The mcdrcal00 detector model:

Properties of the calorimeter which is realized as a dual readout optical calorimeter and muon system:

 

electromagnetic section

hadronic section

muon system

material

BGO (PbF2)

BGO (PbF2)

Iron

<ac:structured-macro ac:name="unmigrated-wiki-markup" ac:schema-version="1" ac:macro-id="d8b30128-e461-489c-b8ed-7928a822a6fe"><ac:plain-text-body><![CDATA[

density [ g/cm3 ]

7.13 (7.77)

7.13 (7.77)

7.85

]]></ac:plain-text-body></ac:structured-macro>

<ac:structured-macro ac:name="unmigrated-wiki-markup" ac:schema-version="1" ac:macro-id="935683c3-a6d8-4b52-92a4-d0964f60b1f0"><ac:plain-text-body><![CDATA[

Cell size [ cm ]

1x1x2

2x2x5

10x10x10

]]></ac:plain-text-body></ac:structured-macro>

Layers

10

30

22

<ac:structured-macro ac:name="unmigrated-wiki-markup" ac:schema-version="1" ac:macro-id="2ed6ccf5-91a1-4b70-b365-dda2a3232e60"><ac:plain-text-body><![CDATA[

Detector Depth [cm]

20

150

220

]]></ac:plain-text-body></ac:structured-macro>

<ac:structured-macro ac:name="unmigrated-wiki-markup" ac:schema-version="1" ac:macro-id="6f308123-4a52-4900-ac9c-88f38a2633d2"><ac:plain-text-body><![CDATA[

Radiation Length [cm]

1.1 (0.93)

1.1 (0.93)

1.76

]]></ac:plain-text-body></ac:structured-macro>

<ac:structured-macro ac:name="unmigrated-wiki-markup" ac:schema-version="1" ac:macro-id="84dba57a-4414-46f6-a229-6edf104bc17d"><ac:plain-text-body><![CDATA[

IA length [cm]

22.7 (22.4)

22.7 (22.4)

16.8

]]></ac:plain-text-body></ac:structured-macro>

Total Nr of IA length (em+had)

7.5 (7.6)