You are viewing an old version of this page. View the current version.

Compare with Current View Page History

Version 1 Next »

Reason for change

Request to put AlarmsCfg-06-05-01 in production.

This new tag implements a change in the upper warning limit for the pedestal mean deviation of acd tile 44 ( PmtB)     

The detailed description of the changes is in the last section.

 

Test Procedure

Monitoring products from real on-orbit data (LPA) have been locally processed  with this version of AlarmsCfg.

Rollback procedure

The package can be rolled back to the previous version by flipping a soft link. Also note that the package is completely independent from any other package running in the pipeline and will not cause a version change of L1Proc.

CCB JIRA

 - Request to update alarm settings -

Details (release notes for AlarmsCfg-06-05-01)

Relaxing the upper  warning limit on AcdPedPedMeanDeviation_PMTB_TH1 for  acd tile 44.

 In  xml/acdpeds_eor_alarms.xml:  the upper warning limit on   AcdPedPedMeanDeviation_PMTB_TH1 for acd tile 44 has been  changed from 8  to 10

Relevant thread:

 https://www-glast.stanford.edu/protected/mail/datamon/14159.html

  • No labels