Search/Navigation:
Related:
SLAC/EPP
/HPS Public
Jefferson Lab/Hall B
/HPS Run Wiki
S30XL-LESA/LDMX
All operations are from hpstracker in group C.
Table as of 11/17/2014
GUI FEB ID | Physical FEB | Status | Comment |
---|---|---|---|
0 | L1t | OK | |
1 | L2-3t | OK | |
2 | L5t | OK | |
3 | L6t | OK | |
4 | L4t | OK | These should be checked! |
5 | L4b | OK | |
6 | L5b | OK | |
7 | L6b | DIG bad (Y-cable problem?) | |
8 | L2-3b | OK | |
9 | L1b | Short on AVDD? |
GUI Flange ID | Physical Flange Board | Status |
---|---|---|
0 | 1 (top) | OK |
1 | 2 | OK |
2 | 3 | OK |
3 | 4 (bottom) | OK |
!!! Remember to turn the fan on the FEB. !!!
Turn on the power to the FEB
Instructions on how to power the FEB using MPOD with EPICS
FEB Power using Keithley: AVDDP: 5.5V, AVDDN: 5.5V, DVDD: 5.5V and flange power 5.5V (parallel to DVDD).
The MPOD web GUI is at ppa-mpod1.slac.stanford.edu (visible on SLAC internal network only).
MPOD power settings (max current, trip current, trip behavior, sense behavior) are set by ./mpod/setDefaults.py. You should not need to run this unless you need to change the settings.
Example SNMP commands for switching on/off channels or the crate are in mpod/on.sh and mpod/off.sh.
MPOD will not turn on unless the interlock is plugged in (DB9 on MPOD controller at the left of the crate), turned on (24 V on BK power supply next to chiller), and not tripped (red LED on flow switch = switch is powered and flow is above trip point).
Start the DAQ:
$ cd /u1/software/software_new
$ source setup_env.csh
$ ./bin/frontEndTestGui
Click <read status> and make sure no error is seen. If so, check that the FEB is powered correctly.
Make sure the AxiXadc temperature is ok (50-60C).
Configure with config/FrontEndBoardConfigC01.xml
Click <read status> and check that more registers are found.
Turn on power to hybrids (see below)
Do a hard reset under commands/FebCore/HybridHardReset (current on AVDDP should drop ~100mA).
Click <Write config>.
Do a soft reset under commands/FebCore/HybridSoftReset.
Check that the hybrid currents measured are ok. Sync status for each channel can be seen in register RceCore/DataPath[x]/Synced, 1xf for powered channels.
Instructions for powering hybrids with EPICS.
In the DAQ GUI: go to config and turn on power to hybrids using Register: HybridXPwrEn (X=0,1,2,3).
Click <Write config>. Check that it worked by reading status and voltages/currents.
Typically after a reboot we need to reload the pgp card driver.
$ cd /u1/pgpcard/software/driver_old/
$ ./pgpcard_load