102:REBOOTCOUNT 0 |
Also double check that the serial number has updated:
[fphysics@facet-srv01 ~/shperez ]$ caget CAMR:LI20:102:SerialNumber_RBV |